TFOS Lifestyle: Impact of the digital environment on the ocular surface
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Eye strain when performing tasks reliant on a digital environment can cause discomfort, affecting productivity and quality of life. Digital eye strain (the preferred terminology) was defined as "the development or exacerbation of recurrent ocular symptoms and/or signs related specifically to digital device screen viewing". Digital eye strain prevalence of up to 97% has been reported, due to no previously agreed definition/diagnostic criteria and limitations of current questionnaires which fail to differentiate such symptoms from those arising from non-digital tasks. Objective signs such as blink rate or critical flicker frequency changes are not 'diagnostic' of digital eye strain nor validated as sensitive. The mechanisms attributed to ocular surface disease exacerbation are mainly reduced blink rate and completeness, partial/uncorrected refractive error and/or underlying binocular vision anomalies, together with the cognitive demand of the task and differences in position, size, brightness and glare compared to an equivalent non-digital task. In general, interventions are not well established; patients experiencing digital eye strain should be provided with a full refractive correction for the appropriate working distances. Improving blinking, optimizing the work environment and encouraging regular breaks may help. Based on current, best evidence, blue-light blocking interventions do not appear to be an effective management strategy. More and larger clinical trials are needed to assess artificial tear effectiveness for relieving digital eye strain, particularly comparing different constituents; a systematic review within the report identified use of secretagogues and warm compress/humidity goggles/ambient humidifiers as promising strategies, along with nutritional supplementation (such as omega-3 fatty acid supplementation and berry extracts).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RoB 2: a revised tool for assessing risk of bias in randomised trials
Sterne, J. A. C., Savović, J., Page, M. J., Elbers, R. G., Blencowe, N. S., Boutron, I., Cates, C. J., Cheng, H.-Y., Corbett, M. S., Eldridge, S. M., et al. (2019) · BMJ · doi:10.1136/bmj.l4898 · Cited by 34,787
GRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305 · cited 7×
“opment and Evaluations (GRADE) method [598].”
BackgroundInfluentialWan, X., Wang, W., Liu, J., & Tong, T. (2014) · BMC Medical Research Methodology · doi:10.1186/1471-2288-14-135 · Cited by 11,735
Schulz (1995) · doi:10.1001/jama.1995.03520290060030 · Cited by 5,634 · cited 1×
“Studies in which participants are not adequately masked to intervention assignment risk bias toward results favoring the intervention [500]; it is therefore difficult to make an accurate assessment of treatment efficacy when there is potential for ascertainment bias.”
BackgroundProceedings of the 2020 CHI Conference on Human Factors in Computing Systems
(2020) · doi:10.1145/3313831 · Cited by 1,951
Action Spectrum for Melatonin Regulation in Humans: Evidence for a Novel Circadian Photoreceptor
Brainard, G. C., Hanifin, J. P., Greeson, J. M., Byrne, B., Glickman, G., Gerner, E., & Rollag, M. D. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-16-06405.2001 · Cited by 1,930
Thapan, K., Arendt, J., & Skene, D. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.t01-1-00261.x · Cited by 1,320
Presence and Cybersickness in Virtual Reality Are Negatively Related: A Review
Weech, S., Kenny, S., & Barnett-Cowan, M. (2019) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.00158 · Cited by 913
High Sensitivity of the Human Circadian Melatonin Rhythm to Resetting by Short Wavelength Light
Lockley, S. W., Brainard, G. C., & Czeisler, C. A. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030570 · Cited by 782
Cajochen, C., Frey, S., Anders, D., Späti, J., Bues, M., Pross, A., Mager, R., Wirz-Justice, A., & Stefani, O. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00165.2011 · Cited by 730
Sleep and use of electronic devices in adolescence: results from a large population-based study
Hysing, M., Pallesen, S., Stormark, K. M., Jakobsen, R., Lundervold, A. J., & Sivertsen, B. (2015) · BMJ Open · doi:10.1136/bmjopen-2014-006748 · Cited by 678
The burden of musculoskeletal diseases in the United States
Yelin, E., Weinstein, S., & King, T. (2016) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2016.07.013 · Cited by 537
Effects of blue light on the circadian system and eye physiology
Tosini, G., Ferguson, I., & Tsubota, K. (2016) · Molecular Vision · doi:10.63500/mv_v22_61 · Cited by 517
Digital Wellbeing as a Dynamic Construct
Vanden Abeele, M. M. P. (2021) · Communication Theory · doi:10.1093/ct/qtaa024 · Cited by 516
The inner clock-Blue light sets the human rhythm
Wahl, S., Engelhardt, M., Schaupp, P., Lappe, C., & Ivanov, I. V. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201900102 · Cited by 293
Bernard, M. L., Chaparro, B. S., Mills, M. M., & Halcomb, C. G. (2003) · International Journal of Human-Computer Studies · doi:10.1016/s1071-5819(03)00121-6 · Cited by 244 · cited 2×
“Reading smaller text also increases visual fatigue [159,160,273].”
BackgroundINTERMITTENT STIMULATION BY LIGHT
Hecht, S., & Shlaer, S. (1936) · Journal of General Physiology · doi:10.1085/jgp.19.6.965 · Cited by 209
Head-mounted virtual reality and mental health: critical review of current research
Jerdan, S. W., Grindle, M., van Woerden, H. C., & Kamel Boulos, M. N. (2018) · JMIR Serious Games · doi:10.2196/games.9226 · Cited by 187 · cited 1×
“field-of-view approaching that of the human eye [241].”
BackgroundViewing distance and eyestrain symptoms with prolonged viewing of smartphones
Long, J., Cheung, R., Duong, S., Paynter, R., & Asper, L. (2017) · Clinical and Experimental Optometry · doi:10.1111/cxo.12453 · Cited by 185 · cited 3×
“In addition, closer working distances are usually adopted while viewing material on smartphones [204,210], which may pose a need for a different refractive correction, especially in presbyopic populations [390].”
BackgroundDeinema, L. A., Vingrys, A. J., Wong, C. Y., Jackson, D. C., Chinnery, H. R., & Downie, L. E. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.09.023 · Cited by 160 · cited 1×
“These agents are generally considered to modulate systemic inflammatory pathways, and have been shown to reduce tear pro-inflammatory cytokine levels in patients with dry eye disease [568] and promote corneal nerve regeneration in individuals with diabetes [569].”
BackgroundSelf-citationda Costa, B. R., Nüesch, E., Rutjes, A. W., Johnston, B. C., Reichenbach, S., Trelle, S., Guyatt, G. H., & Jüni, P. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.03.009 · Cited by 148 · cited 1×
“sults of such combinations have been empirically shown to produce valid pooled estimates [600].”
BackgroundSmartphone use as a possible risk factor for myopia
Mccrann, S., Loughman, J., Butler, J. S., Paudel, N., & Flitcroft, D. I. (2021) · Clinical and Experimental Optometry · doi:10.1111/cxo.13092 · Cited by 123
Oral omega-3 fatty acids treatment in computer vision syndrome related dry eye
Bhargava, R., Kumar, P., Phogat, H., Kaur, A., & Kumar, M. (2015) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2015.01.007 · Cited by 103 · cited 6×
“Two studies using an omega-3 fatty acid supplement conducted by the same research group reported improvement in digital eye strain symptoms, relative to the control group [572,573].”
BackgroundMethodResultInfluentialGringras, P., Middleton, B., Skene, D. J., & Revell, V. L. (2015) · Frontiers in Public Health · doi:10.3389/fpubh.2015.00233 · Cited by 100
Souman, J. L., Borra, T., de Goijer, I., Schlangen, L. J. M., Vlaskamp, B. N. S., & Lucassen, M. P. (2018) · Journal of Biological Rhythms · doi:10.1177/0748730418784041 · Cited by 96 · cited 1×
“Some clinical studies have indicated benefits of low blue light output displays on melatonin levels/sleep suppression [125,126] and tear film stability [127], while others have shown no beneficial effect on melatonin levels [124] or sleep outcomes [128] when using ‘night shift’ mode technology.”
BackgroundZheng, Y., Wang, W., Zhong, Y., Wu, F., Zhu, Z., Tham, Y.-C., Lamoureux, E., Xiao, L., Zhu, E., Liu, H., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/24316 · Cited by 73
Smartphone viewing distance and sleep: an experimental study utilizing motion capture technology
Yoshimura, M., Kitazawa, M., Maeda, Y., Mimura, M., Tsubota, K., & Kishimoto, T. (2017) · Nature and Science of Sleep · doi:10.2147/nss.s123319 · Cited by 67 · cited 2×
“screen size [105,157,158], task type [104], display type [96], character size [96,193], screen luminance [158,194], screen”
BackgroundDoes the iPad night shift mode reduce melatonin suppression?
Nagare, R., Plitnick, B., & Figueiro, M. (2019) · Lighting Research & Technology · doi:10.1177/1477153517748189 · Cited by 66 · cited 2×
“It has been suggested that brightness may be more important to melatonin suppression than spectral composition of the display [124] and that cognitive and psychological stimulation relating to screen use may play a role in sleep quality [128].”
Background
Cited by
TFOS DEWS III: Diagnostic Methodology
Wolffsohn, J. S., Benítez-Del-Castillo, J. M., Loya-Garcia, D., Inomata, T., Iyer, G., Liang, L., Pult, H., Sabater, A. L., Starr, C. E., Vehof, J., et al. (2025) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2025.05.033 · Cited by 221
Self-citation
Metadata
- Authors
- Wolffsohn, J. S., Lingham, G., Downie, L. E., Huntjens, B., Inomata, T., Jivraj, S., Kobia-Acquah, E., Muntz, A., Mohamed-Noriega, K., Plainis, S., Read, M., Sayegh, R. R., Singh, S., Utheim, T. P., & Craig, J. P.
- Venue
- The Ocular Surface
- Publisher
- Elsevier BV
- Published
- 2023-04
- Volume
- 28
- Pages
- 213-252
- ISSN
- 1542-0124 (ISSN-L)
- OpenAlex
- W4365512412
- Cited by
- 166
- References
- 28
- FWCI
- 47.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.