Beyond the lateral flow assay: A review of paper-based microfluidics
Open accessAbstract
The interest in and use of microfluidic paper-based analytical devices (μPADs) has grown exponentially over the last decade. Cellulose, and modified cellulose, has been used for centuries for making chemical measurements but devices made with this material traditionally suffered from either poor detection limits and/or limited ability to provide quantitative measurements. μPADs address these problems by patterning paper to create microfluidic channel networks that can direct flow to different regions of the device without the need for external pumps used in most traditional microfluidic devices. Furthermore, because the devices are made from cellulose or modified cellulose using inexpensive manufacturing methods, the devices can be inexpensive and disposable. The ability to carry out multiplexed analysis without external pumps using inexpensive, disposable devices makes μPADs ideal for point-of-care (POC) analysis. The interest in μPADs has led to a number of excellent comprehensive reviews in the field; in this review, we do not attempt to reference the entire field but instead seek to highlight major developments as well as areas that will be important for future development of this field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Self-citationElectrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Self-citationPoint-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
The use of electrochemical impedance spectroscopy for biosensing
Lisdat, F., & Schäfer, D. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1970-7 · Cited by 858
Diagnostic point-of-care tests in resource-limited settings
Drain, P. K., Hyle, E. P., Noubary, F., Freedberg, K. A., Wilson, D., Bishai, W. R., Rodriguez, W., & Bassett, I. V. (2014) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70250-0 · Cited by 744
Electrochemical impedance spectroscopy: an overview of bioanalytical applications
Randviir, E. P., & Banks, C. E. (2013) · Analytical Methods · doi:10.1039/c3ay26476a · Cited by 736
Electrogenerated Chemiluminescence Detection in Paper-Based Microfluidic Sensors
Delaney, J. L., Hogan, C. F., Tian, J., & Shen, W. (2011) · Analytical Chemistry · doi:10.1021/ac102392t · Cited by 592
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Paper-Based Microfluidic Devices: Emerging Themes and Applications
Yang, Y., Noviana, E., Nguyen, M. P., Geiss, B. J., Dandy, D. S., & Henry, C. S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04581 · Cited by 501
Self-citationPoint-of-care tests for diagnosing infections in the developing world
Peeling, R. W., & Mabey, D. (2010) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2010.03279.x · Cited by 500
Morbioli, G. G., Mazzu-Nascimento, T., Stockton, A. M., & Carrilho, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.037 · Cited by 434
Lopez-Ruiz, N., Curto, V. F., Erenas, M. M., Benito-Lopez, F., Diamond, D., Palma, A. J., & Capitan-Vallvey, L. F. (2014) · Analytical Chemistry · doi:10.1021/ac5019205 · Cited by 423
Swan, M. (2012) · Journal of Personalized Medicine · doi:10.3390/jpm2030093 · Cited by 397
Multilayer Paper-Based Device for Colorimetric and Electrochemical Quantification of Metals
Rattanarat, P., Dungchai, W., Cate, D., Volckens, J., Chailapakul, O., & Henry, C. S. (2014) · Analytical Chemistry · doi:10.1021/ac5000224 · Cited by 350
Self-citationMicrofluidics without pumps: reinventing the T-sensor and H-filter in paper networks
Osborn, J. L., Lutz, B., Fu, E., Kauffman, P., Stevens, D. Y., & Yager, P. (2010) · Lab on a Chip · doi:10.1039/c004821f · Cited by 338
Yu, J., Ge, L., Huang, J., Wang, S., & Ge, S. (2011) · Lab on a Chip · doi:10.1039/c0lc00524j · Cited by 327
Electrochemical Glucose Sensing: Is There Still Room for Improvement?
Witkowska Nery, E., Kundys, M., Jeleń, P. S., & Jönsson-Niedziółka, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03151 · Cited by 292
Paper-based chemical and biological sensors: Engineering aspects
Ahmed, S., Bui, M.-P. N., & Abbas, A. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.038 · Cited by 249
Developments of microfluidic paper-based analytical devices (μPADs) for water analysis: A review
Almeida, M. I. G. S., Jayawardane, B. M., Kolev, S. D., & McKelvie, I. D. (2017) · Talanta · doi:10.1016/j.talanta.2017.08.072 · Cited by 238
Development of a low-cost paper-based ELISA method for rapid Escherichia coli O157:H7 detection
Pang, B., Zhao, C., Li, L., Song, X., Xu, K., Wang, J., Liu, Y., Fu, K., Bao, H., Song, D., et al. (2018) · Analytical Biochemistry · doi:10.1016/j.ab.2017.11.010 · Cited by 223
Practical challenges related to point of care testing
Shaw, J. L. V. (2016) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2015.12.002 · Cited by 220
Srisa-Art, M., Boehle, K. E., Geiss, B. J., & Henry, C. S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04628 · Cited by 216
Self-citationAdkins, J. A., Boehle, K., Friend, C., Chamberlain, B., Bisha, B., & Henry, C. S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b05009 · Cited by 211
Self-citationPaper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
Sriram, G., Bhat, M. P., Patil, P., Uthappa, U. T., Jung, H.-Y., Altalhi, T., Kumeria, T., Aminabhavi, T. M., Pai, R. K., Madhuprasad, et al. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.06.005 · Cited by 204
Low-cost tools for diagnosing and monitoring HIV infection in low-resource settings
Wu, G., & Zaman, M. H. (2012) · Bulletin of the World Health Organization · doi:10.2471/blt.12.102780 · Cited by 190
Morales-Narváez, E., Naghdi, T., Zor, E., & Merkoçi, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02383 · Cited by 186
Microfluidic devices for sample preparation and rapid detection of foodborne pathogens
Kant, K., Shahbazi, M.-A., Dave, V. P., Ngo, T. A., Chidambara, V. A., Than, L. Q., Bang, D. D., & Wolff, A. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.03.002 · Cited by 179
Hollow-Channel Paper Analytical Devices
Renault, C., Li, X., Fosdick, S. E., & Crooks, R. M. (2013) · Analytical Chemistry · doi:10.1021/ac401786h · Cited by 177
Detection of Hepatitis B Virus DNA with a Paper Electrochemical Sensor
Li, X., Scida, K., & Crooks, R. M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02210 · Cited by 174
Determination of nitrite in saliva using microfluidic paper-based analytical devices
Bhakta, S. A., Borba, R., Taba, M., Garcia, C. D., & Carrilho, E. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.11.044 · Cited by 173
Fabrication of Low-Cost Paper-Based Microfluidic Devices by Embossing or Cut-and-Stack Methods
Thuo, M. M., Martinez, R. V., Lan, W.-J., Liu, X., Barber, J., Atkinson, M. B. J., Bandarage, D., Bloch, J.-F., & Whitesides, G. M. (2014) · Chemistry of Materials · doi:10.1021/cm501596s · Cited by 165
Uniform mixing in paper-based microfluidic systems using surface acoustic waves
Rezk, A. R., Qi, A., Friend, J. R., Li, W. H., & Yeo, L. Y. (2012) · Lab Chip · doi:10.1039/c2lc21065g · Cited by 164
Liang, L., Su, M., Li, L., Lan, F., Yang, G., Ge, S., Yu, J., & Song, X. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.01.137 · Cited by 164
What Are Clinically Relevant Levels of Cellular and Biomolecular Analytes?
Kelley, S. O. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00691 · Cited by 163
Paper-Based Colorimetric Biosensor for Tear Glucose Measurements
Gabriel, E. F. M., Garcia, P. D. T., Lopes, F. M., & Coltro, W. K. T. (2017) · Micromachines · doi:10.3390/mi8040104 · Cited by 132
Paper-based RNA detection and multiplexed analysis for Ebola virus diagnostics
Magro, L., Jacquelin, B., Escadafal, C., Garneret, P., Kwasiborski, A., Manuguerra, J., Monti, F., Sakuntabhai, A., Vanhomwegen, J., Lafaye, P. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00758-9 · Cited by 131
Wang, H., Li, Y., Wei, J., Ji-run, X., Wang, Y., & Zheng, G. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7715-x · Cited by 125
Jayawardane, B. M., McKelvie, I. D., & Kolev, S. D. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00125 · Cited by 110
Simple, Sensitive, and Quantitative Electrochemical Detection Method for Paper Analytical Devices
Scida, K., Cunningham, J. C., Renault, C., Richards, I., & Crooks, R. M. (2014) · Analytical Chemistry · doi:10.1021/ac501004a · Cited by 93
Lim, W. Y., Goh, B. T., & Khor, S. M. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.06.040 · Cited by 83
Progress in The Development of Paper-Based Diagnostics for Low-Resource Point-Of-Care Settings
Byrnes, S. A., Thiessen, G., & Fu, E. S. (2013) · Bioanalysis · doi:10.4155/bio.13.243 · Cited by 81
Eco-friendly electrochemical lab-on-paper for heavy metal detection
Medina‐Sánchez, M., Cadevall, M., Ros, J. O., et al. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9022-6 · Cited by 80
Biosensors for Blood Glucose and Diabetes Diagnosis: Evolution, Construction, and Current Status
Martinková, P., & Pohanka, M. (2015) · Analytical Letters · doi:10.1080/00032719.2015.1043661 · Cited by 62
Critical Care Glucose Point-of-Care Testing
Narla, S. N., Jones, M., Hermayer, K. L., & Zhu, Y. (2016) · Advances in clinical chemistry · doi:10.1016/bs.acc.2016.05.002 · Cited by 16
Cited by
Fabrication and Applications of Microfluidic Devices: A Review
Niculescu, A.-G., Chircov, C., Bîrcă, A. C., & Grumezescu, A. M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22042011 · Cited by 678
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Recent advances in high-sensitivity detection methods for paper-based lateral-flow assay
Nguyen, V.-T., Song, S., Park, S., & Joo, C. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112015 · Cited by 373
Droplet digital PCR of viral DNA/RNA, current progress, challenges, and future perspectives
Kojabad, A. A., Farzanehpour, M., Galeh, H. E. G., Dorostkar, R., Jafarpour, A., Bolandian, M., & Nodooshan, M. M. (2021) · Journal of Medical Virology · doi:10.1002/jmv.26846 · Cited by 297
Biosensors for rapid detection of bacterial pathogens in water, food and environment
Nnachi, R. C., Sui, N., Ke, B., Luo, Z., Bhalla, N., He, D., & Yang, Z. (2022) · Environment International · doi:10.1016/j.envint.2022.107357 · Cited by 297
Metadata
- Authors
- Carrell, C., Kava, A., Nguyen, M., Menger, R., Munshi, Z., Call, Z., Nussbaum, M., & Henry, C.
- Venue
- Microelectronic Engineering
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 206
- Pages
- 45-54
- ISSN
- 0167-9317 (ISSN-L)
- OpenAlex
- W2909969744
- Cited by
- 336
- References
- 51
- FWCI
- 16.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.