The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Biodegradable magnesium alloys for orthopaedic applications: A review on corrosion, biocompatibility and surface modifications
Open accessAbstract
Magnesium (Mg) and its alloys have been extensively explored as potential biodegradable implant materials for orthopaedic applications (e.g. Fracture fixation). However, the rapid corrosion of Mg based alloys in physiological conditions has delayed their introduction for therapeutic applications to date. The present review focuses on corrosion, biocompatibility and surface modifications of biodegradable Mg alloys for orthopaedic applications. Initially, the corrosion behaviour of Mg alloys and the effect of alloying elements on corrosion and biocompatibility is discussed. Furthermore, the influence of polymeric deposit coatings, namely sol-gel, synthetic aliphatic polyesters and natural polymers on corrosion and biological performance of Mg and its alloy for orthopaedic applications are presented. It was found that inclusion of alloying elements such as Al, Mn, Ca, Zn and rare earth elements provides improved corrosion resistance to Mg alloys. It has been also observed that sol-gel and synthetic aliphatic polyesters based coatings exhibit improved corrosion resistance as compared to natural polymers, which has higher biocompatibility due to their biomimetic nature. It is concluded that, surface modification is a promising approach to improve the performance of Mg-based biomaterials for orthopaedic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Cited by 9,358
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Biodegradable polymers as biomaterials
Nair, L. S., & Laurencin, C. T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.017 · Cited by 4,416
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
Corrosion Mechanisms of Magnesium Alloys
Song, G. L., & Atrens, A. (1999) · Advanced Engineering Materials · doi:10.1002/(sici)1527-2648(199909)1:1<11::aid-adem11>3.0.co;2-n · Cited by 2,365
Cited by
Fundamentals and advances in magnesium alloy corrosion
Esmaily, M., Svensson, J. E., Fajardo, S., Birbilis, N., Frankel, G. S., Virtanen, S., Arrabal, R., Thomas, S., & Johansson, L. G. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.04.011 · Cited by 2,073
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Chowdhury, S., Yadaiah, N., Prakash, C., Ramakrishna, S., Dixit, S., Gupta, L. R., & Buddhi, D. (2022) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2022.07.121 · Cited by 784
Bone biomaterials and interactions with stem cells
Gao, C., Peng, S., Feng, P., & Shuai, C. (2017) · Bone Research · doi:10.1038/boneres.2017.59 · Cited by 720
Biodegradable Mg alloys for orthopedic implants – A review
Tsakiris, V., Tardei, C., & Clicinschi, F. M. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.06.024 · Cited by 612
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Biodegradable Materials and Metallic Implants—A Review
Prakasam, M., Locs, J., Salma-Ancane, K., Loca, D., Largeteau, A., & Berzina-Cimdina, L. (2017) · Journal of Functional Biomaterials · doi:10.3390/jfb8040044 · Cited by 493
Advances in functionalized polymer coatings on biodegradable magnesium alloys–A review
Li, L.-Y., Cui, L.-Y., Zeng, R.-C., Li, S.-Q., Chen, X.-B., Zheng, Y., & Kannan, M. B. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.030 · Cited by 466
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Applications of Magnesium and Its Alloys: A Review
Tan, J., & Ramakrishna, S. (2021) · Applied Sciences · doi:10.3390/app11156861 · Cited by 350
Pharmaceutical electrospinning and 3D printing scaffold design for bone regeneration
Wang, Z., Wang, Y., Yan, J., Zhang, K., Lin, F., Xiang, L., Deng, L., Guan, Z., Cui, W., & Zhang, H. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.007 · Cited by 344
Biodegradable metallic bone implants
Shuai, C., Li, S., Peng, S., Feng, P., Lai, Y., & Gao, C. (2019) · Materials Chemistry Frontiers · doi:10.1039/c8qm00507a · Cited by 275
Bairagi, D., & Mandal, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.09.005 · Cited by 272
Updates on the research and development of absorbable metals for biomedical applications
Hermawan, H. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0091-4 · Cited by 260
A review on magnesium alloys for biomedical applications
Zhang, T., Wang, W., Liu, J., Wang, L., Tang, Y., & Wang, K. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.953344 · Cited by 208
Lin, Z., Sun, X., & Yang, H. (2021) · Materials & Design · doi:10.1016/j.matdes.2020.109350 · Cited by 156
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Chen, L., Zhu, J., Ge, N., Liu, Y., Yan, Z., Liu, G., Li, Y., Wang, Y., Wu, G., Qiu, T., et al. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2024.122992 · Cited by 53
Polymer bilayer-Micro arc oxidation surface coating on pure magnesium for bone implantation
Dong, J., Zhong, J., Hou, R., Hu, X., Chen, Y., Weng, H., Zhang, Z., Liu, B., Yang, S., & Peng, Z. (2023) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2023.05.003 · Cited by 33
Wang, Z., Liu, B., Yin, B., Zheng, Y., Tian, Y., & Wen, P. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.1066103 · Cited by 30
“Alloying elements, such as Al, Mn, Ca, Zn, and rare earth (RE) elements, improve the corrosion potential of the Mg matrix from a thermodynamic perspective, thereby improving the corrosion resistance of Mg-based biomaterials for bone implants (Agarwal et al., 2016).”
BackgroundMartinez, D. C., Borkam-Schuster, A., Helmholz, H., Dobkowska, A., Luthringer-Feyerabend, B., Płociński, T., Willumeit-Römer, R., & Święszkowski, W. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.08.015 · Cited by 21
Metadata
- Authors
- Agarwal, S., Curtin, J., Duffy, B., & Jaiswal, S.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 68
- Pages
- 948-963
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2418599019
- Cited by
- 955
- References
- 94
- FWCI
- 25.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.