CoChat

Myelin volume fraction imaging with MRI

Open access
West, Kathryn L., Kelm, Nathaniel D., Carson, Robert P., Gochberg, Daniel F., Ess, Kevin C., Does, Mark D. · 2018 · NeuroImage
Cited by 79

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Abstract MRI is a valuable tool to assess myelin during development and demyelinating disease processes. While multiexponential T2 and quantitative magnetization transfer measures correlate with myelin content, neither provides the total myelin volume fraction. In many cases correlative measures are adequate; but to assess microstructure of myelin, (e.g. calculate the g‐ratio using MRI), an accurate measure of myelin volume fraction is imperative. Using a volumetric model of white matter, we relate MRI measures of myelin to absolute measures of myelin volume fraction and compare them to quantitative histology. We assess our approach in control mice along with two models of hypomyelination and one model of hypermyelination and find strong agreement between MRI and histology amongst models. This work investigates the sensitivities of MRI myelin measures to changes in axon geometry and displays promise for estimating g‐ratio from MRI. Graphical abstract Figure. No caption available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2016.12.067

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Research works printed but not linked: 46

  1. Alonso-Ortiz, 2016, Field inhomogeneity correction for gradient echo myelin water fraction imaging, Magn. Reson. Med.
  2. Carson, 2015, Hypomyelination following deletion of Tsc2 in oligodendrocyte precursors, Ann. Clin. Transl. Neurol., 2, 1041, 10.1002/acn3.254 · DOI · Paper page
  3. Carson, 2013, Deletion of Rictor in neural progenitor cells reveals contributions of mTORC2 signaling to tuberous sclerosis complex, Human. Mol. Genet., 22, 140, 10.1093/hmg/dds414 · DOI · Paper page
  4. Denef, 1979, The influence of fixation procedure, embedding medium and section thickness on morphometric data in thyroid gland, Histochemistry, 63, 163, 10.1007/BF00644538 · DOI
  5. Does, 2002, Compartmental study of T1 and T2 in rat brain and trigeminal nerve in vivo, Magn. Reson. Med., 47, 274, 10.1002/mrm.10060 · DOI · Paper page
  6. Dortch, 2013, Characterizing inter compartmental water exchange in myelinated tissue using relaxation exchange spectroscopy, Magn. Reson. Med., 70, 1450, 10.1002/mrm.24571 · DOI · Paper page
  7. Dula, 2010, Multiexponential T2, magnetization transfer, and quantitative histology in white matter tracts of rat spinal cord, Magn. Reson. Med., 63, 902, 10.1002/mrm.22267 · DOI · Paper page
  8. Gochberg, 2007, Quantitative magnetization transfer imaging via selective inversion recovery with short repetition times, Magn. Reson. Med., 57, 437, 10.1002/mrm.21143 · DOI · Paper page
  9. Harkins, 2012, Effect of intercompartmental water exchange on the apparent myelin water fraction in multiexponential T2 measurements of rat spinal cord, Magn. Reson. Med., 67, 793, 10.1002/mrm.23053 · DOI · Paper page
  10. Harkins, 2013, In-vivo multi-exponential T2, magnetization transfer and quantitative histology in a rat model of intramyelinic edema, NeuroImage: Clin., 810, 10.1016/j.nicl.2013.06.007 · DOI · Paper page
  11. Harrington, 2010, Oligodendrocyte PTEN is required for myelin and axonal integrity, not remyelination, Ann. Neurol., 68, 703, 10.1002/ana.22090 · DOI · Paper page
  12. Henkelman, 1993, Quantitative interpretation of magnetization transfer, Magn. Reson. Med., 29, 759, 10.1002/mrm.1910290607 · DOI · Paper page
  13. Hennig, 1991, Echoes—how to generate, recognize, use or avoid them in MR-imaging sequences. Part II: echoes in imaging sequences, Concept. Magn. Reson., 3, 179, 10.1002/cmr.1820030402 · doi:10.1002/cmr.1820030402
  14. Horch, 2011, Origins of the ultrashort T21H NMR signals in myelinated nerve: a direct measure of myelin content?, Magn. Reson. Med., 66, 24, 10.1002/mrm.22980 · DOI · Paper page
  15. Hwang, 2010, In vivo multi-slice mapping of myelin water content using T 2* decay, NeuroImage, 52, 198, 10.1016/j.neuroimage.2010.04.023 · DOI · Paper page
  16. Johnson, 2002, Morphologic Phenotyping with MR Microscopy: the Visible Mouse, Radiology, 222, 789, 10.1148/radiol.2223010531 · DOI · Paper page
  17. Kass, 1988, Snakes: active contour models, Int. J. Comput. Vision., 1, 321, 10.1007/BF00133570 · DOI · Paper page
  18. Koenig, 1990, Relaxometry of brain: why white matter appears bright in MRI, Magn. Reson. Med., 14, 482, 10.1002/mrm.1910140306 · DOI · Paper page
  19. Labadie, 2014, Myelin water mapping by spatially regularized longitudinal relaxographic imaging at high magnetic fields, Magn. Reson. Med., 71, 375, 10.1002/mrm.24670 · DOI · Paper page
  20. Laule, 2004, Water content and myelin water fraction in multiple sclerosis, J. Neurol., 251, 284
  21. Lebel, 2010, Transverse relaxometry with stimulated echo compensation, Magn. Reson. Med., 64, 1005, 10.1002/mrm.22487 · DOI · Paper page
  22. Lenz, 2012, Feasibility of in vivo myelin water imaging using 3D multigradient-echo pulse sequences, Magn. Reson. Med., 68, 523, 10.1002/mrm.23241 · DOI
  23. Levesque, 2009, Characterizing healthy and diseased white matter using quantitative magnetization transfer and multicomponent T2 relaxometry: a unified view via a four-pool model, Magn. Reson. Med., 62, 1487, 10.1002/mrm.22131 · DOI · Paper page
  24. Li, 2010, Optimized inversion recovery sequences for quantitative T1 and magnetization transfer imaging, Magn. Reson. Med., 64, 491, 10.1002/mrm.22440 · DOI
  25. Mackay, 1994, In vivo visualization of myelin water in brain by magnetic resonance, Magn. Reson. Med., 31, 673, 10.1002/mrm.1910310614 · DOI · Paper page
  26. Menon, 1992, Proton relaxation studies of water compartmentalization in a model neurological system, Magn. Reson. Med., 28, 264, 10.1002/mrm.1910280208 · DOI · Paper page
  27. Mezer, 2013, Quantifying the local tissue volume and composition in individual brains with magnetic resonance imaging, Nature Med., 19, 1667, 10.1038/nm.3390 · DOI · Paper page
  28. Odrobina, 2005, MR properties of excised neural tissue following experimentally induced demyelination, NMR Biomed., 18, 277, 10.1002/nbm.951 · DOI · Paper page
  29. Oh, 2013, Direct visualization of short transverse relaxation time component (ViSTa), NeuroImage, 83, 485, 10.1016/j.neuroimage.2013.06.047 · DOI · Paper page
  30. Prasloski, 2012, Applications of stimulated echo correction to multicomponent T2 analysis, Magn. Reson. Med., 67, 1803, 10.1002/mrm.23157 · DOI · Paper page
  31. Russell-Schulz, 2013, What causes the hyperintense T 2-weighting and increased short T 2 signal in the corticospinal tract?, Magn. Reson. Imaging, 31, 329, 10.1016/j.mri.2012.07.003 · DOI
  32. Schmierer, 2007, Quantitative magnetization transfer imaging in postmortem multiple sclerosis brain, J. Magn. Reson. Imaging, 26, 41, 10.1002/jmri.20984 · DOI · Paper page
  33. Sled, 2004, Regional variations in normal brain shown by quantitative magnetization transfer imaging, Magn. Reson. Med., 51, 299, 10.1002/mrm.10701 · DOI · Paper page
  34. Sled, 2001, Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI, Magn. Reson. Med., 46, 923, 10.1002/mrm.1278 · DOI · Paper page
  35. Stikov, 2015, In vivo histology of the myelin g-ratio with magnetic resonance imaging, NeuroImage, 118, 397, 10.1016/j.neuroimage.2015.05.023 · DOI · Paper page
  36. Stikov, 2010, Bound pool fractions complement diffusion measures to describe white matter micro and macrostructure, NeuroImage, 54, 1112, 10.1016/j.neuroimage.2010.08.068 · DOI · Paper page
  37. Tang, 1997, A stereological method for estimating the total length and size of myelin fibers in human brain white matter, J. Neurosci. Methods, 73, 193, 10.1016/S0165-0270(97)02228-0 · DOI
  38. Travis, 2005, Selective excitation of myelin water using inversion-recovery-based preparations, Magn. Reson. Med., 54, 743, 10.1002/mrm.20606 · DOI
  39. Underhill, 2011, Fast bound pool fraction imaging of the in vivo rat brain: association with myelin content and validation in the C6 glioma model, NeuroImage, 54, 2052, 10.1016/j.neuroimage.2010.10.065 · DOI · Paper page
  40. van Gelderen, 2016, Effects of magnetization transfer on T1 contrast in human brain white matter, NeuroImage, 128, 85, 10.1016/j.neuroimage.2015.12.032 · DOI
  41. Webb, 2003, Is multicomponent T2 a good measure of myelin content in peripheral nerve?, Magn. Reson. Med., 49, 638, 10.1002/mrm.10411 · DOI · Paper page
  42. West, 2016, A revised model for estimating g-ratio from MRI, NeuroImage, 125, 1155, 10.1016/j.neuroimage.2015.08.017 · DOI · Paper page
  43. Whittall, 1989, Quantitative interpretation of NMR relaxation data, J. Magn. Reson., 84, 134
  44. Whittall, 1997, In vivo measurement of T2 distributions and water contents in normal human brain, Magn. Reson. Med., 37, 34, 10.1002/mrm.1910370107 · DOI · Paper page
  45. Wolff, 1989, Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo, Magn. Reson. Med., 10, 135, 10.1002/mrm.1910100113 · DOI · Paper page
  46. Zimmerman, 1957, Nuclear magnetic resonance studies in multiple phase systems: lifetime of a water molecule in an adsorbing phase on silica gel, J. Phys. Chem., 61, 1328, 10.1021/j150556a015 · doi:10.1021/j150556a015

Cited by

Metadata

Authors
West, K. L., Kelm, N. D., Carson, R. P., Gochberg, D. F., Ess, K. C., & Does, M. D.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2018-11
Volume
182
Pages
511-521
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2561469876
Cited by
79
References
8
FWCI
6.57
Type
journal article
Language
en
Open access
bronze
Funders
  • National Institutes of Health (CA68485, DK20593, DK58404, DK59637, EY08126)
  • The Ministry of Economic Affairs and Employment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.