The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Non-invasive textile based colorimetric sensor for the simultaneous detection of sweat pH and lactate
Abstract
A non-invasive textile-based colorimetric sensor for the simultaneous detection of sweat pH and lactate was created by depositing of three different layers onto a cotton fabric: 1.) chitosan, 2.) sodium carboxymethyl cellulose, and 3.) indicator dye or lactate assay. This sensor was characterized using field emission scanning electron microscopy and fourier transform infrared spectroscopy. Then, this sensor was used to measure pH and lactate concentration using the same sweat sample. The sensing element for sweat pH was composed of a mixture of methyl orange and bromocresol green while a lactate enzymatic assay was chosen for the lactate sensor. The pH indicator gradually shifted from red to blue as the pH increased, whereas the purple color intensity increased with the concentration of lactate in the sweat. By comparing these colors with a standard calibration, this platform can be used to estimate the sweat pH (1-14) and the lactate level (0-25 mM). Fading of the colors of this sensor was prevented by using cetyltrimethylammonium bromide (CTAB). The flexibility of this textile based sensor allows it to be incorporated into sport apparels and accessories hence potentially enabling real-time and continuous monitoring of sweat pH and lactate. This non-invasive sensing platform might open a new avenue for personal health monitoring and medical diagnosis as well as for determining of the physiological conditions of endurance athletes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of chitin and chitosan applications
Ravi Kumar, M. N. V. (2000) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(00)00038-9 · Cited by 6,009
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Characterization of cotton fabric scouring by FT-IR ATR spectroscopy
CHUNG, C., LEE, M., & CHOE, E. (2004) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2004.08.005 · Cited by 683
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Ren, J., Wang, C., Zhang, X., Carey, T., Chen, K., Yin, Y., & Torrisi, F. (2017) · Carbon · doi:10.1016/j.carbon.2016.10.045 · Cited by 365
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 300
Lactate in human sweat: a critical review of research to the present day
Derbyshire, P. J., Barr, H., Davis, F., & Higson, S. P. J. (2012) · The Journal of Physiological Sciences · doi:10.1007/s12576-012-0213-z · Cited by 280
Sweat: A sample with limited present applications and promising future in metabolomics
Mena-Bravo, A., & Luque de Castro, M. D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.10.048 · Cited by 235
Recent Developments in Sweat Analysis and Its Applications
Jadoon, S., Karim, S., Akram, M. R., Kalsoom Khan, A., Zia, M. A., Siddiqi, A. R., & Murtaza, G. (2015) · International Journal of Analytical Chemistry · doi:10.1155/2015/164974 · Cited by 216
Curto, V. F., Fay, C., Coyle, S., Byrne, R., O’Toole, C., Barry, C., Hughes, S., Moyna, N., Diamond, D., & Benito-Lopez, F. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.06.048 · Cited by 213
Roda, A., Guardigli, M., Calabria, D., Calabretta, M. M., Cevenini, L., & Michelini, E. (2014) · The Analyst · doi:10.1039/c4an01612b · Cited by 205
Acute effects of dehydration on sweat composition in men during prolonged exercise in the heat
Morgan, R. M., Patterson, M. J., & Nimmo, M. A. (2004) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.2004.01305.x · Cited by 192
Caldara, M., Colleoni, C., Guido, E., Re, V., & Rosace, G. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.08.073 · Cited by 182
Adsorption of Methyl Orange onto Chitosan from Aqueous Solution
Saha, T., Bhoumik, N. C., Karmaker, S., Ahmed, M. G., Ichikawa, H., & Fukumori, Y. (2010) · Journal of Water Resource and Protection · doi:10.4236/jwarp.2010.210107 · Cited by 155
Recent progress in flexible and wearable bio-electronics based on nanomaterials
Yang, Y., Xiang-Dong, Y., Tan, Y., & Yuan, Q. (2017) · Nano Research · doi:10.1007/s12274-017-1476-8 · Cited by 115
Embroidered electrochemical sensors for biomolecular detection
Liu, X., & Lillehoj, P. B. (2016) · Lab on a Chip · doi:10.1039/c6lc00307a · Cited by 110
Lamas‐Ardisana, P. J., Loaiza, Ó. A., Añorga, L., Jubete, E., Borghei, M., Ruiz, V., Ochoteco, E., Cabañero, G., & Grande, H. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.01.047 · Cited by 107
Toh, H. S., Batchelor‐McAuley, C., Tschulik, K., & Compton, R. G. (2013) · The Analyst · doi:10.1039/c3an00843f · Cited by 99
Cai, X., Yan, J., Chu, H., Wu, M., & Tu, Y. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.10.002 · Cited by 71
Ion Sensor for the Quantification of Sodium in Sweat Samples
Wujcik, E. K., Blasdel, N. J., Trowbridge, D., & Monty, C. N. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2257168 · Cited by 56
Real-time colorimetric hydration sensor for sport activities
Zhou, Y., Han, H., Naw, H. P. P., Lammy, A. V., Goh, C. H., Boujday, S., & Steele, T. W. J. (2015) · Materials & Design · doi:10.1016/j.matdes.2015.06.078 · Cited by 49
An animal cell culture monitoring system using a smartphone-mountable paper-based analytical device
Im, S. H., Kim, K. R., Park, Y. M., Yoon, J. H., Hong, J. W., & Yoon, H. C. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.121 · Cited by 47
Na+/H+ exchangers in the human eccrine sweat duct
Granger, D., Marsolais, M., Burry, J., & Laprade, R. (2003) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00581.2002 · Cited by 41
Andrus, L. P., Unruh, R. M., Wisniewski, N. A., & McShane, M. J. (2015) · Biosensors · doi:10.3390/bios5030398 · Cited by 39
Microfluidic device on a nonwoven fabric: A potential biosensor for lactate detection
Baysal, G., Önder, S., Göcek, İ., Trabzon, L., Kızıl, H., Kök, F. N., & Karaguzel, B. (2014) · Textile Research Journal · doi:10.1177/0040517514528565 · Cited by 38
Urban, G. A., & Weiss, T. (2009) · Springer series on chemical sensors and biosensors · doi:10.1007/978-3-540-75645-3_6 · Cited by 35
Cited by
Recent Developments of Carboxymethyl Cellulose
Rahman, M. S., Hasan, M. S., Nitai, A. S., Nam, S., Karmakar, A. K., Ahsan, M. S., Shiddiky, M. J. A., & Ahmed, M. B. (2021) · Polymers · doi:10.3390/polym13081345 · Cited by 882
Functional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Integrated textile sensor patch for real-time and multiplex sweat analysis
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F., & Zhang, Y. (2019) · Science Advances · doi:10.1126/sciadv.aax0649 · Cited by 564
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
Metadata
- Authors
- Promphet, N., Rattanawaleedirojn, P., Siralertmukul, K., Soatthiyanon, N., Potiyaraj, P., Thanawattano, C., Hinestroza, J. P., & Rodthongkum, N.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 192
- Pages
- 424-430
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2894090929
- Cited by
- 254
- References
- 33
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.