Molecularly imprinted polymer based electrochemical biosensors: Overcoming the challenges of detecting vital biomarkers and speeding up diagnosis
Open accessThe DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Abstract
Electrochemical biosensors for the detection of vital biomarkers is a well-established technology that utilises a transducer and recognition element in tandem to determine the presence of an analyte. There is growing interest in using Molecularly Imprinted Polymers (MIPs) as recognition elements in a wide range of sensing devices due to their economic viability and scalability. The inherent properties of polymer platforms, alongside the vast array of monomeric options, synthetic routes and incorporation strategies allow for the production of a multitude of sensitive and selective recognition elements that have significant advantages over classically utilised biological entities. MIPs exhibit superior chemical and thermal stability offering a wider variety of immobilization/incorporation strategies, virtually unlimited ambient shelf-life and a longer product lifetime, whilst the vast array of monomers available offer flexibility to their synthesis. Even though some sensor platforms have been reported for the detection of vital biomarkers, the use of MIPs has a number of challenges and drawbacks that need to be overcome in order to produce sensing platforms with the required sensitivity and specificity for clinical use. In this review, we will provide an overview of the reasoning behind using MIPs as recognition elements in electrochemical biosensors for vital biomarkers, discuss the problems synergizing MIPs and electrochemical read-out strategies and offer insights into the future perspectives of this promising and innovative technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kumar, A., Roberts, D., Wood, K. E., Light, B., Parrillo, J. E., Sharma, S., Suppes, R., Feinstein, D., Zanotti, S., Taiberg, L., et al. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000217961.75225.e9 · Cited by 6,109
Antman, E., Bassand, J.-P., Klein, W., Ohman, M., Lopez Sendon, J. L., Rydén, L., Simoons, M., & Tendera, M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00804-4 · Cited by 4,821
Fourth Universal Definition of Myocardial Infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., & White, H. D. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.1038 · Cited by 4,118
Fleischmann, C., Scherag, A., Adhikari, N. K. J., Hartog, C. S., Tsaganos, T., Schlattmann, P., Angus, D. C., & Reinhart, K. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201504-0781oc · Cited by 3,548
Sepsis in European intensive care units: Results of the SOAP study*
Vincent, J.-L., Sakr, Y., Sprung, C. L., Ranieri, V. M., Reinhart, K., Gerlach, H., Moreno, R., Carlet, J., Le Gall, J.-R., & Payen, D. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000194725.48928.3a · Cited by 2,836
Third Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., White, H. D., Thygesen, K., Alpert, J. S., White, H. D., Jaffe, A. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.001 · Cited by 2,621
Polydopamine Surface Chemistry: A Decade of Discovery
Ryu, J. H., Messersmith, P. B., & Lee, H. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b19865 · Cited by 1,843
Biomarkers in Cancer Staging, Prognosis and Treatment Selection
Ludwig, J. A., & Weinstein, J. N. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1739 · Cited by 1,666
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Pierrakos, C., & Vincent, J.-L. (2010) · Critical Care · doi:10.1186/cc8872 · Cited by 1,377
Early lactate clearance is associated with improved outcome in severe sepsis and septic shock*
Nguyen, H. B., Rivers, E. P., Knoblich, B. P., Jacobsen, G., Muzzin, A., Ressler, J. A., & Tomlanovich, M. C. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000132904.35713.a7 · Cited by 1,228
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
de Jong, E., van Oers, J. A., Beishuizen, A., Vos, P., Vermeijden, W. J., Haas, L. E., Loef, B. G., Dormans, T., van Melsen, G. C., Kluiters, Y. C., et al. (2016) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(16)00053-0 · Cited by 836
Electrochemical impedance spectroscopy: an overview of bioanalytical applications
Randviir, E. P., & Banks, C. E. (2013) · Analytical Methods · doi:10.1039/c3ay26476a · Cited by 795
Self-citationThe Aarhus statement: improving design and reporting of studies on early cancer diagnosis
Weller, D., Vedsted, P., Rubin, G., Walter, F. M., Emery, J., Scott, S., Campbell, C., Andersen, R. S., Hamilton, W., Olesen, F., et al. (2012) · British Journal of Cancer · doi:10.1038/bjc.2012.68 · Cited by 779
Synthesis of substrate‐selective polymers by host‐guest polymerization
Arshady, R., & Mosbach, K. (1981) · Die Makromolekulare Chemie · doi:10.1002/macp.1981.021820240 · Cited by 715
The rational development of molecularly imprinted polymer-based sensors for protein detection
Whitcombe, M. J., Chianella, I., Larcombe, L., Piletsky, S. A., Noble, J., Porter, R., & Horgan, A. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00049c · Cited by 711
Novel Multifunctional Polymers from Aromatic Diamines by Oxidative Polymerizations
Li, X.-G., Huang, M.-R., Duan, W., & Yang, Y.-L. (2002) · Chemical Reviews · doi:10.1021/cr010423z · Cited by 682
Faix, J. D. (2013) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2013.764490 · Cited by 663
Molecularly Imprinted Polymers in Electrochemical and Optical Sensors
Ahmad, O. S., Bedwell, T. S., Esen, C., Garcia-Cruz, A., & Piletsky, S. A. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.08.009 · Cited by 602
Recent advances in biosensor development for the detection of cancer biomarkers
Jayanthi, V. S. P. K. S. A., Das, A. B., & Saxena, U. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.014 · Cited by 565
Molecularly-imprinted polymer sensors: realising their potential
Uzun, L., & Turner, A. P. F. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.013 · Cited by 535
Reichlin, T., Irfan, A., Twerenbold, R., Reiter, M., Hochholzer, W., Burkhalter, H., Bassetti, S., Steuer, S., Winkler, K., Peter, F., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.023937 · Cited by 460
Cardiac Troponin for Assessment of Myocardial Injury in COVID-19
Sandoval, Y., Januzzi, J. L., & Jaffe, A. S. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.06.068 · Cited by 438
Brain natriuretic peptide: A marker of myocardial dysfunction and prognosis during severe sepsis
Charpentier, J., Luyt, C.-E., Fulla, Y., Vinsonneau, C., Cariou, A., Grabar, S., Dhainaut, J.-F., Mira, J.-P., & Chiche, J.-D. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114827.93410.d8 · Cited by 429
Solid-phase synthesis of molecularly imprinted nanoparticles
Canfarotta, F., Poma, A., Guerreiro, A., & Piletsky, S. (2016) · Nature Protocols · doi:10.1038/nprot.2016.030 · Cited by 407
Wackerlig, J., & Schirhagl, R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03804 · Cited by 403
From 3D to 2D: A Review of the Molecular Imprinting of Proteins
Turner, N. W., Jeans, C. W., Brain, K. R., Allender, C. J., Hlady, V., & Britt, D. W. (2006) · Biotechnology Progress · doi:10.1002/bp060122g · Cited by 396
Brentnall, T. A., Bronner, M. P., Byrd, D. R., Haggitt, R. C., & Kimmey, M. B. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-4-199908170-00003 · Cited by 391
Point-of-care biosensor systems for cancer diagnostics/prognostics
Soper, S. A., Brown, K., Ellington, A., Frazier, B., Garcia-Manero, G., Gau, V., Gutman, S. I., Hayes, D. F., Korte, B., Landers, J. L., et al. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.006 · Cited by 376
Recent trends in antibody based sensors
Holford, T. R. J., Davis, F., & Higson, S. P. J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.023 · Cited by 352
Impedimetric immunosensors—A review
Prodromidis, M. I. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2009.01.081 · Cited by 347
Jolly, P., Tamboli, V., Harniman, R. L., Estrela, P., Allender, C. J., & Bowen, J. L. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.043 · Cited by 286
Electrochemical Sensors Based on Molecularly Imprinted Polymers
Piletsky, S. A., & Turner, A. P. F. (2002) · Electroanalysis · doi:10.1002/1521-4109(200203)14:5<317::aid-elan317>3.0.co;2-5 · Cited by 282
Diagnostic markers of acute myocardial infarction
MYTHILI, S., & MALATHI, N. (2015) · Biomedical Reports · doi:10.3892/br.2015.500 · Cited by 249
Crapnell, R. D., Hudson, A. D., Foster, C. W., Eersels, K., van Grinsven, B., Cleij, T. J., Banks, C. E., & Peeters, M. (2019) · Sensors · doi:10.3390/s19051204 · Cited by 241
Self-citationFabricated aptamer-based electrochemical “signal-off” sensor of ochratoxin A
Kuang, H., Chen, W., Xu, D., Xu, L., Zhu, Y., Liu, L., Chu, H., Peng, C., Xu, C., & Zhu, S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.06.058 · Cited by 221
Fuchs, Y., Soppera, O., & Haupt, K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.12.026 · Cited by 220
Apple, F. S., Pearce, L. A., Smith, S. W., Kaczmarek, J. M., & Murakami, M. M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.114728 · Cited by 212
Russell, C., Ward, A. C., Vezza, V., Hoskisson, P., Alcorn, D., Steenson, D. P., & Corrigan, D. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.11.053 · Cited by 193
Recent advances in biosensors for diagnosis and detection of sepsis: A comprehensive review
Kumar, S., Tripathy, S., Jyoti, A., & Singh, S. G. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.034 · Cited by 180
Cost of care for cancer patients in England: evidence from population-based patient-level data
Laudicella, M., Walsh, B., Burns, E., & Smith, P. C. (2016) · British Journal of Cancer · doi:10.1038/bjc.2016.77 · Cited by 178
Integrated Biosensor for Rapid and Point-of-Care Sepsis Diagnosis
Min, J., Nothing, M., Coble, B. W., Zheng, H., Park, J., Im, H., Weber, G. F., Castro, C. M., Świrski, F. K., Weissleder, R., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b08965 · Cited by 162
Ahmed, M. U., Hossain, M. M., Safavieh, M., Wong, Y. L., Rahman, I. A., Zourob, M., & Tamiya, E. (2015) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.992387 · Cited by 161
Boeddinghaus, J., Twerenbold, R., Nestelberger, T., Badertscher, P., Wildi, K., Puelacher, C., du Fay de Lavallaz, J., Keser, E., Rubini Giménez, M., Wussler, D., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2018.286906 · Cited by 158
Breast cancer biomarker (HER2-ECD) detection using a molecularly imprinted electrochemical sensor
Pacheco, J. G., Rebelo, P., Freitas, M., Nouws, H. P. A., & Delerue-Matos, C. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.06.113 · Cited by 158
Nonenzymatic Sensor for Lactate Detection in Human Sweat
Zaryanov, N. V., Nikitina, V. N., Karpova, E. V., Karyakina, E. E., & Karyakin, A. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03662 · Cited by 154
Liu, X., Ren, J. Y., Su, L., Gao, X. P., Tang, Y., Ma, T., Zhu, L., & Li, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.051 · Cited by 146
Cardiac markers and their point-of-care testing for diagnosis of acute myocardial infarction
Yang, Z., & Zhou, D. M. (2006) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2006.05.011 · Cited by 141
Ribeiro, J. A., Pereira, C. M. D. M., Silva, F., & Sales, M. G. F. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.03.011 · Cited by 133
Silva, B. V. M., Rodríguez, B. A. G., Sales, M. G. F., Sotomayor, M. D. P. T., & Dutra, R. F. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.068 · Cited by 124
Phonklam, K., Wannapob, R., Sriwimol, W., Thavarungkul, P., & Phairatana, T. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127630 · Cited by 123
Core–shell molecularly imprinted particles
Wan, L., Chen, Z., Huang, C., & Shen, X. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.08.010 · Cited by 100
Ribeiro, J. A., Pereira, C. M. D. M., Silva, F., & Sales, M. G. F. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.05.017 · Cited by 95
Future trends in the market for electrochemical biosensing
Neves, M. M. P. S., González-García, M. B., Hernández‐Santos, D., & Fanjul‐Bolado, P. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.05.002 · Cited by 91
Electrochemical sensing using boronic acids
Li, M., Zhu, W., Marken, F., & James, T. D. (2015) · Chemical Communications · doi:10.1039/c5cc04976h · Cited by 91
Moreira, F. T. C., Dutra, R. F., Noronha, J. P., Cunha, A. L., & Sales, M. G. F. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.026 · Cited by 83
Šljukić, B., Banks, C. E., Salter, C., Crossley, A., & Compton, R. G. (2006) · The Analyst · doi:10.1039/b601299j · Cited by 73
Self-citationLiu, X., Lin, W., Xiao, P., Yang, M., Sun, L., Zhang, Y., Xue, W., & Guan, B. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124074 · Cited by 71
Kaffarnik, M. F., Lock, J. F., Vetter, H., Ahmadi, N., Lojewski, C., Malinowski, M. B., Neuhaus, P., & Stockmann, M. (2013) · Critical Care · doi:10.1186/cc13089 · Cited by 71
Casadio, S., Lowdon, J. W., Betlem, K., Ueta, J. T., Foster, C. W., Cleij, T. J., van Grinsven, B., Sutcliffe, O. B., Banks, C. E., & Peeters, M. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.01.050 · Cited by 69
Self-citationKumar, D., & Prasad, B. B. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.06.053 · Cited by 68
Alizadeh, T., Nayeri, S., & Mirzaee, S. (2018) · Talanta · doi:10.1016/j.talanta.2018.08.027 · Cited by 62
Jamieson, O. D., Soares, T. C. C., de Faria, B. D. A., Hudson, A. D., Mecozzi, F., Rowley‐Neale, S. J., Banks, C. E., Gruber, J., Novakovic, K., Peeters, M., et al. (2019) · Chemosensors · doi:10.3390/chemosensors8010005 · Cited by 61
Self-citationBerghuis, A., Koffijberg, H., Prakash, J., Terstappen, L. W. M. M., & IJzerman, M. J. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18020363 · Cited by 53
Early Diagnosis and Evidence-Based Care of Surgical Sepsis
Moore, L. J., & Moore, F. A. (2011) · Journal of Intensive Care Medicine · doi:10.1177/0885066611408690 · Cited by 46
Betlem, K., Mahmood, I., Seixas, R. D., Sadiki, I., Raimbault, R. L. D., Foster, C. W., Crapnell, R. D., Tedesco, S., Banks, C. E., Gruber, J., et al. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.11.114 · Cited by 46
Self-citationChristenson, R. H., Jacobs, E., Uettwiller-Geiger, D. L., Estey, M. P., Lewandrowski, K. B., Koshy, T. I., Kupfer, K., Li, Y., & Wesenberg, J. C. (2017) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2016.022640 · Cited by 41
Biomimetic Polymer-Based Method for Selective Capture of C-Reactive Protein in Biological Fluids
Wang, Q., Jin, H., Xia, D., Shao, H., Peng, K., Liu, X., Huang, H., Zhang, Q., Guo, J., Wang, Y., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b15581 · Cited by 34
Understanding cardiac troponin part 1: avoiding troponinitis
Body, R. M., & Carlton, E. W. (2017) · Emergency Medicine Journal · doi:10.1136/emermed-2017-206812 · Cited by 23
Somani, S., Chng, C., & Verma, C. S. (2007) · Proteins Structure Function and Bioinformatics · doi:10.1002/prot.21320 · Cited by 19
Sun, Y., Yang, Y., Li, S., Wang, W., Feng, X., Zhao, M., & Liu, Y. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0231914jes · Cited by 9
Understanding cardiac troponin part 2: early rule out of acute coronary syndrome
Carlton, E. W., & Body, R. M. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2017-207161 · Cited by 4
Cited by
Screen-printed electrodes: Transitioning the laboratory in-to-the field
García-Miranda Ferrari, A., Rowley-Neale, S. J., & Banks, C. E. (2021) · Talanta Open · doi:10.1016/j.talo.2021.100032 · Cited by 315
Self-citationRecent advances in molecularly imprinted polymer-based electrochemical sensors
Li, Y., Luo, L., Kong, Y., Li, Y., Wang, Q., Wang, M., Li, Y., Davenport, A., & Li, B. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116018 · Cited by 308
Kadhem, A. J., Gentile, G. J., & Fidalgo de Cortalezzi, M. M. (2021) · Molecules · doi:10.3390/molecules26206233 · Cited by 178
“Other large molecules of interest for which MIP electrochemical biosensors have been reported are the clinical biomarkers for diagnosis of cancer and other cardiovascular diseases [208].”
Background
Metadata
- Authors
- Crapnell, R. D., Dempsey-Hibbert, N. C., Peeters, M., Tridente, A., & Banks, C. E.
- Venue
- Talanta Open
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 2
- Pages
- 100018
- ISSN
- 2666-8319 (ISSN-L)
- OpenAlex
- W3097804025
- Cited by
- 177
- References
- 73
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.