The reliability, validity, and stability of a measure of physical activity in the elderly
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess the reliability, validity, and stability of an accelerometer-based monitor of physical activity in an elderly population. DESIGN: Six studies were conducted to assess the Tritrac, a newly available accelerometer capable of storing three-dimensional activity data collected in minute epochs. After initial bench testing, the waist-worn devices were assessed for test-retest reliability during sitting and treadmill walking at 1mph and 2mph. Validity testing examined the Tritrac's ability to discriminate between different levels of physical activity and also compared the Tritrac with an established wrist-worn acclerometer, the Actigraph. Stability of the measure was examined over a period of 3 to 7 days, and in a subset of subjects this measurement was performed for a second week. SETTING AND SUBJECTS: Residents of a VA Nursing Home (n = 40; mean age = 76), participants in an in-home nonaerobic exercise program (n = 36; mean age = 77), and community participants in an aerobic exercise program (n = 10; mean age = 71). RESULTS: Intraclass correlation coefficients (ICC) for both the bench testing and test-retest reliability were .97. The device discriminated among subjects independently categorized as sedentary, moderately active, or active (F = 49.4, p = .0001) and between specific activities of varying intensity (F = 114.5, p = .0001). Tritrac and Actigraph measurement comparison showed a correlation of r = .77, p = .0001. Stability of the measure was demonstrated by ICCs = .81 and .78 for mean activity values and proportion of time spent in sedentary activity, respectively. No significant differences were observed when comparing activity measured for two separate weeks. CONCLUSION: The Tritrac is a reliable and valid instrument producing activity measurement that was stable over time in the elderly population we studied. During our longitudinal testing, 20% of the subjects did not comply with wearing the device; this noncompliance issue must be considered in any use of the Tritrac.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A short questionnaire for the measurement of habitual physical activity in epidemiological studies
Baecke, J., Burema, J., & Frijters, J. (1982) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/36.5.936 · Cited by 3,945
The physical activity scale for the elderly (PASE): Development and evaluation
Washburn, R. A., Smith, K. W., Jette, A. M., & Janney, C. A. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90053-4 · Cited by 3,177
BLAIR, S. N., HASKELL, W. L., HO, P., PAFFENBARGER, R. S., VRANIZAN, K. M., FARQUHAR, J. W., & WOOD, P. D. (1985) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a114163 · Cited by 1,104
Comparison of activity levels using the Caltrac?? accelerometer and five questionnaires
MILLER, D. J., FREEDSON, P. S., & KLINE, G. M. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199403000-00016 · Cited by 402
Physiology and Complications of Bed Rest
Harper, C. M., & Lyles, Y. M. (1988) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1988.tb04375.x · Cited by 361
Effects of lower limb unloading on skeletal muscle mass and function in humans
Berg, H. E., Dudley, G. A., Haggmark, T., Ohlsen, H., & Tesch, P. A. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.4.1882 · Cited by 257
PATTERSON, S. M., KRANTZ, D. S., MONTGOMERY, L. C., DEUSTER, P. A., HEDGES, S. M., & NEBEL, L. E. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb03356.x · Cited by 179
Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure
PAMBIANCO, G., WING, R. R., & ROBERTSON, R. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199012000-00020 · Cited by 93
A Method of Studying Physical Activity in Man
STUNKARD, S. (1960) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/8.5.595 · Cited by 66
Lower mobility and markers of bone resorption in the elderly
Lips, P. T. A. M., van Ginkel, F. C., Netelenbos, J. C., Wiersinga, A., & van der Vijgh, W. J. F. (1990) · Bone and Mineral · doi:10.1016/0169-6009(90)90099-2 · Cited by 65
Cited by
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Mercer, K., Giangregorio, L., Schneider, E., Chilana, P., Li, M., & Grindrod, K. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.4225 · Cited by 419
“However, activity trackers may be less accurate for older adults with a shuffling, abnormal, or slow gait caused by conditions such as stroke or Parkinson’s disease [31-34].”
A comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Accelerometer-based measures in physical activity surveillance: current practices and issues
Pedišić, Ž., & Bauman, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093407 · Cited by 330
How Active Are People With Stroke?: Use of Accelerometers to Assess Physical Activity
Rand, D., Eng, J. J., Tang, P.-F., Jeng, J.-S., & Hung, C. (2009) · Stroke · doi:10.1161/strokeaha.108.523621 · Cited by 325
Quantitating Physical Activity in COPD Using a Triaxial Accelerometer
Steele, B. G., Holt, L., Belza, B., Ferris, S., Lakshminaryan, S., & Buchner, D. M. (2000) · Chest · doi:10.1378/chest.117.5.1359 · Cited by 287
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Sumukadas, D., Witham, M. D., Struthers, A. D., & McMurdo, M. E. T. (2007) · Canadian Medical Association Journal · doi:10.1503/cmaj.061339 · Cited by 246
“Current smoker 10 (15) 8 (12) 6 (13) 7 (14)”
Pedometer Accuracy in Nursing Home and Community-Dwelling Older Adults
CYARTO, E. V., MYERS, A. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113476.62469.98 · Cited by 236
Uswatte, G., Miltner, W. H. R., Foo, B., Varma, M., Moran, S., & Taub, E. (2000) · Stroke · doi:10.1161/01.str.31.3.662 · Cited by 232
Witham, M. D., Crighton, L. J., Gillespie, N. D., Struthers, A. D., & McMurdo, M. E. T. (2010) · Circulation Heart Failure · doi:10.1161/circheartfailure.109.907899 · Cited by 224
Physical Activity, Health Impairments, and Disability in Neuromuscular Disease
McDonald, C. M. (2002) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200211001-00012 · Cited by 224
“This is relevant when considering the use of these devices in a disabled population with gait disorders.(74) In addition, available pedometers provide information regarding total steps or distance traveled, but no minute-tominute information regarding the frequency, duration, or intensity of activity.”
BackgroundKowalski, K., Rhodes, R., Naylor, P.-J., Tuokko, H., & MacDonald, S. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-148 · Cited by 212
“Eleven studies compared indirect measures with other indirect PA measures [16,32,33,37,45,47,48,5154] and fourteen studies compared direct measures with other direct PA measures [38,41,43,55-65].”
BackgroundMethodInfluentialAkhavian, R., & Behzadan, A. H. (2015) · Advanced Engineering Informatics · doi:10.1016/j.aei.2015.03.001 · Cited by 212
Using Activity Monitors to Measure Physical Activity in Free-Living Conditions
Berlin, J. E., Storti, K. L., & Brach, J. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1137 · Cited by 209
Unobtrusive assessment of activity patterns associated with mild cognitive impairment
Hayes, T. L., Abendroth, F., Adami, A., Pavel, M., Zitzelberger, T. A., & Kaye, J. A. (2008) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2008.07.004 · Cited by 187
“Previous studies of activity in the home have used wrist-worn actigraphs to quantify movement in the home [39,40].”
BackgroundMicroprocessor-based ambulatory activity monitoring in stroke patients
MACKO, R. F., HAEUBER, E., SHAUGHNESSY, M., COLEMAN, K. L., BOONE, D. A., SMITH, G. V., & SILVER, K. H. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200203000-00002 · Cited by 185
Steele, B. G., Belza, B., Cain, K., Warms, C., Coppersmith, J., & Howard, J. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.10.0045 · Cited by 176
“More recently, digital pedometers and accelerometers have shown promise as adjuncts to reinforce exercise adherence by allowing self-monitoring, and as process and outcome measures for physical conditioning programs [23,28,35,40].”
BackgroundResultWearable systems for monitoring mobility-related activities in older people: a systematic review
de Bruin, E. D., Hartmann, A., Uebelhart, D., Murer, K., & Zijlstra, W. (2008) · Clinical Rehabilitation · doi:10.1177/0269215508090675 · Cited by 170
Position-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165
Physical activity in daily life in patients with chronic low back pain
Verbunt, J. A., Westerterp, K. R., van der Heijden, G. J., Seelen, H. A., Vlaeyen, J. W., & Knottnerus, J. A. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.23182 · Cited by 162
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
McMurdo, M. E. T., Price, R. J. G., Shields, M., Potter, J., & Stott, D. J. (2009) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2009.02568.x · Cited by 76
Vanroy, C., Vissers, D., Cras, P., Beyne, S., Feys, H., Vanlandewijck, Y., & Truijen, S. (2014) · Disability and Rehabilitation · doi:10.3109/09638288.2013.859307 · Cited by 46
Metadata
- Authors
- Kochersberger, G., McConnell, E., Kuchibhatla, M. N., & Pieper, C.
- Venue
- Archives of Physical Medicine and Rehabilitation
- Publisher
- Elsevier BV
- Published
- 1996-08
- Volume
- 77
- Issue
- 8
- Pages
- 793-795
- ISSN
- 0003-9993 (ISSN-L)
- OpenAlex
- W1982878402
- Cited by
- 159
- References
- 15
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.