Dependence of yield strain of human trabecular bone on anatomic site
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Understanding the dependence of human trabecular bone strength behavior on anatomic site provides insight into structure-function relationships and is essential to the increased success of site-specific finite element models of whole bones. To investigate the hypothesis that the yield strains of human trabecular bone depend on anatomic site, the uniaxial tensile and compressive yield properties were compared for cylindrical specimens from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27) taken from 61 donors (67+/-15years). Test protocols were used that minimized end artifacts and loaded specimens along the main trabecular orientation. Yield strains by site (mean+/-S.D.) ranged from 0.70+/-0.05% for the trochanter to 0.85+/-0.10% for the femoral neck in compression, from 0.61+/-0.05% for the trochanter to 0.70+/-0.05% for the vertebra in tension, and were always higher in compression than tension (p<0.001). The compressive yield strain was higher for the femoral neck than for all other sites (p<0.001), as was the tensile yield strain for the vertebra (p<0.007). Analysis of covariance, with apparent density as the covariate, indicated that inter-site differences existed in yield stress even after adjusting statistically for density (p<0.035). Coefficients of variation in yield strain within each site ranged from only 5-12%, consistent with the strong linear correlations (r(2)=0.94-0.98) found between yield stress and modulus. These results establish that the yield strains of human trabecular bone can differ across sites, but that yield strain may be considered uniform within a given site despite substantial variation in elastic modulus and yield stress.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The volume fraction of trabecular bone varies from 60% in primary compressive group of femoral neck to less than 10% in the elderly spine (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
9 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718 · cited 1×
“Through advancements in imaging techniques and computational methods, it is now possible to create detailed anatomic site-specific finite element models of trabecular bone specimens (Kabel et al., 1999; Ulrich et al., 1999; Zysset et al., 1998) and whole bones (Keyak and Rossi, 2000; Lotz et al.”
MethodPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“, 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 6×
“Uniaxial compressive and tensile mechanical tests were conducted at room temperature using a servohydraulic load frame (858 Mini-Bionix, MTS, Eden Prairie, MN) following protocols designed to minimize end artifacts (Keaveny et al., 1994a; Kopperdahl and Keaveny, 1998).”
BackgroundMethodResultSelf-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 1×
“, 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al., 1997; Mosekilde et al., 1987) render the strength behavior of human trabecular bone of primary medical importance.”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432 · cited 1×
“The central role of trabecular bone in the etiology of whole bone fractures (Lotz and Hayes 1990; McBroom et al., 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al.”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431 · cited 1×
“tension) in yield strains across all anatomic sites supports previous suggestions of a similarity in the yield strains between trabecular and cortical tissue (Keaveny, 1997; Niebur et al., 2000).”
ResultSelf-citation
Research works printed but not linked: 1
- Niebur, G.L., Keaveny, T.M., 2001. Trabecular bone exhibits multiple failure surfaces in biaxial loading. Transactions on Orthopaedic Research Society 26.
Cited by
Items 201–300 of 732
Carpenter, R. D., Saeed, I., Bonaretti, S., Schreck, C., Keyak, J. H., Streeper, T., Harris, T. B., & Lang, T. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.06.010 · Cited by 41
Creep Does Not Contribute to Fatigue in Bovine Trabecular Bone
Moore, T. L. A., O’Brien, F. J., & Gibson, L. J. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1762892 · Cited by 37
Prevalence of Poor Bone Quality in Women Undergoing Spinal Fusion Using Biomechanical-CT Analysis
Burch, S., Feldstein, M., Hoffmann, P., & Keaveny, T. M. (2015) · Spine · doi:10.1097/brs.0000000000001175 · Cited by 38
Self-citationAjaxon, I., Acciaioli, A., Lionello, G., Ginebra, M., Öhman‐Mägi, C., Baleani, M., & Persson, C. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.06.023 · Cited by 36
Gustafsson, A., Tognini, M., Bengtsson, F., Gasser, T. C., Isaksson, H., & Grassi, L. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104118 · Cited by 36
Structure‐function relationships of the human vertebral endplate
Wu, Y., Loaiza, J., Banerji, R., Blouin, O., & Morgan, E. F. (2021) · JOR Spine · doi:10.1002/jsp2.1170 · Cited by 40
“ple, the ranges of BV/TV, apparent modulus and apparent yield stress we have found for the vertebral endplate are larger than those for trabecular bone and cortical bone at single anatomic sites (Table 4).(35,64)”
BackgroundSelf-citationAdams, C. R., Ammoun, R., Deeb, G. R., & Bencharit, S. (2022) · Journal of Prosthodontics · doi:10.1111/jopr.13503 · Cited by 36
Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength
Haider, I. T., Speirs, A., & Frei, H. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.004 · Cited by 36
Yazdanpanah, Z., Sharma, N. K., Raquin, A., Cooper, D. M. L., Chen, D., & Johnston, J. D. (2023) · BioMedical Engineering OnLine · doi:10.1186/s12938-023-01135-6 · Cited by 37
On the effect of marrow in the mechanical behavior and crush response of trabecular bone
Halgrin, J., Chaari, F., & Markiewicz, É. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.09.003 · Cited by 35
Egan, D. S., & Dowling, D. P. (2019) · Additive manufacturing · doi:10.1016/j.addma.2019.100890 · Cited by 35
González, F. J. Q., Steineman, B. D., Sturnick, D. R., Deland, J. T., Demetracopoulos, C. A., & Wright, T. M. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24876 · Cited by 35
“When transferring loads to the surrounding bone the implant must avoid overloading the bone, which could lead to bone failure and implant subsidence and loosening.(3) To ensure both adequate micro-”
BackgroundLloyd, A. A., Wang, Z. X., & Donnelly, E. L. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029046 · Cited by 40
“Finally, at the millimeter scale, bulk cancellous tissue can be compressed to assess apparent stiffness, yield stress, and ultimate strength [36].”
BackgroundInvestigation of bone inelastic response in interaction phenomena with dental implants
NATALI, A. N., Carniel, E. L., & Pavan, P. G. (2008) · Dental Materials · doi:10.1016/j.dental.2007.11.024 · Cited by 35
“6 by analyzing the slope of the post-elastic region of static loading tests [17,46,47].”
BackgroundProt, M., Saletti, D., Pattofatto, S., Bousson, V., & Laporte, S. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.002 · Cited by 38
“, 2011), anatomic localization (Morgan and Keaveny, 2001), and geometry (Linde et al.”
Calcium phosphate scaffolds mimicking the gradient architecture of native long bones
Lindner, M., Bergmann, C., Telle, R., & Fischer, H. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35038 · Cited by 35
Hsieh, A. H., Wagner, D. R., Cheng, L. Y.-C., & Lotz, J. C. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2073467 · Cited by 35
Beaupied, H., Dupuis, A., Arlettaz, A., Brunet-Imbault, B., Bonnet, N., Jaffré, C., Benhamou, C.-L., & Courteix, D. (2006) · Bio-Medical Materials and Engineering · doi:10.1177/09592989200601600401021 · Cited by 43
“To explain the lack of harmful effect due to the mode of conservation, one must consider that densit-ometric, architectural and biomechanical parameters are known to be linked [4,9,11,14,25].”
Nasiri, M., & Luo, Y. (2016) · Bone · doi:10.1016/j.bone.2016.06.006 · Cited by 38
“Then, isotropic inhomogeneousmaterial properties were derived from vBMD using the empirical equations of Morgan and colleagues [67,68]:”
MethodNumerical Investigation of Ti6Al4V Gradient Lattice Structures with Tailored Mechanical Response
Sierra, D. C. M., Astaraee, A. H., Guagliano, M., & Bagherifard, S. (2022) · Advanced Engineering Materials · doi:10.1002/adem.202101760 · Cited by 36
Kelly, N., Harrison, N. M., McDonnell, P., & McGarry, P. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-012-0434-3 · Cited by 38
“…the mechanical properties of trabecular bone, previous studies have primarily relied on uniaxial compression testing of representative samples of trabecular bone (Goldstein 1987; Røhl et al. 1991; Kopperdahl and Keaveny 1998; Morgan and Keaveny 2001; Keaveny et al. 1993; Keyak et al. 1996).”
BackgroundProt, M., Cloete, T. J., Saletti, D., & Laporte, S. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.02.021 · Cited by 38
“…have reported trabeculae behavior to be unaffected by the strain rate (Szabó et al., 2011), the general consensus is that cancellous bone behavior is strain rate dependent (Guedes et al., 2006), and can vary with anatomic location, among other factors (Morgan and Keaveny, 2001; Hulme et al., 2007).”
BackgroundMethodGroenen, K. H. J., Bitter, T., van Veluwen, T. C. G., van der Linden, Y. M., Verdonschot, N. J. J., Tanck, E., & Janssen, D. W. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.24117 · Cited by 34
“and Morgan et al.(24,25) resulted in overpredictions of the experimental measurements, whereas models based on Ouyang et al.”
BackgroundMethodThe Effect of Bone Quality on the Stability of Ankle Arthrodesis. A Finite Element Study
Alonso-Vázquez, A., Lauge-Pedersen, H., Lidgren, L., & Taylor, M. (2004) · Foot & Ankle International · doi:10.1177/107110070402501115 · Cited by 37
Hip resurfacing increases bone strains associated with short‐term femoral neck fracture
Long, J. P., Santner, T. J., & Bartel, D. L. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20884 · Cited by 35
Bioprinting of gelatin-based materials for orthopedic application
Waidi, Y. O., Kariim, I., & Datta, S. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1357460 · Cited by 35
Bone Material Properties and Skeletal Fragility
Fyhrie, D. P., & Christiansen, B. (2015) · Calcified Tissue International · doi:10.1007/s00223-015-9997-1 · Cited by 41
Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain
Terrier, A., Fernandes, C. S., Guillemin, M. R., & Crevoisier, X. M. (2017) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2017.07.009 · Cited by 33
“A value of 1% was considered as critical for bone micro-damage (Carter et al. 1981; Morgan and Keaveny 2001).”
BackgroundMethodGebert, A., Peters, J., Bishop, N. E., Westphal, F. M., & Morlock, M. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.04.007 · Cited by 33
Metzner, F., Neupetsch, C., Fischer, J.-P., Drossel, W. G., Heyde, C.-E., & Schleifenbaum, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-92685-z · Cited by 33
Gupta, A. K., Bayraktar, H. H., Fox, J. C., Keaveny, T. M., & Papadopoulos, P. (2006) · Computational Mechanics · doi:10.1007/s00466-006-0082-5 · Cited by 32
“The primary elastic modulus (E1, in MPa) is assigned to each element using apparent density-modulus relationship determined from on-axis mechanical tests of trabecular bone cores from the greater trochanter and femoral neck [7, 26] as”
BackgroundMethodSelf-citationThe Bone Organ System: Form and Function
Morgan, E. F., Barnes, G. B., & Einhorn, T. A. (2008) · Elsevier eBooks · doi:10.1016/b978-012370544-0.50003-3 · Cited by 81
Self-citationYang, S., Leslie, W. D., Luo, Y., Goertzen, A. L., Ahmed, S., Ward, L. M., Delubac, I., & Lix, L. M. (2017) · Osteoporosis International · doi:10.1007/s00198-017-4232-8 · Cited by 32
Robertson, S. F., & Bose, S. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103945 · Cited by 34
“3) showed both TCP and TCP + PD2 samples exhibited compressive strengths of ~3.8 MPa, and an average Young’s Modulus of ~327 MPa was calculated from stress-strain curves (not shown).”
BackgroundInfluentialAtlas of Human Skeleton Hardness Obtained Using the Micro‐indentation Technique
Li, S., Wang, J., Yin, B., Hu, Z., Zhang, X., Wu, W., Liu, G., Liu, Y., Fu, L., & Zhang, Y. (2021) · Orthopaedic Surgery · doi:10.1111/os.12841 · Cited by 31
Biomechanics of Musculoskeletal System and Its Biomimetic Implications: A Review
Ren, L., Qian, Z., & Ren, L. (2014) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(14)60033-0 · Cited by 39
Lee, D. C., Varela, A., Kostenuik, P. J., Ominsky, M. S., & Keaveny, T. M. (2016) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2830 · Cited by 31
Self-citationZeinali, A., Hashemi, B., & Akhlaghpoor, S. (2009) · Physica Medica · doi:10.1016/j.ejmp.2009.08.002 · Cited by 31
“2 y [19] and y is calculated from Eq.”
BackgroundInfluentialA method for patient-specific evaluation of vertebral cancellous bone strength: In vitro validation
Diamant, I., Shahar, R., Masharawi, Y., & Gefen, A. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.10.005 · Cited by 31
Tomar, V. (2008) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2008.12.013 · Cited by 35
“Later studies have focused on yielding of trabecular bone tissue and have not provided a direct evidence of tensile vs. compressive fracture strength variation, Morgana and Keaveny [ 58 ] and Keaveny et al. [55].”
BackgroundHaider, I. T., GOLDAK, J. A., & Frei, H. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.02.008 · Cited by 30
Robinson, D. L., Safai, L., Harandi, V. J., Graf, M., Lizama, L. E. C., Lee, P. V. S., Galea, M. P., Khan, F., Tse, K. M., & Ackland, D. C. (2020) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2020.01.017 · Cited by 30
Bone: A Composite Natural Material
Fatima, M., Canhão, H. M., & Eurico, J. (2011) · InTech eBooks · doi:10.5772/17523 · Cited by 37
“The shape of the samples may be cubic (Diamant et al., 2007; Sun et al., 2008) or cylinder (Li & Aspden, 1997; Matsuura et al., 2008; Morgan & Keaveny, 2001).”
BackgroundMethodInfluentialDistinct Tissue Mineral Density in Plate- and Rod-like Trabeculae of Human Trabecular Bone
Wang, J., Kazakia, G. J., Zhou, B., Shi, X., & Guo, X. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2498 · Cited by 30
“Trabecular bone cores were drilled along the principle loading direction following a previously reported protocol.((16)) To ensure that the longitudinal axis of the bone core was aligned along the primary trabecular orientation, X-ray radiographs were taken on two orthogonal planes parallel to the longitudinal axis.”
MethodStender, M. E., Regueiro, R. A., & Ferguson, V. L. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1233326 · Cited by 30
O’Rourke, D., Al‐Dirini, R. M. A., & Taylor, M. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23709 · Cited by 30
Jain, S., Gujjala, R., Azeem, P. A., Ojha, S., & Samudrala, R. K. (2021) · Ceramics International · doi:10.1016/j.ceramint.2021.11.206 · Cited by 30
Biomechanics of Bone and Age-Related Fractures
Morgan, E. F., & Bouxsein, M. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373884-4.00024-0 · Cited by 40
Self-citationAxial-shear interaction effects on microdamage in bovine tibial trabecular bone
Wang, X., Guyette, J. P., Liu, X., Roeder, R. K., & Niebur, G. L. (2005) · European Journal of Morphology · doi:10.1080/09243860500095570 · Cited by 34
“However, the architecture and mechanical properties of bovine tibial trabecular bone is similar to that in the healthy human proximal femur (Keaveny et al. 1994a; Morgan & Keaveny 2001 ).”
BackgroundMethodInfluentialShear strength and toughness of trabecular bone are more sensitive to density than damage
Garrison, J. G., Gargac, J. A., & Niebur, G. L. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.09.002 · Cited by 32
“The yield and ultimate shear strains of trabecular bone within a single anatomic site are not statistically dependent on modulus (Turner, 1989; Keaveny and Hayes, 1993; Ford and Keaveny, 1996; Morgan and Keaveny, 2001).”
BackgroundBoccaccio, A., Vena, P., Gastaldi, D., Franzoso, G., Pietrabissa, R., & Pappalettere, C. (2008) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim296 · Cited by 34
The bone organ system: form and function
Morgan, E. F., & Gerstenfeld, L. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813073-5.00002-2 · Cited by 38
Self-citationZumofen, L., Kopanska, K. S., Bono, E., Kirchheim, A., de Haller, E. B., & Graf‐Hausner, U. (2022) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2021.830126 · Cited by 29
Effect of torsional loading on compressive fatigue behaviour of trabecular bone
Januddi, F., Rabiatul, A. A. R., Harun, M. N., Kadir, M. R. A., Kamarul, T., & Syahrom, A. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.09.006 · Cited by 30
“However, there are a few works done that demonstrate agreement between the architecture as well as mechanical properties of bovine trabecular bone and that of a healthy human (Keaveny et al., 1994; Morgan and Keaveny, 2001).”
Determination of suitable sample sizes for multi-patient based finite element studies
Radcliffe, I. A. J., Prescott, P., Man, H. S., & Taylor, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.007 · Cited by 32
Terrier, A., Obrist, R., Becce, F., & Farron, A. (2017) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2017.02.023 · Cited by 28
Aiyangar, A. K., Vivanco, J. F., Au, A. G., Anderson, P. A., Smith, E. L., & Ploeg, H. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027663 · Cited by 29
“This particular point was also confirmed in a subsequent study by Morgan and Keaveny [15].”
ResultPreparation of On-Axis Cylindrical Trabecular Bone Specimens Using Micro-CT Imaging
Wang, X., Liu, A. X., & Niebur, G. L. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1645866 · Cited by 29
Trabecular Eccentricity and Bone Adaptation
Fox, J. C., & Keaveny, T. M. (2001) · Journal of Theoretical Biology · doi:10.1006/jtbi.2001.2371 · Cited by 28
Self-citationConrad, T. L., & Roeder, R. K. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103730 · Cited by 27
Zheng, L., Chen, X., Zheng, Y., He, X., Wu, J., & Lin, Z. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04878-2 · Cited by 27
“(4) [21], the apparent density (ρapp), E and σ of trabecular bone were calculated.”
BackgroundSingh, A. P., Rana, M., Pal, B., Datta, P., Majumder, S., & Chowdhury, A. R. (2023) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2023.103959 · Cited by 27
An Overview of Selected Material Properties in Finite Element Modeling of the Human Femur
Bazyar, P., Baumgart, A., Altenbach, H., & Usbeck, A. K. (2023) · Biomechanics · doi:10.3390/biomechanics3010012 · Cited by 31
“The yield stress is the average of the values for the greater trochanter and femoral neck described in [24], which is roughly 3 MPa and 12 MPa, respectively.”
BackgroundNumerical Modelling of Femur Fracture and Experimental Validation Using Bone Simulant
Marco, M., Giner, E., Larrainzar‐Garijo, R., Caeiro, J. R., & Miguélez, M. H. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1877-6 · Cited by 27
“The value obtained in the experiments for the cortical material of the composite bone is higher than the critical strain given in [25], where a critical strain of 0.”
BackgroundMethodMajumder, S., Roychowdhury, A., & Pal, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.03.044 · Cited by 27
“7% (Morgan and Keaveny, 2001) and compressive ultimate strain as 1.”
BackgroundSabahi, N., Farajzadeh, E., Roohani, I., Wang, C. H., & Li, X. (2024) · Applied Materials Today · doi:10.1016/j.apmt.2024.102262 · Cited by 28
Kelly, N., Cawley, D. T., Shannon, F. J., & McGarry, P. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.05.007 · Cited by 26
“16 MPa) for the PU under uniaxial compression are in the lower range of reported values for human proximal tibial trabecular bone [31-33] and may be representative of osteoporotic trabecular bone.”
BackgroundThe bone strain index predicts fragility fractures. The OFELY study
Sornay‐Rendu, E., Duboeuf, F., Ulivieri, F. M., Rinaudo, L., & Chapurlat, R. D. (2022) · Bone · doi:10.1016/j.bone.2022.116348 · Cited by 26
Rieger, R., Aurégan, J.-C., & Hoc, T. (2017) · Morphologie · doi:10.1016/j.morpho.2017.07.175 · Cited by 28
Al‐Dirini, R. M. A., Martelli, S., O’Rourke, D., Huff, D. N., Ju, Z., Clement, J. G., Besier, T. F., & Taylor, M. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.013 · Cited by 25
“, 1986b), while peri-prosthetic bone damage is likely due to excessive strains on the host bone (Morgan and Keaveny, 2001).”
BackgroundCosma, C., Drstvenšek, I., Berce, P., Prunean, S., Legutko, S., Popa, C. O., & Bâlc, N. (2020) · Materials · doi:10.3390/ma13184123 · Cited by 25
Ong, K. L., Lehman, J. S., Notz, W. I., Santner, T. J., & Bartel, D. L. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2165701 · Cited by 25
Giordano, C., Sanginario, V., Ambrosio, L., Silvio, L. D., & Santin, M. (2005) · Journal of Biomaterials Applications · doi:10.1177/0885328206051811 · Cited by 25
“As presented in Table 1, the composite shows compressive properties in the range of vertebral trabecular bone [10].”
BackgroundAutomation of a DXA-based finite element tool for clinical assessment of hip fracture risk
Luo, Y., Ahmed, S. I., & Leslie, W. D. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.11.020 · Cited by 27
Talukdar, R. G., Mukhopadhyay, K. K., Dhara, S., & Gupta, S. (2021) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211008343 · Cited by 25
“06% for vertebrae (Morgan and Keaveny).(53) The stress distribution in the vertebrae for the intact models during different physiologic movements, were similar to those reported in earlier studies.”
ResultComposite materials for hip joint prostheses
Santis, R. D., Gloria, A., & Ambrosio, L. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100752-5.00012-3 · Cited by 24
Damage in total knee replacements from mechanical overload
Zimmerman, W. F., Miller, M. A., Cleary, R. J., Izant, T. H., & Mann, K. A. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.05.014 · Cited by 24
“Bone strain was compared to the known range of yield strain of tibial trabecular bone (−7300±600με) (Morgan and Keaveny, 2001).”
BackgroundMethodHelgason, B., Viceconti, M., Rúnarsson, T. P., & Brynjólfsson, S. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.03.007 · Cited by 30
Structural strength of cancellous specimens from bovine femur under cyclic compression
Endo, K., Yamada, S., Todoh, M., Takahata, M., Iwasaki, N., & TADANO, S. (2016) · PeerJ · doi:10.7717/peerj.1562 · Cited by 31
de Brosses, E. S. , Jolivet, E., Travert, C., Mitton, D., & Skalli, W. (2012) · Spine · doi:10.1097/brs.0b013e3182293628 · Cited by 24
Zhang, T., Chen, C., Dong, J., Wu, Y., Hu, Q., Lei, T., Lei, P., & Zhou, K. (2021) · Materials Characterization · doi:10.1016/j.matchar.2021.111554 · Cited by 23
Towards a patient-specific estimation of intra-operative femoral fracture risk
Esposito, L., Bifulco, P., Gargiulo, P., Gíslason, M. K., Cesarelli, M., Iuppariello, L., Jónsson, H., Cutolo, A., & Fraldi, M. (2018) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2018.1508570 · Cited by 23
“The yield stress defined as that corresponding to the mean value of yield strain was set to 0.7 (Morgan and Keaveny 2001), while the tangent modulus was set to five hundredths of the corresponding elastic modulus (Reilly and Burstein 1975), depending on local density.”
BackgroundInfluentialZhang, N., Magland, J. F., Rajapakse, C. S., Bhagat, Y. A., & Wehrli, F. W. (2013) · Medical Physics · doi:10.1118/1.4802085 · Cited by 23
Zheng, L., Wong, D. W., Chen, X., Chen, Y., & Li, P. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1964488 · Cited by 22
Ovesy, M., Silva-Henao, J. D., Fletcher, J. W. A., Gueorguiev, B. G., Zysset, P. K., & Varga, P. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.105002 · Cited by 22
Putra, N. E., Moosabeiki, V., Leeflang, M. A., Zhou, J., & ZADPOOR, A. A. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.02.024 · Cited by 22
“It is, therefore, expected to be able to meet the biomechanical requirements for trabecular bone substitution subjected to compressive loading, e.g. , in human vertebrae or greater trochanter part of the femur [ 25 , 26 ].”
InfluentialVirtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures
Petfield, J. L., Hayeck, G. T., Kopperdahl, D. L., Nesti, L. J., Keaveny, T. M., & Hsu, J. R. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23335 · Cited by 22
Self-citationMoideen, I. S. M., Lim, C. T., Yeow, C., & Chong, D. Y. R. (2020) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3310 · Cited by 22
“65% (6500 με) (maximum principal strain).(25,40) Potentially, the new PD Design (contralateral talus bone left) induced experimental and predicted principal strains that were essentially lower than the STAR Ankle talar component.”
BackgroundBoulanaache, Y., Becce, F., Farron, A., Pioletti, D. P., & Terrier, A. (2020) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.09.009 · Cited by 22
Mechanical and morphological characterization of PMMA/bone composites in human femoral heads
Sas, A., Helgason, B., Ferguson, S. J., & van Lenthe, H. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104247 · Cited by 22
Risk Assessment of Hip Fracture Based on Machine Learning
Galassi, A., Martín‐Guerrero, J. D., Villamor, E., Monserrat, C., & Rupérez, M. J. (2020) · Applied Bionics and Biomechanics · doi:10.1155/2020/8880786 · Cited by 22
Fused deposition modeling of poly(ether ether ketone) scaffolds
Song, X., Shi, D., Song, P., Han, X., Wei, Q., & Huang, C. (2021) · High Temperature Materials and Processes · doi:10.1515/htmp-2021-0009 · Cited by 24
“Morgan and Keaveny [44] concluded the mechanical properties of trabecular bone: the tensile strengths for the vertebra, proximal tibia, and greater trochanter were 1.72, 4.5, and 2.44 MPa, respectively; the compressive yield strengths for vertebra, proximal tibia, and greater trochanter were 2.02, 5.83, and 3.21 MPa,…”
BackgroundInfluentialPal, B., Gupta, S., & New, A. (2009) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840903067064 · Cited by 22
“It has been reported that yield strain of trabecular bone is uniform within an anatomic site (it does not depend on the apparent density) and is believed to be isotropic (Chang et al. 1999; Morgan and Keaveny 2001).”
BackgroundInfluentialLee, C., Lee, J., Youn, B., Kim, H., Shin, J. K., Goh, T. S., & Lee, J. S. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.08.028 · Cited by 24
Commonality in the microarchitecture of trabecular bone: A preliminary study
Zhao, F., Kirby, M. L., Roy, A., Hu, Y., Guo, X., & Wang, X. (2018) · Bone · doi:10.1016/j.bone.2018.03.003 · Cited by 22
Trabecular Architecture and Mechanical Heterogeneity Effects on Vertebral Body Strength
Auger, J., Frings, N. R., Wu, Y., Marty, A. G., & Morgan, E. F. (2020) · Current Osteoporosis Reports · doi:10.1007/s11914-020-00640-0 · Cited by 25
Self-citationGlenday, J. D., Wright, T. M., Lipman, J. D., Sculco, P. K., Mayman, D. J., Vigdorchik, J. M., & González, F. J. Q. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25129 · Cited by 23
“bone failure, using a principal strain failure criterion for bone tissue.(31) Bone was considered at risk of failure if the maximum tensile strain exceeded 6500 με or the minimum compressive strain exceeded ‐7300 με.”
MethodBoosting bone regeneration using augmented melt-extruded additive-manufactured scaffolds
Cámara-Torres, M., Fucile, P., Sinha, R., Mota, C., & Moroni, L. (2023) · International Materials Reviews · doi:10.1080/09506608.2022.2153219 · Cited by 23
Dong, R., Kang, M., Qu, Y., Hou, T., Zhao, J., & Cheng, X. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202403613 · Cited by 25
Metadata
- Authors
- Morgan, E. F., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Morgan, Elise F
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 34
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2073813406
- Cited by
- 705
- References
- 37
- Citations by year
- 2026: 30 · 2025: 30 · 2024: 42 · 2023: 27 · 2022: 39 · 2021: 44 · 2020: 50 · 2019: 31 · 2018: 29 · 2017: 40 · 2016: 23 · 2015: 23 · 2014: 36 · 2013: 42 · 2012: 24
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, bone mechanical properties, vertebral bone, femoral neck, proximal tibia, bone mineral density, elastic modulus, yield stress, structure-function relationship
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Bone and Bones, Female, Femur, Femur Neck, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Models, Anatomic, Spine, Tensile Strength, Tibia, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.