Dependence of yield strain of human trabecular bone on anatomic site
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Understanding the dependence of human trabecular bone strength behavior on anatomic site provides insight into structure-function relationships and is essential to the increased success of site-specific finite element models of whole bones. To investigate the hypothesis that the yield strains of human trabecular bone depend on anatomic site, the uniaxial tensile and compressive yield properties were compared for cylindrical specimens from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27) taken from 61 donors (67+/-15years). Test protocols were used that minimized end artifacts and loaded specimens along the main trabecular orientation. Yield strains by site (mean+/-S.D.) ranged from 0.70+/-0.05% for the trochanter to 0.85+/-0.10% for the femoral neck in compression, from 0.61+/-0.05% for the trochanter to 0.70+/-0.05% for the vertebra in tension, and were always higher in compression than tension (p<0.001). The compressive yield strain was higher for the femoral neck than for all other sites (p<0.001), as was the tensile yield strain for the vertebra (p<0.007). Analysis of covariance, with apparent density as the covariate, indicated that inter-site differences existed in yield stress even after adjusting statistically for density (p<0.035). Coefficients of variation in yield strain within each site ranged from only 5-12%, consistent with the strong linear correlations (r(2)=0.94-0.98) found between yield stress and modulus. These results establish that the yield strains of human trabecular bone can differ across sites, but that yield strain may be considered uniform within a given site despite substantial variation in elastic modulus and yield stress.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The volume fraction of trabecular bone varies from 60% in primary compressive group of femoral neck to less than 10% in the elderly spine (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
9 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718 · cited 1×
“Through advancements in imaging techniques and computational methods, it is now possible to create detailed anatomic site-specific finite element models of trabecular bone specimens (Kabel et al., 1999; Ulrich et al., 1999; Zysset et al., 1998) and whole bones (Keyak and Rossi, 2000; Lotz et al.”
MethodPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“, 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 6×
“Uniaxial compressive and tensile mechanical tests were conducted at room temperature using a servohydraulic load frame (858 Mini-Bionix, MTS, Eden Prairie, MN) following protocols designed to minimize end artifacts (Keaveny et al., 1994a; Kopperdahl and Keaveny, 1998).”
BackgroundMethodResultSelf-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 1×
“, 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al., 1997; Mosekilde et al., 1987) render the strength behavior of human trabecular bone of primary medical importance.”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432 · cited 1×
“The central role of trabecular bone in the etiology of whole bone fractures (Lotz and Hayes 1990; McBroom et al., 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al.”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431 · cited 1×
“tension) in yield strains across all anatomic sites supports previous suggestions of a similarity in the yield strains between trabecular and cortical tissue (Keaveny, 1997; Niebur et al., 2000).”
ResultSelf-citation
Research works printed but not linked: 1
- Niebur, G.L., Keaveny, T.M., 2001. Trabecular bone exhibits multiple failure surfaces in biaxial loading. Transactions on Orthopaedic Research Society 26.
Cited by
Items 701–732 of 732
Gibson, F. G. (2025) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
三又, 秀. (2022) · Institutional Repositories DataBase (IRDB)
Kusins, J. R. (2021) · Scholarship@Western (Western University)
Wills, C. R., Qasim, M., Winzenrieth, R., Gregorio, S. D., del Río, L., Humbert, L., & Noailly, J. (2025) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2025.101663
Taritsa, I. C., Wang, Y., Mahle, R., Alvarez, A. H., Schuster, K. A., Cordero, J. J., Nayak, S., Li, C., Kaplan, D. L., & Lin, S. J. (2026) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2026.107386
Engineering Multiscale Porosity in Starch–Hydroxyapatite Aerogels and Aerogel-like Xerogels
Bouras, H., Buwalda, S. J., Tillier, Y., Roscelli, A., Nédélec, J., Corinus, A., Luton, F., Marchat, D., & Budtova, T. (2026) · European Polymer Journal · doi:10.1016/j.eurpolymj.2026.114646
Sharabi, M., Wilke, H.-J., & Haj-Ali, R. M. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-26568-6.00029-1
Influence de l’hétérogénéité des propriétés mécaniques sur la résistance de l’os trabéculaire humain
Dépalle, B. (2011) · theses.fr (ABES) · doi:10.70675/bf4d472cz0dd4z4d20za7f2zd8806f663dd6 · Cited by 5
“Juste avant l’essai, les extrémités des échantillons ont été incluses dans des capuchons d’aluminium avec de la résine d’enrobage à froid à prise rapide (Technovit 3040, Heraeus Kulzer GmbH, Wehrheim, Germany) pour limiter les effets de bords [122, 204, 285, 284].”
Stable Fixation in Cementless Total Knee Arthroplasty Even for Low Local Bone Mineral Density
González, F. J. Q., Teeter, M. G., Sculco, P. K., Zepeda, K. E., Yared, T. M., Burgio, C., Kolli, H., Lipman, J. D., Kahlenberg, C. A., Debbi, E. M., et al. (2026) · The Journal of Arthroplasty · doi:10.1016/j.arth.2026.03.014
Modélisation par éléments finis des effets des médicaments sur la résistance de l’os
Boughattas, M. H. (2017) · theses.fr (ABES) · doi:10.70675/09e4577cz66c7z4387zad11z70a4fe10661c
Out-of-equilibrium bioactive ceramics coatings by Electrostatic Spray Deposition
Müller, V. (2021) · theses.fr (ABES) · doi:10.70675/23df7babzb6fcz4f87z9597z818ebdc6cf69
Modèles topologiques et mécaniques pour l’étude du comportement anisotrope de l’os trabéculaire
Rogalski, N. (2023) · theses.fr (ABES) · doi:10.70675/aac283e9z823fz44d1za581zd060f5ec8626 · Cited by 1
Création et caractérisation d'organoïdes osseux
Rouquier, L. (2024) · theses.fr (ABES) · doi:10.70675/e97d2544z2680z454cz890cz5c3b53329b34
Decaup, P.-H. (2025) · theses.fr (ABES) · doi:10.70675/dfb3b403zf2a9z4691z9550z3b2a7fa34564
Xu, Y., Yi, Z., Zhang, Y. J., Diao, N., Yin, H., & Dai, Y. (2026) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-026-06982-2
“For cancellous bone, the stress values observed in this study (4.37 MPa under 2 mm elevation) are below the reported compressive yield strength of proximal tibial cancellous bone (approximately 5.8 ± 3.4 MPa)[49], but approach the upper range of this value under the 2 mm elevation condition.”
InfluentialMüller, L., Kunnoth, S., Souhail, H., Ska, M., Uniyal, P., D’Andrea, L., Vena, P., van Lenthe, H., Dall’Ara, E., & Ruffoni, D. (2026) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2026.107481
Das, S., Seesala, V. S., & Dhara, S. (2026) · International Journal of Applied Glass Science · doi:10.1111/ijag.70042
3D-Printed Scaffolds for Local Chemotherapeutic Delivery in Resected Spine MetastasesPreprint
Pitaru, A. A., Siddique, A., Garakani, M. M., Boakye, B. N., Weber, M. H., Ajji, A., Wertheimer, M. R., Villemure, I., Haglund, L., & Rosenzweig, D. H. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.09.731191
“One previous study determined a Young’s modulus of vertebral trabecular bone of 344 MPa (±148) [26].”
InfluentialJiang, C., Chen, J. M., Ouyang, H., Hu, D., Hao, Y., Dong, S., Tang, G., Chen, Z. Y., Wang, Y., Wu, M., et al. (2026) · European Spine Journal · doi:10.1007/s00586-026-10048-6
Mahapatra, B., & Pal, B. (2026) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.70191
“This value was adopted from the literature [33–35] where compressive and tensile yield strains of human cancellous bone have been consistently reported in the range of 0.6%–0.8%.”
InfluentialLima, L. C. G., Caetano, D., Pinto, L. A., Pessan, L. A., & Backes, E. H. (2026) · Journal of Polymer Research · doi:10.1007/s10965-026-05004-3
“The structure of human trabecular bone is highly porous and, therefore, exhibits apparent modulus values ranging from 10 to 3,000 MPa, and these values are highly influenced by the apparent density of the bone (the mass of bone tissue divided by the total volume of the sample) [44].”
Allahyari, M., Fereydoonpour, M., Rezaei, A., & Karami, G. (2026) · Bioengineering · doi:10.3390/bioengineering13070747
Viscoelastic modeling of bone-like materials
Liu, L. W., Wang, J.-Y., Shih, Y.-J., Chang, Y.-T., Chao, C.-M., & Chen, K.-C. (2026) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2026.106265
Biomechanical modeling of bone: Topology optimization and microstructural analysis
Goda, I., & Ganghoffer, J. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-26739-0.00018-1
Uniyal, P., & van Lenthe, H. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-26739-0.00008-9
Biomechanical evaluation of percutaneous tripod screw reconstruction for periacetabular metastases
Du, Z., Shang, Z., Qi, F., Liang, H., Zhao, Z., Liu, X., Huang, S., Xu, J., Chen, L., 李清花, et al. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.113162
Slive, L., Shin, Y. Y., McGregor, M., McLachlin, S., & Kusins, J. R. (2026) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2026.113621
Ren, Y., Scott, C. E. H., Clement, N. D., Xie, S., & Pankaj, P. (2026) · Bone and Joint Research · doi:10.1302/2046-3758.1510.bjr-2026-0180.r1
Characterization Of The Response Of Synthetic Bone Substitute To Compressive Load
Hamedon, Z. B., & Sani, M. S. M. (2009) · UMP Institutional Repository (Universiti Malaysia Pahang)
Metadata
- Authors
- Morgan, E. F., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Morgan, Elise F
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 34
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2073813406
- Cited by
- 705
- References
- 37
- Citations by year
- 2026: 30 · 2025: 30 · 2024: 42 · 2023: 27 · 2022: 39 · 2021: 44 · 2020: 50 · 2019: 31 · 2018: 29 · 2017: 40 · 2016: 23 · 2015: 23 · 2014: 36 · 2013: 42 · 2012: 24
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, bone mechanical properties, vertebral bone, femoral neck, proximal tibia, bone mineral density, elastic modulus, yield stress, structure-function relationship
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Bone and Bones, Female, Femur, Femur Neck, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Models, Anatomic, Spine, Tensile Strength, Tibia, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.