Dependence of yield strain of human trabecular bone on anatomic site
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Understanding the dependence of human trabecular bone strength behavior on anatomic site provides insight into structure-function relationships and is essential to the increased success of site-specific finite element models of whole bones. To investigate the hypothesis that the yield strains of human trabecular bone depend on anatomic site, the uniaxial tensile and compressive yield properties were compared for cylindrical specimens from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27) taken from 61 donors (67+/-15years). Test protocols were used that minimized end artifacts and loaded specimens along the main trabecular orientation. Yield strains by site (mean+/-S.D.) ranged from 0.70+/-0.05% for the trochanter to 0.85+/-0.10% for the femoral neck in compression, from 0.61+/-0.05% for the trochanter to 0.70+/-0.05% for the vertebra in tension, and were always higher in compression than tension (p<0.001). The compressive yield strain was higher for the femoral neck than for all other sites (p<0.001), as was the tensile yield strain for the vertebra (p<0.007). Analysis of covariance, with apparent density as the covariate, indicated that inter-site differences existed in yield stress even after adjusting statistically for density (p<0.035). Coefficients of variation in yield strain within each site ranged from only 5-12%, consistent with the strong linear correlations (r(2)=0.94-0.98) found between yield stress and modulus. These results establish that the yield strains of human trabecular bone can differ across sites, but that yield strain may be considered uniform within a given site despite substantial variation in elastic modulus and yield stress.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The volume fraction of trabecular bone varies from 60% in primary compressive group of femoral neck to less than 10% in the elderly spine (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
9 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718 · cited 1×
“Through advancements in imaging techniques and computational methods, it is now possible to create detailed anatomic site-specific finite element models of trabecular bone specimens (Kabel et al., 1999; Ulrich et al., 1999; Zysset et al., 1998) and whole bones (Keyak and Rossi, 2000; Lotz et al.”
MethodPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“, 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 6×
“Uniaxial compressive and tensile mechanical tests were conducted at room temperature using a servohydraulic load frame (858 Mini-Bionix, MTS, Eden Prairie, MN) following protocols designed to minimize end artifacts (Keaveny et al., 1994a; Kopperdahl and Keaveny, 1998).”
BackgroundMethodResultSelf-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 1×
“, 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al., 1997; Mosekilde et al., 1987) render the strength behavior of human trabecular bone of primary medical importance.”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432 · cited 1×
“The central role of trabecular bone in the etiology of whole bone fractures (Lotz and Hayes 1990; McBroom et al., 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al.”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431 · cited 1×
“tension) in yield strains across all anatomic sites supports previous suggestions of a similarity in the yield strains between trabecular and cortical tissue (Keaveny, 1997; Niebur et al., 2000).”
ResultSelf-citation
Research works printed but not linked: 1
- Niebur, G.L., Keaveny, T.M., 2001. Trabecular bone exhibits multiple failure surfaces in biaxial loading. Transactions on Orthopaedic Research Society 26.
Cited by
Items 401–500 of 732
Olsen, M., Davis, E. T., Whyne, C. M., Zdero, R., & Schemitsch, E. H. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4001159 · Cited by 11
de Brosses, E. S. , Briot, K., Kolta, S., Skalli, W., Roux, C., & Mitton, D. (2010) · IRBM · doi:10.1016/j.irbm.2010.02.014 · Cited by 11
Cabal, A., Williams, D. S., Jayakar, R. Y., Zhang, J., Sardesai, S., & Duong, L. T. (2017) · Bone Reports · doi:10.1016/j.bonr.2017.01.001 · Cited by 11
“Three preconditioning cycles to 0.1% strain were followed by a final ramp at 0.5% strain per second that loaded the specimen all the way to failure (Morgan and Keaveny, 2001).”
BackgroundMethodInfluentialNew Guinea bone daggers were engineered to preserve social prestige
Dominy, N. J., Mills, S. T., Yakacki, C. M., Roscoe, P. B., & Carpenter, R. D. (2018) · Royal Society Open Science · doi:10.1098/rsos.172067 · Cited by 11
“4 GPa [53,58]) and overlap (σult = 103–133 MPa [52–57]) published values for dry compact bone from human femora, which simplified the construction of our FE models.”
BackgroundInfluentialCarranza, V. A., Reeves, J. M., Getgood, A. M. J., & Burkhart, T. A. (2019) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2018.1563599 · Cited by 11
“An ultimate stress of 9MPa (Hernandez 2016; Morgan and Keaveny 2001) was used to visually compare the location and severity of bone failure using von Mises stresses within the nine sub-regions of the three groups (Hernandez 2016); it was assumed that the crack will initiate in the trabecular bone…”
MethodHarnroongroj, T., Volpert, L., Ellis, S. J., Sofka, C. M., Deland, J. T., & Demetracopoulos, C. A. (2019) · Foot & Ankle International · doi:10.1177/1071100719868496 · Cited by 11
“Therefore, the calculations of strength and stiffness were not always straightforwardly correlated with the power of 2 and 3.(18,22,23,26) Thus, in this study, we decided not to convert our HU value into strength and stiffness as there was no definite conclusion of these correlations and might lead to error.”
Aguirre, T. G., Ingrole, A., Fuller, L. H., Seek, T. W., Fiorillo, A. R., Sertich, J. J. W., & Donahue, S. W. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237042 · Cited by 12
Bone Remodeling Around Solid and Porous Interbody Cages in the Lumbar Spine
Talukdar, R. G., Saviour, C. M., Tiwarekar, K., Dhara, S., & Gupta, S. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4054457 · Cited by 11
Mechanical properties of microporous foams of biodegradable plastic
Tanaka, T., Aoki, T., Kouya, T., Taniguchi, M., Ogawa, W., Tanabe, Y., & Lloyd, D. R. (2010) · Desalination and Water Treatment · doi:10.5004/dwt.2010.1696 · Cited by 11
A Method for the Evaluation of Femoral Head Trabecular Bone Compressive Properties
Aleixo, I., Vale, A. C., Lúcio, M., Amaral, P. M., Rosa, L. G., Caetano‐Lopes, J., Rodrigues, A. M., Canhão, H. M., Fonseca, J. E., & Vaz, M. F. (2012) · Materials science forum · doi:10.4028/www.scientific.net/msf.730-732.3 · Cited by 11
Sanyal, A., & Keaveny, T. M. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025679 · Cited by 13
Self-citationMicrostructure of the human metastatic vertebral body
Cavazzoni, G., Dall’Ara, E., & Palanca, M. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1508504 · Cited by 10
Zhang, M., Gong, H., & Zhang, M. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25334 · Cited by 10
“The elastic and plastic properties of each material were assigned based on the proposed empirical relationships (Supporting Information Appendix 1).(26,27) The material property of PMMA was set as isotropic linear elastic (E MPa = 2500 , v = 0.”
MethodSadoughi, S., Bevill, G. R., Morgan, E. F., Palepu, V., Keaveny, T. M., & Wear, K. A. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2022.2069465 · Cited by 12
Self-citationGonzález, F. J. Q., Sculco, P. K., Kahlenberg, C. A., Mayman, D. J., Lipman, J. D., Wright, T. M., & Vigdorchik, J. M. (2022) · The Journal of Arthroplasty · doi:10.1016/j.arth.2022.10.032 · Cited by 10
Biomechanical Aspects in Bone Tumor Engineering
Menshikh, K. A., Banićević, I., Obradović, B., & Rimondini, L. (2024) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2023.0106 · Cited by 13
“37,39 This can be partly explained by the difference between the two main phases of bone tissue—stromal and mineral.”
BackgroundLiu, Y., Zheng, L., Li, S., Zhang, Z., Lin, Z., & Ma, W. (2024) · Scientific Reports · doi:10.1038/s41598-024-61122-2 · Cited by 10
Ouranj, Z. D., Hosseini, S., Alipour, A., Homaeigohar, S., Azari, S., Ghazizadeh, L., Shokrgozar, M. A., Thomas, S., Irian, S., & Shahsavarani, H. (2024) · Marine Life Science & Technology · doi:10.1007/s42995-024-00241-1 · Cited by 10
“1F. Derived from this stress–strain curve, the Young’s modulus of the scaffold graph (linear section, R 2 = 0.8657) was calculated to be 9.2 MPa in comparison with that of human trabecular bone ranges between 10 and 3,000 MPa (Morgan et al. 2018).”
InfluentialWang, H., Chen, P., Su, J., Li, Y., Tian, Y., Qi, L., Yan, C., & Shi, Y. (2025) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2024.12.051 · Cited by 10
Irradiation Does Not Modify Mechanical Properties of Cancellous Bone Under Compression
Hernandez, C. J., Ramsey, D. S., Dux, S. J., Chu, E. H., & Rimnac, C. M. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-2148-8 · Cited by 10
“The use of two different techniques is not expected to influence our results because the platens loading with attached extensometer is a reportedly accurate approach [29] and the PMMA embedding has been validated ([7] and Appendix).”
BackgroundMethodSartuqui, J., D’Elía, N. L., Ercoli, D., Sánchez‐deAlcázar, D., Cortajarena, A. L., & Messina, P. V. (2019) · Materials Today Communications · doi:10.1016/j.mtcomm.2019.01.004 · Cited by 10
Jyoti, J., & Ghosh, R. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107574 · Cited by 10
Christen, D., Zwahlen, A., & Müller, R. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.10.010 · Cited by 10
Sensitivity analysis of a cemented hip stem to implant position and cement mantle thickness
Shi, J., Browne, M., Strickland, M. A., Flivik, G., & Taylor, M. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.761693 · Cited by 10
High-Rate Mechanical Properties of Human Heel Pad for Simulation of a Blast Loading Condition
Gabler, L. F., Panzer, M. B., & Salzar, R. S. (2014) · Cited by 10
Polyurethane composite foams with β-tricalcium phosphate for biomedical applications
Szczepańczyk, P., Pielichowska, K., & Chłopek, J. (2015) · Journal of Reinforced Plastics and Composites · doi:10.1177/0731684415602070 · Cited by 10
“5MPa.(55,56) As it can be seen Young modulus and yield strength for PU modified with b-TCP are in the lower range of values.”
BackgroundEffect of sitting posture on pelvic injury risk under vertical loading
Tse, K. M., Robinson, D. L., Franklyn, M., Zhang, J. Y., Spratley, E. M., Salzar, R. S., Fernandez, J., Ackland, D. C., & Lee, P. V. S. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103780 · Cited by 10
Compressive fatigue properties of an acidic calcium phosphate cement—effect of phase composition
Ajaxon, I., Öhman‐Mägi, C., & Persson, C. (2017) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-017-5851-5 · Cited by 9
Sustainably cultured coral scaffold supports human bone marrow mesenchymal stromal cell osteogenesis
Gentili, C., Palamà, M. E. F., Sexton, G., Maybury, S., Shanahan, M., Omowunmi-Kayode, Y. Y., Martin, J., Johnson, M. T., Thompson, K., Clarkin, O. M., et al. (2024) · Regenerative Therapy · doi:10.1016/j.reth.2024.06.002 · Cited by 10
“Compressive strengths measured of trabecular bone vary with anatomical location from 2.02 ± 0.92 MPa for vertebral locations to 17.45 ± 6.15 for femoral neck locations [69].”
BackgroundInfluentialA comparison of density–modulus relationships used in finite element modeling of the shoulder
Knowles, N. K., Langohr, G. D. G., Faieghi, R., Nelson, A. J., & Ferreira, L. M. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.02.005 · Cited by 9
Huang, X., Zheng, L., Zheng, D., Li, S., Fan, Y., Lin, Z., & Huang, S. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1061758 · Cited by 10
“In actual bone samples, tissue modulus and strength appear to be linear within a single anatomic site but to be power-law across multiple sites because of the differentiation of apparent density (r in g/cm(3)) and BV/TV (30, 35).”
BackgroundKreipke, T. C., & Niebur, G. L. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1805-9 · Cited by 9
Initial fixation of a femoral knee component: an in vitro and finite element study
Burgers, T., Mason, J., & Ploeg, H. (2009) · International Journal of Experimental and Computational Biomechanics · doi:10.1504/ijecb.2009.022857 · Cited by 10
“The FE models included a yield strain limit that is independent of density (Morgan and Keaveny, 2001), but this assumption may not hold for pathological bone.”
Kotha, S. P., DePaula, C. A., Mann, A. B., & Güzelsu, N. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.09.020 · Cited by 9
Zhang, C., Chen, S., Muniyandi, V., Qi, Y., Zhou, Y., Fu, G., Li, Z., & Wang, J. (2023) · Inventions · doi:10.3390/inventions8060138 · Cited by 8
A novel design of hip-stem with reduced strain-shielding
Loha, T., Bhattacharya, R., Pal, B., & Amis, A. A. (2024) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119241244537 · Cited by 8
“Experimental studies 41,42 have established a power-law relationship between r and elastic modulus (E), and E = 7281 r 1.52 has been used in previous FE studies of the femur.”
BackgroundMethodInfluentialZhang, H., Wang, R., Song, Y., Wang, Y., & Hu, Q. (2024) · Bioengineering · doi:10.3390/bioengineering11090869 · Cited by 9
Almasi, D., Lau, W. J., Rasaee, S., & Abbasi, K. (2021) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34964 · Cited by 8
Bioactive Polyaryletherketone Composites
Roeder, R. K. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-812524-3.00012-0 · Cited by 9
Fu, G., Zhong, G., Yang, Z., Cheng, S., Ma, L., & Zhang, Y. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.891338 · Cited by 8
“According to the equations between bone density (ρ), Young’s modulus (E), and yield stress (σ) (Morgan and Keaveny, 2001; Duchemin et al., 2008), cortical and cancellous bone’s yield stress was calculated respectively.”
BackgroundStoddart, J. C., Garner, A. J., Tuncer, M., Cobb, J. P., & van Arkel, R. J. (2022) · Bone and Joint Research · doi:10.1302/2046-3758.118.bjr-2021-0533.r1 · Cited by 9
Effects of loading rate, age, and morphology on the material properties of human rib trabecular bone
Albert, D. L., Katzenberger, M. J., Hunter, R. L., Agnew, A. M., & Kemper, A. R. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111670 · Cited by 9
A study of the viscoelastic effect in a bone remodeling model
Baïotto, S., & Zidi, M. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0123-4 · Cited by 8
“Furthermore they are affected by the growth of bone and in diseased areas (Xinghua et al. 2002; Huiskes et al. 2000; Morgan and Keaveny 2001 ).”
BackgroundTAWARA, D., Sakamoto, J., Murakami, H., Kawahara, N., Juhachi, O. D. A., & Tomita, K. (2010) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.5.499 · Cited by 9
McCaffrey, K. A., McCaffrey, M. H., Pelletier, M. H., Lovric, V., Mobbs, R. J., & Walsh, W. R. (2020) · World Neurosurgery · doi:10.1016/j.wneu.2020.10.084 · Cited by 8
The relationship between orthopedic clinical imaging and bone strength prediction
Gong, H., Zhang, M., Jia, S., & Lv, L. (2021) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2021.100060 · Cited by 10
Saviour, C. M., Chowdhury, J. B., & Gupta, S. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4055760 · Cited by 8
Caouette, C., Bureau, M., Vendittoli, P., Lavigne, M. J. F., & Nuño, N. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.01.015 · Cited by 8
O’Rourke, D., Martelli, S., Bottema, M. J., & Taylor, M. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4034831 · Cited by 8
Wang, Z., Xu, B., Yang, J., Yang, B., Xiong, H., Yang, G., & Wang, F. (2020) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2020.09.052 · Cited by 8
Strength reduction in electrical and elastic networks
Ortiz, J. S. E., Rajapakse, C. S., & Gunaratne, G. H. (2002) · Physical review. B, Condensed matter · doi:10.1103/physrevb.66.144203 · Cited by 8
Gide, K. M., & Bagheri, Z. S. (2025) · Heliyon · doi:10.1016/j.heliyon.2025.e44469 · Cited by 7
Bahrami, M., Khonakdar, H., Moghaddam, A., Mahand, S. N., Bambizi, P. E., Kruppke, B., & Khonakdar, H. A. (2024) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2024.10.001 · Cited by 7
Ibrahim, P., Jameekornkul, P., Panesar, A. S., & Attallah, M. M. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.106999 · Cited by 8
Validation of a Finite Element Human Model for Prediction of Rib Fractures
Mordaka, J., Meijer, R., van Rooij, L., & Żmijewska, A. E. (2007) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2007-01-1161 · Cited by 9
Load transfer across a mandible during a mastication cycle: The effects of odontogenic tumour
Dutta, A., Mukherjee, K., Seesala, V. S., Dutta, K., Paul, R. R., Dhara, S., & Gupta, S. (2020) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411920904618 · Cited by 7
“The decrease in Young’s modulus of the cortical bones of the diseased mandibles led to a weakening of the bone structure, eventually making the structure vulnerable to high strains.(34,35) A comparison of maximum tensile strains for model ODT1 and ODT2 indicated that the tensile strain values increased by 96% with a r…”
BackgroundTensile modulus of human orbital wall bones cut in sagittal and coronal planes
Żerdzicki, K., Lemski, P., Kłosowski, P., Skorek, A., Trzebiatowski, M. Z., & Koberda, M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0259363 · Cited by 7
“mandible and jaw, as well as bone parts, various moduli values were found of statistically significant differences [12,17].”
BackgroundNorbertczak, H., Fermor, H. L., Edwards, J. H., Rooney, P., Ingham, E., & Herbert, A. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104965 · Cited by 8
Pradeep, K., Pal, B., Mukherjee, K., & Shetty, G. M. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104178 · Cited by 7
Prediction of proximal femur fracture risk from DXA images based on novel fracture indexes
Zellagui, S., Hivet, A., Mouss, M. E., & Hambli, R. (2021) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2020.1833367 · Cited by 8
Kusins, J. R., Knowles, N. K., Martensson, N., Columbus, M. P., Athwal, G. S., & Ferreira, L. M. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25242 · Cited by 7
“Due to its highly porous structure, the mechanical behavior of trabecular bone is heavily dependent on the structural morphometric parameters and local bone density measurements, which vary by anatomic site.(7) Specifically, relationships between bone volume fraction (BV/TV) and the structural fabric tensor, which can…”
BackgroundResultComputational Study of In-Vivo CT-Based FEM Application in Bone Tissue Engineering
Barua, R., Datta, S., & Banerjee, D. (2022) · Advances in medical education, research, and ethics (AMERE) book series · doi:10.4018/978-1-7998-8871-0.ch014 · Cited by 7
Vale, A. C., Aleixo, I. P., Lúcio, M., Saraiva, A. P., Caetano‐Lopes, J., Rodrigues, A. M., Amaral, P. M., Rosa, L. G., Monteiro, J., Fonseca, J. E., et al. (2013) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-14-295 · Cited by 7
Zhang, R., Gong, H., Fang, J., Gao, Z., & Zhu, D. (2014) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519414500262 · Cited by 7
Song, Y., Wang, S., Chan, M. F., Burman, C., Dhawan, A. P., & Song, Y. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260160 · Cited by 7
Quasi-static Compressive and Tensile Tests on Cancellous Bone in Human Cervical Spine
Liu, J. F., Shim, V. P. W., & Lee, P. V. S. (2012) · Conference proceedings of the Society for Experimental Mechanics · doi:10.1007/978-1-4614-4427-5_16 · Cited by 7
Modeling the Thorax for Impact Scenarios
Yang, K. H., & Presley, B. R. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809831-8.00014-3 · Cited by 7
Effect of Model Parameters on the Biomechanical Behavior of the Finite Element Cervical Spine Model
Doğru, S. C., & Arslan, Y. Z. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/5593037 · Cited by 7
“to the cortical bone, the experimental mechanical testing on the vertebrae specimens showed that the strain level in the cancellous bone was higher and the stress level in the cancellous bone was lower [40, 41].”
BackgroundRetractedDiagnosis of spine pseudoarthrosis based on the biomechanical properties of bone
Hipp, J. A., Mikhael, M. M., Reitman, C. A., Buser, Z., Patel, V. V., Chaput, C. D., Ghiselli, G., DeVine, J. G., Berven, S., Nunley, P. D., et al. (2024) · The Spine Journal · doi:10.1016/j.spinee.2024.08.007 · Cited by 6
Gerber, G., Varga, P., Schwiedrzik, J. J., & Zysset, P. K. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.107157 · Cited by 6
Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis
Chaudhary, M. E., & Walker, P. S. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027467 · Cited by 6
Lozhkomoev, A. S., Буяков, А. С., Казанцев, С. О., Senkina, E. I., Krinitcyn, M., Ivanyuk, V. A., Sharipova, A. F., & Лернер, М. И. (2022) · Materials · doi:10.3390/ma15144900 · Cited by 6
“3% and of t pure Fe obtained in [21], lso corresponding t the parameters of trabecul r bone [43].”
BackgroundJaafar, S., Cristofolini, G., Morenghi, E., Rinaudo, L., Birtolo, M. F., Sala, E., Ferrante, E., Mungari, R., Lavezzi, E., Leonardi, L., et al. (2024) · Endocrine · doi:10.1007/s12020-024-03863-8 · Cited by 6
“The material properties were assigned to each triangle of the generated mesh with a speci fi c stiffness dependent on the BMD value, according to experimental relations and the speci fi c anatomic site [22].”
Cavazzoni, G., Pasini, M., Maitre, C. L. L., Dall’Ara, E., & Palanca, M. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.01.018 · Cited by 6
van den Munckhof, S., Nikooyan, A. A., & ZADPOOR, A. A. (2014) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519415300033 · Cited by 6
Mechanical Properties of Natural Cellular Materials
Tchepel, D., Fernandes, F. A. O., Anjos, O., & de Sousa, R. A. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.04056-x · Cited by 8
Larrainzar‐Garijo, R., Caeiro, J. R., Marco, M., Giner, E., & Miguélez, M. H. (2018) · Revista Española de Cirugía Ortopédica y Traumatología · doi:10.1016/j.recot.2018.05.006 · Cited by 6
Fracture behavior of a composite of bone and calcium sulfate/hydroxyapatite
Kok, J., Törnquist, E., Raina, D. B., Cann, S. L., Novák, V., Širka, A., Lidgren, L., Grassi, L., & Isaksson, H. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105201 · Cited by 6
Kansal, A., Dvivedi, A., & Kumar, P. (2023) · Rapid Prototyping Journal · doi:10.1108/rpj-03-2023-0077 · Cited by 6
Acoustic propagation in a random saturated medium: the biphasic case
Gilbert, R. P., Panchenko, A., & Vasilic, A. (2013) · Applicable Analysis · doi:10.1080/00036811.2012.762091 · Cited by 6
“bone size, shape, material properties), ultrasound velocity and attenuation can give more insight in bone micro-architecture [7,8] than BMD alone.”
BackgroundProvatidis, C. G., Vossou, C., Πετροπούλου, Ε., Balanika, A. P., & Lyritis, G. P. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.12.003 · Cited by 6
Mechanics of osteoporotic trabecular bone
Bérot, M., Aurégan, J.-C., Imbert, L., Magoariec, H., Budyn, É., Zadegan, F., Hannouche, D., Bensidhoum, M., & Hoc, T. (2012) · Mechanics & Industry · doi:10.1051/meca/2012023 · Cited by 6
“All these results were obtained in the case of human femoral neck in compression [38,39] and in the case of a numerical study using results from experimental tests [19].”
ResultFinite element modeling in the musculoskeletal system: generic overview
Ren, L., & Qian, Z. (2014) · Elsevier eBooks · doi:10.1533/9780857096739.1.12 · Cited by 6
Statistical Shape and Appearance Models for Bone Quality Assessment
Raudaschl, P., & Fritscher, K. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-810493-4.00018-3 · Cited by 6
Franceschini, M., Barbera, L. L., Anticonome, A., Ottardi, C., Tanaka, A., & Villa, T. M. T. (2020) · Hip International · doi:10.1177/1120700020971312 · Cited by 6
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Self-citationDesign of a functionally graded porous uncemented acetabular component: Influence of polar gradation
Saviour, C. M., & Gupta, S. (2023) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3709 · Cited by 6
“In the case of human cancellous bone, the strain-based failure criterion is considered to be statistically powerful and mathematically simple to assess load transfer.(46) The yield strain has been reported to be uniform within each anatomic site, owing to the weak dependence on bone density.”
BackgroundSestini, M., Puppi, D., Braccini, S., Macchi, T., Matungano, B., Macolic, S., Guazzini, T., Parrini, G., Milazzo, M., & Danti, S. (2025) · Polymers · doi:10.3390/polym17070836 · Cited by 5
“It also highlights opportunities for improvement in both material properties and modeling techniques.”
Pigni, S., Vena, W., Birtolo, M. F., Fanti, A., Ulivieri, F. M., Rinaudo, L., Leonardi, L., Balzarini, L., Bossi, A. C., Pizzocaro, A., et al. (2025) · Clinical Endocrinology · doi:10.1111/cen.15301 · Cited by 5
“Material properties are assigned to each triangle in the generated mesh, with stiffness values corresponding to the local BMD, according to the empirical formulas outlined by Morgan et al. [21].”
Fan, H., Tanoto, H., Lin, P.-T., Bowles, F., Zhang, S., Liu, Z., Li, F., Klineberg, E. O., & Zhou, Y. (2025) · Extreme Mechanics Letters · doi:10.1016/j.eml.2025.102317 · Cited by 5
Computational Modeling of Trabecular Bone Mechanics
Niebur, G. L., & Keaveny, T. M. (2009) · Springer eBooks · doi:10.1007/978-90-481-3575-2_9 · Cited by 5
“Although modulus, yield stress and strength are highly correlated for trabecular bone [48, 66 ], there remains unexplained variability that is key to understanding osteoporotic fracture.”
BackgroundSelf-citationFinite element modeling to estimate the apparent material properties of trabecular bone
Park, S., Chae, S., Park, J. S., Han, S., Hong, J., & Kim, Y. (2013) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-013-0199-3 · Cited by 5
“Morgan and Keaveny’s experimental set up was similar to this research in regards to the location of the specimen and the hydration conditions used.(23) However, the fact that the specimen was maintained at -20C prior to their experiment is presumed to be the key factor for the different results obtained between their…”
ResultTAWARA, D., Noro, K., Tsujikami, T., OKAMOTO, Y., & Murakami, H. (2014) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.13-00163 · Cited by 5
“The nonlinear analysis could assess the nonlinear manner (Morgan and Keaveny, 2001, Keaveny, et al., 1994) of the vertebral mechanical behavior including differences in the tensile and compressive behaviors.”
BackgroundLatypova, A., Taghizadeh, E., Becce, F., Büchler, P., Jolles, B. M., Pioletti, D. P., & Terrier, A. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.03.017 · Cited by 5
Inacio, J. V., Cristino, D. M., Hast, M. W., & Dailey, H. L. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4051433 · Cited by 6
Subpixel Enhancement of Nonuniform Tissue (SPENT): A Novel MRI Technique for Quantifying BMD
Yiannakas, M. C., Carmichael, D. W., Farquharson, M., & Ordidge, R. J. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080911 · Cited by 5
“Thirty trabecular bone samples were cut from excised human femoral heads using radiographically predetermined locations.((24,25)) The radiographs were used to (1) identify the main trabecular orientation within the samples and (2) eliminate samples containing any pathological re-”
MethodMECHANICAL PROPERTIES OF A SINGLE CANCELLOUS BONE TRABECULAE TAKEN FROM BOVINE FEMUR
Enoki, S., Sato, M., TANAKA, K., & KATAYAMA, T. (2012) · International Journal of Modern Physics Conference Series · doi:10.1142/s201019451200342x · Cited by 5
Cole, J. H., & van der Meulen, M. C. H. (2009) · Humana Press eBooks · doi:10.1007/978-1-59745-459-9_7 · Cited by 10
Marco, M., Larrainzar‐Garijo, R., Giner, E., Caeiro, J. R., & Miguélez, M. H. (2016) · Revista de Osteoporosis y Metabolismo Mineral · doi:10.4321/s1889-836x2016000200003 · Cited by 5
Reeves, J. M., Athwal, G. S., Johnson, J. A., & Langohr, G. D. G. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4042172 · Cited by 8
Metadata
- Authors
- Morgan, E. F., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Morgan, Elise F
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 34
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2073813406
- Cited by
- 705
- References
- 37
- Citations by year
- 2026: 30 · 2025: 30 · 2024: 42 · 2023: 27 · 2022: 39 · 2021: 44 · 2020: 50 · 2019: 31 · 2018: 29 · 2017: 40 · 2016: 23 · 2015: 23 · 2014: 36 · 2013: 42 · 2012: 24
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, bone mechanical properties, vertebral bone, femoral neck, proximal tibia, bone mineral density, elastic modulus, yield stress, structure-function relationship
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Bone and Bones, Female, Femur, Femur Neck, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Models, Anatomic, Spine, Tensile Strength, Tibia, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.