Dependence of yield strain of human trabecular bone on anatomic site
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Understanding the dependence of human trabecular bone strength behavior on anatomic site provides insight into structure-function relationships and is essential to the increased success of site-specific finite element models of whole bones. To investigate the hypothesis that the yield strains of human trabecular bone depend on anatomic site, the uniaxial tensile and compressive yield properties were compared for cylindrical specimens from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27) taken from 61 donors (67+/-15years). Test protocols were used that minimized end artifacts and loaded specimens along the main trabecular orientation. Yield strains by site (mean+/-S.D.) ranged from 0.70+/-0.05% for the trochanter to 0.85+/-0.10% for the femoral neck in compression, from 0.61+/-0.05% for the trochanter to 0.70+/-0.05% for the vertebra in tension, and were always higher in compression than tension (p<0.001). The compressive yield strain was higher for the femoral neck than for all other sites (p<0.001), as was the tensile yield strain for the vertebra (p<0.007). Analysis of covariance, with apparent density as the covariate, indicated that inter-site differences existed in yield stress even after adjusting statistically for density (p<0.035). Coefficients of variation in yield strain within each site ranged from only 5-12%, consistent with the strong linear correlations (r(2)=0.94-0.98) found between yield stress and modulus. These results establish that the yield strains of human trabecular bone can differ across sites, but that yield strain may be considered uniform within a given site despite substantial variation in elastic modulus and yield stress.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The volume fraction of trabecular bone varies from 60% in primary compressive group of femoral neck to less than 10% in the elderly spine (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
9 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718 · cited 1×
“Through advancements in imaging techniques and computational methods, it is now possible to create detailed anatomic site-specific finite element models of trabecular bone specimens (Kabel et al., 1999; Ulrich et al., 1999; Zysset et al., 1998) and whole bones (Keyak and Rossi, 2000; Lotz et al.”
MethodPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“, 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 6×
“Uniaxial compressive and tensile mechanical tests were conducted at room temperature using a servohydraulic load frame (858 Mini-Bionix, MTS, Eden Prairie, MN) following protocols designed to minimize end artifacts (Keaveny et al., 1994a; Kopperdahl and Keaveny, 1998).”
BackgroundMethodResultSelf-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 1×
“, 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al., 1997; Mosekilde et al., 1987) render the strength behavior of human trabecular bone of primary medical importance.”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432 · cited 1×
“The central role of trabecular bone in the etiology of whole bone fractures (Lotz and Hayes 1990; McBroom et al., 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al.”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431 · cited 1×
“tension) in yield strains across all anatomic sites supports previous suggestions of a similarity in the yield strains between trabecular and cortical tissue (Keaveny, 1997; Niebur et al., 2000).”
ResultSelf-citation
Research works printed but not linked: 1
- Niebur, G.L., Keaveny, T.M., 2001. Trabecular bone exhibits multiple failure surfaces in biaxial loading. Transactions on Orthopaedic Research Society 26.
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
“Previously published protocols were used to obtain 8mm diameter on-axis specimens from the human vertebra, proximal tibia, and proximal femur (Kopperdahl and Keaveny, 1998; Morgan and Keaveny, 2001).”
MethodSelf-citationComparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Self-citationBone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
InfluentialSelf-citationBiomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
“, 1994), and can vary between sites (Kopperdahl and Keaveny, 1998; Morgan and Keaveny, 2001).”
BackgroundBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Mathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
Crawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
“This could be done by modifying the current finite element model to reflect the nonlinear material properties of vertebral trabecular bone [37,38].”
BackgroundMethodSelf-citationSchileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
“, 2001), at least for the same anatomical site (Morgan and Keaveny, 2001), and tensile/ compressive asymmetry (Keaveny et al.”
BackgroundA biomechanical perspective on bone quality
Hernandez, C. J., & Keaveny, T. M. (2006) · Bone · doi:10.1016/j.bone.2006.06.001 · Cited by 319
“Datamarkedwith asterisk (*) were collected in our laboratory [25] and was converted from measured yield strength values (σult = 1.”
MethodSelf-citationMethods for Assessing Bone Quality: A Review
Donnelly, E. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1702-0 · Cited by 300
“Investigations involving an animal model or cadaveric specimens allow for direct assessment of bone strength with destructive mechanical testing [12, 33, 60, 61].”
Effects of non-enzymatic glycation on cancellous bone fragility
Tang, S. Y., Zeenath, U., & Vashishth, D. (2007) · Bone · doi:10.1016/j.bone.2006.12.056 · Cited by 283
“Previous studies have shown that trabecular architecture exhibits heterogeneities between anatomical locations [25–27] and can be a source of error in testing cancellous bone.”
BackgroundKopperdahl, D. L., Morgan, E. F., & Keaveny, T. M. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00185-1 · Cited by 267
Self-citationFinite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
Orwoll, E. S., Marshall, L. M., Nielson, C. M., Cummings, S. R., Lapidus, J., Cauley, J. A., Ensrud, K., Lane, N., Hoffmann, P. R., Kopperdahl, D. L., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081201 · Cited by 265
Self-citationKivell, T. L. (2016) · Journal of Anatomy · doi:10.1111/joa.12446 · Cited by 239
“…skeleton, capable of coping with the significantly higher compressive strain compared with the proximal tibia, vertebrae and femoral trochanter (Morgan & Keaveny, 2001; Morgan et al. 2003; also see Amling et al. 1996) and carry approximately 50% of the compressive load at midneck (Lotz et al.…”
BackgroundLiu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., Bevill, G., Keaveny, T. M., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.071009 · Cited by 239
Self-citationTorres-Sanchez, C., Al Mushref, F. R. A., Norrito, M., Yendall, K., Liu, Y., & Conway, P. P. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.03.249 · Cited by 217
“2GPa, more typically 2-5GPa, and 11-24MPa, respectively [5-8].”
BackgroundKeaveny, T. M., Hoffmann, P. F., Singh, M., Palermo, L., Bilezikian, J. P., Greenspan, S. L., & Black, D. M. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080805 · Cited by 218
“ABSTRACT: The “PTH and Alendronate” or “PaTH” study compared the effects of PTH(1-84) and/or alendronate (ALN) in 238 postmenopausal, osteoporotic women.”
BackgroundInfluentialSelf-citationDumas, M., Terriault, P., & Brailovski, V. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.02.021 · Cited by 206
Liu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., & Guo, X. E. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060716 · Cited by 207
Patel, P. S., Shepherd, D. E., & Hukins, D. W. (2008) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-9-137 · Cited by 197
Nonlinear Finite Element Model Predicts Vertebral Bone Strength and Fracture Site
Imai, K., Ohnishi, I., Bessho, M., & Nakamura, K. (2006) · Spine · doi:10.1097/01.brs.0000225993.57349.df · Cited by 196
Pore functionally graded Ti6Al4V scaffolds for bone tissue engineering application
Wang, S., Liu, L., Li, K., Zhu, L., Chen, J., & Hao, Y. (2019) · Materials & Design · doi:10.1016/j.matdes.2019.107643 · Cited by 199
Liu, L., & Morgan, E. F. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.04.019 · Cited by 189
“Under the stipulation that a strain measurement technique can reliably measure strains equal to or greater than ten times the error, the MLE method can measure strains as small as approximately half the yield strain (~7000 με (Morgan and Keaveny, 2001)) in some bone types (e.g. HVB, BDF).”
MethodSelf-citationCarluccio, D., Xu, C., Venezuela, J., Cao, Y., Kent, D., Bermingham, M., Demir, A. G., Previtali, B., Ye, Q., & Dargusch, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.12.018 · Cited by 195
Compressive behaviour of child and adult cortical bone
Öhman, C., Baleani, M., Pani, C., Taddei, F., Alberghini, M., Viceconti, M., & Manfrini, M. (2011) · Bone · doi:10.1016/j.bone.2011.06.035 · Cited by 181
“For two of the studies [38,39], it cannot be excluded that the differences found with the present onewas due to the different behaviour of cortical and trabecular bone.”
BackgroundResultSimpson, R. L., Wiria, F. E., Amis, A. A., Chua, C. K., Leong, K. F., Hansen, U. N., Chandrasekaran, M., & Lee, M. W. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30839 · Cited by 181
Age-dependence of femoral strength in white women and men
Keaveny, T. M., Kopperdahl, D. L., Melton, L. J., Hoffmann, P. F., Amin, S., Riggs, B. L., & Khosla, S. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091033 · Cited by 171
Self-citationOnal, E., Frith, J., Jurg, M., Wu, X., & Molotnikov, A. (2018) · Metals · doi:10.3390/met8040200 · Cited by 172
“4 GPa [59,60]) and cortical bones (3–20 GPa [5,24]).”
BackgroundZhang, L., Song, B., Yang, L., & Shi, Y. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.05.038 · Cited by 164
Zhang, X.-Y., Fang, G., Xing, L.-L., Liu, W., & Zhou, J. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.07.064 · Cited by 162
Bouxsein, M. L., Melton, L. J., Riggs, B. L., Muller, J., Atkinson, E. J., Oberg, A. L., Robb, R. A., Camp, J. J., Rouleau, P. A., McCollough, C. H., et al. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060606 · Cited by 153
“Briefly, assuming that bone tissue fails at a constant strain,((24,25)) the failure load for a whole bone, or its strength, is proportional to the structural rigidity at its weakest cross-section.”
BackgroundBevill, G. R., Eswaran, S. K., Gupta, A. K., Papadopoulos, P., & Keaveny, T. M. (2006) · Bone · doi:10.1016/j.bone.2006.06.016 · Cited by 151
“2% offset technique [20].”
BackgroundMethodSelf-citationBiomechanical Computed Tomography analysis (BCT) for clinical assessment of osteoporosis
Keaveny, T., Clarke, B., Cosman, F., Orwoll, E., Siris, E., Khosla, S., & Bouxsein, M. (2020) · Osteoporosis International · doi:10.1007/s00198-020-05384-2 · Cited by 117
Self-citationCarpenter, R. D., Klosterhoff, B. S., Torstrick, F. B., Foley, K. T., Burkus, J. K., Lee, C. S. D., Gall, K., Guldberg, R. E., & Safranski, D. L. (2018) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2018.01.017 · Cited by 143
“Importantly, the strains produced by the porous PEEK remained below thresholds where fracture, fatigue failure, or inhibition of new bone formation can occur (5000–10,000 microstrain) (Miller et al., 2015; Morgan and Keaveny, 2001; Carter et al., 1981).”
BackgroundTrabecular plates and rods determine elastic modulus and yield strength of human trabecular bone
Wang, J., Zhou, B., Liu, X. S., Fields, A. J., Sanyal, A., Shi, X., Adams, M. F., Keaveny, T. M., & Guo, X.-D. E. (2014) · Bone · doi:10.1016/j.bone.2014.11.006 · Cited by 144
“5 mm were prepared from proximal tibiae and femurs along the main trabecular orientation [20].”
Self-citationTeo, J. C. M., Si-Hoe, K. M., Keh, J. E. L., & Teoh, S. H. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.11.001 · Cited by 161
“92) Morgan and Keaveny (2001) HT 5.”
InfluentialVertebral Osteoporosis and Trabecular Bone Quality
Donnell, P. M., McHugh, P. E., & Mahoney, D. O. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9239-9 · Cited by 164
Landi, E., Valentini, F., & Tampieri, A. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.05.023 · Cited by 139
“The compressive E values of the ceramic and biohybrid scaffolds were comparable with those reported in the literature for human trabecular bone belonging to different anatomic sites, in particular vertebra (344 ± 148 MPa [16]), proximal tibia (1091 ± 634 [16] and 445 ± 257 MPa [14]) and femur (389 ± 270 MPa [14]).”
ResultMicro-CT finite element model and experimental validation of trabecular bone damage and fracture
Hambli, R. (2013) · Bone · doi:10.1016/j.bone.2013.06.028 · Cited by 136
“All the specimens were machined such that the main trabecular orientation was aligned with the axis of the core [57].”
BackgroundBevill, G. R., & Keaveny, T. M. (2008) · Bone · doi:10.1016/j.bone.2008.11.020 · Cited by 136
“All specimens were machined such that the main trabecular orientation was aligned with the axis of the core [11].”
BackgroundSelf-citationLee, C. A., & Einhorn, T. A. (2001) · Elsevier eBooks · doi:10.1016/b978-012470862-4/50002-7 · Cited by 143
Lee, D. C., Hoffmann, P. F., Kopperdahl, D. L., & Keaveny, T. M. (2017) · Bone · doi:10.1016/j.bone.2017.07.029 · Cited by 133
Self-citationStandardizing compression testing for measuring the stiffness of human bone
Zhao, S., Arnold, M. C. A., Ma, S., Abel, R. L., Cobb, J. P., Hansen, U. N., & Boughton, O. R. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.78.bjr-2018-0025.r1 · Cited by 151
Biomechanical effects of intraspecimen variations in tissue modulus for trabecular bone
Jaasma, M. J., Bayraktar, H. H., Niebur, G. L., & Keaveny, T. M. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00193-2 · Cited by 145
Self-citationCrawford, R. P., Rosenberg, W. S., & Keaveny, T. M. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1589772 · Cited by 121
Self-citationKeaveny, T. M., McClung, M. R., Genant, H. K., Zanchetta, J. R., Kendler, D., Brown, J. P., Goemaere, S., Recknor, C., Brandi, M. L., Eastell, R., et al. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2024 · Cited by 117
Self-citationDensity and mechanical properties of vertebral trabecular bone—A review
Öhman‐Mägi, C., Holub, O., Wu, D., Hall, R. M., & Persson, C. (2021) · JOR Spine · doi:10.1002/jsp2.1176 · Cited by 135
“121 ± 97 (4-261) 6F, 9M, 46-91y Platen Cylinder 58”
InfluentialZainelabdeen, I. H., Ismail, L., Mohamed, O. F., Khan, K. A., & Schiffer, A. (2024) · Materials Science and Engineering A · doi:10.1016/j.msea.2024.146833 · Cited by 127
Matsuura, M., Eckstein, F., Lochmüller, E.-M., & Zysset, P. K. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0073-7 · Cited by 117
“Morgan and Keaveny (2001) measured yield strains inthesamerangeatfouranatomicallocationsandfound significant differences between sites with the lowest value at the femoral trochanter.”
BackgroundZheng, J., Zhao, H., Ouyang, Z., Zhou, X., Kang, J., Yang, C., Sun, C., Xiong, M., Fu, M., Jin, D., et al. (2021) · Composites Part B Engineering · doi:10.1016/j.compositesb.2021.109508 · Cited by 123
Abdullah, M. R., Goharian, A., Kadir, M. R. A., & Wahit, M. U. (2015) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35480 · Cited by 115
Goda, I., Assidi, M., & Ganghoffer, J. (2013) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0486-z · Cited by 114
Alginate based hydrogel inks for 3D bioprinting of engineered orthopedic tissues
Murab, S., Gupta, A., Włodarczyk‐Biegun, M. K., Kumar, A., van Rijn, P., Whitlock, P. W., Han, S. S., & Agrawal, G. (2022) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2022.119964 · Cited by 115
Mechanisms of uniformity of yield strains for trabecular bone
Bayraktar, H. H., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.045 · Cited by 127
“The 27 specimens that were used to obtain apparent-level mechanical data (Morgan and Keaveny, 2001) were also the origin of the twelve human femoral neck specimens.”
BackgroundSelf-citationAssociation of hip strength estimates by finite-element analysis with fractures in women and men
Amin, S., Kopperdhal, D. L., Melton, L. J., Achenbach, S. J., Therneau, T. M., Riggs, B. L., Keaveny, T. M., & Khosla, S. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.347 · Cited by 118
Self-citationCell and protein compatible 3D bioprinting of mechanically strong constructs for bone repair
Sawkins, M. J., Mistry, P., Brown, B. N., Shakesheff, K. M., Bonassar, L. J., & Yang, J. (2015) · Biofabrication · doi:10.1088/1758-5090/7/3/035004 · Cited by 105
Comparison of non-invasive assessments of strength of the proximal femur
Jóhannesdóttir, F., Thrall, E., Muller, J. A., Keaveny, T. M., Kopperdahl, D. L., & Bouxsein, M. (2017) · Bone · doi:10.1016/j.bone.2017.07.023 · Cited by 113
Self-citationSimilarity in the fatigue behavior of trabecular bone across site and species
Haddock, S. M., Yeh, O. C., Mummaneni, P. V., Rosenberg, W. S., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00245-8 · Cited by 128
Self-citationDall’Ara, E., Barber, D. C., & Viceconti, M. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.07.019 · Cited by 108
“Considering that bone yields at 7000–8000 mε (Morgan and Keaveny, 2001; Morgan et al., 2001), such accuracy and precision would be sufficient to discriminate the regions that start yielding but in order to study the elastic regime, a larger NS should be used, reducing the ability of describing the local strain close t…”
BackgroundDigital Volume Correlation for Study of the Mechanics of Whole Bones
Hussein, A. I., Barbone, P. E., & Morgan, E. F. (2012) · Procedia IUTAM · doi:10.1016/j.piutam.2012.05.013 · Cited by 124
Self-citationSpece, H., Yu, T., Law, A., Marcolongo, M. S., & Kurtz, S. M. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103850 · Cited by 107
Zheng, J., Zhao, H., Dong, E., Kang, J., Liu, C., Sun, C., Li, D., & Wang, L. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.112333 · Cited by 106
Can Dental Cone Beam Computed Tomography Assess Bone Mineral Density?
Kim, D. (2014) · Journal of Bone Metabolism · doi:10.11005/jbm.2014.21.2.117 · Cited by 118
“[23,24] Mechanical properties of trabecular bone are explained using three-dimensional (3D) morphological parameters of trabecular bone such as trabecular number, thickness, and anisotropy ratio.[25-27] Recently, many studies have also indicated that TMD is responsible for controlling elastic, plastic, and viscoelasti…”
BackgroundGetting PEEK to Stick to Bone: The Development of Porous PEEK for Interbody Fusion Devices
Torstrick, F. B., Safranski, D. L., Burkus, J. K., Chappuis, J. L., Lee, C. S. D., Guldberg, R. E., Gall, K., & Smith, K. E. (2017) · Techniques in Orthopaedics · doi:10.1097/bto.0000000000000242 · Cited by 105
Majumder, S., Roychowdhury, A., & Pal, S. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.001 · Cited by 104
Verhulp, E. E., van Rietbergen, B., Müller, R., & Huiskes, R. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.02.032 · Cited by 102
“Earlier studies found that trabecular tissue and apparent level yield strains are mostly uniform within an anatomic site (Kopperdahl and Keaveny, 1998; Morgan and Keaveny, 2001; Turner, 1989; Bayraktar and Keaveny, 2004b).”
BackgroundBryan, R., Nair, P. B., & Taylor, M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.038 · Cited by 117
“(Morgan and Keaveny, 2001).”
BackgroundMethodInfluentialTotal ankle replacement design and positioning affect implant-bone micromotion and bone strains
Sopher, R., Amis, A. A., Calder, J. D., & Jeffers, J. R. T. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.01.022 · Cited by 100
Kang, M., Lee, H., Jang, T., Seong, Y., Kim, H., Koh, Y., Song, J., & Jung, H. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.045 · Cited by 100
The Modified Super-Ellipsoid Yield Criterion for Human Trabecular Bone
Bayraktar, H. H., Gupta, A., Kwon, R. Y., Papadopoulos, P., & Keaveny, T. M. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1763177 · Cited by 99
“Within an anatomic site, it has been established that yield strains for trabecular bone under uniaxial [10], axial-shear [20] and biaxial loads [15] are independent of volume fraction, and that effects of architecture on uniaxial yield strains are minimal [21, 22].”
BackgroundSelf-citationBiomechanics of the ankle joint and clinical outcomes of total ankle replacement
Michael, J. M., Golshani, A., Gargac, S., & Goswami, T. (2008) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2008.01.005 · Cited by 99
Sawatari, T., Tsumura, H., Iesaka, K., Furushiro, Y., & Torisu, T. (2005) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.06.007 · Cited by 104
Multi-scale modelling of elastic moduli of trabecular bone
Hamed, E., Jasiuk, I., Yoo, A. C., Lee, Y., & Liszka, T. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0814 · Cited by 109
Naylor, K. E., McCloskey, E. V., Eastell, R., & Yang, L. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1856 · Cited by 104
“Material properties were then derived from vBMD by using the empirical equations of Morgan and colleagues.((21,22)) The FE boundary conditions simulated a fall on the greater trochanter: peak impact force (Fpeak) was applied to the greater trochanter, with prevention of medial displacement of the femoral head and prev…”
MethodDopico-González, C., New, A., & Browne, M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.039 · Cited by 96
“…and hence it was neglected for the present study; some studies have suggested the use of strainbased failure criteria as fracture predictors (Wong et al., 2001; Kopperdahl, 1999; Schileo et al., 2007; Morgan and Keaveny, 2001; Bayraktar et al., 2004), similar to that adopted in the present work.”
ResultPrediction of incident vertebral fracture using CT-based finite element analysis
Allaire, B. T., Lu, D., Johannesdottir, F., Kopperdahl, D., Keaveny, T. M., Jarraya, M., Guermazi, A., Bredella, M. A., Samelson, E. J., Kiel, D. P., et al. (2019) · Osteoporosis International · doi:10.1007/s00198-018-4716-1 · Cited by 95
Self-citationRelative roles of microdamage and microfracture in the mechanical behavior of trabecular bone
Yeh, O. C., & Keaveny, T. M. (2001) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00053-5 · Cited by 93
Self-citationMajumder, S., Roychowdhury, A., & Pal, S. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.07.001 · Cited by 93
Evaluation of macrostructural bone biomechanics
Beaupied, H., Lespessailles, É., & Benhamou, C.-L. (2007) · Joint Bone Spine · doi:10.1016/j.jbspin.2007.01.019 · Cited by 113
Lambers, F. M., Bouman, A. R., Rimnac, C. M., & Hernandez, C. J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0083662 · Cited by 86
“Little variation in mechanical properties has been observed among anterior, left and right sites within lumbar vertebrae [35,36,37].”
BackgroundBuilding structure into engineered tissues
Isenberg, B. C., & Wong, J. Y. (2006) · Materials Today · doi:10.1016/s1369-7021(06)71743-6 · Cited by 90
Shear strength behavior of human trabecular bone
Sanyal, A., Gupta, A. K., Bayraktar, H. H., Kwon, R. Y., & Keaveny, T. M. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.07.023 · Cited by 87
“0 (Carter and Hayes, 1976; Morgan and Keaveny, 2001).”
BackgroundSelf-citationZhou, B., Liu, X. S., Wang, J., Lu, X. L., Fields, A. J., & Guo, X. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.11.039 · Cited by 85
“Briefly, digital topological analysis (DTA)based skeletonization was applied first to transform a trabecular bone image into a reduced structure composed of only single layer of skeleton voxels while preserving the trabecular bone topology (Saha and Chaudhuri, 1994; Saha et al., 1994, 1997).”
Edwards, W. B., Schnitzer, T. J., & Troy, K. L. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.04.016 · Cited by 85
“Additionally, Hill's criterion does not account for tension-compression yield asymmetry (Morgan and Keaveny, 2001) and perhaps implementation of the Tsai-Wu criterion (Tsai and Wu, 1971) – an extension of Hill's criterion that accounts for tension-compression asymmetry – would improve our…”
BackgroundNatural load-bearing protein materials
Harrington, M. J., & Fratzl, P. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100767 · Cited by 87
Bone remodelling inside a cemented resurfaced femoral head
Gupta, S., New, A., & Taylor, M. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.01.010 · Cited by 84
“Strain was preferred to stress, as trabecular bone has been reported to have a uniform yield strain within a given site regardless of variation in bone density, elastic modulus and yield stress (Morgan and Keaveny, 2001).”
BackgroundPerillo‐Marcone, A., & Taylor, M. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2401177 · Cited by 87
Empirical relationships between bone density and ultimate strength: A literature review
Fleps, I., Bahaloo, H., Zysset, P. K., Ferguson, S. J., Pálsson, H., & Helgason, B. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103866 · Cited by 85
Mechanical properties of hydroxyapatite whisker reinforced polyetherketoneketone composite scaffolds
Converse, G. L., Conrad, T. L., & Roeder, R. K. (2009) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2009.07.002 · Cited by 81
Contribution of inter-site variations in architecture to trabecular bone apparent yield strains
Morgan, E. F., Bayraktar, H. H., Yeh, O. C., Majumdar, S., Burghardt, A. J., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.037 · Cited by 92
“In contrast, modulus and yield stress depend heavily on density and exhibit coefficients of variation per site of up to 70% (Linde et al., 1989; Morgan and Keaveny, 2001; Mosekilde et al., 1987).”
BackgroundMethodSelf-citationDamage accumulation in vertebral trabecular bone depends on loading mode and direction
Wolfram, U., Wilke, H., & Zysset, P. K. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.01.018 · Cited by 84
“Load rates for quasi-static testing in this study have been slower than rates reported earlier (Bayraktar et al., 2004; Morgan and Keaveny, 2001; Morgan et al., 2005; Rincón-Kohli and Zysset, 2009).”
ResultTeo, J. C. M., Si-Hoe, K. M., Keh, J. E. L., & Teoh, S. H. (2006) · Materials Science and Engineering C · doi:10.1016/j.msec.2006.05.003 · Cited by 82
How can bone turnover modify bone strength independent of bone mass?
Hernandez, C. J. (2008) · Bone · doi:10.1016/j.bone.2008.02.001 · Cited by 93
“48 [22] or as large as 2.”
Zhang, X. H., Liu, X. S., Vasilic, B., Wehrli, F. W., Benito, M., Rajapakse, C. S., Snyder, P. J., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080405 · Cited by 79
Yang, L., Palermo, L., Black, D. M., & Eastell, R. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2291 · Cited by 85
“598),((22)) and derived material properties from rapp by using the empirical equations of Morgan and colleagues((23,24)):”
MethodMimicking bone microenvironment: 2D and 3D in vitro models of human osteoblasts
Yuste, I., Luciano, F. C., González‐Burgos, E., Lalatsa, A., & Serrano, D. R. (2021) · Pharmacological Research · doi:10.1016/j.phrs.2021.105626 · Cited by 83
Ferguson, S. J., Visser, J. M. A., & Polikeit, A. (2005) · European Spine Journal · doi:10.1007/s00586-005-0915-5 · Cited by 79
“[26], so the possibility of local bone changes in response to mechanical loading cannot be excluded and implant subsidence may occur.”
BackgroundFollet, H., Viguet‐Carrin, S., Burt‐Pichat, B., Dépalle, B., Bala, Y., Gineyts, É., Munoz, F., ARLOT, M. E., Boivin, G., Chapurlat, R. D., et al. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21275 · Cited by 79
Specimen-specific modeling of hip fracture pattern and repair
Ali, A. A., Cristofolini, L., Schileo, E., Hu, H., Taddei, F., Kim, R. H., Rullkoetter, P. J., & Laz, P. J. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.10.033 · Cited by 83
“trochanter (Morgan and Keaveny, 2001).”
BackgroundInfluentialHsu, M., Chen, F.-C., Kao, H.-C., & Cheng, C. (2007) · PubMed · Cited by 77
Metadata
- Authors
- Morgan, E. F., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Morgan, Elise F
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 34
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2073813406
- Cited by
- 705
- References
- 37
- Citations by year
- 2026: 30 · 2025: 30 · 2024: 42 · 2023: 27 · 2022: 39 · 2021: 44 · 2020: 50 · 2019: 31 · 2018: 29 · 2017: 40 · 2016: 23 · 2015: 23 · 2014: 36 · 2013: 42 · 2012: 24
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, bone mechanical properties, vertebral bone, femoral neck, proximal tibia, bone mineral density, elastic modulus, yield stress, structure-function relationship
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Bone and Bones, Female, Femur, Femur Neck, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Models, Anatomic, Spine, Tensile Strength, Tibia, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.