Dependence of yield strain of human trabecular bone on anatomic site
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Understanding the dependence of human trabecular bone strength behavior on anatomic site provides insight into structure-function relationships and is essential to the increased success of site-specific finite element models of whole bones. To investigate the hypothesis that the yield strains of human trabecular bone depend on anatomic site, the uniaxial tensile and compressive yield properties were compared for cylindrical specimens from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27) taken from 61 donors (67+/-15years). Test protocols were used that minimized end artifacts and loaded specimens along the main trabecular orientation. Yield strains by site (mean+/-S.D.) ranged from 0.70+/-0.05% for the trochanter to 0.85+/-0.10% for the femoral neck in compression, from 0.61+/-0.05% for the trochanter to 0.70+/-0.05% for the vertebra in tension, and were always higher in compression than tension (p<0.001). The compressive yield strain was higher for the femoral neck than for all other sites (p<0.001), as was the tensile yield strain for the vertebra (p<0.007). Analysis of covariance, with apparent density as the covariate, indicated that inter-site differences existed in yield stress even after adjusting statistically for density (p<0.035). Coefficients of variation in yield strain within each site ranged from only 5-12%, consistent with the strong linear correlations (r(2)=0.94-0.98) found between yield stress and modulus. These results establish that the yield strains of human trabecular bone can differ across sites, but that yield strain may be considered uniform within a given site despite substantial variation in elastic modulus and yield stress.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The volume fraction of trabecular bone varies from 60% in primary compressive group of femoral neck to less than 10% in the elderly spine (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
9 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718 · cited 1×
“Through advancements in imaging techniques and computational methods, it is now possible to create detailed anatomic site-specific finite element models of trabecular bone specimens (Kabel et al., 1999; Ulrich et al., 1999; Zysset et al., 1998) and whole bones (Keyak and Rossi, 2000; Lotz et al.”
MethodPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“, 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 6×
“Uniaxial compressive and tensile mechanical tests were conducted at room temperature using a servohydraulic load frame (858 Mini-Bionix, MTS, Eden Prairie, MN) following protocols designed to minimize end artifacts (Keaveny et al., 1994a; Kopperdahl and Keaveny, 1998).”
BackgroundMethodResultSelf-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 1×
“, 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al., 1997; Mosekilde et al., 1987) render the strength behavior of human trabecular bone of primary medical importance.”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432 · cited 1×
“The central role of trabecular bone in the etiology of whole bone fractures (Lotz and Hayes 1990; McBroom et al., 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al.”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431 · cited 1×
“tension) in yield strains across all anatomic sites supports previous suggestions of a similarity in the yield strains between trabecular and cortical tissue (Keaveny, 1997; Niebur et al., 2000).”
ResultSelf-citation
Research works printed but not linked: 1
- Niebur, G.L., Keaveny, T.M., 2001. Trabecular bone exhibits multiple failure surfaces in biaxial loading. Transactions on Orthopaedic Research Society 26.
Cited by
Items 301–400 of 732
Mg-based porous metals as cancellous bone analogous material: A review
Jasmawati, N., Januddi, F., Putra, A., Syahrom, A., Harun, M., Öchsner, A. Ö., & Kadir, M. R. A. (2015) · Proceedings of the Institution of Mechanical Engineers Part L Journal of Materials Design and Applications · doi:10.1177/1464420715624449 · Cited by 23
“The proportion of cancellous bone in the human body is dependent on the site of the skeletal system.(2,3) The cancellous struts are sparsely organized and oriented based on direction of mechanical stress bore by the bone, giving the cancellous structure a higher surface area with lower mass when compared to the compac…”
BackgroundMultiscale response of the human skull to quasi-static compression
Alexander, S. L., Gunnarsson, C. A., Rafaels, K. A., & Weerasooriya, T. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103492 · Cited by 21
Association of vertebral endplate microstructure with bone strength in men and women
McKay, M., Jackman, T. M., Hussein, A. I., Guermazi, A., Liu, J., & Morgan, E. F. (2019) · Bone · doi:10.1016/j.bone.2019.115147 · Cited by 21
Self-citationAnisotropic computational modelling of bony structures from CT data: An almost automatic procedure
Toniolo, I., Salmaso, C., Bruno, G., STEFANI, A. D., Stefanini, C., Gracco, A. L. T., & Carniel, E. L. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105319 · Cited by 22
Transversely Isotropic Elasticity Imaging of Cancellous Bone
Shore, S. W., Barbone, P. E., Oberai, A. A., & Morgan, E. F. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004231 · Cited by 22
“Second, the result of the reconstruction is a distribution of secant modulus, rather than tangent modulus, because the applied deformation of 2:0% strain corresponds to more than twice the compressive yield strain of human vertebral cancellous bone (0:77%) [26].”
BackgroundInfluentialSelf-citationYang, L., Parimi, N., ORWOLL, E. S., Black, D., Schousboe, J. T., & Eastell, R. (2017) · Osteoporosis International · doi:10.1007/s00198-017-4319-2 · Cited by 20
“04% for femoral trabecular bone [27] was used to calculate strain ratio of εpc to εyield for each element.”
Long-TermIn VitroDegradation of a High-Strength Brushite Cement in Water, PBS, and Serum Solution
Ajaxon, I., Öhman‐Mägi, C., & Persson, C. (2015) · BioMed Research International · doi:10.1155/2015/575079 · Cited by 20
“The compressive strength decreased almost linearly over time but was still after 25 weeks higher than 20MPa, that is, higher than reported trabecular bone strengths [37–39].”
BackgroundRothstock, S., de Uhlenbrock, A. G., Bishop, N. E., & Morlock, M. M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.052 · Cited by 20
“Table 1 Isotropic plastic deformation (Yield Strain: 0.85%; Morgan and Keaveny, 2001) with parameters for the bilinear plastic FE model at discrete density values.”
BackgroundMethodInfluentialSensitivity of Vertebral Compressive Strength to Endplate Loading Distribution
Buckley, J. M., Leang, D. C., & Keaveny, T. M. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2241637 · Cited by 20
Self-citationAlterations in damage processes in dense cancellous bone following gamma-radiation sterilization
Dux, S. J., Ramsey, D. S., Chu, E. H., Rimnac, C. M., & Hernandez, C. J. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.042 · Cited by 20
“In such situations platens testing is appropriate (Morgan and Keaveny, 2001).”
BackgroundMethodMaintenance of bone mass and architecture in denning black bears ( Ursus americanus )
Pardy, C. K., Wohl, G. R., Ukrainetz, P. J., Sawers, A., Boyd, S. K., & Zernicke, R. F. (2004) · Journal of Zoology · doi:10.1017/s0952836904005412 · Cited by 20
Finite element analysis of total knee replacement considering gait cycle load and malalignment
Shi, J. (2007) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 20
On the human vertebra computational modeling: a literature review
Molinari, L., & Falcinelli, C. (2021) · Meccanica · doi:10.1007/s11012-021-01452-x · Cited by 19
“The authors also included an isotropic hardening rule with a 95% reduction in the post yield modulus (Eyield) described by the following relation [112]:”
BackgroundSmith, A. N., Ulsh, J. B., Gupta, R., Tang, M. M., Peredo, A. P., Teinturier, T. D., Mauck, R. L., Gullbrand, S. E., & Hast, M. W. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106457 · Cited by 21
Wang, Y., Hou, Y., Vyas, C., Huang, B., & Bártolo, P. (2025) · Materials Futures · doi:10.1088/2752-5724/adb7f6 · Cited by 21
“In particular, the PCL/TCP scaffold has ∼ 7 MPa compressive modulus aligning with the range of the native subchondral bone modulus (10–3000 MPa) [52–54].”
Unnikrishnan, G. U., & Morgan, E. F. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004190 · Cited by 20
Self-citationRothstock, S., de Uhlenbrock, A. G., Bishop, N. E., LAIRD, L., Nassutt, R., & Morlock, M. M. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.02.076 · Cited by 19
“Peak strain alone is not sufficient to characterize the failure probability of bone and thus also the volume of overstrained bone was evaluated based on failure thresholds (Morgan and Keaveny, 2001).”
BackgroundInfluentialBaumann, A. P., Shi, X., Roeder, R. K., & Niebur, G. L. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2015.1041022 · Cited by 21
Biodegradable nanocomposite Fe–Ag load-bearing scaffolds for bone healing
Sharipova, A. F., Gotman, I., Psakhie, S. G., & Gutmanas, E. Y. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.06.033 · Cited by 19
Yu, Y., Hu, Y., Zhou, B., Wang, J., & Guo, X.-D. E. (2020) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.4338 · Cited by 20
“harvested from each specimen along the principle trabecular direction,((29)) sprayed with 0.”
MethodA biomechanical study of proximal tibia bone grafting through the lateral approach
Lim, C. T., Ng, D. Q. K., Tan, K. J., Ramruttun, A. K., Wang, W., & Chong, D. Y. R. (2016) · Injury · doi:10.1016/j.injury.2016.09.017 · Cited by 19
Zhang, Q., Sun, C., Zheng, J., Wang, L., Liu, C., & Li, D. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106848 · Cited by 18
Blumenfeld, J., Studholme, C., Carballido‐Gamio, J., Carpenter, R. D., Link, T. M., & Majumdar, S. (2008) · Medical Physics · doi:10.1118/1.2977764 · Cited by 18
Compression moulding and injection over moulding of porous PEEK components
Siddiq, A. R., & Kennedy, A. R. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103996 · Cited by 18
Panagiotopoulou, V. C., Ovesy, M., Gueorguiev, B. G., Richards, R. G., Zysset, P. K., & Varga, P. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104344 · Cited by 18
Gupta, S., Pal, B., & New, A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0007-5 · Cited by 18
The Quartic Piecewise-Linear Criterion for the Multiaxial Yield Behavior of Human Trabecular Bone
Sanyal, A., Scheffelin, J., & Keaveny, T. M. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029109 · Cited by 19
Self-citationThree-dimensional rendering of trabecular bone microarchitecture using a probabilistic approach
Kirby, M. L., Morshed, A. H., Gomez, J., Xiao, P., Hu, Y., Guo, X.-D. E., & Wang, X. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-020-01286-8 · Cited by 18
“Currently, there are two different approaches for developing digital trabecular bone models (Keaveny et al. 2001; Jensen et al. 1990; Yeh and Keaveny 1999; Kowalczyk 2003; Roberts and Garboczi 2002; Silva and Gibson 1997).”
BackgroundMethodInfluentialNanoscale mechanisms in age-related hip-fractures
Ma, S., Goh, E. L., Tay, T., Wiles, C. C., Boughton, O. R., Churchwell, J. H., Wu, Y., Karunaratne, A., Bhattacharya, R., Terrill, N. J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-69783-5 · Cited by 18
Cell Structure and Biology of Bone and Cartilage
Walsh, W. R., Walton, M., Bruce, W. J. M., Yu, Y. Y., Gillies, R. M., & Svehla, M. (2003) · Humana Press eBooks · doi:10.1007/978-1-59259-417-7_2 · Cited by 35
Bioactive Polyaryletherketone Composites
Roeder, R. K., & Conrad, T. L. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-4463-7.10011-9 · Cited by 18
3D-DXA Based Finite Element Modelling for Femur Strength Prediction: Evaluation Against QCT.
Qasim, M., Picazo, M. L., Wills, C. R., Noailly, J., Gregorio, S. D., Barquero, L. M. D. R., Malouf, J., & Humbert, L. (2024) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2024.101471 · Cited by 18
Anisotropic bone remodeling of a biomimetic metal-on-metal hip resurfacing implant
Caouette, C., Bureau, M., Vendittoli, P., Lavigne, M. J. F., & Nuño, N. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.08.015 · Cited by 17
“Strain shielding was preferred to stress shielding to compare the models because uniaxial yield strain of bone is uniform within an anatomic site [20,32] and is also believed to be isotropic [32]: this makes principal strains a useable site-independent “yield criterion” for bone material.”
BackgroundResultLee, C.-H., Landham, P. R., Eastell, R., Adams, M. A., Dolan, P., & Yang, L. (2017) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411917708806 · Cited by 17
“Following the technique of Keyak et al.39 and Lotz et al.40,41 vertebral strength was defined as the load that causes the stress/strain in a contiguous volume of 7.53 7.53 7.5mm3 to exceed the failure criteria.”
MethodInfluentialSajjadinia, S. S., Haghpanahi, M., & Razi, M. (2019) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411919854011 · Cited by 17
Exploratory Full-Field Strain Analysis of Regenerated Bone Tissue from Osteoinductive Biomaterials
Fernández, M. P., Black, C. R. M., Dawson, J. I., Gibbs, D., Kanczler, J. M., Oreffo, R. O. C., & Tozzi, G. (2020) · Materials · doi:10.3390/ma13010168 · Cited by 19
Is the 0.2%-Strain-Offset Approach Appropriate for Calculating the Yield Stress of Cortical Bone?
Zhang, G., Luo, J., Zheng, G., Bai, Z., Cao, L., & Mao, H. (2021) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02719-2 · Cited by 17
Cavazzoni, G., Cristofolini, L., Dall’Ara, E., & Palanca, M. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1152358 · Cited by 17
“A nodal spacing of 50 voxels was identified as the best compromise between the SDER and the measurement spatial resolution as it is the smallest measurement spatial resolution that ensure acceptably low measurement uncertainties, at least an order of magnitude lower than those at failure (~7000 με in tensile and ~1000…”
BackgroundA Variation of Particle Swarm Optimization for Training of Artificial Neural Networks
Zamani, M., & Sadeghi, A. (2010) · InTech eBooks · doi:10.5772/7819 · Cited by 17
Fang, G., Ji, B., Liu, X. S., & Guo, X.-D. E. (2010) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840903405660 · Cited by 19
“1994b ; Morgan and Keaveny 2001 ) and numerical simulations (Hou et al.”
BackgroundBettamer, A., Hambli, R., Allaoui, S., & Almhdie-Imjabbar, A. (2015) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2015.1079505 · Cited by 17
Can barb thread design improve the pullout strength of bone screws?
Feng, X., Qi, W., Fang, C. X., Lu, W. W., Leung, F. K. L., & Chen, B. (2021) · Bone and Joint Research · doi:10.1302/2046-3758.102.bjr-2020-0072.r2 · Cited by 17
Mechanical Properties of Human Mineralized Connective Tissues
Santis, R. D., Ambrosio, L., Mollica, F., Netti, P. A., & Nicolais, L. (2007) · Birkhäuser Boston eBooks · doi:10.1007/978-0-8176-4411-6_6 · Cited by 21
Hyperlipidemia affects multiscale structure and strength of murine femur
Ascenzi, M., Lutz, A., Du, X., Klimecky, L., Kawas, N. P., Hourany, T., Jahng, J., Chin, J., Tintut, Y., Nackenhors, U., et al. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.04.006 · Cited by 16
“6% (Morgan and Keaveny, 2001; Kaneko et al., 2003).”
MethodInfluentialExamining trabecular morphology and chemical composition of peri-scaffold osseointegrated bone
Lyu, L., Yang, S., Ye, J., Zhang, C., & Wang, J. (2020) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-020-01931-z · Cited by 16
The Mechanical Behavior of Bone
Karim, L., Hussein, A. I., Morgan, E. F., & Bouxsein, M. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-415853-5.00019-4 · Cited by 25
Self-citationYang, S., Luo, Y., Yang, L., Dall’Ara, E., Eastell, R., Goertzen, A. L., McCloskey, E. V., Leslie, W. D., & Lix, L. M. (2018) · Bone · doi:10.1016/j.bone.2018.03.005 · Cited by 16
Xie, S., Manda, K., & Pankaj, P. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.710.bjr-2018-0085.r1 · Cited by 16
Biomechanical analysis of functionally graded porous interbody cage for lumbar spinal fusion
Talukdar, R. G., Saviour, C. M., Dhara, S., & Gupta, S. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.107281 · Cited by 15
Britton, M., Monahan, G. E., Murphy, C. G., Kearns, S. R., Devitt, A. T., Okwieka, A., Jaisson, S., Gulick, L. V., Beljebbar, A., Kerdjoudj, H., et al. (2024) · Bone · doi:10.1016/j.bone.2024.117190 · Cited by 18
Comparing ceramic Fischer-Koch-S and gyroid TPMS scaffolds for potential in bone tissue engineering
Baumer, V., Isaacson, N., Kanakamedala, S., McGee, D. S., Kaze, I., & Prawel, D. A. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1410837 · Cited by 15
“Morgan and Keaveny (2001) showed that moduli varied signi fi cantly based on the strain range chosen for bone tissue and that non-linear behavior existed even at small strains.”
BackgroundMann, K. A., Miller, M. A., Goodheart, J. R., Izant, T. H., & Cleary, R. J. (2013) · Journal of Orthopaedic Research® · doi:10.1002/jor.22534 · Cited by 15
“The largest regional bone strain (3,000me) for 1 BW loading was less than the yield strain reported for trabecular and cortical bone ( 7,000me).(25,26) If we scale to load levels for level walking ( 2.”
Zheng, J., Dong, E., Kang, J., Sun, C., Liu, C., Wang, L., & Li, D. (2021) · Polymers · doi:10.3390/polym13152547 · Cited by 15
“The adjustable range of the compressive strength was similar to the variation range of the natural trabecular bone (2–17 MPa) [39,40].”
BackgroundInfluentialWang, F., Metzner, F., Zheng, L., Osterhoff, G., & Schleifenbaum, S. (2022) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-022-03265-4 · Cited by 16
“Meanwhile, human cancellous bone exhibits a high variance in mechanical properties due to the different anatomic sites [19, 20].”
BackgroundDental Implant and Natural Tooth Micro-Movements during Mastication—In Vivo Study with 3D VIC Method
Száva, D. T., Száva, A., Száva, J., Gálfi, B., & Vlase, S. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12101690 · Cited by 15
Malekmotiei, L., Farahmand, F., Shodja, H. M., & Samadi-Dooki, A. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023699 · Cited by 15
Louna, Z., Goda, I., & Ganghoffer, J. (2018) · Continuum Mechanics and Thermodynamics · doi:10.1007/s00161-018-0619-9 · Cited by 15
“, [28,32]) tried to overcome this difficulty by avoiding the fluid effect and characterize the isolated architecture.”
BackgroundTowards an App to Estimate Patient-Specific Perioperative Femur Fracture Risk
Esposito, L., Minutolo, V., Gargiulo, P., Jónsson, H., Gíslason, M. K., & Fraldi, M. (2020) · Applied Sciences · doi:10.3390/app10186409 · Cited by 15
“Finally, literature data concerning bone resistance are mainly proposed in terms of limit strain that results from experimental analysis [23-24].”
BackgroundHambli, R., & Hattab, N. (2012) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/8415_2012_146 · Cited by 19
“All the specimens were machined such that the main trabecular orientation was aligned with the axis of the core [37].”
BackgroundThe Effect of Damage on the Viscoelastic Behavior of Human Vertebral Trabecular Bone
Bredbenner, T. L., & Davy, D. T. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2205370 · Cited by 16
Klotz, M. C. M., Beckmann, N. A., Bitsch, R. G., Seebach, E., Reiner, T., & Jaeger, S. (2014) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-014-0109-0 · Cited by 15
Biomechanics of Vertebral Bone
Keaveny, T. M., & Buckley, J. M. (2006) · Elsevier eBooks · doi:10.1016/b978-012369390-7/50005-8 · Cited by 20
Self-citationMechanical properties of whole-body human bones: a review
Verma, S., Singh, G., Choudhary, A., Hussain, S., & Chanda, A. (2026) · Materials Research Express · doi:10.1088/2053-1591/ae45f3 · Cited by 14
Review on the use of medical imaging in orthopedic biomechanics: finite element studies
Barkaoui, A., Oumghar, I. A., & Kahla, R. B. (2021) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2021.1888317 · Cited by 17
Zhang, X., Zhang, D., & Wang, R. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106752 · Cited by 14
Strain rate dependency of bovine trabecular bone under impact loading at sideways fall velocity
Enns-Bray, W. S., Ferguson, S. J., & Helgason, B. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.04.042 · Cited by 15
Li, F., Chen, X., & Liu, P. (2022) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2022.0140 · Cited by 14
Patiño, J. F. R., Isaza, J. A., Mariaka, I., & Zea, J. A. V. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364611420478 · Cited by 14
Hernandez, C. J. (2016) · Springer eBooks · doi:10.1007/978-1-4939-3305-1_2 · Cited by 14
Butz, K. D., Merrell, G. A., & Nauman, E. A. (2012) · Hand · doi:10.1007/s11552-012-9430-4 · Cited by 14
“Because the mechanical properties of the cancellous bone vary considerably [17,19,20], the modulus was varied from”
BackgroundValidity of serial milling-based imaging system for microdamage quantification
Bigley, R. F., Singh, M., Hernandez, C. J., Kazakia, G. J., Martin, R. B., & Keaveny, T. M. (2007) · Bone · doi:10.1016/j.bone.2007.09.043 · Cited by 20
Self-citationTesting Two Predictions for Fracture Load Using Computer Models of Trabecular Bone
Liebschner, M. A. K., Müller, R., Wimalawansa, S. J., Rajapakse, C. S., & Gunaratne, G. H. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.057539 · Cited by 15
Elastic Anisotropy of Trabecular Bone in the Elderly Human Vertebra
Unnikrishnan, G. U., Gallagher, J. A., Hussein, A. I., Barest, G. D., & Morgan, E. F. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4031415 · Cited by 13
Self-citationKechagias, S., Munford, M. J., Masure, F. C. H., van Arkel, R. J., & Oosterbeek, R. N. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202501885 · Cited by 15
Pradeep, K., & Pal, B. (2023) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119231177346 · Cited by 13
“This range of value is physiological and far lower than the allowable yield strain reported for cancellous bone.(28,29) On the other hand, the peak von Mises strain observed on the vertebra for the GCS case was higher than the mean compressive yield strain (0.”
BackgroundHarmony, T. C. Y., Yusof, N., Ramalingam, S., Baharin, R., Syahrom, A., & Mansor, A. (2021) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000001968 · Cited by 13
Ulivieri, F. M., Rinaudo, L., Messina, C., Aliprandi, A., Sconfienza, L. M., Sardanelli, F., & Cesana, B. M. (2022) · La radiologia medica · doi:10.1007/s11547-022-01543-z · Cited by 13
“For the lumbar spine, the image was analyzed under the assumption that weight is applied on the vertebral upper plate, while a constraint to this force is located on the lower plate of the vertebrae [30].”
MethodMechanical properties of a cemented porous implant interface
Beckmann, N. A., Bitsch, R. G., Seeger, J. B., Klotz, M. C. M., Kretzer, J. P., & Jaeger, S. (2014) · Acta Orthopaedica · doi:10.3109/17453674.2014.919557 · Cited by 13
“The cancellous bone cylinders were taken from 10 fresh frozen human femoral heads from 5 donors in accordance with the recommendations of Morgan and Keaveny (2001) and Keaveny et al. (1994).”
MethodA New Vertebral Body Replacement Strategy Using Expandable Polymeric Cages
Liu, X., Paulsen, A. R., Giambini, H., Guo, J., Miller, A. L., Lin, P.-C., Yaszemski, M. J., & Lu, L. (2016) · Tissue Engineering Part A · doi:10.1089/ten.tea.2016.0246 · Cited by 13
“According to previous studies, vertebral cancellous bone has been shown to have a compressive modulus in the range of 344 – 148 MPa.55 Based on previous work from our group, the PPF material to be implemented as a core in the expandable cage, was reported to have a compressive modulus of 142 – 7.4 MPa.18 This is compa…”
BackgroundInfluentialModeling the Mechanical Consequences of Age-Related Trabecular Bone Loss by XFEM Simulation
Fan, R., Gong, H., Zhang, X., Liu, J., Jia, Z., & Zhu, D. (2016) · Computational and Mathematical Methods in Medicine · doi:10.1155/2016/3495152 · Cited by 13
Finite Element Modeling of the Spine
Bowden, A. E. (2006) · Elsevier eBooks · doi:10.1016/b978-012369390-7/50015-0 · Cited by 13
Al‐Dirini, R. M. A., Martelli, S., Huff, D. N., Ju, Z., Clement, J. G., Besier, T. F., & Taylor, M. (2018) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2018.09.002 · Cited by 13
Bone Response to Mechanical Loads
Ramaswamy, G., Bidez, M. W., & Misch, C. E. (2014) · Elsevier eBooks · doi:10.1016/b978-0-323-07845-0.00006-3 · Cited by 15
Muhayudin, N. A., Basaruddin, K. S., McEvoy, F., & Tansey, A. (2020) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2019.12.089 · Cited by 13
“Keaveny et al. and Banse et al. calculated the compressive modulus using the slope of the best-fit straight line within different ranges of strain, while others calculated within the maximum slope of the stressstrain curve [23,27,28].”
BackgroundMethodInfluentialRaftery, K. A., Kargarzadeh, A., Tavana, S., & Newell, N. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1511685 · Cited by 12
“…vertebral trabecular bone yields in compression at ~8000 µS with minimal dependency on modulus within the anatomical site (Bayraktar et al., 2004; Kopperdahl and Keaveny, 1998; Morgan and Keaveny, 2001), and is linearly related to the experienced tissue-level strains (Bayraktar et al., 2004).”
Gibson, F. G., Paggiosi, M., Handforth, C., Brown, J. E., Li, X., Dall’Ara, E., & Verbruggen, S. W. (2025) · Bone · doi:10.1016/j.bone.2025.117465 · Cited by 12
“(3)] [34], and a 95 % reduction in the post-yield elastic modulus [Eq.”
Lü, Y., Zhu, Y., Krause, M., Huber, G., & Li, J. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.05.007 · Cited by 12
Mechanical and morphometric characterization of custom-made trabecular bone surrogates
Klinger, S., Greinwald, M., Augat, P., & Hollensteiner, M. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105146 · Cited by 12
Process window for electron beam melting of Ti–42Nb wt.%
Grubova, I. Y., Kozadaeva, M., Volkova, A. P., Khrapov, D., Анатольевич, С. Р., Koptyug, A. V., Vlădescu, A., Tyurin, A., & Surmeneva, M. A. (2023) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2023.06.234 · Cited by 12
Borsinger, T. M., González, F. J. Q., Pagan, C. A., Karasavvidis, T., Sculco, P. K., Wright, T. M., Kahlenberg, C. A., Lipman, J. D., Debbi, E. M., Vigdorchik, J. M., et al. (2024) · The Journal of Arthroplasty · doi:10.1016/j.arth.2024.03.056 · Cited by 12
A patient-specific model of total knee arthroplasty to estimate patellar strain: A case study
Latypova, A., Arami, A., Becce, F., Jolles-Haeberli, B., Aminian, K., Pioletti, D. P., & Terrier, A. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.11.008 · Cited by 12
“We compared bone volume above 1% and 2% of octahedral shear strain as these strain levels are often associated with bone yield (Carter et al., 1981; Lammentausta et al., 2006; Morgan and Keaveny, 2001).”
BackgroundSilva-Henao, J. D., Rueda‐Esteban, R. J., Marañón, A., & Casas, J. P. (2020) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2020.107053 · Cited by 12
The effect of design variations on stresses in total ankle arthroplasty
Galik, K. (2002) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 19
Erdem, İ., Truumees, E., & van der Meulen, M. C. H. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.636741 · Cited by 12
“1999 ; Morgan and Keaveny 2001 ; Panzer and Cronin 2009 ).”
The use of μCT and fractal dimension for fracture prediction in osteoporotic individuals
Arnold, E. L., Clement, J. G., Rogers, K. D., García-Castro, F., & Greenwood, C. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103585 · Cited by 12
“4 Discussion Overall, values for microarchitectural characteristics (BV/TV, BS/BV, TbTh, TbSp, vBMD and TMD), fractal dimension measurements (D and D) and Ez are consistent with values within literature, both for femoral head studies (Li et al., 2012; Morgan and Keaveny, 2001; Perilli et al., 2008; Wu et al., 2015; Zh…”
ResultEffects of damage on the orthotropic material symmetry of bovine tibial trabecular bone
Liu, X., Wang, X., & Niebur, G. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00217-3 · Cited by 13
An Equivalent Constitutive Model of Cancellous Bone With Fracture Prediction
Salem, M., Westover, L., Adeeb, S., & Duke, K. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047080 · Cited by 11
Pedersini, R., Cosentini, D., Rinaudo, L., Zamparini, M., Ulivieri, F. M., di Mauro, P., Maffezzoni, F., Monteverdi, S., Vena, W., Laini, L., et al. (2022) · Bone Reports · doi:10.1016/j.bonr.2023.101654 · Cited by 11
A Novel Method of Load Bearing Ability Analysis of Short Plateau Implants Placed in Compromised Bone
Linetskiy, I., Sutcliffe, M. P. F., Kondratiev, A., Demenko, V., Linetska, L., & Yefremov, O. (2023) · IEEE KhPI Week on Advanced Technology (KhPIWeek) · doi:10.1109/khpiweek61412.2023.10312831 · Cited by 11
Chen, J., Bu, L., & Xu, G. (2024) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2024.02.014 · Cited by 11
Metadata
- Authors
- Morgan, E. F., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Morgan, Elise F
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 34
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2073813406
- Cited by
- 705
- References
- 37
- Citations by year
- 2026: 30 · 2025: 30 · 2024: 42 · 2023: 27 · 2022: 39 · 2021: 44 · 2020: 50 · 2019: 31 · 2018: 29 · 2017: 40 · 2016: 23 · 2015: 23 · 2014: 36 · 2013: 42 · 2012: 24
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, bone mechanical properties, vertebral bone, femoral neck, proximal tibia, bone mineral density, elastic modulus, yield stress, structure-function relationship
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Bone and Bones, Female, Femur, Femur Neck, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Models, Anatomic, Spine, Tensile Strength, Tibia, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.