Dependence of yield strain of human trabecular bone on anatomic site
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Understanding the dependence of human trabecular bone strength behavior on anatomic site provides insight into structure-function relationships and is essential to the increased success of site-specific finite element models of whole bones. To investigate the hypothesis that the yield strains of human trabecular bone depend on anatomic site, the uniaxial tensile and compressive yield properties were compared for cylindrical specimens from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27) taken from 61 donors (67+/-15years). Test protocols were used that minimized end artifacts and loaded specimens along the main trabecular orientation. Yield strains by site (mean+/-S.D.) ranged from 0.70+/-0.05% for the trochanter to 0.85+/-0.10% for the femoral neck in compression, from 0.61+/-0.05% for the trochanter to 0.70+/-0.05% for the vertebra in tension, and were always higher in compression than tension (p<0.001). The compressive yield strain was higher for the femoral neck than for all other sites (p<0.001), as was the tensile yield strain for the vertebra (p<0.007). Analysis of covariance, with apparent density as the covariate, indicated that inter-site differences existed in yield stress even after adjusting statistically for density (p<0.035). Coefficients of variation in yield strain within each site ranged from only 5-12%, consistent with the strong linear correlations (r(2)=0.94-0.98) found between yield stress and modulus. These results establish that the yield strains of human trabecular bone can differ across sites, but that yield strain may be considered uniform within a given site despite substantial variation in elastic modulus and yield stress.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The volume fraction of trabecular bone varies from 60% in primary compressive group of femoral neck to less than 10% in the elderly spine (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
9 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718 · cited 1×
“Through advancements in imaging techniques and computational methods, it is now possible to create detailed anatomic site-specific finite element models of trabecular bone specimens (Kabel et al., 1999; Ulrich et al., 1999; Zysset et al., 1998) and whole bones (Keyak and Rossi, 2000; Lotz et al.”
MethodPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“, 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 6×
“Uniaxial compressive and tensile mechanical tests were conducted at room temperature using a servohydraulic load frame (858 Mini-Bionix, MTS, Eden Prairie, MN) following protocols designed to minimize end artifacts (Keaveny et al., 1994a; Kopperdahl and Keaveny, 1998).”
BackgroundMethodResultSelf-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 1×
“, 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al., 1997; Mosekilde et al., 1987) render the strength behavior of human trabecular bone of primary medical importance.”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432 · cited 1×
“The central role of trabecular bone in the etiology of whole bone fractures (Lotz and Hayes 1990; McBroom et al., 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al.”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431 · cited 1×
“tension) in yield strains across all anatomic sites supports previous suggestions of a similarity in the yield strains between trabecular and cortical tissue (Keaveny, 1997; Niebur et al., 2000).”
ResultSelf-citationCiarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401 · cited 3×
“(1988) reported single ultimate stress–density regressions for data pooled from multiple sites, while subsequent studies reported that the regression coefficients did depend on site (Ciarelli et al., 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultSystematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377 · cited 4×
“However, strain measurements obtained in this manner can result in a loss of precision due to the effect of sampling at one location on the irregular specimen surface rather than across the entire crosssection and gage length (Keaveny et al., 1997).”
BackgroundMethodSelf-citationMajumdar, S., Kothari, M., Augat, P., Newitt, D. C., Link, T. M., Lin, J. C., Lang, T., Lu, Y., & Genant, H. K. (1998) · Bone · doi:10.1016/s8756-3282(98)00030-1 · Cited by 331 · cited 1×
“The dependence of the degree of anisotropy on anatomic site (Ciarelli et al., 1991; Majumdar et al., 1998) hinders inter-site comparisons of mechanical properties unless all specimens are tested in the principal material coordinate system (‘‘on-axis’’).”
BackgroundKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationFracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90053-1 · Cited by 300
Self-citationMechanical Property Distributions in the Cancellous Bone of the Human Proximal Femur
Brown, T. D., & Ferguson, A. B. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990819 · Cited by 282 · cited 1×
“Brown and Ferguson (1980) found a strong linear correlation between yield stress and modulus for specimens taken from different regions of the proximal femur.”
BackgroundKeyak, J. H., & Rossi, S. A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00152-9 · Cited by 250
The use of quantitative computed tomography to estimate risk of fracture of the hip from falls.
Lotz, J. C., & Hayes, W. C. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072050-00008 · Cited by 243 · cited 1×
“The central role of trabecular bone in the etiology of whole bone fractures (Lotz and Hayes 1990; McBroom et al., 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al.”
BackgroundThe underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225 · cited 2×
“Although the end artifacts produced in the traditional platens testing protocol produce artificially high values of yield strain (Keaveny et al., 1993; Odgaard and Linde, 1991), modification of this protocol to include a small extensometer attached directly to the specimen surface, away from the ends of the specimen,…”
BackgroundMcCALDEN, R. W., McGEOUGH, J. A., & COURT-BROWN, C. M. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199703000-00016 · Cited by 221
Kabel, J., van Rietbergen, B., Odgaard, A., & Huiskes, R. (1999) · Bone · doi:10.1016/s8756-3282(99)00190-8 · Cited by 206
Van Rietbergen, B., Müller, R., Ulrich, D., Rüegsegger, P., & Huiskes, R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00150-x · Cited by 170
Silva, M. J., Keaveny, T. M., & Hayes, W. C. (1998) · Journal of Orthopaedic Research · doi:10.1002/jor.1100160305 · Cited by 143 · cited 2×
“For example, such results would eliminate the need for the strength–density mappings, commonly used to determine regions of failure in whole bone finite element analyses (Keyak and Rossi, 2000; Lotz et al., 1991; Silva et al., 1998).”
BackgroundSelf-citationTheoretical analysis of the experimental artifact in trabecular bone compressive modulus
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90021-6 · Cited by 136 · cited 2×
“, 1993; Odgaard and Linde, 1991), modification of this protocol to include a small extensometer attached directly to the specimen surface, away from the ends of the specimen, minimizes these artifacts (Keaveny et al., 1993).”
BackgroundSelf-citationYield Behavior of Bovine Cancellous Bone
Turner, C. H. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168375 · Cited by 127 · cited 3×
“Experiments on bovine tibial bone indicate that yield strains are independent of density (Keaveny et al., 1994b; Turner, 1989) and are isotropic (Chang et al.”
BackgroundInfluentialFyhrie, D. P., & Vashishth, D. (2000) · Bone · doi:10.1016/s8756-3282(99)00246-x · Cited by 120
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895413 · Cited by 115
Micro-compression: a novel technique for the nondestructive assessment of local bone failure
Müller, R., Gerber, S. C., & Hayes, W. C. (1998) · Technology and Health Care · doi:10.3233/thc-1998-65-616 · Cited by 112
Nonlinear Behavior of Trabecular Bone at Small Strains
Morgan, E. F., Yeh, O. C., Chang, W. C., & Keaveny, T. M. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1338122 · Cited by 107 · cited 1×
“2% strain (Morgan et al., 2001), and the yield point was determined by the 0.”
BackgroundSelf-citationA Global Relationship Between Trabecular Bone Morphology and Homogenized Elastic Properties
Zysset, P. K., Goulet, R. W., & Hollister, S. J. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834756 · Cited by 105 · cited 1×
“Through advancements in imaging techniques and computational methods, it is now possible to create detailed anatomic site-specific finite element models of trabecular bone specimens (Kabel et al., 1999; Ulrich et al., 1999; Zysset et al., 1998) and whole bones (Keyak and Rossi, 2000; Lotz et al.”
MethodFenech, C. M., & Keaveny, T. M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798339 · Cited by 81
Self-citationUniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170418 · Cited by 77
Self-citationBeck, J. D., Canfield, B. L., Haddock, S. M., Chen, T. J., Kothari, M., & Keaveny, T. M. (1997) · Bone · doi:10.1016/s8756-3282(97)00122-1 · Cited by 58 · cited 1×
“We quantified the degree of misalignment in the specimens used in this study by performing mean intercept length calculations on three-dimensional reconstructions obtained either via serial grinding (Beck et al., 1997) or micro-computed tomography (Scanco mCT 20; Scanco Medical, Bassersdorf, Switzerland).”
MethodSelf-citationErrors Induced by Off-Axis Measurement of the Elastic Properties of Bone
Turner, C. H., & Cowin, S. C. (1988) · Journal of Biomechanical Engineering · doi:10.1115/1.3108433 · Cited by 56
Mechanistic Approaches to Analysis of Trabecular Bone
Keaveny, P. D. T. M. (1998) · Forma · Cited by 39
Research works printed but not linked: 1
- Niebur, G.L., Keaveny, T.M., 2001. Trabecular bone exhibits multiple failure surfaces in biaxial loading. Transactions on Orthopaedic Research Society 26.
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
“Previously published protocols were used to obtain 8mm diameter on-axis specimens from the human vertebra, proximal tibia, and proximal femur (Kopperdahl and Keaveny, 1998; Morgan and Keaveny, 2001).”
MethodSelf-citationComparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Self-citationBone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
InfluentialSelf-citationBiomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
“, 1994), and can vary between sites (Kopperdahl and Keaveny, 1998; Morgan and Keaveny, 2001).”
BackgroundBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Metadata
- Authors
- Morgan, E. F., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Morgan, Elise F
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 34
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2073813406
- Cited by
- 705
- References
- 37
- Citations by year
- 2026: 30 · 2025: 30 · 2024: 42 · 2023: 27 · 2022: 39 · 2021: 44 · 2020: 50 · 2019: 31 · 2018: 29 · 2017: 40 · 2016: 23 · 2015: 23 · 2014: 36 · 2013: 42 · 2012: 24
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, bone mechanical properties, vertebral bone, femoral neck, proximal tibia, bone mineral density, elastic modulus, yield stress, structure-function relationship
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Bone and Bones, Female, Femur, Femur Neck, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Models, Anatomic, Spine, Tensile Strength, Tibia, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.