Dependence of yield strain of human trabecular bone on anatomic site
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Understanding the dependence of human trabecular bone strength behavior on anatomic site provides insight into structure-function relationships and is essential to the increased success of site-specific finite element models of whole bones. To investigate the hypothesis that the yield strains of human trabecular bone depend on anatomic site, the uniaxial tensile and compressive yield properties were compared for cylindrical specimens from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27) taken from 61 donors (67+/-15years). Test protocols were used that minimized end artifacts and loaded specimens along the main trabecular orientation. Yield strains by site (mean+/-S.D.) ranged from 0.70+/-0.05% for the trochanter to 0.85+/-0.10% for the femoral neck in compression, from 0.61+/-0.05% for the trochanter to 0.70+/-0.05% for the vertebra in tension, and were always higher in compression than tension (p<0.001). The compressive yield strain was higher for the femoral neck than for all other sites (p<0.001), as was the tensile yield strain for the vertebra (p<0.007). Analysis of covariance, with apparent density as the covariate, indicated that inter-site differences existed in yield stress even after adjusting statistically for density (p<0.035). Coefficients of variation in yield strain within each site ranged from only 5-12%, consistent with the strong linear correlations (r(2)=0.94-0.98) found between yield stress and modulus. These results establish that the yield strains of human trabecular bone can differ across sites, but that yield strain may be considered uniform within a given site despite substantial variation in elastic modulus and yield stress.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The volume fraction of trabecular bone varies from 60% in primary compressive group of femoral neck to less than 10% in the elderly spine (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [82]
9 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718 · cited 1×
“Through advancements in imaging techniques and computational methods, it is now possible to create detailed anatomic site-specific finite element models of trabecular bone specimens (Kabel et al., 1999; Ulrich et al., 1999; Zysset et al., 1998) and whole bones (Keyak and Rossi, 2000; Lotz et al.”
MethodPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“, 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 6×
“Uniaxial compressive and tensile mechanical tests were conducted at room temperature using a servohydraulic load frame (858 Mini-Bionix, MTS, Eden Prairie, MN) following protocols designed to minimize end artifacts (Keaveny et al., 1994a; Kopperdahl and Keaveny, 1998).”
BackgroundMethodResultSelf-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 1×
“, 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al., 1997; Mosekilde et al., 1987) render the strength behavior of human trabecular bone of primary medical importance.”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432 · cited 1×
“The central role of trabecular bone in the etiology of whole bone fractures (Lotz and Hayes 1990; McBroom et al., 1985) and its pronounced reduction in strength with osteopenia and aging (McCalden et al.”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431 · cited 1×
“tension) in yield strains across all anatomic sites supports previous suggestions of a similarity in the yield strains between trabecular and cortical tissue (Keaveny, 1997; Niebur et al., 2000).”
ResultSelf-citation
Research works printed but not linked: 1
- Niebur, G.L., Keaveny, T.M., 2001. Trabecular bone exhibits multiple failure surfaces in biaxial loading. Transactions on Orthopaedic Research Society 26.
Cited by
Items 501–600 of 732
Assessment of hip fracture risk by cross-sectional strain-energy derived from image-based beam model
Luo, Y., & Yang, H. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.02.016 · Cited by 5
Bennison, M. B. L., Pilkey, A. K., & Lievers, W. B. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047679 · Cited by 5
Biomechanical Behavior Characterization and Constitutive Models of Porcine Trabecular Tibiae
Quintana-Barcia, C., Rodríguez, C., Álvarez, G., & Maestro, A. (2021) · Biology · doi:10.3390/biology10060532 · Cited by 5
“Furthermore, mechanical properties of this material are affected by many factors such as anatomic localization [7,10,11], the bone stress state, its mineral density [6], sex, age [9,12], and, of course, the patient’s health.”
BackgroundKusins, J. R., Knowles, N. K., Targosinski, J., Columbus, M. P., Athwal, G. S., & Ferreira, L. M. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104922 · Cited by 5
The effects of force application on the compressive properties of femoral spongious bone
Metzner, F., Fischer, B., Heyde, C.-E., & Schleifenbaum, S. (2022) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2022.105866 · Cited by 5
Skedros, J. G., Cronin, J. T., Dayton, M. R., Bloebaum, R. D., & Bachus, K. N. (2023) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2023.111495 · Cited by 5
Analyse des propriétés biomécaniques de l'os à l'échelle macroscopique
Beaupied, H., Lespessailles, É., & Benhamou, C.-L. (2007) · Revue du Rhumatisme · doi:10.1016/j.rhum.2007.02.001 · Cited by 9
Zhang, M., Gao, J., Huang, X., Gong, H., Zhang, M., & Liu, B. (2017) · Journal of Healthcare Engineering · doi:10.1155/2017/5707568 · Cited by 5
“2 times of its yield stress [17, 32], and the ultimate strain of all vertebral materials was set as 0.”
BackgroundEstimating the strength of bone using linear response
Gunaratne, G. H. (2002) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.66.061904 · Cited by 6
Development and Validation of an Analogue Lumbar Spine Model and its Integral Components
Domann, J. P. (2011) · KU ScholarWorks (The University of Kansas) · Cited by 9
Roger, R., Ghosh, R., Cai, Y., Gibson, F. G., Lazáry, Á., Guo, L., Lacroix, D., & Dall’Ara, E. (2026) · Scientific Reports · doi:10.1038/s41598-026-46900-4 · Cited by 4
“(3), σ y1 represents the isotropic von Mises yield criterion used to model bone plasticity, based on a density-strength relationship 34 .”
Reimeringer, M., & Nuño, N. (2014) · Advances in Biomechanics and Applications · doi:10.12989/aba.2014.1.3.187 · Cited by 6
Poudrel, A.-S., Bouffandeau, A., Rosi, G., Dubory, A., Flouzat–Lachaniette, C.-H., Nguyen, V., & Haïat, G. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108405 · Cited by 4
Jiang, C., Ouyang, H., Li, Y., Lang, N., Zhang, Y., Jiang, L., & Yuan, H. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1542352 · Cited by 4
Stefanek, P., Silva-Henao, J. D., Fiedler, V., Reisinger, A., Pahr, D. H., & Synek, A. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1524235 · Cited by 4
“Since Morgan and Keaveny (2001) showed that yield strains remain relatively constant across species, damage onset strains in tension and compression were taken from Stipsitz et al. (2020), Stipsitz et al. (2021) and kept constant (damage onset strain in tension ε + 0.0068; damage onset strain in…”
InfluentialChen, L., Wang, X., Kröber, M., Abdelmonem, E., & Wan, X. (2025) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-025-09065-1 · Cited by 5
“The strain induced by the titanium alloy VBR on the endplates was higher than that of PEEK VBR, but all values were below the vertebral fatigue strain threshold (7000 µε ± 600 µε) reported by Morgan and Keaveny [52].”
Perilli, E., Baleani, M., Raatjes, W., Baruffaldi, F., Cappello, A., & Toni, A. (2005) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519405001473 · Cited by 4
Biomaterials: Joints and problems of contact interfaces
Rakin, M., & Sedmak, A. (2006) · TechnoRep (University of Belgrade – Faculty of Technology and Metallurgy) · Cited by 4
Danesi, V., Faldini, C., & Cristofolini, L. (2017) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519417300022 · Cited by 5
Numerical Analyses of Fracture Mechanism of the Pelvic Ring during Side-Impact Load
Klekiel, T., Arkusz, K., Sławiński, G., Malesa, P., & Będziński, R. (2022) · Materials · doi:10.3390/ma15165734 · Cited by 4
“7% [14] and the ultimate compressive strain as 1.”
BackgroundInfluentialMajcher, K. B., Kontulainen, S., Leswick, D. A., Dolovich, A., & Johnston, J. D. (2024) · Scientific Reports · doi:10.1038/s41598-024-57768-7 · Cited by 1
Saviour, C. M., & Gupta, S. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104159 · Cited by 4
Targosinski, J., Kusins, J. R., Athwal, G. S., Nelson, A. J., & Ferreira, L. M. (2024) · Journal of Orthopaedic Research® · doi:10.1002/jor.25976 · Cited by 4
Computational modelling of bone microstructure
Lü, Y. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819531-4.00011-0 · Cited by 4
Amin, T., Lin, H. C., Parr, W. C., Lim, P., & Mobbs, R. J. (2021) · World Neurosurgery · doi:10.1016/j.wneu.2021.04.013 · Cited by 4
Kahla, R. B., & Barkaoui, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-88467-9.00005-9 · Cited by 6
Haider, I. T., Sawatsky, A., Zhu, Y., Page, R., Kostenuik, P. J., Boyd, S. K., & Edwards, W. B. (2022) · Bone · doi:10.1016/j.bone.2022.116517 · Cited by 4
Lin, A., Boyd, G., Varela, A., & Guldberg, R. E. (2017) · Molecular and integrative toxicology · doi:10.1007/978-3-319-56192-9_7 · Cited by 4
Fan, R., Liu, J., Jia, Z., Deng, Y., & Liu, J. (2017) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411917743275 · Cited by 4
Chen, Y.-N., Chang, C.-W., Chang, C., Chung, C.-R., Li, C., & Peng, Y.-T. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.03.012 · Cited by 4
Sima, G., Cincă, I., Teișanu, C., & Gîngu, O. (2015) · Advanced materials research · doi:10.4028/www.scientific.net/amr.1128.162 · Cited by 3
Quintiens, J., Morren, T., Coudyzer, W., & van Lenthe, H. (2025) · Bone · doi:10.1016/j.bone.2025.117683 · Cited by 3
3D printed biomimetic PEEK/HA scaffolds induce cranial bone regeneration
Li, H., Liao, L., Jia, Y., Zhang, Y., Zhang, K., Zhang, X., Zhu, X., & Yuan, B. (2026) · Journal of Materials Chemistry B · doi:10.1039/d5tb02807h · Cited by 4
Zhu, Z., Yang, Y., Li, L., Zhu, S. J., & Zhang, L. (2024) · PLoS ONE · doi:10.1371/journal.pone.0299996 · Cited by 3
“Thus, in this study, the mechanical failure criterion for trabecular bone was determined using a compressive yielding strain of 0.85 ± 0.10% [50].”
BackgroundMethodInfluentialRaccoons Reveal Hidden Diversity in Trabecular Bone Development
Reinecke, T. E., & Angielczyk, K. D. (2024) · Integrative Organismal Biology · doi:10.1093/iob/obae038 · Cited by 3
NATALI, A. N., Carniel, E. L., & Pavan, P. G. (2009) · Journal of Adhesion Science and Technology · doi:10.1163/156856109x432712 · Cited by 3
Previous Damage Accumulation Can Influence Femoral Fracture Strength: A Finite Element Study
Haider, I. T., & Frei, H. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24383 · Cited by 3
Biomecánica de la interfaz hueso-tornillo en instrumentación transpedicular de columna
Alpízar-Aguirre, A., Carbonell, R. A. G., Ortiz, A., & Jacobo, V. H. (2022) · Acta Ortopédica Mexicana · doi:10.35366/109693 · Cited by 3
Hybrid additive manufacturing for Zn-Mg casting for biomedical application
Shahed, K. S., Fainor, M., Gullbrand, S. E., Hast, M. W., & Manogharan, G. P. (2024) · In vitro models · doi:10.1007/s44164-024-00077-0 · Cited by 3
“Young’s modulus of human bones ranges from 0.01 to 30 GPa [97, 98] which is lower when compared to Young’s modulus of Fe implant materials.”
InfluentialBone Density and Mechanical Property
Luo, Y. (2017) · Springer eBooks · doi:10.1007/978-3-319-51671-4_4 · Cited by 3
Mechanical Behavior of Trabecular Bone
Mostakhdemin, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804634-0.00003-3 · Cited by 3
Qu, A., Wang, D., Zeng, X., & Wang, Q. (2018) · Bio-Medical Materials and Engineering · doi:10.3233/bme-181005 · Cited by 3
“By comparison, strain has been proved to be more accurate in predicting pelvic fractures [26,28–30].”
Experimental validation of finite elements model in hip fracture and its clinical applicability
Larrainzar‐Garijo, R., Caeiro, J. R., Marco, M., Giner, E., & Miguélez, M. H. (2019) · Revista Española de Cirugía Ortopédica y Traumatología · doi:10.1016/j.recote.2018.05.004 · Cited by 3
Prediction of failure in cancellous bone using extended finite element method
Salem, M., Westover, L., Adeeb, S., & Duke, K. (2020) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411920936057 · Cited by 3
“5 cm(3)) is smaller than the size of specimens in the reported experiments, which often range between 5 and 10mm.(38,68,69) Also, the results were obtained from one specimen and should be extended to several larger specimens from various anatomical locations.”
BackgroundMICROSTRUCTURAL STRESSES AND STRAINS ASSOCIATED WITH TRABECULAR BONE MICRODAMAGE
Nagaraja, S. (2006) · UPT. Syiah Kuala University Library (Syiah Kuala University) · Cited by 4
Kreipke, T. C., & Niebur, G. L. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1835-3 · Cited by 3
Mechanical and morphometric characterization of cancellous bone
González, R. B. (2020) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/149376 · Cited by 3
“4 Nanoindentation - FE 622 ± 302 Compression Human Trochanter Wet [45] 597 ± 330 Tension 344 ± 148 Compression Human Vertebra Wet [45] 349 ± 133 Tension 99 ± 38.”
BackgroundMethodResultInfluentialGoda, I. (2015) · theses.fr (ABES) · doi:10.70675/99c63103z26cfz4591za136zb8b043c6d73c · Cited by 4
Finite element modelling of screw fixation in augmented and non-augmented cancellous bone
Kamane, P. B. (2012) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 3
Almendros-Abellán, V. M., Castro‐García, M., Canales‐Vázquez, J., Berenguel-Herraiz, P., & Sabater, S. (2021) · Bone · doi:10.1016/j.bone.2021.115865 · Cited by 2
Yu, Y., Robinson, D. L., Ackland, D. C., & Lee, P. V. S. (2025) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-025-06248-3 · Cited by 2
“Strain distributions from the model were computed and quantified according to the cortical area and trabecular volume exceeding yield thresholds (maximum principal strain > 0.007 or minimum principal strain < -0.0077) defined by Morgan and Keaveny [58].”
InfluentialReinke, A., Ward, G., Feldman, J., Whiteside, E., Burey, P. P., & Windus, L. C. E. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae3f6a · Cited by 2
“These values are markedly lower than published tissue benchmarks for vertebral tensile strength (1.72 ± 0.64 MPa) and trabecular femoral bone strength (10.93 ± 3.08 MPa) [44], highlighting the mechanical gap between current scaffolds and native bone (figure 4(b)).”
InfluentialYang, G., Xiong, Y., Fan, L., Zhang, S., Li, H., Wu, G., Ding, X., Song, Q., & Yao, J. (2026) · Journal of Laser Applications · doi:10.2351/7.0002037 · Cited by 2
Papadakis, L., Avraam, S., Mancisidor, A. M., Loizou, A., Evangelou, A., Kyratsi, T., & Photiou, D. (2026) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-026-17661-1 · Cited by 2
Optimization of 3D printing parameters for PLGA/HA scaffolds using the Taguchi method
Gautam, K., Jimenez, H. G., Dikici, Y., Bensusan, J. S., Wnek, G. E., Rimnac, C. M., & Akkuş, O. (2026) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2026.107385 · Cited by 2
Tetteh, A. E., Smith, J. A., Porter, D. A., Prima, M. A. D., & Kurtz, S. M. (2026) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.70053 · Cited by 2
Fatigue performance of additively manufactured porous titanium for orthopaedic applications
Leinwand, J., Lam, R., Patel, S. R., McGregor, M. E., McLachlin, S. D., & Vlasea, M. (2026) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2026.107393 · Cited by 3
A review of macro-damage models used in finite element modelling of bone fracture
Mohammadi, H., Eichwalder, J., Ghaffari, D., Ferreira, L. M., & Knowles, N. K. (2026) · Modelling and Simulation in Materials Science and Engineering · doi:10.1088/1361-651x/ae65b2 · Cited by 2
“[29], G IIC / G IC = G IIIC / G IC = 0.33 [21], ε c = 0.061 [77] Giambini et al [157] L3 vertebrae NR E = 1890 ρ 1.92 (for 0 ρ 0.22), E = 3050 ρ 1.81 (for 0.22 ⩾ ρ ), v = 0.4, [70, 76] Minimum normal principal strain against yield strain (Abaqus) ε y = 0.0065 ρ − 1 .”
InfluentialGhosh, R., Shearman, E., Roger, R., Palanca, M., Dall’Ara, E., & Lacroix, D. (2026) · Bone · doi:10.1016/j.bone.2026.117961 · Cited by 2
An Experimental Study on the Mode I Fracture Behavior of Hexagonal Honeycombs
Uddin, M. S., Ju, J., & D’Souza, N. A. (2013) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2013-64914 · Cited by 2
Bone Quality Assessment Using High Resolution Peripheral Quantitative Computed Tomography (HR-pQCT)
Zhou, B. (2015) · doi:10.7916/d81z43hg · Cited by 2
Gandhi, H. S. (2022) · INTERNATIONAL JOURNAL OF COMPUTERS & TECHNOLOGY · doi:10.24297/ijct.v22i.9288 · Cited by 3
Marchenko, E. S., Shishelova, A. A., Baigonakova, G. A., Polyakov, N. A., & Botryakova, I. G. (2023) · Physica Scripta · doi:10.1088/1402-4896/ad15ce · Cited by 2
Nazari, A. R. (2024) · Orthopedic Research Online Journal · doi:10.31031/oproj.2024.10.000750 · Cited by 2
Towards Bio-Mimetic 3D Printable Human Anatomies
Forni, R., Calderonel, D., Coato, D., Dolino, G., Cesarelli, G., Ricciardi, C., Cesarelli, M., & Gargiulo, P. (2024) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine62247.2024.10795909 · Cited by 4
Hounsfield units as a tool for the evaluation of bone demineralization due to exoprosthesis use
Patiño, J. F. R., Isaza, J. A., Mariaka, I., & Zea, J. A. V. (2013) · Revista Facultad de Ingeniería Universidad de Antioquia · doi:10.17533/udea.redin.15232 · Cited by 2
Prygoski, M. P., Caballero, S. S., Schmid, S. R., Lozier, A. J., & Cantó, M. Á. S. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4024641 · Cited by 2
Ding, H. D., Zhu, Z.-A., Dai, K., Ye, M., & Wang, C. (2008) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-008-0623-5 · Cited by 2
“Other studies reported that residual strains and changes in modulus are observed at apparent strains that are less than half of the apparent compressive yield strain [ 26 ] , which supports the idea that damage contributes to the nonlinearity of the stress strain curve at small strains [23] . Finally, in Figs.”
BackgroundJanuddi, F., Syahrom, A., Harun, M. N., Rabiatul, A. A. R., Jaafar, A., & Afriwardi, A. (2013) · Advanced materials research · doi:10.4028/www.scientific.net/amr.845.266 · Cited by 2
“Differences of elastic modulus across anatomic sites is especially higher in proximal femur owing to its density which give it the higher strength [19] than in other anatomic sites.”
BackgroundAnalysis of an early intervention distal femoral resurfacing implant for medial osteoarthritis
Chaudhary, M. E., & Walker, P. S. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.09.039 · Cited by 2
Bioinert Polymers (Polyetheretherketone)
Goharian, A., Abdullah, M. R., & Kadir, M. R. A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804634-0.00009-4 · Cited by 2
Fang, Z., Ranslow, A. N., Tomas-Medina, P. D., Gunnarsson, A., Weerasooriya, T., Satapathy, S., Thompson, K. A., & Kraft, R. H. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4039895 · Cited by 2
Medicine and the Virtual Physiological Human
Martelli, S., Al‐Dirini, R. M. A., & Jan, S. V. S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816713-7.00043-x · Cited by 2
Composite materials for hip joint prostheses
Santis, R. D., Gloria, A., & Ambrosio, L. (2010) · Elsevier eBooks · doi:10.1533/9781845697372.2.276 · Cited by 2
Cole, J. H., & van der Meulen, M. C. H. (2020) · Contemporary Endocrinology · doi:10.1007/978-3-319-69287-6_10 · Cited by 2
The mechanical behavior of bone
Karim, L., Hussein, A. I., Vaidya, R., Morgan, E. F., & Bouxsein, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813073-5.00013-7 · Cited by 4
Self-citationZhang, Y., Zhang, T., Ge, X., Ma, Y., Cui, Z., Wu, S., Liang, Y., Zhu, S., & Li, Z. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/2330472 · Cited by 2
“Postyield modulus (MPa) Epy = 0:05 × 757 × ρ1:94 Morgan and Keaveny [22]”
BackgroundMethodInfluentialRetractedTargosinski, J., Kusins, J. R., Martensson, N., Nelson, A. J., Knowles, N. K., & Ferreira, L. M. (2022) · Lecture notes in computational vision and biomechanics · doi:10.1007/978-3-031-10015-4_16 · Cited by 2
Hautamäki, M. (2012) · UTUPub (University of Turku) · Cited by 4
Fabrication of bioactive glass scaffolds by stereolithography for bone tissue engineering
Sabree, I. K. (2014) · Research Explorer (The University of Manchester) · Cited by 4
Finite Element Analysis of Bone and Experimental Validation
Almeida, F. M. P., & Completo, A. (2020) · Lecture notes in computational vision and biomechanics · doi:10.1007/978-3-030-37541-6_7 · Cited by 1
Sacher, S. E., Hernandez, C. J., & Donnelly, E. L. (2021) · Advanced Engineering Materials · doi:10.1002/adem.202100206 · Cited by 1
Multiscale Porous Poly (Ether-Ether-Ketone) Structures Manufactured by Powder Bed Fusion Process
Liu, Y., Davies, R., Yi, N., McCutchion, P., Chen, B., & Ghita, O. (2022) · 3D Printing and Additive Manufacturing · doi:10.1089/3dp.2021.0317 · Cited by 1
Lozhkomoev, A. S., Казанцев, С. О., Bakina, O. V., Буяков, А. С., Senkina, E. I., Krinitcyn, M., Ivanyuk, V. A., Sharipova, A. F., & Лернер, М. И. (2024) · Inorganic Materials Applied Research · doi:10.1134/s207511332470028x · Cited by 1
“…samples of Fe/PLA is slightly lower than the yield strength of the scaffolds with the porosity of 62.3% and significantly exceeds the yield strength of the scaffolds with the porosity of 82.3% made of pure Fe obtained in [13], and it also corresponds to the parameters of a spongy bone [43].”
InfluentialAbar, B. M., Goonewardene, H., Sheng, R., Negus, M. H., Allen, N. B., Kelly, C. N., Stinson, N. C., Becker, M. L., Thaden, J. T., Adams, S. B., et al. (2025) · Frontiers in Biomaterials Science · doi:10.3389/fbiom.2025.1394166 · Cited by 1
Theoretical Considerations for Patient-Specific Modeling Based on Observable State Variables
Ateshian, G. A., Deiters, S., & Weiss, J. A. (2025) · Journal of Biomechanical Engineering · doi:10.1115/1.4069924 · Cited by 1
Murashko, A. M., Filippov, Y. Y., Larionov, D. S., Garshev, A. V., Prosvirnin, D. V., Evdokimov, P. V., & Putlyaev, V. I. (2025) · Russian Metallurgy (Metally) · doi:10.1134/s0036029526700060 · Cited by 1
“Important mechanical properties of bioceramics include compressive strength, fracture toughness, and Young’s modulus [9–11].”
Pretty, S. P., Mourtzakis, M., & Laing, A. C. (2025) · Journal of Biomechanical Engineering · doi:10.1115/1.4070502 · Cited by 1
Chen, D., Yang, Z.-P., Wang, X., Lyu, K., Ma, K., Lai, Q., He, J., Ma, Y., & Zhang, Z. (2026) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.70152 · Cited by 1
“The behavior of cancellous bone was also scrutinized using strain strength based on the mech-anostat hypothesis [40] and principal strains (compression and tension limits) [41].”
Boudjemaa, I., Khatir, O., Benkhettou, A., Sahli, A., & Yaylacı, M. (2026) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2026.2647113 · Cited by 1
Yang, X., Yang, X., Guo, Z., Li, Q., Mi, C., & Sun, Z. (2026) · Thin-Walled Structures · doi:10.1016/j.tws.2026.115118 · Cited by 1
Sabahi, N., Roohani, I., Kilian, K. A., Wang, C. H., & Li, X. (2026) · Biofabrication · doi:10.1088/1758-5090/ae8a85 · Cited by 1
“Considering the modulus of human trabecular bone, which typically ranges between 10 and 3000 MPa [48, 49], our developed scaffolds showed promising results.”
Model simulation of novel spine for the motion stress analysis with muscle stimulation
IWAMI, T., MIYAWAKI, K., Ishikawa, Y., Matsunaga, T., Shimada, Y., & Obinata, G. (2008) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs.2008.4752492 · Cited by 1
A method for vibrational assessment of cortical bone
Song, Y., & Gunaratne, G. H. (2006) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.2213246 · Cited by 1
Evaluation on mechanical properties of a single trabecular in bovine femur
Enoki, S., Higashiura, M., Sato, M., Tanaka, K., & KATAYAMA, T. (2012) · WIT transactions on the built environment · doi:10.2495/hpsm120061 · Cited by 1
Prygoski, M. P., Pasang, T., Schmid, S. R., & Lozier, A. J. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4461-x · Cited by 1
Tissue Response to Mechanical Load in Dental Implants
Saxena, S. (2015) · International journal of oral and maxillofacial pathology · Cited by 1
Comportamiento biomecánico de tejido óseo en fijaciones de columna
Alpízar-Aguirre, A., Ortiz-Prado, A., Morales-Acosta, L., Ruiz-Cervantes, O., Carbonell, R. A. G., & Jacobo, V. H. (2020) · Cirugía y Cirujanos · doi:10.24875/ciru.19000928 · Cited by 1
Viscoelastic Mechanical Behavior of Fresh Human Bone of Lower Limbs
Benhmida, S., Salhi, D., Zrida, M., Hamzaoui, A. H., & Essaddam, H. (2020) · Lecture notes in mechanical engineering · doi:10.1007/978-3-030-52071-7_50 · Cited by 1
Metadata
- Authors
- Morgan, E. F., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Morgan, Elise F
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 34
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2073813406
- Cited by
- 705
- References
- 37
- Citations by year
- 2026: 30 · 2025: 30 · 2024: 42 · 2023: 27 · 2022: 39 · 2021: 44 · 2020: 50 · 2019: 31 · 2018: 29 · 2017: 40 · 2016: 23 · 2015: 23 · 2014: 36 · 2013: 42 · 2012: 24
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, bone mechanical properties, vertebral bone, femoral neck, proximal tibia, bone mineral density, elastic modulus, yield stress, structure-function relationship
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Bone and Bones, Female, Femur, Femur Neck, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Models, Anatomic, Spine, Tensile Strength, Tibia, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.