Trabecular bone modulus–density relationships depend on anatomic site
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
One outstanding issue regarding the relationship between elastic modulus and density for trabecular bone is whether the relationship depends on anatomic site. To address this, on-axis elastic moduli and apparent densities were measured for 142 specimens of human trabecular bone from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27). Specimens were obtained from 61 cadavers (mean+/-SD age=67+/-15 years). Experimental protocols were used that minimized end-artifact errors and controlled for specimen orientation. Tissue moduli were computed for a subset of 18 specimens using high-resolution linear finite element analyses and also using two previously developed theoretical relationships (Bone 25 (1999) 481; J. Elasticity 53 (1999) 125). Resultant power law regressions between modulus and density did depend on anatomic site, as determined via an analysis of covariance. The inter-site differences were among the leading coefficients (p<0.02), but not the exponents (p>0.08), which ranged 1.49-2.18. At a given density, specimens from the tibia had higher moduli than those from the vertebra (p=0.01) and femoral neck (p=0.002); those from the trochanter had higher moduli than the vertebra (p=0.02). These differences could be as large as almost 50%, and errors in predicted values of modulus increased by up to 65% when site-dependence was ignored. These results indicate that there is no universal modulus-density relationship for on-axis loading. Tissue moduli computed using methods that account for inter-site architectural variations did not differ across site (p>0.15), suggesting that the site-specificity in apparent modulus-density relationships may be attributed to differences in architecture.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Items 201–300 of 1,000
Christen, D., Melton, L. J., Zwahlen, A., Amin, S., Khosla, S., & Müller, R. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1996 · Cited by 53
“2, support1⁄4 2) was first converted to apparent density (rapp) according to the measurement calibration record (18) and, second, to a local elastic modulus (E) using the relation by Morgan and colleagues((19)) for the femoral neck, EðrappÞ 1⁄4 6850 rapp.”
MethodResultWeisse, B., Aiyangar, A. K., Affolter, C., Gander, R., Terrasi, G. P., & Ploeg, H. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.04.002 · Cited by 47
Computational analysis of primary implant stability in trabecular bone
Steiner, J. A., Ferguson, S. J., & van Lenthe, H. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.008 · Cited by 58
“…developed (Taddei et al., 2004; Taylor et al., 2002; Zannoni et al., 1998) and experimentally validated (Gupta et al., 2004; Taddei et al., 2007) for various bone types demonstrating that different relationships exist for different anatomical locations (Helgason et al., 2008; Morgan et al., 2003).”
BackgroundNonlinear viscoelastic characterization of bovine trabecular bone
Manda, K., Wallace, R. J., Xie, S., Levrero-Florencio, F., & Pankaj, P. (2016) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-016-0809-y · Cited by 49
“The density of this cellular solid has been related to its time-independent elastic stiffness in a number of studies (Currey 1986; Morgan et al. 2003), and these relations are frequently used in computational models of bone and bone-implant systems (Goffin et al. 2013).”
BackgroundCosta, M., Éltes, P., Lazáry, Á., Varga, P., Viceconti, M., & Dall'ara, E. (2019) · Journal of The Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2019.06.027 · Cited by 46
“, 2008) and then to the elastic modulus [Eq (2)] (Morgan et al., 2003) (Bonemat software, Bologna, Italy).”
BackgroundMethodMultiscale modelling of the skeleton for the prediction of the risk of fracture
Viceconti, M., Taddei, F., Jan, S. V. S., Leardini, A., Cristofolini, L., Stea, S., Baruffaldi, F., & Baleani, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.01.009 · Cited by 55
Quantifying Leisure Physical Activity and Its Relation to Bone Density and Strength
SHEDD, K. M., HANSON, K. B., ALEKEL, D. L., SCHIFERL, D. J., HANSON, L. N., & VAN LOAN, M. D. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318155a7fe · Cited by 47
“Physical activity assessment—Physical activity during the past 12 months was assessed using a modified Paffenbarger Physical Activity Questionnaire (15), which assesses frequency, duration, and aerobic intensity of usual physical activity.”
BackgroundMethodInfluentialReduction in Proximal Femoral Strength in Patients With Acute Spinal Cord Injury
Edwards, W. B., Schnitzer, T. J., & Troy, K. L. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2227 · Cited by 50
“Elements were assigned nonlinear and inhomogeneous isotropic material properties using an empirical density‐elasticity relationship specific to the femoral neck:((20))”
MethodGrassi, L., Väänänen, S. P., Ristinmaa, M., Jurvelin, J. S., & Isaksson, H. (2016) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-016-0866-2 · Cited by 58
Jung, C.-H., Cha, Y., Yoon, H. S., Park, C. H., Yoo, J.-I., Kim, J.-T., & Jeon, Y. (2022) · Bone and Joint Research · doi:10.1302/2046-3758.112.bjr-2021-0282.r1 · Cited by 46
Li, J.-C., Xie, T., Zhang, Z., Song, Z.-T., Song, Y., & Zeng, J. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.862951 · Cited by 45
Li, Z., Chen, Z., Chen, D., & Zhao, R. (2024) · Composite Structures · doi:10.1016/j.compstruct.2024.117923 · Cited by 50
Ariza, O., Gilchrist, S. E., Widmer, R. P., Guy, P., Ferguson, S. J., Cripton, P. A., & Helgason, B. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.11.042 · Cited by 53
Vetter, A., Witt, F., Sander, O., Duda, G. N., & Weinkamer, R. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0299-x · Cited by 45
“For the exponent κ , the value 1.83 was used (Morgan et al. 2003).”
MethodInfluentialLoss of trabeculae by mechano-biological means may explain rapid bone loss in osteoporosis
Mulvihill, B. M., McNamara, L. M., & Prendergast, P. J. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2007.1341 · Cited by 50
Fleps, I., Pálsson, H., Baker, A. M., Enns-Bray, W. S., Bahaloo, H., Danner, M., Singh, N. B., Taylor, W. R., Sigurdsson, S. O., Gudnason, V. G., et al. (2021) · Bone · doi:10.1016/j.bone.2021.116219 · Cited by 52
Li, Z., Chen, Z., Chen, D., & Zhao, R. (2023) · Composite Structures · doi:10.1016/j.compstruct.2023.117638 · Cited by 44
Mechanical characterization of injection-molded macro porous bioceramic bone scaffolds
Vivanco, J. F., Aiyangar, A. K., Araneda, A., & Ploeg, H. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.02.003 · Cited by 44
Eberle, S., Göttlinger, M., & Augat, P. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.06.035 · Cited by 52
Mapping anisotropy of the proximal femur for enhanced image based finite element analysis
Enns-Bray, W. S., Owoc, J. S., Nishiyama, K. K., & Boyd, S. K. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.020 · Cited by 52
Varga, P., Grünwald, L., Inzana, J. A., & Windolf, M. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.07.004 · Cited by 48
Permeability study of cancellous bone and its idealised structures
Syahrom, A., Kadir, M. R. A., Harun, M. N., & Öchsner, A. Ö. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.11.001 · Cited by 47
Shedd-Wise, K. M., Alekel, D. L., Hofmann, H., Hanson, K. B., Schiferl, D. J., Hanson, L. N., & Loan, M. D. V. (2011) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2010.11.003 · Cited by 43
“88) (20), which is a material property (21).”
Butz, K. D., Merrell, G. A., & Nauman, E. A. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.517525 · Cited by 43
“The thickness of the cartilage layer on each side of the joint was taken as 2 mm and was modelled with contact constraints between the cartilage and bone (Goligher et al. 2006) using material properties used for each tissue summarised in Table 1 (Guo 2001; Morgan et al. 2003; Jin and Lewis 2004).”
MethodFleps, I., Enns-Bray, W. S., Guy, P., Ferguson, S. J., Cripton, P. A., & Helgason, B. (2018) · PLoS ONE · doi:10.1371/journal.pone.0200952 · Cited by 45
Mishra, R., Basu, B., & Kumar, A. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-009-3814-1 · Cited by 43
“ing a broad picture of human trabecular bone elastic behavior [ 20 ].”
BackgroundDesign and manufacturing of patient-specific Ti6Al4V implants with inhomogeneous porosity
Rana, M., Karmakar, S. K., Bandyopadhyay, A. K., & Chowdhury, A. R. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.105925 · Cited by 42
ZADPOOR, A. A., & Weinans, H. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.018 · Cited by 50
“The relationships between bone density and elasticity modulus are shown to be dependent on the anatomical site (Morgan et al., 2003; Morgan and Keaveny, 2001).”
Tuncer, M., Hansen, U. N., & Amis, A. A. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.04.006 · Cited by 49
Strain shielding inspired re‐design of proximal femoral stems for total hip arthroplasty
Cilla, M., Checa, S., & Duda, G. N. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23540 · Cited by 42
“The heterogeneous properties of the bone were defined by mapping the BMD of each bone element to its elastic modulus following Morgan et al.,32 E ¼ 6:850 rapp1:49 ð1Þ where E is the Young’s modulus of the bone in GPa and rapp represents the apparent density of the bone measured in g/cm3.”
ResultInfluentialWu, Y., Chen, C.-H., Tsuang, F.-Y., Lin, Y., Chiang, C.-J., & Kuo, Y. (2019) · PLoS ONE · doi:10.1371/journal.pone.0211676 · Cited by 46
On the Road to Personalized Medicine: Multiscale Computational Modeling of Bone Tissue
Podshivalov, L., Fischer, A., & Bar‐Yoseph, P. (2014) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9120-1 · Cited by 46
Blanchard, R., Morin, C., Malandrino, A., Vella, A., Sant, Z., & Hellmich, C. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2760 · Cited by 46
Linear viscoelasticity - bone volume fraction relationships of bovine trabecular bone
Manda, K., Xie, S., Wallace, R. J., Levrero-Florencio, F., & Pankaj, P. (2016) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-016-0787-0 · Cited by 41
“Linear timeindependent elasticity has been themost commonmodel used for trabecular bone though some studies suggest that some nonlinearity in trabecular bone is initiated even at small strain levels (Morgan et al. 2001).”
BackgroundAl‐Dirini, R. M. A., Huff, D. N., Ju, Z., Besier, T. F., Clement, J. G., & Taylor, M. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23744 · Cited by 44
Torres-Sánchez, C., McLaughlin, J., & Fotticchia, A. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.10.026 · Cited by 42
“These results are in agreement with other studies on porous scaffolds [14, 44] and on bone specimens [28, 45].”
BackgroundResultReeves, J. M., Langohr, G. D. G., Athwal, G. S., & Johnson, J. A. (2018) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2018.06.002 · Cited by 44
Material properties of human lumbar intervertebral discs across strain rates
Newell, N., Carpanen, D., Grigoriadis, G., Little, J. P., & Masouros, S. D. (2019) · The Spine Journal · doi:10.1016/j.spinee.2019.07.012 · Cited by 41
Kadir, M. R. A., Syahrom, A., & Öchsner, A. Ö. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0593-2 · Cited by 45
Comparison of patellar bone strain in the natural and implanted knee during simulated deep flexion
Fitzpatrick, C. K., Baldwin, M. A., Ali, A. A., Laz, P. J., & Rullkoetter, P. J. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21211 · Cited by 40
Measurement of Bone: Diagnosis of SCI-Induced Osteoporosis and Fracture Risk Prediction
Troy, K. L., & Morse, L. R. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2104-267 · Cited by 43
A new finite element based parameter to predict bone fracture
Colombo, C., Libonati, F., Rinaudo, L., Bellazzi, M., Ulivieri, F. M., & Vergani, L. M. (2019) · PLoS ONE · doi:10.1371/journal.pone.0225905 · Cited by 43
Bone cement as a local chemotherapeutic drug delivery carrier in orthopedic oncology: A review
Phull, S. S., Yazdi, A. R., Ghert, M. A., & Towler, M. R. (2020) · Journal of bone oncology · doi:10.1016/j.jbo.2020.100345 · Cited by 40
Shi, C., Lu, N., Qin, Y., Liu, M., Li, H., & Li, H. (2021) · PLoS ONE · doi:10.1371/journal.pone.0247764 · Cited by 40
“DP ¼ PPlane A PPlane B ð5Þ https://doi.org/10.1371/journal.pone.0247764.g005 PLOS ONE | https://doi.org/10.1371/journal.pone.0247764 March 4, 2021 7 / 17 K ¼ m � n � L DP ð6Þ Where K is the permeability coefficient (mm2); L is the characteristic length (mm); ΔP is the pressure difference (MPa).”
BackgroundInfluentialHazrati, J., Ito, K., & van Rietbergen, B. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.08.022 · Cited by 44
Bah, M. T., Nair, P. B., & Browne, M. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.08.001 · Cited by 39
Developing CT based computational models of pediatric femurs
Li, X., Viceconti, M., Cohen, M. C., Reilly, G. C., Carré, M., & Offiah, A. C. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.03.027 · Cited by 45
“…(Schileo et al., 2008a): ρash ¼ 0:8772 ρCTþ0:07895 ð2Þ ρapp ¼ 1 0:6 ρash ð3Þ The Young's modulus (E) was then estimated based on the following relationship proposed by Morgan et al. (2003): E¼ 6850ρ1:49app ¼ 14664ρ1:49ash ð4Þ Finite element meshes of the femurs consisting of 10-node tetrahedra…”
Varga, P., Schwiedrzik, J. J., Zysset, P. K., Hofmann‐Fliri, L., Widmer, D., Gueorguiev, B. G., Blauth, M., & Windolf, M. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.11.026 · Cited by 41
Pellikaan, P., Giarmatzis, G., Sloten, J. V., Verschueren, S., & Jonkers, I. (2018) · PLoS ONE · doi:10.1371/journal.pone.0195463 · Cited by 49
Implant–bone interface healing and adaptation in resurfacing hip replacement
Dickinson, A., Taylor, A., & Browne, M. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.567269 · Cited by 39
“Then, a Young’s modulus (E) value was assigned to each element according to its density (r) using the relationship E ¼ 6850 r 1.49 (Morgan et al. 2003).”
MethodInfluentialLópez, A., Mestres, G., Ott, M. K., Engqvist, H., Ferguson, S. J., Persson, C., & Helgason, B. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.01.002 · Cited by 38
Goda, I., Rahouadj, R., & Ganghoffer, J. (2013) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2013.06.013 · Cited by 40
Micromechanics of the human vertebral body for forward flexion
Yang, H., Nawathe, S., Fields, A. J., & Keaveny, T. M. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.05.044 · Cited by 42
“The choice of 8 MPa was based on the compressive stress-strain curve at J Biomech.”
BackgroundInfluentialSelf-citationRyan, T. M., Raichlen, D. A., & Gosman, J. H. (2017) · Cambridge University Press eBooks · doi:10.1017/9781316388907.013 · Cited by 39
Image-based finite-element modeling of the human femur
Falcinelli, C., & Whyne, C. M. (2020) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2020.1789863 · Cited by 44
Ulivieri, F. M., & Rinaudo, L. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11092284 · Cited by 39
Syahrom, A., Kadir, M. R. A., Abdullah, J. B., & Öchsner, A. Ö. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0833-0 · Cited by 38
First clinical and biomechanical results of the Trochanteric Fixation Nail (TFN)
Lenich, A., Fierlbeck, J., Al-Munajjed, A. A., Dendorfer, S., Mai, R., Füchtmeier, B., Mayr, E. J., & Hammer, J. (2006) · Technology and Health Care · doi:10.3233/thc-2006-144-521 · Cited by 38
“The bone mineral density of the specimens showed with 357 ± 63 mg/cm 3 only about half of the typical range reported in literature 670 ± 15 mg/cm 3 [9].”
Giambini, H., Qin, X., Dragomir‐Daescu, D., An, K., & Nassr, A. N. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1348-x · Cited by 37
Garijo, N., Martínez, J. M., García‐Aznar, J. M., & Pérez, M. Á. (2013) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2013.10.005 · Cited by 42
Patient-specific finite element modeling for femoral bone augmentation
Basafa, E., Armiger, R. S., Kutzer, M. D. M., Belkoff, S. M., Mears, S. C., & Armand, M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.01.003 · Cited by 37
Numerical modelling of hip fracture patterns in human femur
Marco, M., Giner, E., Caeiro-Rey, J. R., Miguélez, M. H., & Larrainzar‐Garijo, R. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.03.010 · Cited by 39
Individualized prediction of pedicle screw fixation strength with a finite element model
Widmer, J., Fasser, M., Croci, E., Spirig, J. M., Snedeker, J. G., & Farshad, M. (2020) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2019.1709173 · Cited by 37
“We tested four different power law functions relating bone density to the Young’s modulus, as published by Keller (1994), Goulet et al. (1994), Keyak et al. (1997) and Morgan et al. (2003) (Figure 3(A)) (Goulet et al. 1994; Keller 1994; Keyak et al. 1997; Morgan et al. 2003).”
MethodZhu, L., Liang, H., Lv, F., Xie, D., Wang, C., Mao, Y., Yang, Y., Tian, Z., & Shen, L. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01392 · Cited by 38
Zhang, S., Feng, Z., Hu, Y. Y., Zhao, D., Guo, X., Du, F., Wang, N., Sun, C., Liu, C., & Liu, H. (2021) · Small · doi:10.1002/smll.202105589 · Cited by 38
Prediction of the mechanical response of the femur with uncertain elastic properties
Wille, H., Rank, E., & Yosibash, Z. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.02.006 · Cited by 45
“Patient-specific finite element (FE) analyses for predicting the mechanical response of human femurs are performed by many researchers nowadays (Bessho et al., 2007; Helgason et al., 2008b; Keyak et al., 1993; Schileo et al., 2008; Trabelsi et al., 2009; Yosibash et al., 2007b).”
BackgroundMethodInfluentialEffect of bone inhomogeneity on tibiofemoral contact mechanics during physiological loading
Venäläinen, M. S., Mononen, M. E., Väänänen, S. P., Jurvelin, J. S., Töyräs, J., Virén, T., & Korhonen, R. K. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.02.033 · Cited by 37
Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs
Levadnyi, I., Awrejcewicz, J., Gubaua, J. E., & Pereira, J. T. (2017) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2017.10.015 · Cited by 39
Enns-Bray, W. S., Bahaloo, H., Fleps, I., Pauchard, Y., Taghizadeh, E., Sigurdsson, S. O., Aspelund, T., Büchler, P., Harris, T. B., Gudnason, V. G., et al. (2018) · Bone · doi:10.1016/j.bone.2018.09.014 · Cited by 42
Biomechanical mechanisms of orbital wall fractures – A transient finite element analysis
Schaller, A., Huempfner-Hierl, H., Hemprich, A., & Hierl, T. (2012) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2012.02.008 · Cited by 36
Prevalence of Poor Bone Quality in Women Undergoing Spinal Fusion Using Biomechanical-CT Analysis
Burch, S., Feldstein, M., Hoffmann, P., & Keaveny, T. M. (2015) · Spine · doi:10.1097/brs.0000000000001175 · Cited by 38
Self-citationDolomite-Foamed Bioactive Silicate Scaffolds for Bone Tissue Repair
Fiume, E., Tulyaganov, D. U., Ubertalli, G., Verné, E., & Baino, F. (2020) · Materials · doi:10.3390/ma13030628 · Cited by 36
“Higher sintering temperatures, in fact, might cause an excessive increase in the density of the structure, which would become too high as compared to the reference range of human trabecular bone [50] reported in Table 2.”
Cortical bone mapping improves finite element strain prediction accuracy at the proximal femur
Schileo, E., Pitocchi, J., Falcinelli, C., & Taddei, F. (2020) · Bone · doi:10.1016/j.bone.2020.115348 · Cited by 35
Schwarzenberg, P., Klein, K., Ferguson, S. J., von Rechenberg, B., Darwiche, S., & Dailey, H. L. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24866 · Cited by 36
“First, a direct conversion from HU to elastic modulus was achieved using a linear scaling law.18 For the two power law material assignments, the native HU density measure of the CT scan was first converted to calibrated mineral density (ρQCT) using the phantom and then to ash ρ( )+ 90mg/cmQCT 3 and apparent density ρ(…”
InfluentialBioactivity and Bone Cell Formation with Poly-ε-Caprolactone/Bioceramic 3D Porous Scaffolds
Juan, P.-K., Fan, F.-Y., Lin, W., Liao, P.-B., Huang, C., Shen, Y., Ruslin, M., & Lee, C.-H. (2021) · Polymers · doi:10.3390/polym13162718 · Cited by 43
“The improved hydrophilic properties were achieved by the high specific area of the NPs [14,53,57,60].”
BackgroundLee, C.-Y., Chan, S., Lai, H.-Y., & Lee, S. (2011) · Journal of Neurosurgery Spine · doi:10.3171/2010.12.spine10453 · Cited by 35
Nie, Y., Ma, J., Huang, Z., Xu, B., Tang, S., Shen, B., Kraus, V. B., & Pei, F. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.12.004 · Cited by 35
“Morgan EF, Bayraktar HH, Keaveny TM, 2003 Trabecular bone modulus-density relationships depend on anatomic site.”
MethodSu, Y., Wang, X., Ren, D., Liu, Y., Liu, S., & Wang, P. (2018) · Medicine · doi:10.1097/md.0000000000012046 · Cited by 35
Kluess, D., Soodmand, E., Lorenz, A., Pahr, D. H., Schwarze, M., Cichon, R., Varady, P. A., Herrmann, S., Buchmeier, B., Schröder, C., et al. (2019) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2019.1615481 · Cited by 38
Gustafsson, A., Tognini, M., Bengtsson, F., Gasser, T. C., Isaksson, H., & Grassi, L. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104118 · Cited by 36
Tilton, M., Borjali, A., Isaacson, A. C., Varadarajan, K. M., & Manogharan, G. P. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.109498 · Cited by 39
Sensale, M., Vendeuvre, T., Schilling, C., Grupp, T. M., Rochette, M., & Dall’Ara, E. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.643154 · Cited by 35
QCT/FEA predictions of femoral stiffness are strongly affected by boundary condition modeling
Rossman, T., Kushvaha, V., & Dragomir‐Daescu, D. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2015.1006209 · Cited by 35
“Isotropic, linear elastic bone material properties (Figure 1, Step 5) were assigned to each FE using a power law relationship between bone ash density (g cm(23)) and elastic modulus ðE;MPaÞ : E 1⁄4 14664r ash (Morgan et al. 2003; Dragomir-Daescu et al. 2011).”
MethodGong, H., Zhang, M., Qin, L., & Hou, Y. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9332-8 · Cited by 39
Simulation of vertebral trabecular bone loss using voxel finite element analysis
Donnell, P. M., Harrison, N. M., Liebschner, M. A. K., & McHugh, P. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.07.038 · Cited by 37
Schaller, A., Voigt, C., Huempfner-Hierl, H., Hemprich, A., & Hierl, T. (2011) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2011.09.004 · Cited by 34
“The Hounsfield units were converted into Young’s modulus based on the approach of MORGAN et al.14.”
MethodKim, D., Navalgund, A. R., Tee, B. C., Noble, G. J., Hart, R. T., & Lee, H. R. (2012) · Bone · doi:10.1016/j.bone.2012.08.124 · Cited by 35
“Bone mineral density (BMD) and architecture have been widely examined to help estimate the mechanical properties of bone [19].”
BackgroundInorganic/Organic Biocomposite Cryogels for Regeneration of Bony Tissues
Mishra, R., & Kumar, A. (2011) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/092050610x534230 · Cited by 34
Enns-Bray, W. S., Ariza, O., Gilchrist, S. E., Widmer, R. P., Vogt, P. J., Pálsson, H., Boyd, S. K., Guy, P., Cripton, P. A., Ferguson, S. J., et al. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.08.010 · Cited by 40
Terzini, M., Aldieri, A., Rinaudo, L., Osella, G., Audenino, A. L., & Bignardi, C. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00220 · Cited by 37
González, F. J. Q., Steineman, B. D., Sturnick, D. R., Deland, J. T., Demetracopoulos, C. A., & Wright, T. M. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24876 · Cited by 35
“The Hounsfield units (HUs) from the preoperative CT scans were linearly related to the bone's apparent density by assuming that the minimum HU of each bone corresponded to an apparent density of 0 g/cc, while the maximum HU corresponded to a density of 1.8 g/cc.14 We related the apparent density to elastic modulus by…”
MethodInfluentialPrado, M., Khosla, S., Chaput, C. D., & Giambini, H. (2021) · European Radiology · doi:10.1007/s00330-021-08071-w · Cited by 35
Guha, I., Zhang, X., Rajapakse, C. S., Chang, G. A., & Saha, P. K. (2022) · Medical Physics · doi:10.1002/mp.15629 · Cited by 44
Lenaerts, L., & van Lenthe, H. (2009) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0302 · Cited by 41
“Morgan et al. (2003) investigated whether site specificity exists in the density–elasticity relationships.”
BackgroundForell, G. A. V., Stephens, T. K., Samartzis, D., & Bowden, A. E. (2015) · Spine · doi:10.1097/brs.0000000000000982 · Cited by 34
Giambini, H., Dragomir‐Daescu, D., Nassr, A. N., Yaszemski, M. J., & Zhao, C. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4034172 · Cited by 34
Gupta, A. K., Bayraktar, H. H., Fox, J. C., Keaveny, T. M., & Papadopoulos, P. (2006) · Computational Mechanics · doi:10.1007/s00466-006-0082-5 · Cited by 32
“The primary elastic modulus (E1, in MPa) was assigned to each element using apparent density-modulus relationship determined from the on-axis mechanical tests of trabecular bone cores from the greater trochanter and femoral neck [7, 26 ] as E1 = � c1ρ α1 , for ρ ≤ 0.32g/cm 3 ,”
MethodResultSelf-citationKok, J., Širka, A., Grassi, L., Raina, D. B., Tarasevičius, Š., Tägil, M., Lidgren, L., & Isaksson, H. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.03.008 · Cited by 33
Winsor, C., Li, X., Qasim, M., Henak, C. R., Pickhardt, P. J., Ploeg, H., & Viceconti, M. (2020) · Bone · doi:10.1016/j.bone.2020.115759 · Cited by 39
“In addition to being specific to the phantom’s reference material, these relationships are also specific to anatomic site, in this case the femur [56].”
BackgroundRobo, C., Öhman‐Mägi, C., & Persson, C. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104437 · Cited by 33
“…et al., 2015; L ´ opez et al., 2014; Robo et al., 2021; Telera et al., 2018; Bornemann et al., 2016; Mauri et al., 2018), in the range of that of the cancellous bone in the vertebral body (10 – 900 MPa) (Morgan et al., 2003; Nazarian et al., 2008; Hel-gason et al., 2008; Crawford et al., 2003).”
Background
Metadata
- Authors
- Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 36
- Issue
- 7
- Pages
- 897-904
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2088873760
- Cited by
- 1,209
- References
- 49
- Citations by year
- 2026: 73 · 2025: 72 · 2024: 79 · 2023: 71 · 2022: 78 · 2021: 99 · 2020: 85 · 2019: 59 · 2018: 56 · 2017: 55 · 2016: 61 · 2015: 55 · 2014: 62 · 2013: 43 · 2012: 37
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, elastic modulus, bone mineral density, bone structure, finite element analysis, vertebrae, proximal tibia, femoral neck, power-law regression, bone mechanical properties
- MeSH terms
- Aged, Bone and Bones, Cadaver, Computer Simulation, Elasticity, Female, Femur, Femur Neck, Humans, Lumbar Vertebrae, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Thoracic Vertebrae, Tibia, Reproducibility of Results, Bone Density, Anisotropy, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.