Trabecular bone modulus–density relationships depend on anatomic site
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
One outstanding issue regarding the relationship between elastic modulus and density for trabecular bone is whether the relationship depends on anatomic site. To address this, on-axis elastic moduli and apparent densities were measured for 142 specimens of human trabecular bone from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27). Specimens were obtained from 61 cadavers (mean+/-SD age=67+/-15 years). Experimental protocols were used that minimized end-artifact errors and controlled for specimen orientation. Tissue moduli were computed for a subset of 18 specimens using high-resolution linear finite element analyses and also using two previously developed theoretical relationships (Bone 25 (1999) 481; J. Elasticity 53 (1999) 125). Resultant power law regressions between modulus and density did depend on anatomic site, as determined via an analysis of covariance. The inter-site differences were among the leading coefficients (p<0.02), but not the exponents (p>0.08), which ranged 1.49-2.18. At a given density, specimens from the tibia had higher moduli than those from the vertebra (p=0.01) and femoral neck (p=0.002); those from the trochanter had higher moduli than the vertebra (p=0.02). These differences could be as large as almost 50%, and errors in predicted values of modulus increased by up to 65% when site-dependence was ignored. These results indicate that there is no universal modulus-density relationship for on-axis loading. Tissue moduli computed using methods that account for inter-site architectural variations did not differ across site (p>0.15), suggesting that the site-specificity in apparent modulus-density relationships may be attributed to differences in architecture.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Items 301–400 of 1,000
Li, J., Yang, Z., Xie, T., Song, Z.-T., Song, Y., & Zeng, J. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.922848 · Cited by 33
Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength
Haider, I. T., Speirs, A., & Frei, H. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.004 · Cited by 36
Pal, B., & Gupta, S. (2011) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411910397102 · Cited by 33
A Genetic Algorithm Based Multi-Objective Shape Optimization Scheme for Cementless Femoral Implant
Chanda, S., Gupta, S., & Pratihar, D. K. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029061 · Cited by 32
Primary and long-term stability of a short-stem hip implant
Dabirrahmani, D., Hogg, M., Kohan, L., & Gillies, M. (2010) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim704 · Cited by 36
Femoral strain during walking predicted with muscle forces from static and dynamic optimization
Edwards, W. B., Miller, R. H., & Derrick, T. R. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.03.007 · Cited by 42
“Muscle excitation timings for larger muscles were constrained to be similar to normative human electromyogram timing (Sutherland, 2001).”
BackgroundMethodInfluentialYazdanpanah, Z., Sharma, N. K., Raquin, A., Cooper, D. M. L., Chen, D., & Johnston, J. D. (2023) · BioMedical Engineering OnLine · doi:10.1186/s12938-023-01135-6 · Cited by 37
Nasiri, M., & Luo, Y. (2016) · Bone · doi:10.1016/j.bone.2016.06.006 · Cited by 38
“Then, isotropic inhomogeneousmaterial properties were derived from vBMD using the empirical equations of Morgan and colleagues [67,68]:”
MethodLuo, Y., Jiang, Y., Zhu, J., Tu, J., & Jiao, S. (2020) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2020.09.076 · Cited by 32
Luo, Y., Wang, M., Tu, J., Jiang, Y., & Jiao, S. (2021) · International Journal of Minerals Metallurgy and Materials · doi:10.1007/s12613-020-2212-z · Cited by 32
Structure‐function relationships of the human vertebral endplate
Wu, Y., Loaiza, J., Banerji, R., Blouin, O., & Morgan, E. F. (2021) · JOR Spine · doi:10.1002/jsp2.1170 · Cited by 40
Self-citationBiomechanical and clinical studies on lumbar spine fusion surgery: a review
Pradeep, K., & Pal, B. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02750-6 · Cited by 32
A new meshless approach for subject-specific strain prediction in long bones: Evaluation of accuracy
Taddei, F., Pani, M., Zovatto, L., Tonti, E., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.06.009 · Cited by 32
“The relationship between ash density and Young’s modulus was derived from the literature (Morgan et al., 2003):”
MethodContribution of muscular weakness to osteoporosis: Computational and animal models
Be'ery-Lipperman, M., & Gefen, A. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.05.018 · Cited by 34
“3 and S1), which is reflected in the experimental findings of Morgan et al. (2003).”
BackgroundMethodInfluentialAustman, R. L., Milner, J. S., Holdsworth, D. W., & Dunning, C. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim553 · Cited by 34
Lievers, W. B., Poljsak, A. S., Waldman, S. D., & Pilkey, A. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.06.001 · Cited by 35
Trabecular Bone Contributes to Strength of the Proximal Femur Under Mediolateral Impact in the Avian
Passi, N., & Gefen, A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1835366 · Cited by 38
Pandithevan, P., & Kumar, G. S. (2009) · Virtual and Physical Prototyping · doi:10.1080/17452750903055512 · Cited by 34
“…in deriving Young’s modulus of the cortical bone as: Ebc 0:53(pc=100) 21:43 (in GPa) (R 2 0:66) (3) The relationship between Young’s modulus and trabecular bone density for the human femoral bone has been investigated by many researchers (Rho et al. 1995, Rice et al. 1998, Morgan et al. 2003).”
BackgroundXu, Y., Huang, G., Li, T., Tan, Y., & Bao, T. (2022) · Materials Science and Engineering A · doi:10.1016/j.msea.2022.144265 · Cited by 31
Fabric dependence of quasi-waves in anisotropic porous media
Cardoso, L., & Cowin, S. C. (2011) · The Journal of the Acoustical Society of America · doi:10.1121/1.3557032 · Cited by 33
Mechanical characterization of a novel gradient thinning triangular honeycomb
Han, J., Chen, H., Xu, X., Li, Z., Chen, Q., Gu, Z., & Gu, Z. (2023) · Thin-Walled Structures · doi:10.1016/j.tws.2023.110862 · Cited by 31
Biomechanics of Musculoskeletal System and Its Biomimetic Implications: A Review
Ren, L., Qian, Z., & Ren, L. (2014) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(14)60033-0 · Cited by 39
Creep of trabecular bone from the human proximal tibia
Novitskaya, E. E., Zin, C., Chang, N., Cory, E., Chen, P., DʼLima, D. D., Sah, R. L., & McKittrick, J. M. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.03.057 · Cited by 31
“Creep in bone is a complex phenomenon and varies with type of loading and local mechanical properties [19,24,25].”
BackgroundBonaretti, S., Seiler, C., Boichon, C., Reyes, M., & Büchler, P. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.09.006 · Cited by 31
Voronoi as the optimal approach for strut-based bone scaffold design
Deng, T., Li, M., Gong, S., Chen, P., Wang, J., Zhang, H., Wang, B., Wu, Z., Li, K., & Nie, Y. (2025) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2025.110124 · Cited by 32
Gustafson, H. M., Cripton, P. A., Ferguson, S. J., & Helgason, B. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.10.002 · Cited by 30
Mesgar, A. S.-M., Mohammadi, Z., & Khosrovan, S. (2017) · International Journal of Polymeric Materials · doi:10.1080/00914037.2017.1320663 · Cited by 32
Yang, S., Leslie, W. D., Luo, Y., Goertzen, A. L., Ahmed, S., Ward, L. M., Delubac, I., & Lix, L. M. (2017) · Osteoporosis International · doi:10.1007/s00198-017-4232-8 · Cited by 32
Aldieri, A., Terzini, M., Osella, G., Priola, A. M., Angeli, A., Veltri, A., Audenino, A. L., & Bignardi, C. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4040586 · Cited by 34
Groenen, K. H. J., Bitter, T., van Veluwen, T. C. G., van der Linden, Y. M., Verdonschot, N. J. J., Tanck, E., & Janssen, D. W. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.24117 · Cited by 34
“and Morgan et al.(24,25) resulted in overpredictions of the experimental measurements, whereas models based on Ouyang et al.”
BackgroundMethodChatterjee, S., Roy, S., Majumder, S., & Roychowdhury, A. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4046973 · Cited by 30
Persson, C., Robert, E., Carlsson, E., Robo, C., López, A., Godoy‐Gallardo, M., Ginebra, M., & Engqvist, H. (2015) · Journal of Biomaterials Applications · doi:10.1177/0885328215581316 · Cited by 30
A REVIEW OF FINITE ELEMENT APPLICATIONS IN ORAL AND MAXILLOFACIAL BIOMECHANICS
Doğru, S. C., Cansız, E., & Arslan, Y. Z. (2018) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519418300028 · Cited by 30
A biomechanical sorting of clinical risk factors affecting osteoporotic hip fracture
Luo, Y. (2015) · Osteoporosis International · doi:10.1007/s00198-015-3316-6 · Cited by 37
Response of Human Skull Bone to Dynamic Compressive Loading
Boruah, S., Henderson, K. A., Subit, D. L., Salzar, R. S., Shender, B. S., & Paskoff, G. R. (2013) · Cited by 32
Mechanical performance of cementless total knee replacements: It is not all about the maximum loads
González, F. J. Q., Lipman, J. D., Lo, D., Martino, I. D., Sculco, P. K., Sculco, T. P., Catani, F., & Wright, T. M. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.24194 · Cited by 29
“The apparent density was then converted to elastic modulus by combining the empirical relationships from Morgan et al.(24) and Snyder and Schneider,(25) which have been shown to adequately predict bone failure under daily activities and to correlate well with experimental data.”
MethodInfluentialMa, S., Wang, Z., Guo, Y. Q., Wang, P., Yang, Z., Han, L., Sun, J., & Xia, Y. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s185122 · Cited by 29
“In this study, the elastic modulus of the interface with α FeNPs assemblies was increased (Figure 4A and B), and more similar to that of human cancellous bone than ES control, 49 which bodes well for osteoinduction.”
ResultAltai, Z., Montefiori, E., van Veen, B., Paggiosi, M., McCloskey, E. V., Viceconti, M., Mazzà, C., & Li, X. (2021) · PLoS ONE · doi:10.1371/journal.pone.0245121 · Cited by 31
Multiscale Modeling of the Skeletal System
Viceconti, M. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9781139049627 · Cited by 42
Effect of Nucleus Replacement Device Properties on Lumbar Spine Mechanics
Rundell, S. A., Guerin, H. L., Auerbach, J. D., & Kurtz, S. M. (2009) · Spine · doi:10.1097/brs.0b013e3181af1d5a · Cited by 30
“The quantitative relationship between BMD and elastic modulus in cancellous vertebral bone, as reported by Morgan et al and Ulrich et al, was used to define a nonlinear relationship between BMD and orthotropic elastic modulus.(31,32) Elastic moduli within the vertebral body fell within what has been previously reporte…”
MethodVetter, A., Liu, Y., Witt, F., Manjubala, I., Sander, O., Epari, D. R., Fratzl, P., Duda, G. N., & Weinkamer, R. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.09.009 · Cited by 42
Mulvihill, B. M., & Prendergast, P. J. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.01.006 · Cited by 35
“As a finite element can be a combination of both bone and non-bone during simulated remodelling, a quadratic relationship is assumed to exist between the elastic modulus and the apparent density of bone (Morgan et al., 2003) as follows:”
BackgroundAnderson, D., & Madigan, M. L. (2013) · Journal of Applied Biomechanics · doi:10.1123/jab.29.5.505 · Cited by 30
Lee, D. C., Varela, A., Kostenuik, P. J., Ominsky, M. S., & Keaveny, T. M. (2016) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2830 · Cited by 31
Self-citationZeinali, A., Hashemi, B., & Akhlaghpoor, S. (2009) · Physica Medica · doi:10.1016/j.ejmp.2009.08.002 · Cited by 31
Taddei, F., Palmadori, I., Taylor, W. R., Heller, M. O. W., Bordini, B., Toni, A., & Schileo, E. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.030 · Cited by 34
“ship for proximal femur specimens (Morgan et al., 2003).”
Rundell, S. A., Day, J. S., Isaza, J., Guillory, S., & Kurtz, S. M. (2011) · Spine · doi:10.1097/brs.0b013e318241e415 · Cited by 30
Nazemi, S. M., Cooper, D. M. L., & Johnston, J. D. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.06.011 · Cited by 34
Influence of Geometry and Depth of Resections on Bone Support for Total Ankle Replacement
Bischoff, J. E., Schon, L. C., & Saltzman, C. L. (2017) · Foot & Ankle International · doi:10.1177/1071100717712508 · Cited by 29
“Various studies have shown a power relationship between HU and mechanical properties (including stiffness and strength) of bone, ~ HU n ( ) , though there is significant variability in the value of n based on the anatomic location and/ or study design.(4,15,16,20) Here, values of n ranging from 1 to 3 were considered,…”
BackgroundRobinson, D. L., Safai, L., Harandi, V. J., Graf, M., Lizama, L. E. C., Lee, P. V. S., Galea, M. P., Khan, F., Tse, K. M., & Ackland, D. C. (2020) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2020.01.017 · Cited by 30
DXA-Based Bone Strain Index: A New Tool to Evaluate Bone Quality in Primary Hyperparathyroidism
Tabacco, G., Naciu, A. M., Messina, C., Sanson, G., Rinaudo, L., Cesareo, R., Falcone, S., Manfrini, S., Napoli, N., Bilezikian, J. P., et al. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab317 · Cited by 28
“In both spine and femur, stiffness of the elements was defined by the empirical relations described by Morgan et al (26), at each anatomic site.”
MethodNie, Y., Yu, Q., & Shen, B. (2021) · Orthopaedic Surgery · doi:10.1111/os.12927 · Cited by 28
Ulivieri, F. M., Rinaudo, L., Messina, C., Piodi, L. P., Capra, D., Lupi, B., Meneguzzo, C., Sconfienza, L. M., Sardanelli, F., Giustina, A., et al. (2021) · European Radiology Experimental · doi:10.1186/s41747-021-00242-0 · Cited by 29
Bone: A Composite Natural Material
Fatima, M., Canhão, H. M., & Eurico, J. (2011) · InTech eBooks · doi:10.5772/17523 · Cited by 37
“…compression of trabecular bone, using vertebrae (Ammann & Rizzoli, 2003; Kopperdahl & Keaveny, 1998; Matsuura et al., 2008; Morgan & Keaveny, 2001; Morgan et al., 2003; Silva, 2007; Woo et al., 2010), tibia (Fonseca & Ward, 2004; Morgan & Keaveny, 2001; Morgan et al., 2003), femur (Cory et al.,…”
BackgroundInfluentialAmini, M., Nazemi, S. M., Lanovaz, J. L., Kontulainen, S. A., Masri, B. A., Wilson, D. R., Szyszkowski, W., & Johnston, J. D. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.05.011 · Cited by 34
Yamako, G., Chosa, E., Zhao, X., Totoribe, K., Watanabe, S., Sakamoto, T., & Nakane, N. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.02.018 · Cited by 28
Comprehensive evaluation of PCA-based finite element modelling of the human femur
Grassi, L., Schileo, E., Boichon, C., Viceconti, M., & Taddei, F. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.06.021 · Cited by 28
Kourtis, L. C., Carter, D. R. P., Kesari, H., & Beaupré, G. S. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840801930728 · Cited by 31
“To determine this, the same load case (T 1⁄4 Mx 1⁄4 1Nm) was applied to the cross section for five cases representing five different material property assignment schemes: (1) fully inhomogeneous material properties; (2) homogenous material properties (as in Piziali et al. (1976) and Levenston et al.”
MethodDetermination of suitable sample sizes for multi-patient based finite element studies
Radcliffe, I. A. J., Prescott, P., Man, H. S., & Taylor, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.007 · Cited by 32
Validation of multiple subject-specific finite element models of unicompartmental knee replacement
Tuncer, M., Cobb, J. P., Hansen, U. N., & Amis, A. A. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.03.020 · Cited by 34
Messina, C., Piodi, L. P., Grossi, E., Eller-Vainicher, C., Bianchi, M. L., Ortolani, S., Stefano, M. D., Rinaudo, L., Sconfienza, L. M., & Ulivieri, F. M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0229820 · Cited by 29
“The mechanical properties of the model are defined in a stiffness matrix assigning elastic modulus depending on local BMD according to Morgan’s equations [20].”
MethodOng, K. L., Day, J. S., Kurtz, S. M., Field, R. E., & Manley, M. T. (2008) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.08.005 · Cited by 28
“Nonhomogeneous, isotropic, linear elastic material properties were assigned to the trabecular bone based on the QCT data and previously reported density-modulus relationships for proximal femoral bone [17].”
BackgroundSas, A., Pellikaan, P., Kolk, S., Marty, P., Scheerlinck, T., & van Lenthe, H. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24240 · Cited by 27
“The HUs were divided over 20 material categories and converted to apparent density (r) assuming a linear relationship.12 The density-modulus relationship from Morgan et al.13 (E¼ 6850 r1.”
MethodModelling Human Locomotion to Inform Exercise Prescription for Osteoporosis
Martelli, S., Beck, B. R., Saxby, D. J., Lloyd, D. G., Pivonka, P., & Taylor, M. (2020) · Current Osteoporosis Reports · doi:10.1007/s11914-020-00592-5 · Cited by 31
Molinari, L., Falcinelli, C., Gizzi, A., & Martino, A. C. D. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104359 · Cited by 27
Ulivieri, F. M., Rinaudo, L., Piodi, L. P., Messina, C., Sconfienza, L. M., Sardanelli, F., Guglielmi, G., & Grossi, E. (2021) · PLoS ONE · doi:10.1371/journal.pone.0245967 · Cited by 29
“2003 [29], whereas the definition of boundary conditions depends on the anatomic site.”
BackgroundInter-subject variability effects on the primary stability of a short cementless femoral stem
Bah, M. T., Shi, J., Heller, M. O. W., Suchier, Y., Lefèbvre, F., Young, P. G., King, L. J., Dunlop, D. G., Boettcher, M., Draper, E. R. C., et al. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.01.037 · Cited by 27
A novel approach to estimate trabecular bone anisotropy from stress tensors
Hazrati, J., Ito, K., & van Rietbergen, B. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0584-6 · Cited by 31
“The bone material properties are then derived using some sort of empirical power law that relates the measured density to local bone stiffness and strength (Carter and Hayes 1976; Keyak 2001; Morgan et al. 2003; Rice et al. 1988; Taddei et al. 2007).”
BackgroundMartelli, S., Kersh, M. E., & Pandy, M. G. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.08.001 · Cited by 36
Liu, S., Qi, W., Zhang, Y., Wu, Z., Yan, Y., & Lei, W. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-83 · Cited by 27
“The material properties of cancellous bone, including its apparent density, Young’s modulus and yield strength, as derived from the literature [20,21], were adopted.”
MethodInfluentialPakdel, A., Fialkov, J. A., & Whyne, C. M. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.03.015 · Cited by 29
“modulus relationship derived by Morgan et al. (2003) whose experimental data”
MethodResultAssessment of finite element models for prediction of osteoporotic fracture
Lee, Y., Ogihara, N., & Lee, T. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.05.018 · Cited by 31
Väänänen, S. P., Grassi, L., Venäläinen, M. S., Matikka, H., Zheng, Y., Jurvelin, J. S., & Isaksson, H. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.06.015 · Cited by 27
Distefano, F., & Epasto, G. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106477 · Cited by 31
Scholz, R., Hoffmann, F., von Sachsen, S., Drossel, W., Klöhn, C., & Voigt, C. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.045 · Cited by 25
Sjovold, S. G., Zhu, Q. A., Bowden, A. E., Larson, C. R., de Bakker, P. M., Villarraga, M. L., Ochoa, J. A., Rosler, D. M., & Cripton, P. A. (2012) · European Spine Journal · doi:10.1007/s00586-012-2253-8 · Cited by 26
Al‐Barghouthi, A., Lee, S., Solitro, G. F., Latta, L. L., & Travascio, F. (2020) · JBMR Plus · doi:10.1002/jbm4.10351 · Cited by 26
“Using experimental or computational approaches focusing on entire anatomical structures such as the vertebral body, several studies correlated parameters describing bone density to modulus of elasticity((12)) and permeability.”
BackgroundUsefulness of Dual X-ray Absorptiometry-Derived Bone Geometry and Structural Indexes in Mastocytosis
Ulivieri, F. M., Rinaudo, L., Piodi, L. P., Barbieri, V., Marotta, G., Sciumé, M., Grifoni, F. I., & Cesana, B. M. (2020) · Calcified Tissue International · doi:10.1007/s00223-020-00749-5 · Cited by 27
Mathai, B., & Gupta, S. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4052227 · Cited by 27
Singh, A. P., Rana, M., Pal, B., Datta, P., Majumder, S., & Chowdhury, A. R. (2023) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2023.103959 · Cited by 27
Advanced Ti–Nb–Ta Alloys for Bone Implants with Improved Functionality
Saß, J., Sellin, M., Kauertz, E., Johannsen, J., Weinmann, M., Stenzel, M., Frank, M., Vogel, D., Bader, R., & Jonitz‐Heincke, A. (2024) · Journal of Functional Biomaterials · doi:10.3390/jfb15020046 · Cited by 31
“This is in full agreement with the results of the previous light microscopic investigations in [18].”
ResultMartelli, S., Taddei, F., Cristofolini, L., Gill, H. S., & Viceconti, M. (2010) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim728 · Cited by 26
Validation of a new multiscale finite element analysis approach at the distal radius
Johnson, J. E., & Troy, K. L. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.03.005 · Cited by 28
Awadalla, M., Al‐Dirini, R. M. A., O’Rourke, D., Solomon, L. B., Heldreth, M., & Taylor, M. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.23851 · Cited by 26
“1C).(31) The mean Morgan modulus density relationship (mMo) was used to simulate a healthy bone (Fig.”
MethodThe effect of short-stem humeral component sizing on humeral bone stress
Langohr, G. D. G., Reeves, J. M., Roche, C. P., Faber, K. J., & Johnson, J. A. (2019) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2019.08.018 · Cited by 29
Alterations in DNA methylation profiles in cancellous bone of postmenopausal women with osteoporosis
Zhou, Y., Yang, L., Wang, H., Chen, X., Jiang, W., Wang, Z., Liu, S., & Liu, Y. (2020) · FEBS Open Bio · doi:10.1002/2211-5463.12907 · Cited by 26
Haïat, G., Padilla, F. R., & Laugier, P. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.824 · Cited by 29
“The power law is site specific [38]: p has been found to vary between 1.”
BackgroundMondal, S. K., & Ghosh, R. (2019) · Journal of Orthopaedics · doi:10.1016/j.jor.2019.09.019 · Cited by 25
Torres-Sánchez, C., Norrito, M., Almushref, F. R., & CONWAY, P. P. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.112026 · Cited by 27
Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty
Kwak, D.-K., Bang, S.-H., Lee, S., Park, J.-H., & Yoo, J. (2021) · Bone and Joint Research · doi:10.1302/2046-3758.104.bjr-2020-0043.r3 · Cited by 25
González, F. J. Q., Meyers, K. N., Schraut, N. B., Mehrotra, K. G., Lipman, J. D., Wright, T. M., & Ast, M. P. (2021) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000001912 · Cited by 25
Mathai, B., Dhara, S., & Gupta, S. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104903 · Cited by 26
Turbucz, M., Pokorni, Á. J., Szőke, G., Hoffer, Z., Kiss, R. M., Lazáry, Á., & Éltes, P. E. (2022) · Applied Sciences · doi:10.3390/app122010256 · Cited by 29
Chen, G., Fan, W., Mishra, S. K., El-Atem, A., Schuetz, M., & Xiao, Y. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2012.07.006 · Cited by 28
“Young’s modulus (E) and strength (S) are related to the tooth ash density (r) by E1⁄4Ara and S1⁄4Brb [28–31].”
BackgroundMartelli, S., Taddei, F., Schileo, E., Cristofolini, L., Rushton, N., & Viceconti, M. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.07.006 · Cited by 25
Bah, M. T., Shi, J., Browne, M., Suchier, Y., Lefèbvre, F., Young, P. G., King, L. J., Dunlop, D. G., & Heller, M. O. W. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.08.004 · Cited by 29
Biomechanical Comparison of 2 Proximally Coated Femoral Stems
Ong, K. L., Day, J. S., Manley, M. T., Kurtz, S. M., & Geesink, R. G. T. (2008) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.09.012 · Cited by 24
Adams, G., Cook, R. B., Hutchinson, J. R., & Zioupos, P. (2018) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2017.00023 · Cited by 25
“, nano-indentation tests) at the same magnification level and not the commonly provided ones produced at a macro-mechanical level (Morgan et al., 2003).”
BackgroundMichalski, A. S., Edwards, W. B., & Boyd, S. K. (2017) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2017.09.001 · Cited by 24
Automation of a DXA-based finite element tool for clinical assessment of hip fracture risk
Luo, Y., Ahmed, S. I., & Leslie, W. D. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.11.020 · Cited by 27
Metadata
- Authors
- Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 36
- Issue
- 7
- Pages
- 897-904
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2088873760
- Cited by
- 1,209
- References
- 49
- Citations by year
- 2026: 73 · 2025: 72 · 2024: 79 · 2023: 71 · 2022: 78 · 2021: 99 · 2020: 85 · 2019: 59 · 2018: 56 · 2017: 55 · 2016: 61 · 2015: 55 · 2014: 62 · 2013: 43 · 2012: 37
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, elastic modulus, bone mineral density, bone structure, finite element analysis, vertebrae, proximal tibia, femoral neck, power-law regression, bone mechanical properties
- MeSH terms
- Aged, Bone and Bones, Cadaver, Computer Simulation, Elasticity, Female, Femur, Femur Neck, Humans, Lumbar Vertebrae, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Thoracic Vertebrae, Tibia, Reproducibility of Results, Bone Density, Anisotropy, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.