Trabecular bone modulus–density relationships depend on anatomic site
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
One outstanding issue regarding the relationship between elastic modulus and density for trabecular bone is whether the relationship depends on anatomic site. To address this, on-axis elastic moduli and apparent densities were measured for 142 specimens of human trabecular bone from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27). Specimens were obtained from 61 cadavers (mean+/-SD age=67+/-15 years). Experimental protocols were used that minimized end-artifact errors and controlled for specimen orientation. Tissue moduli were computed for a subset of 18 specimens using high-resolution linear finite element analyses and also using two previously developed theoretical relationships (Bone 25 (1999) 481; J. Elasticity 53 (1999) 125). Resultant power law regressions between modulus and density did depend on anatomic site, as determined via an analysis of covariance. The inter-site differences were among the leading coefficients (p<0.02), but not the exponents (p>0.08), which ranged 1.49-2.18. At a given density, specimens from the tibia had higher moduli than those from the vertebra (p=0.01) and femoral neck (p=0.002); those from the trochanter had higher moduli than the vertebra (p=0.02). These differences could be as large as almost 50%, and errors in predicted values of modulus increased by up to 65% when site-dependence was ignored. These results indicate that there is no universal modulus-density relationship for on-axis loading. Tissue moduli computed using methods that account for inter-site architectural variations did not differ across site (p>0.15), suggesting that the site-specificity in apparent modulus-density relationships may be attributed to differences in architecture.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Items 101–200 of 1,000
Biomechanics of the Birmingham hip resurfacing arthroplasty
Ong, K. L., Kurtz, S. M., Manley, M. T., Rushton, N., Mohammed, N. A., & Field, R. E. (2006) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.88b8.17567 · Cited by 81
Wang, X., Zhang, L., Song, B., Zhang, J., Fan, J., Zhang, Z., Han, Q., & Shi, Y. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.06.016 · Cited by 80
Finite element prediction of surface strain and fracture strength at the distal radius
Edwards, W. B., & Troy, K. L. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.07.016 · Cited by 88
“Density-elasticity 273 relationships depend on variables such as anatomical site [17] and strain rate [18].”
BackgroundHarrison, N. M., McDonnell, P., O’Mahoney, D., Kennedy, O. D., O’Brien, F. J., & McHugh, P. E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.014 · Cited by 100
How can bone turnover modify bone strength independent of bone mass?
Hernandez, C. J. (2008) · Bone · doi:10.1016/j.bone.2008.02.001 · Cited by 93
Honeycomb structure is promising for the repair of human bone defects
Wang, S., Shi, Z., Liu, L., Huang, Z., Li, Z. A., Liu, J., & Hao, Y. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.109832 · Cited by 87
Damage accumulation in vertebral trabecular bone depends on loading mode and direction
Wolfram, U., Wilke, H., & Zysset, P. K. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.01.018 · Cited by 84
“Stiffnesses lay in the range found by others (Kopperdahl and Keaveny, 1998; Morgan et al., 2003) or were lower than those found in a study on different sites (Rincón-Kohli and Zysset, 2009).”
ResultVarghese, B. A., Short, D., Penmetsa, R. C., Goswami, T., & Hangartner, T. N. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.12.028 · Cited by 82
Yang, L., Palermo, L., Black, D. M., & Eastell, R. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2291 · Cited by 86
“598),((22)) and derived material properties from rapp by using the empirical equations of Morgan and colleagues((23,24)):”
MethodHan, C., Wang, Y., Dong, Z., Dong, Z., Li, K., Song, C., Cai, C., Yan, X., Yang, Y., & Wang, D. (2024) · International Journal of Machine Tools and Manufacture · doi:10.1016/j.ijmachtools.2024.104199 · Cited by 76
Specimen-specific modeling of hip fracture pattern and repair
Ali, A. A., Cristofolini, L., Schileo, E., Hu, H., Taddei, F., Kim, R. H., Rullkoetter, P. J., & Laz, P. J. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.10.033 · Cited by 83
“, 2010; Keyak, 2000) and on small samples (Morgan and Keaveny, 2001; Morgan et al., 2003).”
BackgroundChong, D. Y. R., Hansen, U. N., van der Venne, R., Verdonschot, N. J. J., & Amis, A. A. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.11.026 · Cited by 78
Mechanical testing of bones: the positive synergy of finite–element models and in vitro experiments
Cristofolini, L., Schileo, E., Juszczyk, M., Taddei, F., Martelli, S., & Viceconti, M. (2010) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2010.0046 · Cited by 80
Quantitative Evaluation of the Mechanical Risks Caused by Focal Cartilage Defects in the Knee
Venäläinen, M. S., Mononen, M. E., Salo, J., Räsänen, L. P., Jurvelin, J. S., Töyräs, J., Virén, T., & Korhonen, R. K. (2016) · Scientific Reports · doi:10.1038/srep37538 · Cited by 76
Jahadakbar, A., Moghaddam, N. S., Amerinatanzi, A., Dean, D., Karaca, H. E., & Elahinia, M. (2016) · Bioengineering · doi:10.3390/bioengineering3040036 · Cited by 76
“2 GPa (Figure 5) [1 The Young’s modulus for different zones of the mandible can be obtained using various methods, such as using a quantitative scaling technique to analyze CT-scan data of the patient’s mandible [41–45].”
InfluentialMechanical Loading of the Femoral Neck in Human Locomotion
Kersh, M. E., Martelli, S., Zebaze, R., Seeman, E., & Pandy, M. G. (2018) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3529 · Cited by 90
“The apparent BMD was then converted to an apparent Young’s modulus using the relationships derived by Morgan and colleagues((22)) (Bonemat; Istituto Ortopedico Rizzoli, Bologna, Italy; http://www.”
MethodKelly, N., & McGarry, P. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.11.013 · Cited by 88
“Its material properties are dependent on many factors including density, age, sex, species, geometry and anatomic site (Goldstein, 1987; Keaveny et al., 1993b; Morgan et al., 2003).”
BackgroundEvaluation of the generality and accuracy of a new mesh morphing procedure for the human femur
Grassi, L., Hraiech, N., Schileo, E., Ansaloni, M., Rochette, M., & Viceconti, M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.09.014 · Cited by 75
Giambini, H., Dragomir‐Daescu, D., Huddleston, P. M., Camp, J. J., An, K., & Nassr, A. N. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4031572 · Cited by 75
Jang, I. G., & Kim, I. Y. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.012 · Cited by 84
Laz, P. J., Stowe, J. Q., Baldwin, M. A., Petrella, A. J., & Rullkoetter, P. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.03.013 · Cited by 76
“…Young’s modulus, and density and bone strength (e.g. Carter and Hayes, 1977; Bentzen et al., 1987; Hvid et al., 1989; Snyder and Schneider, 1991; Keller, 1994; Rho et al., 1995; Hernandez et al., 2001; Morgan et al., 2003) for various bones, with average relationships fit to the experimental data.”
BackgroundInfluentialInzana, J. A., Varga, P., & Windolf, M. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.04.021 · Cited by 78
Computational load estimation of the femur
Campoli, G., Weinans, H., & ZADPOOR, A. A. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.02.011 · Cited by 75
“A global picture of the proposed methodology (a) and a schematic drawing of the wavelet decomposition method (b) and feed-forward ANN that are used in the current study (Zadpoor et al., 2009) (c).”
InfluentialYang, H., Ma, X., & Guo, T. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.01.004 · Cited by 75
Experimental validation of DXA-based finite element models for prediction of femoral strength
Dall’Ara, E., Eastell, R., Viceconti, M., Pahr, D. H., & Yang, L. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.06.004 · Cited by 78
“The mechanical properties in each element were then calculated from the empirical equations provided by Morgan et al. (2003), Morgan and Keaveny (2001): Modulus of Elasticity ðMPaÞ ¼ 15010ρ2:18app if ρappr0:280 g=cm3 6850ρ1:49app if ρapp40:280 g=cm 3 8< : Compressive yield stress Sc ðMPaÞ ¼…”
Methodden Buijs, J. O., & Dragomir‐Daescu, D. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.11.008 · Cited by 78
“[20] we derived E = 14.”
Empirical relationships between bone density and ultimate strength: A literature review
Fleps, I., Bahaloo, H., Zysset, P. K., Ferguson, S. J., Pálsson, H., & Helgason, B. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103866 · Cited by 85
Fabrication of the antibiotic-releasing gelatin/PMMA bone cement
Chen, L., Tang, Y., Zhao, K., Zha, X., Liu, J., Bai, H., & Wu, Z. (2019) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2019.110448 · Cited by 76
Perilli, E., Baleani, M., Öhman‐Mägi, C., Baruffaldi, F., & Viceconti, M. (2007) · Bone · doi:10.1016/j.bone.2007.07.014 · Cited by 79
A comparative study of orthotropic and isotropic bone adaptation in the femur
Geraldes, D. M., & Phillips, A. (2014) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2633 · Cited by 85
“For the converged solutions of the orthotropic and isotropic iterative simulations, the density of each element was calculated using a modulus–density relationship measured for the trabecular bone in the femoral neck [72] (Equation 10).”
MethodCompressive properties of trabecular bone in the distal femur
Burgers, T., Mason, J., Niebur, G. L., & Ploeg, H. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.11.018 · Cited by 77
Buell, T. J., Bess, S. R., Xu, M., Schwab, F. J., Lafage, V., Ames, C. P., Shaffrey, C. I., & Smith, J. S. (2019) · Journal of Neurosurgery Spine · doi:10.3171/2018.10.spine18429 · Cited by 70
Beavers, K. M., Walkup, M. P., Weaver, A. A., Lenchik, L., Kritchevsky, S. B., Nicklas, B. J., Ambrosius, W. T., Stitzel, J. D., Register, T. C., Shapses, S. A., et al. (2018) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3555 · Cited by 69
“Subject-specific vBMD (rCT) was used to adjust the elastic modulus of the femoral cortex [E, GPa; Equation (1)]((51,52)) and vertebral trabecular bone [E, MPa; Equation (2)]((53)) in the FE models.”
MethodFabric-based Tsai–Wu yield criteria for vertebral trabecular bone in stress and strain space
Wolfram, U., Gross, T. J., Pahr, D. H., Schwiedrzik, J. J., Wilke, H., & Zysset, P. K. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.07.005 · Cited by 79
Mechanical Heterogeneity in the Bone Microenvironment as Characterized by Atomic Force Microscopy
Chen, X., Hughes, R., Mullin, N., Hawkins, R. J., Holen, I., Brown, N. J., & Hobbs, J. K. (2020) · Biophysical Journal · doi:10.1016/j.bpj.2020.06.026 · Cited by 72
Helgason, B., Pálsson, H., Rúnarsson, T. P., Frossard, L. A., & Viceconti, M. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.11.015 · Cited by 68
Pauchard, Y., Fitze, T., Browarnik, D., Eskandari, A., Pauchard, I., Enns-Bray, W. S., Pálsson, H., Sigurdsson, S. O., Ferguson, S. J., Harris, T. B., et al. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1181173 · Cited by 81
“= 0.005∕s which was the strain rate used in the experimental testing by Morgan et al. (2003).”
MethodInfluentialTantalum implanted entangled porous titanium promotes surface osseointegration and bone ingrowth
Wang, Q., Qiao, Y., Cheng, M., Jiang, G., He, G., Chen, Y., Zhang, X., & Liu, X. (2016) · Scientific Reports · doi:10.1038/srep26248 · Cited by 66
Krone, R., & Schuster, P. (2006) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2006-01-0064 · Cited by 67
“74 GPa [17] and are similar to values reported in [6] " and [16].”
BackgroundResultCong, A. X., den Buijs, J. O., & Dragomir‐Daescu, D. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.09.018 · Cited by 82
“The power law proposed by Morgan et al. (2003) produced the best match to the measured stiffness, although it tended to overestimate the stiffness for femurs with stiffness values above ~2000 N mm-1.”
BackgroundMethodInfluentialComputational Foot Modeling: Scope and Applications
Orcajo, E. M., Bayod, J., & Casas, E. B. D. L. (2015) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-015-9146-z · Cited by 70
McErlain, D. D., Milner, J. S., Ivanov, T. G., Jencikova-Celerin, L., Pollmann, S. I., & Holdsworth, D. W. (2010) · Bone · doi:10.1016/j.bone.2010.11.010 · Cited by 79
“developed several bone densitymodulus relationships experimentally using samples taken from several anatomic sites [28], which have demonstrated excellent prediction characteristics when applied to subject-specific FE models validated against in-vitro testing of human cadaveric specimens [38].”
BackgroundXiao, Z., Wang, L., Gong, H., & Zhu, D. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-31 · Cited by 65
“The material property of the bone structure was represented in MIMICS using some empirical expressions of the relationship among density, CT value, and Young’s modulus [23].”
MethodHelgason, B., Gilchrist, S. E., Ariza, O., Vogt, P., Enns-Bray, W. S., Widmer, R. P., Fitze, T., Pálsson, H., Pauchard, Y., Guy, P., et al. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.03.006 · Cited by 70
On the Relation of Bone Mineral Density and the Elastic Modulus in Healthy and Pathologic Bone
Nobakhti, S., & Shefelbine, S. J. (2018) · Current Osteoporosis Reports · doi:10.1007/s11914-018-0449-5 · Cited by 78
Cilla, M., Borgiani, E., Martínez, J. M., Duda, G. N., & Checa, S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0183755 · Cited by 64
The Potential for Bone Loss in Acetabular Structures Following THA
Manley, M. T., Ong, K. L., & Kurtz, S. M. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000238855.54239.fd · Cited by 67
“isotropic, linear elastic material properties were assigned to the trabecular bone based on the QCT data and density-modulus relationships reported in the literature (Table 1).(12,34) Cortical”
MethodEberle, S., Göttlinger, M., & Augat, P. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.08.022 · Cited by 62
Grassi, L., Väänänen, S. P., Ristinmaa, M., Jurvelin, J. S., & Isaksson, H. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.02.032 · Cited by 63
“relationship were obtained (5000 με/s, (Bayraktar et al., 2004; Morgan et al., 2003)).”
BackgroundModelling of femur fracture using finite element procedures
Marco, M., Giner, E., Larrainzar‐Garijo, R., Caeiro, J. R., & Miguélez, M. H. (2018) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2018.04.024 · Cited by 65
Jiang, H.-J., Xu, J. R., Qiu, Z.-Y., Ma, X., Zhang, Z., Tan, X.-X., Cui, Y. X., & Cui, F. (2015) · Materials · doi:10.3390/ma8052616 · Cited by 61
“The compressive elastic modulus of normal human vertebral body is 50–800 MPa [4–6], while the PMMA bone cements form hard solid body with an elastic modulus of 2000–3700 MPa [7,8], which is much higher than that of normal human vertebral body.”
BackgroundBiomechanical effects of metastasis in the osteoporotic lumbar spine: A Finite Element Analysis
Salvatore, G., Berton, A., Giambini, H., Ciuffreda, M., Florio, P., Longo, U. G., Denaro, V., Thoreson, A. R., & An, K. (2018) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-018-1953-6 · Cited by 62
Pal, B., Gupta, S., & New, A. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim488 · Cited by 60
Geraldes, D. M., Modenese, L., & Phillips, A. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0740-7 · Cited by 65
“𝐸rep = max ( 𝐸mean, 2(1 + ν)𝐺mean) (S4) The conversion between orthotropic properties and density was adapted from an experimentally derived curve relating mass and elastic modulus for the femoral neck (Morgan et al. 2003).”
MethodInfluentialStrain energy in the femoral neck during exercise
Martelli, S., Kersh, M. E., Schache, A. G., & Pandy, M. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.03.036 · Cited by 65
“, 2008a, and converted into isotropic Young's modulus values using the relationship given by Morgan et al. (2003). The Young's modulus values were mapped onto the finite-element mesh using Bonemat (Super Computing Solutions, Italy).”
MethodSubject specific finite element analysis of stress shielding around a cementless femoral stem
Pettersen, S. H., Wik, T. S., & Skallerud, B. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.11.003 · Cited by 59
“The density–stiffness relationship for bone has been shown to vary at different locations (Morgan et al., 2003) and depends on its microstructural architecture (Stauber et al., 2006).”
BackgroundInfluentialCalibration of a constitutive model for the post-yield behaviour of cortical bone
Mullins, L. P., Bruzzi, M., & McHugh, P. E. (2008) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2008.11.003 · Cited by 68
“Further investigations, which have focused predominantly on trabecular bone, have proven to be extremely effective in terms of predicting the macroscale response and properties (Keyak and Rossi, 2000; Niebur et al., 2000; Morgan et al., 2003; Bayraktar et al., 2004).”
BackgroundTrabelsi, N., & Yosibash, Z. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004180 · Cited by 73
Hardness, an Important Indicator of Bone Quality, and the Role of Collagen in Bone Hardness
Ibrahim, A. M. M., Magliulo, N., Groben, J., Padilla, A., Akbik, F., & Hamid, Z. A. (2020) · Journal of Functional Biomaterials · doi:10.3390/jfb11040085 · Cited by 62
“The mechanical properties of bone have long been known to depend on the degree of hydration, and bound water contributes to bone toughness [53,54].”
BackgroundUse of Computational Modeling to Study Joint Degeneration: A Review
Mukherjee, S., Nazemi, M., Jonkers, I., & Geris, L. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00093 · Cited by 69
“A range of elastic moduli from 10 to 2770 MPa has been reported for the epiphyseal trabecular bone (Keyak et al., 1994; Zysset et al., 1994; Morgan et al., 2003; Amini, 2013).”
BackgroundGoodheart, J. R., Cleary, R. J., Damron, T. A., & Mann, K. A. (2015) · Journal of Orthopaedic Research® · doi:10.1002/jor.22887 · Cited by 61
Shimko, D. A., & Nauman, E. A. (2006) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30605 · Cited by 69
Bevill, G. R., Eswaran, S. K., Farahmand, F., & Keaveny, T. M. (2008) · Bone · doi:10.1016/j.bone.2008.11.015 · Cited by 67
“However, the tissue density was nearly identical across these three sites and the apparent density for all of these sites was greater than that for vertebral bone [30].”
Self-citationPower‐law hereditariness of hierarchical fractal bones
Deseri, L., Paola, M. D., Zingales, M., & Pollaci, P. (2013) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2572 · Cited by 62
“The results of best-fitting procedure, collected in Table I, show that the power-law exponent depends on the anatomical location of the considered specimen [33].”
BackgroundPakuła, M., Padilla, F. R., Laugier, P., & Kaczmarek, M. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2839016 · Cited by 67
Helgason, B., Gilchrist, S. E., Ariza, O., Chak, J. D., Guoyan Zheng, A., Widmer, R. P., Ferguson, S. J., Guy, P., & Cripton, P. A. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.02.019 · Cited by 57
Biomechanics Modeling of the Musculoskeletal Apparatus: Status and Key Issues
Viceconti, M., Testi, D., Taddei, F., Martelli, S., Clapworthy, G., & Jan, S. V. S. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.871769 · Cited by 58
“failure criteria [72], [73].”
Başaran, R., Efendioğlu, M., Kakşı, M., Çelik, T., Mutlu, İ., & Uçar, M. (2019) · World Neurosurgery · doi:10.1016/j.wneu.2019.05.077 · Cited by 55
Kechagias, S., Oosterbeek, R. N., Munford, M. J., Ghouse, S., & Jeffers, J. R. T. (2022) · Additive manufacturing · doi:10.1016/j.addma.2022.102730 · Cited by 57
Schätzlein, E., Kicker, C., Söhling, N., Ritz, U., Neijhoft, J., Henrich, D. M., Frank, J. M., Marzi, İ., & Blaeser, A. (2022) · Polymers · doi:10.3390/polym14122389 · Cited by 59
Danielson, M. E., Beck, T., Karlamangla, A. S., Greendale, G. A., Atkinson, E. J., Lian, Y., Khaled, A. S., Keaveny, T. M., Kopperdahl, D. L., Ruppert, K. M., et al. (2012) · Osteoporosis International · doi:10.1007/s00198-012-2066-y · Cited by 55
Self-citationStress shielding in bone of a bone-cement interface
Zhang, Q.-H., Cossey, A. J., & Tong, J. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.01.009 · Cited by 54
Moussa, A., Rahman, S., Xu, M., Tänzer, M., & Pasini, D. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103705 · Cited by 53
“The relation between elastic properties and BMD varies with anatomical position (Leung et al., 2009; Morgan et al., 2003).”
BackgroundPolley, C., Radlof, W., Hauschulz, F., Benz, C., Sander, M., & Seitz, H. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104882 · Cited by 52
Open forward and inverse problems in theoretical modeling of bone tissue adaptation
ZADPOOR, A. A. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.05.017 · Cited by 58
“The heterogeneous mechanical properties of bones are then related to bone density through empirical relationships (Kabel et al., 1999; Morgan et al., 2003; Van Rietbergen et al., 2005).”
BackgroundEnns-Bray, W. S., Bahaloo, H., Fleps, I., Ariza, O., Gilchrist, S. E., Widmer, R. P., Guy, P., Pálsson, H., Ferguson, S. J., Cripton, P. A., et al. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.10.033 · Cited by 57
Villamor, E., Monserrat, C., del Río, L., Romero-Martín, J. A., & Rupérez, M. J. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105484 · Cited by 61
“Then, bone material properties were calculated using the empirical equations obtained by Morgan and colleagues [35, 36, 37]:”
Method3D-Printed Architected Materials Inspired by Cubic Bravais Lattices
Libonati, F., Graziosi, S., Ballo, F. M., Mognato, M., & Sala, G. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01708 · Cited by 59
Latif, A., Mehats, A., Elcocks, M., Rushton, N., Field, R. E., & Jones, E. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3256-6 · Cited by 52
Srinivasan, B., Kopperdahl, D. L., Amin, S., Atkinson, E. J., Camp, J. J., Robb, R. A., Riggs, B. L., ORWOLL, E. S., Melton, L. J., Keaveny, T. M., et al. (2011) · Osteoporosis International · doi:10.1007/s00198-011-1822-8 · Cited by 60
“5 mm cube 8-noded finite element, and material properties for cortical or trabecular bone were assigned to each element using the calibrated QCT density information and empirical relations between measured bone density and tissue mechanical properties [20–22], using lower strengths for tension than compression [23, 24…”
MethodSelf-citationDragomir‐Daescu, D., Salas, C., Uthamaraj, S., & Rossman, T. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.09.016 · Cited by 55
“2004) and to provide well-defined material property input to FEA models (Genant et al. 1999; Morgan et al. 2003; Taddei et al. 2006) – two variables essential for accurate results.”
BackgroundMethodReduced Tissue-Level Stiffness and Mineralization in Osteoporotic Cancellous Bone
Kim, G., Cole, J. H., Boskey, A. L., Baker, S. P., & van der Meulen, M. C. H. (2014) · Calcified Tissue International · doi:10.1007/s00223-014-9873-4 · Cited by 52
“Bone volume fraction, as measured by microcomputed tomography scans, predicts 73–97 % of the ultimate stress and Young’s Modulus of vertebral cancellous bone [42–44].”
New QCT Analysis Approach Shows the Importance of Fall Orientation on Femoral Neck Strength
Carpenter, R. D., Beaupré, G. S., Lang, T. F., Orwoll, E. S., & Carter, D. R. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050510 · Cited by 52
“Analyses performed on bones from other locations may require the use of sitespecific relationships.((42)) Because the sectional properties are directly weighted by the elastic modulus, the analysis method presented here is sensitive to the choice of density/ elastic modulus relationship.”
BackgroundFabric dependence of wave propagation in anisotropic porous media
Cowin, S. C., & Cardoso, L. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0217-7 · Cited by 54
“Furthermore, the mass density of the solid tissue in trabecular bone ρs , has been reported to vary between 1,800 and 2, 200 Kg/m3 (Ashman and Rho 1988; Nicholson et al. 1997; Morgan et al. 2003) depending on the tissue mineral density of the sample being measured.”
Size-dependent heterogeneity benefits the mechanical performance of bone
Yao, H., Dao, M., Carnelli, D., Tai, K., & Ortiz, C. (2010) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2010.09.012 · Cited by 59
A three-dimensional finite element model of maximal grip loading in the human wrist
Gíslason, M. K., Nash, D., Nicol, A., Kanellopoulos, A., Bransby-Zachary, M., Hems, T., Condon, B. R., & Stansfield, B. W. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim527 · Cited by 61
Xu, C. H., Silder, A., Ju, Z., Hughes, J. M., Unnikrishnan, G. U., Jaques Reifman, A., & Rakesh, V. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4034216 · Cited by 54
“After mesh morphing, we converted the resultant HU values obtained in the target mesh into apparent densities and then to elastic modulus using a procedure similar to that used by Morgan et al. [26].”
MethodSingle-trabecula building block for large-scale finite element models of cancellous bone
Dagan, D., Be'ery, M., & Gefen, A. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02350998 · Cited by 59
Leung, A. S. O., Gordon, L. M., Skrinskas, T., Szwedowski, T. D., & Whyne, C. M. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim618 · Cited by 51
Bone tissue composition varies across anatomic sites in the proximal femur and the iliac crest
Donnelly, E. L., Meredith, D. S., Nguyen, J., & Boskey, A. L. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.21574 · Cited by 65
“The observed differences in bone tissue properties across anatomic sites are consistent with previously observed variation in bone tissue composition and mechanical properties across multiple anatomic sites.(16,26) These findings suggest that the use of tissue from an easily accessible site such as the iliac crest to…”
Ulivieri, F. M., & Rinaudo, L. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2020.590139 · Cited by 57
“human vertebrae, assuming a specific thickness of the modeldependent from the average width of the vertebra, from the material properties derived according to experimental Morgan equations (54), and from patient-specific loading configuration based on Han et al.”
MethodBevill, G. R., Easley, S. K., & Keaveny, T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.008 · Cited by 54
“…errors should be less significant in high-density bone (Ün et al., 2006), but such predictions are confounded by the associated changes in micro-architecture with changing bone volume fraction (Hildebrand et al., 1999) as well as potential differences between anatomic site (Morgan et al., 2003).”
BackgroundMethodInfluentialSelf-citationAldieri, A., Curreli, C., Szyszko, J. A., Mattina, A. A. L., & Viceconti, M. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107727 · Cited by 60
Regional variation of bone tissue properties at the human mandibular condyle
Kim, D., Jeong, Y., Kosel, E., Agnew, A. M., McComb, D. W., Bodnyk, K. A., Hart, R. T., Kim, M. K., Han, S. Y., & Johnston, W. M. (2015) · Bone · doi:10.1016/j.bone.2015.04.024 · Cited by 54
“Previous studies demonstrated that measured elastic modulus, tissue mineralization and composition of human bone are different between anatomic sites [18,19].”
Multiscale investigation of the functional properties of the human femur
Cristofolini, L., Taddei, F., Baleani, M., Baruffaldi, F., Stea, S., & Viceconti, M. (2008) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0077 · Cited by 49
“The relationship between the tissue density and the elastic constants was derived empirically (Morgan et al. 2003) from experimental results obtained from the tissues of a number of subjects and from selected anatomical sites (figure 4), and then generalized to all subjects and to all sites.”
MethodQuality of motion considerations in numerical analysis of motion restoring implants of the spine
Bowden, A. E., Guerin, H. L., Villarraga, M. L., Patwardhan, A. G., & Ochoa, J. A. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.12.010 · Cited by 49
Stephens, N. B., Kivell, T. L., Gross, T. J., Pahr, D. H., Lazenby, R. A., Hublin, J., Hershkovitz, I., & Skinner, M. M. (2016) · American Journal of Physical Anthropology · doi:10.1002/ajpa.23061 · Cited by 57
Tsouknidas, A., Sarrigiannidis, S., Anagnostidis, K. S., Michailidis, N., & Ahuja, S. (2015) · The Spine Journal · doi:10.1016/j.spinee.2014.12.148 · Cited by 48
“45 [2,3] Eyy5140 vyz50.”
BackgroundChanda, S., Gupta, S., & Pratihar, D. K. (2015) · Applied Soft Computing · doi:10.1016/j.asoc.2015.10.020 · Cited by 48
A Review on Recent Advances in the Constitutive Modeling of Bone Tissue
Pahr, D. H., & Reisinger, A. (2020) · Current Osteoporosis Reports · doi:10.1007/s11914-020-00631-1 · Cited by 59
Metadata
- Authors
- Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 36
- Issue
- 7
- Pages
- 897-904
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2088873760
- Cited by
- 1,209
- References
- 49
- Citations by year
- 2026: 73 · 2025: 72 · 2024: 79 · 2023: 71 · 2022: 78 · 2021: 99 · 2020: 85 · 2019: 59 · 2018: 56 · 2017: 55 · 2016: 61 · 2015: 55 · 2014: 62 · 2013: 43 · 2012: 37
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, elastic modulus, bone mineral density, bone structure, finite element analysis, vertebrae, proximal tibia, femoral neck, power-law regression, bone mechanical properties
- MeSH terms
- Aged, Bone and Bones, Cadaver, Computer Simulation, Elasticity, Female, Femur, Femur Neck, Humans, Lumbar Vertebrae, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Thoracic Vertebrae, Tibia, Reproducibility of Results, Bone Density, Anisotropy, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.