Trabecular bone modulus–density relationships depend on anatomic site
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
One outstanding issue regarding the relationship between elastic modulus and density for trabecular bone is whether the relationship depends on anatomic site. To address this, on-axis elastic moduli and apparent densities were measured for 142 specimens of human trabecular bone from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27). Specimens were obtained from 61 cadavers (mean+/-SD age=67+/-15 years). Experimental protocols were used that minimized end-artifact errors and controlled for specimen orientation. Tissue moduli were computed for a subset of 18 specimens using high-resolution linear finite element analyses and also using two previously developed theoretical relationships (Bone 25 (1999) 481; J. Elasticity 53 (1999) 125). Resultant power law regressions between modulus and density did depend on anatomic site, as determined via an analysis of covariance. The inter-site differences were among the leading coefficients (p<0.02), but not the exponents (p>0.08), which ranged 1.49-2.18. At a given density, specimens from the tibia had higher moduli than those from the vertebra (p=0.01) and femoral neck (p=0.002); those from the trochanter had higher moduli than the vertebra (p=0.02). These differences could be as large as almost 50%, and errors in predicted values of modulus increased by up to 65% when site-dependence was ignored. These results indicate that there is no universal modulus-density relationship for on-axis loading. Tissue moduli computed using methods that account for inter-site architectural variations did not differ across site (p>0.15), suggesting that the site-specificity in apparent modulus-density relationships may be attributed to differences in architecture.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Items 401–500 of 1,000
Patient-Specific Bone Multiscale Modelling, Fracture Simulation and Risk Analysis—A Survey
de Alcântara, A. C. S., Assis, I., Prada, D., Mehle, K., Schwan, S., Costa‐Paiva, L., Skaf, M. S., Wrobel, L. C., & Sollero, P. (2019) · Materials · doi:10.3390/ma13010106 · Cited by 28
“, Young’s Modulus Y, has been empirically studied by [102,118,169,281,282] and the works therein.”
BackgroundTalukdar, R. G., Mukhopadhyay, K. K., Dhara, S., & Gupta, S. (2021) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211008343 · Cited by 25
“The elastic modulus (E in MPa) was obtained by using the following apparent density and modulus relationship by Morgan et al.42 E=4730r1:56 ð2Þ A public domain software Bonemat v2.”
MethodKwak, D.-K., Bang, S.-H., Kim, W., Lee, S., Lee, S., & Yoo, J. (2021) · PLoS ONE · doi:10.1371/journal.pone.0253862 · Cited by 24
“The following bone density-HU and elastic modulus-bone density relationships were used [23,24]:”
MethodHe, Y., Luckett, J., Begines, B., Dubern, J., Hook, A. L., Prina, E., Rose, F. R. A. J., Tuck, C. J., Hague, R., Irvine, D. J., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121350 · Cited by 30
“Dynamic mechanical analysis (DMA) measurements were carried out to determine the physical properties of the printed materials, through which it was found that the moduli of both of poly-EGDPEA and poly-TCDMDA fall into the modulus range for cancellous bone, an important consideration for bone implants[40,41].”
BackgroundLow-Modulus PMMA Has the Potential to Reduce Stresses on Endplates after Cement Discoplasty
Lewin, S., Försth, P., & Persson, C. (2022) · Journal of Functional Biomaterials · doi:10.3390/jfb13010018 · Cited by 24
Zumofen, L., Kopanska, K. S., Bono, E., Kirchheim, A., de Haller, E. B., & Graf‐Hausner, U. (2022) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2021.830126 · Cited by 29
Helgason, B., Viceconti, M., Rúnarsson, T. P., & Brynjólfsson, S. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.03.007 · Cited by 30
Neural networks for analysis of trabecular bone in osteoarthritis
Khovanova, N. A., Shaikhina, T., & Mallick, K. K. (2014) · Bioinspired Biomimetic and Nanobiomaterials · doi:10.1680/bbn.14.00006 · Cited by 26
“The task of optimising or predicting these properties especially for trabecular bone becomes even more onerous due to the fact that mechanical properties of bone differ according to their anatomical location.(7) Tissue engineers are thus often faced with problems of selecting the most successful strategy for both the…”
BackgroundMulvihill, B. M., & Prendergast, P. J. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802136150 · Cited by 27
“…þ Dr: ð2Þ As a finite element can be a combination of both bone and marrow during simulated remodelling, a quadratic relationship is assumed to exist between the elastic modulus and the apparent density of bone (Morgan et al. 2003) as follows: E ¼ Kr2; ð3Þ where K is a constant equal to 650mNm4g22.”
BackgroundInfluentialFemoral head necrosis: A finite element analysis of common and novel surgical techniques
Cilla, M., Checa, S., Preininger, B., Winkler, T., Perka, C., Duda, G. N., & Pumberger, M. (2017) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2017.07.005 · Cited by 29
“Then, the apparent density was calculated based on the ash density values taken from the patient-specific CT scan following Keyak et al. (Keyak et al., 1994; Morgan et al., 2003).”
MethodInfluentialAl‐Dirini, R. M. A., Martelli, S., O’Rourke, D., Huff, D. N., Ju, Z., Clement, J. G., Besier, T. F., & Taylor, M. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.013 · Cited by 25
Patient-specific design process and evaluation of a hip prosthesis femoral stem
Abdelaal, O., Darwish, S. M., El-Hofy, H., & Saito, Y. (2018) · The International Journal of Artificial Organs · doi:10.1177/0391398818815479 · Cited by 24
Altered topological blueprint of trabecular bone associates with skeletal pathology in humans
Reznikov, N., Alsheghri, A., Piché, N., Gendron, M., Desrosiers, C., Morozova, I., Sánchez-Siles, J.-M., González-Quevedo, D., Tamimi, I., Song, J. H., et al. (2020) · Bone Reports · doi:10.1016/j.bonr.2020.100264 · Cited by 26
IN VITROACOUSTIC WAVE PROPAGATION IN HUMAN AND BOVINE CANCELLOUS BONE AS PREDICTED BY BIOT'S THEORY
Cardoso, L., MEUNIER, A., & Oddou, C. (2008) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519408002565 · Cited by 26
Soliman, M. M., Islam, M. T., Chowdhury, M. E. H., Alqahtani, A., Musharavati, F., Alam, T., Alshammari, A. S., Misran, N. B., Soliman, M. S., Mahmud, S., et al. (2023) · Journal of Materials Chemistry B · doi:10.1039/d3tb01469j · Cited by 23
Bhatia, V., Edwards, W. B., & Troy, K. L. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.04.050 · Cited by 29
“49 (Morgan et al., 2003, femoral specimens) (iii) E=8920 app1.”
BackgroundMethodJiang, H., Robinson, D. L., Lee, P. V. S., Krejany, E. O., Yates, C. J., Hickey, M., & Wark, J. D. (2020) · Osteoporosis International · doi:10.1007/s00198-020-05608-5 · Cited by 29
Mathai, B., Dhara, S., & Gupta, S. (2021) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-021-01436-6 · Cited by 24
Nazemi, S. M., Amini, M., Kontulainen, S. A., Milner, J. S., Holdsworth, D. W., Masri, B. A., Wilson, D. R., & Johnston, J. D. (2016) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2016.10.012 · Cited by 27
Ruffoni, D., & van Lenthe, H. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.09798-8 · Cited by 31
Follet, H., Peyrin, F., Vidal-Sallé, E., Bonnassie, A., Rumelhart, C., & Meunier, P. J. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.10.032 · Cited by 27
“has shown that trabecular bone modulus–density relationships depend on anatomic site (Morgan et al., 2003).”
BackgroundLee, C., Lee, J., Youn, B., Kim, H., Shin, J. K., Goh, T. S., & Lee, J. S. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.08.028 · Cited by 24
Can CT image deblurring improve finite element predictions at the proximal femur?
Falcinelli, C., Schileo, E., Pakdel, A., Whyne, C. M., Cristofolini, L., & Taddei, F. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.07.004 · Cited by 22
Troy, K. L., Davis, I. S., & Tenforde, A. S. (2021) · PM&R · doi:10.1002/pmrj.12518 · Cited by 25
Current Applications and Selected Technical Details of Dual-Energy X-Ray Absorptiometry
Sawicki, P., Tałałaj, M., Życińska, K., Zgliczyński, W. S., & Wierzba, W. (2021) · Medical Science Monitor · doi:10.12659/msm.930839 · Cited by 34
“Using vBMD and appropriate formulas developed by Morgan et al [54], material properties are calculated.”
MethodAn Overview of Selected Material Properties in Finite Element Modeling of the Human Femur
Bazyar, P., Baumgart, A., Altenbach, H., & Usbeck, A. K. (2023) · Biomechanics · doi:10.3390/biomechanics3010012 · Cited by 31
“The following criteria guided the selection of these: 1 All orthogonal moduli are comparable to values published in [35] and [23] and fall within the generally accepted range of 0–4.”
BackgroundNazemi, S. M., Amini, M., Kontulainen, S. A., Milner, J. S., Holdsworth, D. W., Masri, B. A., Wilson, D. R., & Johnston, J. D. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.05.002 · Cited by 30
“As E-BMD relationships depend on anatomic site (Morgan et al., 2003), seven trabecular-specific and two cortical-specific empirical EBMD relationships specific to the human tibia (Anderson et al., 1992; Keyak et al., 1994; Linde et al., 1992; Morgan et al., 2003; Rho et al., 1995; Snyder and…”
BackgroundInfluentialHolub, O., López, A., Borse, V. H., Engqvist, H., Kapur, N., Hall, R. M., & Persson, C. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.06.026 · Cited by 22
Large-scale microstructural simulation of load-adaptive bone remodeling in whole human vertebrae
Badilatti, S. D., Christen, P., Levchuk, A., Hazrati, J., van Rietbergen, B., Parkinson, I. H., & Müller, R. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0715-8 · Cited by 25
Väänänen, S. P., Jurvelin, J. S., & Isaksson, H. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0352-9 · Cited by 22
“The value of Young’s modulus for each element was defined by converting the value of bone mineral density from the mean of the 3x3x3-neighbourhood of the element centre to Young’s modulus according to the literature (Morgan et al. 2003; Väänänen et al. 2011).”
MethodXiao, Z., Wang, L., Gong, H., Zhu, D., & Zhang, X. (2011) · Theoretical and Applied Mechanics Letters · doi:10.1063/2.1106401 · Cited by 24
Lennon, A., Britton, J. R., MacNiocaill, R. F., Byrne, D. P., Kenny, P. J., & Prendergast, P. J. (2007) · Journal of Orthopaedic Research® · doi:10.1002/jor.20346 · Cited by 23
“Furthermore, values for cancellous bone were in the higher range of reported values.(20,34) To gain an understanding of how these issues might affect predictions, a second analysis was performed for the lowest ranked and second oldest of the revised patients (patient H).”
ResultVirtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures
Petfield, J. L., Hayeck, G. T., Kopperdahl, D. L., Nesti, L. J., Keaveny, T. M., & Hsu, J. R. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23335 · Cited by 22
Self-citationMicroCT-based finite element models as a tool for virtual testing of cortical bone
Ramezanzadehkoldeh, M., & Skallerud, B. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.04.011 · Cited by 27
Functional Adaptation of the Calcaneus in Historical Foot Binding
Reznikov, N., Phillips, C., Cooke, M., Garbout, A., Ahmed, F., & Stevens, M. M. (2017) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3185 · Cited by 25
“This follows from its lower apparentmodulus((20,21)) in comparison to that of compact bone.”
BackgroundAssociation of vertebral endplate microstructure with bone strength in men and women
McKay, M., Jackman, T. M., Hussein, A. I., Guermazi, A., Liu, J., & Morgan, E. F. (2019) · Bone · doi:10.1016/j.bone.2019.115147 · Cited by 21
Self-citationDifferences in the Crack Resistance of Interstitial, Osteonal and Trabecular Bone Tissue
Mullins, L. P., Sassi, V., McHugh, P. E., & Bruzzi, M. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9797-8 · Cited by 23
Effects of loading rate on the of mechanical behavior of the femur in falling condition
Askarinejad, S., Johnson, J. E., Rahbar, N., & Troy, K. L. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.04.038 · Cited by 22
Larrañaga, A., Diamanti, E., Rubio, E., Palomares, T., Alonso-Varona, A., Aldazabal, P., Martin, F. J., & Sarasua, J. R. (2014) · Materials Science and Engineering: C · doi:10.1016/j.msec.2014.05.061 · Cited by 21
Taddei, F., Falcinelli, C., Balistreri, L., Henyš, P., Baruffaldi, F., Sigurdsson, S. O., Gudnason, V. G., Harris, T. B., Dietzel, R., Armbrecht, G., et al. (2015) · Osteoporosis International · doi:10.1007/s00198-015-3404-7 · Cited by 25
Numerical simulations on periprosthetic bone remodeling: a systematic review
Mirulla, A. I., Pinelli, S., Zaffagnini, S., Nigrelli, V., Ingrassia, T., Paolo, S. D., & Bragonzoni, L. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106072 · Cited by 25
Sanjay, D., Bhardwaj, J. S., Kumar, N., & Chanda, S. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02625-w · Cited by 21
Garavelli, C., Curreli, C., Palanca, M., Aldieri, A., Cristofolini, L., & Viceconti, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0272529 · Cited by 21
“[31] and then to the elastic modulus (E) following the equation provided by Morgan [33], with ρapp = ρash/0.”
MethodInfluentialJohnston, J. D., Kontulainen, S. A., Masri, B. A., & Wilson, D. R. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2011.06.009 · Cited by 23
“Existing studies have established stiffness–density relationships using compression testing of excised trabecular bone samples from epiphyseal or metaphyseal regions (typically located greater than 5 mm from subchondral surface) (Carter and Hayes, 1977; Keyak et al., 1994; Linde et al., 1992; Morgan et al., 2003).”
BackgroundMultiscale response of the human skull to quasi-static compression
Alexander, S. L., Gunnarsson, C. A., Rafaels, K. A., & Weerasooriya, T. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103492 · Cited by 21
Mechanical and morphological characterization of PMMA/bone composites in human femoral heads
Sas, A., Helgason, B., Ferguson, S. J., & van Lenthe, H. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104247 · Cited by 22
Risk Assessment of Hip Fracture Based on Machine Learning
Galassi, A., Martín‐Guerrero, J. D., Villamor, E., Monserrat, C., & Rupérez, M. J. (2020) · Applied Bionics and Biomechanics · doi:10.1155/2020/8880786 · Cited by 22
In Vitro and In Vivo Response to Low-Modulus PMMA-Based Bone Cement
Carlsson, E., Mestres, G., Treerattrakoon, K., López, A., Ott, M. K., Larsson, S., & Persson, C. (2015) · BioMed Research International · doi:10.1155/2015/594284 · Cited by 21
“However, there is no data available on the in vivo biocompatibility of any low-modulus cement.”
BackgroundTaddei, F., Martelli, S., Gill, H. S., Cristofolini, L., & Viceconti, M. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000065 · Cited by 21
Dahl, M. C., Ahrens, M. J., Sherman, J. E., & Martz, E. O. (2010) · Spine · doi:10.1097/brs.0b013e3181bef192 · Cited by 23
Chen, Y., Pani, M., Taddei, F., Mazzà, C., Li, X., & Viceconti, M. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4028106 · Cited by 24
Leahy, P. D., Smith, B. S., Easton, K. L., Kawcak, C. E., Eickhoff, J. C., Shetye, S. S., & Puttlitz, C. M. (2010) · Bone · doi:10.1016/j.bone.2010.01.366 · Cited by 25
Structural strength of cancellous specimens from bovine femur under cyclic compression
Endo, K., Yamada, S., Todoh, M., Takahata, M., Iwasaki, N., & TADANO, S. (2016) · PeerJ · doi:10.7717/peerj.1562 · Cited by 31
On the Failure Initiation in the Proximal Human Femur Under Simulated Sideways Fall
Bahaloo, H., Enns-Bray, W. S., Fleps, I., Ariza, O., Gilchrist, S. E., Widmer, R. P., Guy, P., Pálsson, H., Ferguson, S. J., Cripton, P. A., et al. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1952-z · Cited by 21
Garavelli, C., Aldieri, A., Palanca, M., Dall’Ara, E., & Viceconti, M. (2025) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-025-01950-x · Cited by 20
“The density ( ρ APP [g/ cm 3 ])—elasticity (E [MPa]) relationship was derived from the literature (Morgan et al. 2003; Schileo et al. 2008) (Eq.”
Bahia, M. T., Hecke, M. B., Mercuri, E. G. F., & Pinheiro, M. M. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103657 · Cited by 22
Glenday, J. D., Wright, T. M., Lipman, J. D., Sculco, P. K., Mayman, D. J., Vigdorchik, J. M., & González, F. J. Q. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25129 · Cited by 23
“We combined the empirical equations from Morgan et al.26 (Equation 1) and Snyder and Schneider27 (Equation 2), as proposed previously.25 = ρ ρ ≤ …E 15520 if 0.41g/cc1.”
MethodYang, H., Bayoğlu, R., Clary, C. W., & Rullkoetter, P. J. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25344 · Cited by 20
Tilton, M., Jacobs, E., Overdorff, R., Potes, M. D. A., Lu, L., & Manogharan, G. P. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105612 · Cited by 20
Zhang, Y., Luo, W., Zheng, L., Hu, J., Nie, L., Zeng, H., Tan, X., Jiang, Y., Li, Y., Zhao, T., et al. (2022) · Stem Cell Research & Therapy · doi:10.1186/s13287-022-03221-3 · Cited by 20
Does facial soft tissue protect against zygomatic fractures? Results of a finite element analysis
Huempfner-Hierl, H., Bohne, A., Schaller, A., Wollny, G., & Hierl, T. (2015) · Head & Face Medicine · doi:10.1186/s13005-015-0078-5 · Cited by 20
The connection between cellular mechanoregulation and tissue patterns during bone healing
Repp, F., Vetter, A., Duda, G. N., & Weinkamer, R. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1285-8 · Cited by 20
Tümer, N., Waarsing, J. H., Bos, P. K., Weinans, H., & ZADPOOR, A. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.06.027 · Cited by 20
“The relationship proposed by Morgan et al. (2003) was used to relate apparent density and Young's modulus as it has been found to be the most accurate relationship (Scholz et al., 2013).”
Basafa, E., & Armand, M. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.05.002 · Cited by 20
“1 (Morgan et al., 2003; Keller, 1994).”
Badilatti, S. D., Christen, P., Parkinson, I. H., & Müller, R. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.10.002 · Cited by 22
Al‐Dirini, R. M. A., O’Rourke, D., Huff, D. N., Martelli, S., & Taylor, M. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4039824 · Cited by 20
Sinha, R., Janaswamy, S., & Prasad, A. (2020) · Materialia · doi:10.1016/j.mtla.2020.100881 · Cited by 20
Mapping the Multi‐Directional Mechanical Properties of Bone in the Proximal Tibia
Munford, M. J., Ng, K. C. G., & Jeffers, J. R. T. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004323 · Cited by 19
Fernández, M. P., Sasso, S. J., McPhee, S., Black, C. R. M., Kanczler, J. M., Tozzi, G., & Wolfram, U. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105303 · Cited by 21
Ural, A., Bruno, P., Zhou, B., Shi, X., & Guo, X.-D. E. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.02.009 · Cited by 20
“However, there is substantial site and specimen specific variation between these relationships (Austman et al., 2008; Helgason et al., 2008; Morgan et al., 2003).”
BackgroundDiamant, I., Shahar, R., & Gefen, A. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344727 · Cited by 21
“99 g m l - 1 (for trabeculae in the vertebrae (MORGAN et al., 2003).”
InfluentialNazemi, S. M., Kalajahi, S. M. H., Cooper, D. M. L., Kontulainen, S. A., Holdsworth, D. W., Masri, B. A., Wilson, D. R., & Johnston, J. D. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.05.018 · Cited by 23
Trabecular Architecture and Mechanical Heterogeneity Effects on Vertebral Body Strength
Auger, J., Frings, N. R., Wu, Y., Marty, A. G., & Morgan, E. F. (2020) · Current Osteoporosis Reports · doi:10.1007/s11914-020-00640-0 · Cited by 25
Self-citationAldieri, A., Terzini, M., Audenino, A. L., Bignardi, C., Paggiosi, M., Eastell, R., Viceconti, M., & Bhattacharya, P. (2022) · Annals of Biomedical Engineering · doi:10.1007/s10439-022-02924-1 · Cited by 19
Wang, Y., Wang, M., Li, C., Nakamura, Y., Deng, L., Yamako, G., Chosa, E., & Pan, C. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05168-1 · Cited by 19
Zhang, Q., Chen, Z., Peng, Y., Jin, Z. M., & Qin, L. (2023) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2023.08.003 · Cited by 23
“129 apparent density of bone volume contained within the element [33,35, 36].”
BackgroundGong, H., Zhang, M., & Fan, Y. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519411004010 · Cited by 19
ESWARAN, S. K., Fields, A. J., Nagarathnam, P., & Keaveny, T. M. (2008) · Pacific Symposium on Biocomputing (PSB) · doi:10.1142/9789812836939_0028 · Cited by 19
Self-citationBasaruddin, K. S., TAKANO, N., Akiyama, H., & Nakano, T. (2013) · MATERIALS TRANSACTIONS · doi:10.2320/matertrans.me201307 · Cited by 20
Experimental validation of finite element predicted bone strain in the human metatarsal
Fung, A., Loundagin, L. L., & Edwards, W. B. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.06.010 · Cited by 26
Mathai, B., & Gupta, S. (2020) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3353 · Cited by 19
Kim, D., Kwon, H., Jeong, Y., Chien, H., Crance, S., Agnew, A. M., Battula, S., Lee, J. W., & Wen, H. B. (2015) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12319 · Cited by 19
Campoli, G., Baka, N., Kaptein, B. L., Valstar, E. R., Zachow, S., Weinans, H., & ZADPOOR, A. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.008 · Cited by 21
“The ‘apparent density’ of bone was related to the elastic modulus of bone using the well-established density–modulus relationship proposed by Morgan et al. (2003).”
MethodA Phenomenological Model for Predicting Fatigue Life in Bovine Trabecular Bone
Ganguly, P., Moore, T. L. A., & Gibson, L. J. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1762893 · Cited by 21
Heyland, M., Trepczynski, A., Duda, G. N., Zehn, M., Schaser, K., & Märdian, S. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.10.002 · Cited by 18
Gustafsson, A., Schilcher, J., Grassi, L., Aspenberg, P., & Isaksson, H. (2016) · Bone · doi:10.1016/j.bone.2016.04.020 · Cited by 19
“Young'smodulus for bonewas calculated for each element based on the radiological density in the CT data [18], and the results were mapped to each respective model (clinical CT and μCT) using Bonemat [20].”
MethodBasaruddin, K. S., TAKANO, N., & Nakano, T. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.785537 · Cited by 21
“2010) and anatomical sites (Ashman et al. 1989; Morgan et al. 2003) on the stiffness of trabecular bone has been discussed in many research works.”
BackgroundDonnell, P. M., Harrison, N. M., Lohfeld, S., Kennedy, O. D., Zhang, Y., & McHugh, P. E. (2009) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2009.03.002 · Cited by 18
“A major benefit of this approach was the fact that it was not necessary to take into account the variables of tissue heterogeneity (Goldstein, 1987, Morgan et al., 2003) and microdamage (Wang and Niebur, 2006, Yeh and Keaveny, 2001) which occur in real bone, thus allowing the effects of…”
BackgroundA new hip epiphyseal prosthesis: Design revision driven by a validated numerical procedure
Martelli, S., Taddei, F., Cristofolini, L., Schileo, E., Rushton, N., & Viceconti, M. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.05.010 · Cited by 18
Yang, L., Parimi, N., ORWOLL, E. S., Black, D., Schousboe, J. T., & Eastell, R. (2017) · Osteoporosis International · doi:10.1007/s00198-017-4319-2 · Cited by 20
Nolte, D., & Bull, A. M. J. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.03.007 · Cited by 18
Chanda, S., Mukherjee, K., Gupta, S., & Pratihar, D. K. (2019) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411919890998 · Cited by 18
Mancuso, M. E., & Troy, K. L. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4048232 · Cited by 21
Biomechanical assessment of orbital fractures using patient-specific models and clinical matching
Darwich, M. A., Attieh, A., Khalil, A.-K., Szávai, S., & Nazha, H. M. (2020) · Journal of Stomatology Oral and Maxillofacial Surgery · doi:10.1016/j.jormas.2020.12.008 · Cited by 18
O’Rourke, D., Beck, B. R., Harding, A. T., Watson, S. L., Pivonka, P., & Martelli, S. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110315 · Cited by 23
Prediction of mechanical properties of trabecular bone using quantitative MRI
Lammentausta, E., Hakulinen, M. A., Jurvelin, J. S., & Nieminen, M. T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/23/017 · Cited by 19
A Novel Morphological Model of Trabecular Bone Based on the Gyroid
Rammohan, A. V., Lee, T., & Tan, V. B. C. (2015) · International Journal of Applied Mechanics · doi:10.1142/s1758825115500489 · Cited by 17
Are DXA/aBMD and QCT/FEA Stiffness and Strength Estimates Sensitive to Sex and Age?
Rezaei, A., Giambini, H., Rossman, T., Carlson, K., Yaszemski, M. J., Lu, L., & Dragomir‐Daescu, D. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1914-5 · Cited by 20
Exploratory Full-Field Strain Analysis of Regenerated Bone Tissue from Osteoinductive Biomaterials
Fernández, M. P., Black, C. R. M., Dawson, J. I., Gibbs, D., Kanczler, J. M., Oreffo, R. O. C., & Tozzi, G. (2020) · Materials · doi:10.3390/ma13010168 · Cited by 19
Synnott, S., Langohr, G. D. G., Reeves, J. M., Johnson, J. A., & Athwal, G. S. (2021) · JSES International · doi:10.1016/j.jseint.2021.05.006 · Cited by 18
Metadata
- Authors
- Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 36
- Issue
- 7
- Pages
- 897-904
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2088873760
- Cited by
- 1,209
- References
- 49
- Citations by year
- 2026: 73 · 2025: 72 · 2024: 79 · 2023: 71 · 2022: 78 · 2021: 99 · 2020: 85 · 2019: 59 · 2018: 56 · 2017: 55 · 2016: 61 · 2015: 55 · 2014: 62 · 2013: 43 · 2012: 37
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, elastic modulus, bone mineral density, bone structure, finite element analysis, vertebrae, proximal tibia, femoral neck, power-law regression, bone mechanical properties
- MeSH terms
- Aged, Bone and Bones, Cadaver, Computer Simulation, Elasticity, Female, Femur, Femur Neck, Humans, Lumbar Vertebrae, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Thoracic Vertebrae, Tibia, Reproducibility of Results, Bone Density, Anisotropy, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›