Trabecular bone modulus–density relationships depend on anatomic site
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
One outstanding issue regarding the relationship between elastic modulus and density for trabecular bone is whether the relationship depends on anatomic site. To address this, on-axis elastic moduli and apparent densities were measured for 142 specimens of human trabecular bone from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27). Specimens were obtained from 61 cadavers (mean+/-SD age=67+/-15 years). Experimental protocols were used that minimized end-artifact errors and controlled for specimen orientation. Tissue moduli were computed for a subset of 18 specimens using high-resolution linear finite element analyses and also using two previously developed theoretical relationships (Bone 25 (1999) 481; J. Elasticity 53 (1999) 125). Resultant power law regressions between modulus and density did depend on anatomic site, as determined via an analysis of covariance. The inter-site differences were among the leading coefficients (p<0.02), but not the exponents (p>0.08), which ranged 1.49-2.18. At a given density, specimens from the tibia had higher moduli than those from the vertebra (p=0.01) and femoral neck (p=0.002); those from the trochanter had higher moduli than the vertebra (p=0.02). These differences could be as large as almost 50%, and errors in predicted values of modulus increased by up to 65% when site-dependence was ignored. These results indicate that there is no universal modulus-density relationship for on-axis loading. Tissue moduli computed using methods that account for inter-site architectural variations did not differ across site (p>0.15), suggesting that the site-specificity in apparent modulus-density relationships may be attributed to differences in architecture.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Items 601–700 of 1,000
Ni, X., Sun, Q. H., Wang, J.-X., Zhang, D., Jin, X. M., Yang, Q., Chen, L., Yang, J., & Hong, Y. (2025) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2025.03.108 · Cited by 17
Evaluation of mesh morphing and mapping techniques in patient specific modelling of the human pelvis
Salo, Z., Beek, M., & Whyne, C. M. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2468 · Cited by 12
“It has been established that the correlation between Young’s modulus (MPa) and bone density is dependent on anatomic location, which can be credited to variations in structure [33].”
BackgroundHernandez, C. J. (2016) · Springer eBooks · doi:10.1007/978-1-4939-3305-1_2 · Cited by 14
Optimizing Accuracy of Proximal Femur Elastic Modulus Equations
Rezaei, A., Carlson, K., Giambini, H., Javid, S., & Dragomir‐Daescu, D. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02238-9 · Cited by 16
Biomechanical modeling of metal screw loadings on the human vertebra
Molinari, L., Falcinelli, C., Gizzi, A., & Martino, A. C. D. (2021) · Acta Mechanica Sinica · doi:10.1007/s10409-021-01063-5 · Cited by 13
Anijs, T., Eemers, S., Minoda, Y., Wolfson, D., Verdonschot, N. J. J., & Janssen, D. W. (2021) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34957 · Cited by 12
“cle tissue(39); linear elastic properties of the calibrated bone densities were subsequently assigned using reported modulus–density relationships of cortical and cancellous bone, respectively.(40,41) Elastic moduli”
MethodMechanical and morphometric characterization of custom-made trabecular bone surrogates
Klinger, S., Greinwald, M., Augat, P., & Hollensteiner, M. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105146 · Cited by 12
Evaluation of suitable porosity for sintered porous β-tricalcium phosphate as a bone substitute
Park, J.-H., Bae, J.-Y., Shim, J.-B., & Jeon, I. (2012) · Materials Characterization · doi:10.1016/j.matchar.2012.06.012 · Cited by 12
Swider, P., Guerin, G. E., Baas, J., Søballé, K., & Bechtold, J. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.04.030 · Cited by 12
“Numerous studies dealing with bone mechanical properties and elasticity–density relationships for cancellous bone have been published (Augat et al., 1998; Kang and Friedman, 1998; Morgan et al., 2003; Helgason et al., 2008).”
BackgroundCampoli, G., Bolsterlee, B., van der Helm, F. C. T., Weinans, H., & ZADPOOR, A. A. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.1146 · Cited by 12
“Young’s modulus was then related to calculated values of apparent density using Morgan’s relationship [41]”
BackgroundMethodLu, Y., & Lekszycki, T. (2018) · Continuum Mechanics and Thermodynamics · doi:10.1007/s00161-018-0650-x · Cited by 11
“Young’s modulus of the mixture could be calculated by the power law model [20,22,26,27],”
MethodSchoell, S. L., Beavers, K. M., Beavers, D. P., Lenchik, L., Marsh, A. P., Rejeski, W. J., Stitzel, J. D., & Weaver, A. A. (2018) · Aging Clinical and Experimental Research · doi:10.1007/s40520-018-1010-1 · Cited by 15
Linear and nonlinear analyses of femoral fractures: Computational/experimental study
Mirzaei, M., Alavi, F., Allaveisi, F., Naeini, V., & Amiri, P. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.08.003 · Cited by 13
Erdem, İ., Truumees, E., & van der Meulen, M. C. H. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.636741 · Cited by 12
“For each model two bone material distributions were simulated: an isotropic homogeneous elastic modulus of 1000 MPa or an isotropic heterogeneous modulus assigned based on an exponential density–elasticity relationship (Morgan et al. 2003).”
Irarrázaval, S., Ramos-Grez, J. A., Perez, L., Besa, P., & Ibáñez, A. (2021) · SN Applied Sciences · doi:10.1007/s42452-021-04760-9 · Cited by 13
Kanaizumi, A., Suzuki, D., Nagoya, S., Teramoto, A., & Yamashita, T. (2022) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-022-03329-5 · Cited by 11
Pivonka, P., Calvo‐Gallego, J. L., Schmidt, S., & Martínez‐Reina, J. (2024) · Bone · doi:10.1016/j.bone.2024.117140 · Cited by 12
Smit, T., Aage, N., Haschtmann, D., Ferguson, S. J., & Helgason, B. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1347961 · Cited by 13
“…analysis of the maximum FFR to different apparent density-to-modulus relationships was performed by calculating the maximum FFR using two alternative relationships, from the study by Kopperdahl and Keaveny (1998) and by Morgan et al. (2003), with all other model parameters kept the same (Table 5).”
MethodCortical and Trabecular Bone Fracture Characterisation in the Vertebral Body Using Acoustic Emission
Robinson, D. L., Tse, K. M., Franklyn, M., Zhang, J., Ackland, D. C., & Lee, P. V. S. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02316-y · Cited by 11
Subject-specific finite element analysis of a lumbar cage produced by electron beam melting
Epasto, G., Distefano, F., Mineo, R., & Guglielmino, E. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02078-8 · Cited by 11
An Equivalent Constitutive Model of Cancellous Bone With Fracture Prediction
Salem, M., Westover, L., Adeeb, S., & Duke, K. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047080 · Cited by 11
Wu, Y., Wang, Y., Liu, M., Shi, D., Hu, N., & Feng, W. (2023) · Metals · doi:10.3390/met13061034 · Cited by 11
Intraosseous monitoring and guiding by ultrasound: A feasibility study
Rosenberg, N., Craft, A., & Halevy-Politch, J. (2013) · Ultrasonics · doi:10.1016/j.ultras.2013.09.008 · Cited by 11
Rundell, S. A., Day, J. S., Isaza, J., Siskey, R. L., MacDonald, D. W., & Kurtz, S. M. (2011) · Journal of ASTM International · doi:10.1520/jai103556 · Cited by 13
Levasseur, A., Ploeg, H., & Petit, Y. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0763-x · Cited by 11
Helgason, B., Stirnimann, P., Widmer, R. P., Böger, A., & Ferguson, S. J. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32847 · Cited by 11
Helgason, B., Stirnimann, P., Widmer, R. P., & Ferguson, S. J. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31886 · Cited by 11
Robinson, D., Jiang, H.-Y., Song, Q.-C., Yates, C., Lee, P., & Wark, J. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-018-1079-7 · Cited by 10
Bahia, M. T., Hecke, M. B., & Mercuri, E. G. F. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.05.005 · Cited by 11
Lü, Y., Yang, Z., & Wang, Y. (2019) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411919865385 · Cited by 11
Li, Z., Song, G., Su, Z., & Wang, G. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.105080 · Cited by 11
Population-based effect of total knee arthroplasty alignment on simulated tibial bone remodeling
Anijs, T., Wolfson, D., Verdonschot, N. J. J., & Janssen, D. W. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104014 · Cited by 13
Trzebiatowski, M. Z., Kłosowski, P., Skorek, A., Żerdzicki, K., Lemski, P., & Koberda, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72186-1 · Cited by 11
Chun, B. J., & Jang, I. G. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105924 · Cited by 11
A systematic approach to the scale separation problem in the development of multiscale models
Bhattacharya, P., Li, Q., Lacroix, D., Kadirkamanathan, V., & Viceconti, M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0251297 · Cited by 14
“Based on experimental and computational evidence [40,41], the elasticity of the bone material at any location within O is assumed to depend on the local vBMD ρ H 1⁄4 hðrÞ ð2Þ”
BackgroundSoni, A., Kumar, S., & Kumar, N. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106820 · Cited by 11
Nanoscale Stiffness Distribution in Bone Metastasis
Richert, L., Keller, L., Wagner, Q., Bornert, F., Gros, C. P., Bahi-Gross, S., Clauss, F., Bacon, W., Clézardin, P., Benkirane-Jessel, N., et al. (2015) · World Journal of Nano Science and Engineering · doi:10.4236/wjnse.2015.54023 · Cited by 12
“At the macroscopic level, considerable variations in mechanical properties have been detected for different tissues locations [8], as well as for regions within a specific location [9].”
BackgroundEstimation of Local Bone Loads for the Volume of Interest
Kim, J. J., Kim, Y., & Jang, I. G. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4033478 · Cited by 11
Post-yield relaxation behavior of bovine cancellous bone
Burgers, T. A., Lakes, R. S., García-Rodríguez, S., Piller, G. R., & Ploeg, H.-L. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.005 · Cited by 10
“The elastic modulus of cancellous bone in the pre-yield region is obviously not related to strain, but is related through a power law relation with apparent density, for example (Carter and Hayes, 1977; Kopperdahl et al., 2002; Morgan et al., 2003).”
BackgroundZhang, M., Gong, H., & Zhang, M. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25334 · Cited by 10
“The elastic and plastic properties of each material were assigned based on the proposed empirical relationships (Supporting Information Appendix 1).(26,27) The material property of PMMA was set as isotropic linear elastic (E MPa = 2500 , v = 0.”
MethodYang, A., Mao, W., Chang, S., He, Y., Li, L., Li, H., Long, F., & Dong, Y.-H. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106830 · Cited by 10
Biomechanical Aspects in Bone Tumor Engineering
Menshikh, K. A., Banićević, I., Obradović, B., & Rimondini, L. (2024) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2023.0106 · Cited by 13
Kechagias, S., Theodoridis, K., Broomfield, J., Malpartida-Cardenas, K., Reid, R., Georgiou, P., van Arkel, R. J., & Jeffers, J. R. T. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1305936 · Cited by 10
Gibson, F. G., Paggiosi, M., Handforth, C., Brown, J. E., Li, X., Dall’Ara, E., & Verbruggen, S. W. (2025) · Bone · doi:10.1016/j.bone.2025.117465 · Cited by 12
“(1) and (2)] [32,33] (Fig.”
Fractional-order viscoelastic model for tendons with multilevel self-similar structures
Wang, X., & Guo, J. (2025) · Applied Mathematical Modelling · doi:10.1016/j.apm.2025.116222 · Cited by 12
Soltanmohammadi, P., Tavakoli, A., Langohr, G. D. G., Athwal, G. S., & Willing, R. T. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25076 · Cited by 10
Rezaei, A., Tilton, M., Li, Y., Yaszemski, M. J., & Lu, L. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104833 · Cited by 11
González, F. J. Q., Sculco, P. K., Kahlenberg, C. A., Mayman, D. J., Lipman, J. D., Wright, T. M., & Vigdorchik, J. M. (2022) · The Journal of Arthroplasty · doi:10.1016/j.arth.2022.10.032 · Cited by 10
Irradiation Does Not Modify Mechanical Properties of Cancellous Bone Under Compression
Hernandez, C. J., Ramsey, D. S., Dux, S. J., Chu, E. H., & Rimnac, C. M. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-2148-8 · Cited by 10
“Previous studies have shown the coefficients defining the relationship between yield strength and density [29], elastic modulus and density [28] as well as yield strain display standard deviations of 11% of the mean.”
BackgroundHortin, M. S., & Bowden, A. E. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1159677 · Cited by 12
Stricker, A., Widmer, D., Gueorguiev, B. G., Wahl, D., Varga, P., & Duttenhoefer, F. (2018) · BioMed Research International · doi:10.1155/2018/3579654 · Cited by 10
“49 for trabecular bone [19] E[Gpa] = 10.”
Stochastic analysis of a heterogeneous micro-finite element model of a mouse tibia
Lü, Y., Zuo, D., Li, J., & He, Y. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.10.007 · Cited by 10
Stress Shielding in Cemented Hip Implants Assessed from Computed Tomography
Goswami, T. (2019) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2019.18.003163 · Cited by 10
Harnroongroj, T., Volpert, L., Ellis, S. J., Sofka, C. M., Deland, J. T., & Demetracopoulos, C. A. (2019) · Foot & Ankle International · doi:10.1177/1071100719868496 · Cited by 11
“Therefore, the calculations of strength and stiffness were not always straightforwardly correlated with the power of 2 and 3.(18,22,23,26) Thus, in this study, we decided not to convert our HU value into strength and stiffness as there was no definite conclusion of these correlations and might lead to error.”
Muralidharan, L., Cardiff, P., Fitzgerald, K., Flavin, R., & Ivankoviç, A. (2020) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411920932687 · Cited by 10
Lattice implants that generate homeostatic and remodeling strains in bone
Munford, M. J., Xiao, D., & Jeffers, J. R. T. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25114 · Cited by 10
Abe, S., Kouhia, R., Nikander, R., Narra, N., Hyttinen, J., & Sievänen, H. T. (2022) · Bone · doi:10.1016/j.bone.2022.116351 · Cited by 12
Bone Remodeling Around Solid and Porous Interbody Cages in the Lumbar Spine
Talukdar, R. G., Saviour, C. M., Tiwarekar, K., Dhara, S., & Gupta, S. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4054457 · Cited by 11
Rayudu, N. M., Subburaj, K., Elara, M. R., Sollmann, N., Dieckmeyer, M., Kirschke, J. S., & Baum, T. H. (2022) · Biomedicines · doi:10.3390/biomedicines10071567 · Cited by 14
“Elastic modulus (E in MPa) [34,36] Ez = 4730 × (ρapp)1.”
Sensitivity analysis of a cemented hip stem to implant position and cement mantle thickness
Shi, J., Browne, M., Strickland, M. A., Flivik, G., & Taylor, M. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.761693 · Cited by 10
“Young’s modulus was then derived from bone apparent density (Morgan et al. 2003).”
MethodTrần, T. N., Kowalczyk, W., Hohn, H. P., Jäger, M., & Landgraeber, S. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.05.008 · Cited by 10
Eidel, B., Gote, A., Ohrndorf, A., & Christ, H. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.04.016 · Cited by 9
Bone Quality: The Mechanical Effects of Microarchitecture and Matrix Properties
Day, J. S. (2005) · EUR Research Repository (Erasmus University Rotterdam) · Cited by 16
CT-Based Bone and Muscle Assessment in Normal and Pathological Conditions
Gargiulo, P., Gíslason, M. K., Edmunds, K. J., Pitocchi, J., Carraro, U., Esposito, L., Fraldi, M., Bifulco, P., Cesarelli, M., & Jónsson, H. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99920-3 · Cited by 11
Liu, Y., Zheng, L., Li, S., Zhang, Z., Lin, Z., & Ma, W. (2024) · Scientific Reports · doi:10.1038/s41598-024-61122-2 · Cited by 10
“It is well-known that site-specific differences in bone structure significantly influence the material properties of human trabecular bone 38,39 ; (2) Random error may have occurred due to a small sample size (n = 4); and (3) The loading and boundary directions were completely reversed.”
BackgroundRouyin, A., Nazemi, H., Arjmand, N., & Einafshar, M. M. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109290 · Cited by 9
Fita, S. W., Bonek, M., Woźniak, A., & Sławski, S. (2025) · Materials · doi:10.3390/ma18235421 · Cited by 11
“From those papers, it is shown that titanium scaffolds can mimic human cancellous bone [144,145,153,189].”
InfluentialKechagias, S., Munford, M. J., Masure, F. C. H., van Arkel, R. J., & Oosterbeek, R. N. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202501885 · Cited by 15
Naseri, A. B., Dunbar, N. J., Baines, A. J., Akin, J. E., Higgs, C. F., & Fregly, B. J. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.07.012 · Cited by 9
Khakpour, S., Esrafilian, A., Tanska, P., Mononen, M. E., Korhonen, R. K., & Jämsä, T. J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263458 · Cited by 13
“[38], the elastic modulus was calculated for each element.”
BackgroundInacio, J. V., Schwarzenberg, P., Yoon, R. S., Kantzos, A., Malige, A., Nwachuku, C. O., & Dailey, H. L. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4053875 · Cited by 9
Structural features of subchondral bone cysts and adjacent tissues in hip osteoarthritis
Nakasone, A., Guang, Y., Wise, A., Kim, L., Babbin, J., Rathod, S., Mitchell, A. J., Gerstenfeld, L. C., & Morgan, E. F. (2022) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2022.03.013 · Cited by 9
Self-citationHuang, X., Zheng, L., Zheng, D., Li, S., Fan, Y., Lin, Z., & Huang, S. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1061758 · Cited by 10
“In actual bone samples, tissue modulus and strength appear to be linear within a single anatomic site but to be power-law across multiple sites because of the differentiation of apparent density (r in g/cm(3)) and BV/TV (30, 35).”
BackgroundJyoti, J., & Ghosh, R. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108645 · Cited by 9
Establishment and verification of a non-linear finite element model for human L4–L5 lumbar segment
Xiao, Z., Wang, L., Gong, H., Gao, J., & Zhang, X. (2010) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2010.5639592 · Cited by 9
The Relevance of Biomechanical Analysis in Joint Replacements: A Review
Pal, B., & Gupta, S. (2020) · Journal of The Institution of Engineers (India) Series C · doi:10.1007/s40032-020-00611-5 · Cited by 9
Trends in the Characterization of the Proximal Humerus in Biomechanical Studies: A Review
Castro-Franco, A. D., Mendoza-Muñoz, I., González-Ángeles, Á., Cruz-Sotelo, S. E., Castañeda, A. M., & Siqueiros-Hernández, M. (2020) · Applied Sciences · doi:10.3390/app10186514 · Cited by 9
“[61], where the ρ (gHA/cm3) is the equivalent density to the BMD value obtained from the QTC, as seen in Equation (2).”
MethodEmerzian, S. R., Wu, T., Vaidya, R., Tang, S. Y., Abergel, R. J., & Keaveny, T. M. (2023) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.4828 · Cited by 13
“347 366 (68) 270 (51) 466 (78) 336 (54) Stiffness (kN/mm) 0.”
Self-citationPatient‐Specific Finite Element Modelling and Validation of Porcine Femora in Torsion
Emerson, N., Offiah, A. C., Reilly, G. C., & Carré, M. (2013) · Strain · doi:10.1111/str.12029 · Cited by 9
“used during simulation to confirm the simulation accuracy provided by each [20-22].”
MethodChristen, D., Zwahlen, A., & Müller, R. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.10.010 · Cited by 10
Initial fixation of a femoral knee component: an in vitro and finite element study
Burgers, T., Mason, J., & Ploeg, H. (2009) · International Journal of Experimental and Computational Biomechanics · doi:10.1504/ijecb.2009.022857 · Cited by 10
The effect of oligo(trimethylene carbonate) addition on the stiffness of acrylic bone cement
Persson, C., López, A., Fathali, H. M., Hoess, A., Rojas, R., Ott, M. K., Hilborn, J. G., & Engqvist, H. (2016) · Biomatter · doi:10.1080/21592535.2015.1133394 · Cited by 9
Vijayakumar, V., & Quenneville, C. E. (2016) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411916642800 · Cited by 9
“It has been shown previously that more accurate results arise from the use of site-specific equations,(8,9) with several density–modulus relationships having been developed for cancellous bone of the proximal tibia.(7,10,11) However, great differences in the coefficients and exponents exist for each equation, and it i…”
BackgroundMethodSheehan, F. T., Brainerd, E. L., Troy, K. L., Shefelbine, S. J., & Ronsky, J. L. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0368-9 · Cited by 10
Al‐Dirini, R. M. A., Martelli, S., & Taylor, M. (2019) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-019-01235-0 · Cited by 9
Gehweiler, D., Schultz, M., Schulze, M., Riesenbeck, O., Wähnert, D., & Raschke, M. C. E. J. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04571-4 · Cited by 8
“were able to show that the correlation between bone density and elastic modulus is dependent on anatomical positions and the prediction error can rise above 60% if this distinction is ignored [7].”
BackgroundGreve, T., Rayudu, N. M., Dieckmeyer, M., Boehm, C., Ruschke, S., Burian, E., Kloth, C., Kirschke, J. S., Karampinos, D. C., Baum, T. H., et al. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.900356 · Cited by 9
“6 × rapp Elastic modulus (E in MPa) (51, 53) Ez = 4730 × (rapp) Ex= Ey = 0.”
InfluentialA novel design of hip-stem with reduced strain-shielding
Loha, T., Bhattacharya, R., Pal, B., & Amis, A. A. (2024) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119241244537 · Cited by 8
“Experimental studies 41,42 have established a power-law relationship between r and elastic modulus (E), and E = 7281 r 1.52 has been used in previous FE studies of the femur.”
MethodInfluentialA comparison of density–modulus relationships used in finite element modeling of the shoulder
Knowles, N. K., Langohr, G. D. G., Faieghi, R., Nelson, A. J., & Ferreira, L. M. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.02.005 · Cited by 9
Rayudu, N. M., Baum, T. H., Kirschke, J. S., & Subburaj, K. (2021) · Materials · doi:10.3390/ma14195791 · Cited by 9
Geometry and bone mineral density determinants of femoral neck strength changes following exercise
O’Rourke, D., Beck, B. R., Harding, A. T., Watson, S. L., Pivonka, P., & Martelli, S. (2022) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-022-01642-w · Cited by 13
“An empirical relationship was used to convert the density (g/cm3) in the images to elastic modulus (MPa) (Morgan et al. 2003) with a correction for bone ash density (Schileo et al.”
MethodJung, C.-H., Cha, Y., Chung, J. Y., Park, C. H., Kim, T. Y., Yoo, J., Kim, J.-T., & Jeon, Y. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06579-4 · Cited by 8
“[24, 25] The mapping method encompasses matching the values from the CT HU to ash density, from ash density to apparent density, and from apparent bone density to Young’s modulus.”
MethodEffects of loading rate, age, and morphology on the material properties of human rib trabecular bone
Albert, D. L., Katzenberger, M. J., Hunter, R. L., Agnew, A. M., & Kemper, A. R. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111670 · Cited by 9
Gersie, T., Bitter, T., Wolfson, D., Freeman, R., Verdonschot, N. J. J., & Janssen, D. W. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106434 · Cited by 10
Roux, J.-P., Duboeuf, F., Sornay‐Rendu, E., Rinaudo, L., Ulivieri, F. M., Wegrzyn, J., & Chapurlat, R. D. (2024) · Osteoporosis International · doi:10.1007/s00198-024-07066-9 · Cited by 12
“This tool represents the analysis of a deformation index that is obtained by the use of finite element analysis (FEA) from DXA images, and it is consistent with the mathematical model called Finite Element Model [13].”
Sztrinkai, G. (2014) · Joint Diseases and Related Surgery · doi:10.5606/ehc.2014.03 · Cited by 8
“In the literature, the elastic modulus (Young’s modulus) is calculated from the density values gained from the CT-scans.[15-18] As we already mentioned above, an accurate density-elasticity correlation concerning the pelvic bone is not known yet, it has only been determined with indirect methods.”
BackgroundMethodInfluentialAlexander, S. L., Gunnarsson, C. A., & Weerasooriya, T. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.04.010 · Cited by 8
Knowles, N. K., Kusins, J. R., Columbus, M. P., Athwal, G. S., & Ferreira, L. M. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24482 · Cited by 9
“, Natick, MA) directly for the linear regression fits, and on the log‐transformed data of the power–law regression fits.(11)”
BackgroundResultLi, Z., Wang, J., Song, G., Ji, C., & Han, X. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.105279 · Cited by 8
Ziaeipoor, H., Taylor, M., & Martelli, S. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02483-3 · Cited by 9
Metadata
- Authors
- Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 36
- Issue
- 7
- Pages
- 897-904
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2088873760
- Cited by
- 1,209
- References
- 49
- Citations by year
- 2026: 73 · 2025: 72 · 2024: 79 · 2023: 71 · 2022: 78 · 2021: 99 · 2020: 85 · 2019: 59 · 2018: 56 · 2017: 55 · 2016: 61 · 2015: 55 · 2014: 62 · 2013: 43 · 2012: 37
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, elastic modulus, bone mineral density, bone structure, finite element analysis, vertebrae, proximal tibia, femoral neck, power-law regression, bone mechanical properties
- MeSH terms
- Aged, Bone and Bones, Cadaver, Computer Simulation, Elasticity, Female, Femur, Femur Neck, Humans, Lumbar Vertebrae, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Thoracic Vertebrae, Tibia, Reproducibility of Results, Bone Density, Anisotropy, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.