Trabecular bone modulus–density relationships depend on anatomic site
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
One outstanding issue regarding the relationship between elastic modulus and density for trabecular bone is whether the relationship depends on anatomic site. To address this, on-axis elastic moduli and apparent densities were measured for 142 specimens of human trabecular bone from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27). Specimens were obtained from 61 cadavers (mean+/-SD age=67+/-15 years). Experimental protocols were used that minimized end-artifact errors and controlled for specimen orientation. Tissue moduli were computed for a subset of 18 specimens using high-resolution linear finite element analyses and also using two previously developed theoretical relationships (Bone 25 (1999) 481; J. Elasticity 53 (1999) 125). Resultant power law regressions between modulus and density did depend on anatomic site, as determined via an analysis of covariance. The inter-site differences were among the leading coefficients (p<0.02), but not the exponents (p>0.08), which ranged 1.49-2.18. At a given density, specimens from the tibia had higher moduli than those from the vertebra (p=0.01) and femoral neck (p=0.002); those from the trochanter had higher moduli than the vertebra (p=0.02). These differences could be as large as almost 50%, and errors in predicted values of modulus increased by up to 65% when site-dependence was ignored. These results indicate that there is no universal modulus-density relationship for on-axis loading. Tissue moduli computed using methods that account for inter-site architectural variations did not differ across site (p>0.15), suggesting that the site-specificity in apparent modulus-density relationships may be attributed to differences in architecture.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Items 501–600 of 1,000
Li, Z., Liu, P., Yuan, Y., Liang, X., Lei, J., Zhu, X., Zhang, Z., & Cai, L. (2021) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-021-01491-z · Cited by 18
Xu, C., Huang, C., Cai, P., Fang, Z., Wei, Z., Liu, F., Li, J., & Liu, Y. (2022) · International Journal of General Medicine · doi:10.2147/ijgm.s352304 · Cited by 17
El-Garaihy, W. H., Alateyah, A. I., Ahmed, M. M. Z., El‐Asfoury, M. S., Alawad, M. O., BaQais, A., Zedan, Y., & Salem, H. G. (2024) · Metals and Materials International · doi:10.1007/s12540-023-01599-0 · Cited by 18
Biomechanics of the Human Osteochondral Unit: A Systematic Review
Berni, M., Marchiori, G., Baleani, M., Giavaresi, G., & Lopomo, N. F. (2024) · Materials · doi:10.3390/ma17071698 · Cited by 27
“Tensile [146] and ultrasound [145] measurements are also proposed, the latter providing an estimate of the elastic modulus reasonably correlated to the one assessed using the compressive technique [145].”
BackgroundMethodDeng, T., Gong, S., Cheng, Y., Wang, J., Zhang, H., Li, K., Nie, Y., & Shen, B. (2024) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-024-05006-1 · Cited by 17
“83 MPa , was chosen to assign Young’s modulus of trabecular bone with Poisson’s ratio of 0.2 [26, 27].”
MethodInfluentialSoodmand, I., Becker, A.-K., Saß, J., Jabs, C., Kebbach, M., Wanke, G., Dau, M., & Bader, R. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e40668 · Cited by 22
Väänänen, S. P., Isaksson, H., Julkunen, P., Sirola, J. P., Kröger, H., & Jurvelin, J. S. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0253-3 · Cited by 16
“The Hounsfield values were mapped to the K2HPO4 values using the phantom calibration from the CT imaging, and the K2HPO4 values were converted to Young’s modulus (Morgan et al. 2003).”
MethodNovel injectable biomaterials for bone augmentation based on isosorbide dimethacrylic monomers
Łukaszczyk, J., Janicki, B., López, A., Skołucka-Szary, K., Wojdyła, H., Persson, C., Piaskowski, S., & Śmiga‐Matuszowicz, M. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.03.046 · Cited by 17
Vivanco, J. F., Burgers, T., García-Rodríguez, S., Crookshank, M. C., Kunz, M., MacIntyre, N. J., Harrison, M. M., Bryant, J. T., Sellens, R., & Ploeg, H. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914540285 · Cited by 22
Rahchamani, R., & Soheilifard, R. (2019) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2019.1661387 · Cited by 17
“The Young’s moduli (E in MPa) of the bone elements were related to the apparent density as (Morgan et al. 2003) E ¼ 7281q1:52 (2) The initial design of the stem was generated in SolidWorks CAD package (SolidWorks, Dassault Systemes S.A.) based on a model of the collarless TriLock DePuy Synthes…”
BackgroundMethodLange, H.-E., Hohlfeld, D., Bader, R., & Kluess, D. (2020) · Smart Materials and Structures · doi:10.1088/1361-665x/abba6e · Cited by 17
Yan, C., Bice, R. J., Frame, J. W., Warden, S. J., & Kersh, M. E. (2021) · Bone · doi:10.1016/j.bone.2022.116392 · Cited by 18
A Variation of Particle Swarm Optimization for Training of Artificial Neural Networks
Zamani, M., & Sadeghi, A. (2010) · InTech eBooks · doi:10.5772/7819 · Cited by 17
Micro-computed tomography and compressive characterization of trabecular bone
Vale, A. C., Pereira, M. F. C., Maurício, A., Amaral, P. M., Rosa, L. G., Lopes, A. G. B., Rodrigues, A. M., Caetano‐Lopes, J., Vidal, B., Monteiro, J., et al. (2013) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2013.01.057 · Cited by 21
Biomechanical implications of lumbar spinal ligament transection
Forell, G. A. V., & Bowden, A. E. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.763936 · Cited by 17
“Bone mineral densities were correlated with anisotropic tissue moduli through the use of quantitative relationships previously reported by Morgan et al. (2003) and Ulrich et al. (1999).”
MethodParametric Analysis of Orthopedic Screws in Relation to Bone Density
Zanetti, E. M. (2009) · The Open Medical Informatics Journal · doi:10.2174/1874431100903010019 · Cited by 17
p-FEMs in biomechanics: Bones and arteries
Yosibash, Z. (2012) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2012.09.006 · Cited by 19
“[22, 23, 24, 25, 26].”
A novel training-free method for real-time prediction of femoral strain
Ziaeipoor, H., Taylor, M., Pandy, M. G., & Martelli, S. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.01.057 · Cited by 16
Wang, Y., Yamako, G., Okada, T., Arakawa, H., Nakamura, Y., & Chosa, E. (2021) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-021-02614-z · Cited by 18
Subject-specific modeling of the scapula bone tissue adaptation
Campoli, G., Weinans, H., van der Helm, F. C. T., & ZADPOOR, A. A. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.024 · Cited by 19
“The mechanical properties were based on the following correlation between the apparent density and elastic modulus (Morgan et al., 2003):”
BackgroundHasegawa, M., ADACHI, T., & Takano‐Yamamoto, T. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2015.1042463 · Cited by 16
Examining trabecular morphology and chemical composition of peri-scaffold osseointegrated bone
Lyu, L., Yang, S., Ye, J., Zhang, C., & Wang, J. (2020) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-020-01931-z · Cited by 16
Medial Opening Wedge High Tibial Osteotomy in Knee Osteoarthritis—A Biomechanical Approach
Cofaru, N. F., Roman, M. D., Cofaru, I. I., Oleksik, V. S., & Fleacă, R. S. (2020) · Applied Sciences · doi:10.3390/app10248972 · Cited by 16
“83 [42] for a trabecular bone subjected to a compression load.”
BackgroundHennicke, N. S., Saemann, M., Kluess, D., Bader, R., & Sander, M. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.105059 · Cited by 16
Humeral short stem varus–valgus alignment affects bone stress
Tavakoli, A., Spangenberg, G. W., Reeves, J. M., Faber, K. J., & Langohr, G. D. G. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25239 · Cited by 18
Sensitivities of biomechanical assessment methods for fracture healing of long bones
Chen, G., Wu, F. Y., Zhang, J. Q., Zhong, G., & Liu, F. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.04.006 · Cited by 16
Finite element simulation of bone remodelling in the human mandible surrounding dental implant
Lian, Z., Guan, H., Ivanovski, S., Loo, Y., Johnson, N. W., & Zhang, H. (2010) · Acta Mechanica · doi:10.1007/s00707-010-0409-3 · Cited by 16
“Some empirical relationships between apparent density and mechanical properties of bone have been established experimentally [28-31].”
BackgroundInfluence of Screw Length and Bone Thickness on the Stability of Temporary Implants
Fernandes, D. J., Elias, C. N., & Ruellas, A. C. D. O. (2015) · Materials · doi:10.3390/ma8095322 · Cited by 16
“Combining this statement of bone stiffness and density with the anisotropic comportment of trabecular bone when loaded with multiaxial loads in vivo [29], our experimental data of insertion torque should be considered might sensitive to bone tissue density.”
BackgroundYuan, J., & Chen, W. (2017) · Applied Mathematics and Mechanics · doi:10.1007/s10483-017-2187-6 · Cited by 16
Yang, S., Luo, Y., Yang, L., Dall’Ara, E., Eastell, R., Goertzen, A. L., McCloskey, E. V., Leslie, W. D., & Lix, L. M. (2018) · Bone · doi:10.1016/j.bone.2018.03.005 · Cited by 16
Comparison of femur stiffness measured from DXA and QCT for assessment of hip fracture risk
Luo, Y., & Yang, H. (2018) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-018-0926-z · Cited by 19
Barth, J. R. H., Garret, J., Geais, L., Bothorel, H., Saffarini, M., & Godenèche, A. (2019) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-019-0178-4 · Cited by 19
Haider, I. T., Simonian, N., Schnitzer, T. J., & Edwards, W. B. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02606-w · Cited by 15
On the human vertebra computational modeling: a literature review
Molinari, L., & Falcinelli, C. (2021) · Meccanica · doi:10.1007/s11012-021-01452-x · Cited by 19
“[61] developed two different power laws for the relation between E and qapp.”
BackgroundMethodInfluentialKumar, A., Mondal, S. K., & Ghosh, R. (2022) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119221113698 · Cited by 15
“In the case of the heterogeneous material model of cancellous bone, stress is not a clear indicator of potential causes of failure as the yielding of the cancellous bone varies largely with the anatomic location.(33) Therefore, no failure of cortical and cancellous bone was predicted from this study.”
BackgroundEndplate volumetric bone mineral density biomechanically matched interbody cage
Weng, Y., Di, M., Wu, T., Ma, X., Yang, Q., & Lu, W. W. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1075574 · Cited by 16
“Although the relationship between spinal endplate cortical QCT-BMD and its compressive elastic modulus is undetermined, some research has summarized relevant theories covering most of the EP-vBMD region (200–500 mg/cc) (Keyak et al., 1994; Morgan et al., 2003).”
BackgroundShear stress in the medial meniscus posterior root during daily activities
Yokoe, T., Ouchi, K., Yamaguchi, Y., Enzaki, M., Tajima, T., & Chosa, E. (2023) · The Knee · doi:10.1016/j.knee.2023.06.008 · Cited by 15
Yue, W., Xu, R., Sui, F., Gao, Y., & Lin, L. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202401159 · Cited by 16
Lee, C.-H., Landham, P. R., Eastell, R., Adams, M. A., Dolan, P., & Yang, L. (2017) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411917708806 · Cited by 17
“Values for the ultimate stress limit su, yield strain limit ey, and ultimate strain limit eu of the vertebra were assigned from the literature.(3,36,39) Poisson’s ratios n of 0.”
MethodDevelopment of a validated glenoid trabecular density-modulus relationship
Knowles, N. K., Langohr, G. D. G., Faieghi, R., Nelson, A. J., & Ferreira, L. M. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.10.013 · Cited by 15
Kok, J., Grassi, L., Gustafsson, A., & Isaksson, H. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110445 · Cited by 15
Towards an App to Estimate Patient-Specific Perioperative Femur Fracture Risk
Esposito, L., Minutolo, V., Gargiulo, P., Jónsson, H., Gíslason, M. K., & Fraldi, M. (2020) · Applied Sciences · doi:10.3390/app10186409 · Cited by 15
“The material properties and the geometry of the sample specimen were obtained from a young patient [37]; the εY < εVM < εult LOW RISK OF FRACTURE”
BackgroundInfluentialFabric dependence of bone ultrasound.
Cowin, S. C., & Cardoso, L. (2010) · PubMed · Cited by 17
High Rotation Rate Behavior of Cervical Spine Segments in Flexion and Extension
Barker, J. B., Cronin, D. S., & Chandrashekar, N. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4028107 · Cited by 17
Butz, K. D., Merrell, G. A., & Nauman, E. A. (2012) · Hand · doi:10.1007/s11552-012-9430-4 · Cited by 14
“The modulus of the cortical bone was varied from 16.5 to 20.5 GPa, and that of the cartilage was allowed to range from 0.5 to 2.0 MPa.”
BackgroundInfluentialIchikawa, J., Hara, T., Tamatsu, Y., & Ide, Y. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.016 · Cited by 15
Peleg, E., Beek, M., Joskowicz, L., Liebergall, M., Mosheiff, R., & Whyne, C. M. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.06.033 · Cited by 17
“(2) E¼ 6950r1:49app (Morgan et al., 2003); and Eq.”
InfluentialChanda, S., Gupta, S., & Pratihar, D. K. (2015) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-015-1382-1 · Cited by 14
A Three-Dimensional Finite Element Analysis of Displaced Intra-Articular Calcaneal Fractures
Xu, C., Liu, H., Li, M., Wang, C., & Li, K. (2017) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2016.09.018 · Cited by 15
“The bones were assigned inhomogeneous linearly isotropic material properties according to previously established density–elasticity relationships (22,23): E1⁄4 8920 rapp 1.”
BackgroundMancuso, M. E., Johnson, J. E., Ahmed, S., Butler, T. A., & Troy, K. L. (2018) · Bone Reports · doi:10.1016/j.bonr.2018.04.001 · Cited by 16
Abe, S., Narra, N., Nikander, R., Hyttinen, J., Kouhia, R., & Sievänen, H. T. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.05.037 · Cited by 17
“By converting this vBMD value to the Young’s modulus using equations found in literature (Morgan et al., 2003; Schileo et al., 2014, 2008a), a Young’s modulus of about 2600 MPa is yielded, which is”
MethodJang, C.-Y., Bang, S.-H., Kim, W., Lee, S., Lee, H., Kwak, D.-K., & Yoo, J. (2019) · Injury · doi:10.1016/j.injury.2019.08.014 · Cited by 15
Jiang, H., Robinson, D. L., Yates, C. J., Lee, P. V. S., & Wark, J. D. (2019) · Osteoporosis International · doi:10.1007/s00198-019-05213-1 · Cited by 17
Wu, C., Wang, C., & Shyu, Y. L. (2011) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3182185aeb · Cited by 15
Jonnala, U. K., Kumar, Y. R., Gibson, I., & Panwisawas, C. (2025) · Materials & Design · doi:10.1016/j.matdes.2025.114938 · Cited by 14
Yi, W., Feng, W., Li, G., Li, Z., Liu, Z., Cheng, X., & Yang, H. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.05.008 · Cited by 15
Bianchi, D., Falcinelli, C., Molinari, L., Gizzi, A., & Martino, A. C. D. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11102850 · Cited by 14
“[35], whereas the relationship in Equation (4b) was taken from [25,26].”
Mechanical Biomarkers in Bone Using Image-Based Finite Element Analysis
Dailey, H. L., Kersh, M. E., Collins, C. J., & Troy, K. L. (2023) · Current Osteoporosis Reports · doi:10.1007/s11914-023-00784-9 · Cited by 17
Cha, Y., Chung, J. Y., Jung, C.-H., Kim, J., Lee, J., Yoo, J., Kim, J.-T., & Jeon, Y. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06631-3 · Cited by 14
“[22, 23], which includes assigning the ash density according to the CT Hounsfield unit.”
BackgroundMethodMcDonnell, P., Harrison, N. M., & McHugh, P. E. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.02.005 · Cited by 16
Effective property estimates for heterogeneous materials with cocontinuous phases
Franciosi, P., Brenner, R., & Omri, A. E. (2011) · Journal of mechanics of materials and structures · doi:10.2140/jomms.2011.6.729 · Cited by 14
Young's Modulus and Load Complexity: Modeling Their Effects on Proximal Femur Strain
Sylvester, A. D., & Kramer, P. A. (2018) · The Anatomical Record · doi:10.1002/ar.23796 · Cited by 15
Lü, L.-W., Meng, G., Gong, H., Zhu, D., Gao, J., & Fan, Y. (2015) · Acta Mechanica Sinica · doi:10.1007/s10409-015-0414-9 · Cited by 14
“density is shown as follows [27,28].”
Peleg, E., Herblum, R., Beek, M., Leo Joskowicz, B., Liebergall, M., Mosheiff, R., & Whyne, C. M. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.673595 · Cited by 14
“In this material assignment approach, the HU field is transformed into a Young’s modulus field utilising the emperical density-based elasticity relationship presented by Morgan et al. (2003), E ¼ 6950r1:49app .”
MethodBiomechanical evaluation of a spherical lumbar interbody device at varying levels of subsidence
Rundell, S. A., Isaza, J., & Kurtz, S. M. (2011) · SAS Journal · doi:10.1016/j.esas.2010.12.001 · Cited by 14
Material growth in thermoelastic continua: Theory, algorithmics, and simulation
Vignes, C., & Papadopoulos, P. (2009) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.11.006 · Cited by 15
“The density value is based on experimental measurements in the femoral neck and the Lamé constants follow from a power-law regression [50].”
MethodDickinson, A., Taylor, A. C., & Browne, M. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim679 · Cited by 14
Robust Design for Acetabular Cup Stability Accounting for Patient and Surgical Variability
Ong, K. L., Santner, T. J., & Bartel, D. L. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2907764 · Cited by 14
Use of finite element analysis to assess bone strength
Morgan, E. F., & Bouxsein, M. (2005) · BoneKEy-Osteovision · doi:10.1138/20050187 · Cited by 15
Self-citationGreybe, D. G., Boland, M. R., Wu, T., & Mithraratne, K. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2790 · Cited by 13
Elastic Modulus of Osteoporotic Mouse Femur Based on Femoral Head Compression Test
Chon, C.-S., Yun, H., Kim, H. S., & Ko, C. (2017) · Applied Bionics and Biomechanics · doi:10.1155/2017/7201769 · Cited by 17
Schoell, S. L., Weaver, A. A., Beavers, D. P., Lenchik, L., Marsh, A. P., Rejeski, W. J., Stitzel, J. D., & Beavers, K. M. (2018) · Journal of Osteoporosis and Physical Activity · doi:10.4172/2329-9509.1000213 · Cited by 15
“which has been shown to produce accurate results in strain prediction for subject-specific FE models [17,22] using Eq.”
MethodKnowles, N. K., Kusins, J. R., Faieghi, R., Ryan, M. K., Dall’Ara, E., & Ferreira, L. M. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02312-2 · Cited by 14
Prado, M., Rezaei, A., & Giambini, H. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02595-w · Cited by 16
Forell, G. A. V., Nelson, T. G., Samartzis, D., & Bowden, A. E. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027301 · Cited by 14
Miller, R. M., Beavers, D. P., Cawthon, P. M., Crotts, C. I., Fanning, J. T., Gerosa, J., Greene, K. A., Hsieh, K. L., Kiel, J., Lawrence, E., et al. (2021) · Contemporary Clinical Trials · doi:10.1016/j.cct.2021.106326 · Cited by 16
Qin, Y., Wang, Q., Shi, C., Liu, B., Ma, S., & Zhang, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-17066-6 · Cited by 13
Wang, F., Metzner, F., Zheng, L., Osterhoff, G., & Schleifenbaum, S. (2022) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-022-03265-4 · Cited by 16
“Meanwhile, human cancellous bone exhibits a high variance in mechanical properties due to the different anatomic sites [19, 20].”
BackgroundUlivieri, F. M., Rinaudo, L., Messina, C., Aliprandi, A., Sconfienza, L. M., Sardanelli, F., & Cesana, B. M. (2022) · La radiologia medica · doi:10.1007/s11547-022-01543-z · Cited by 13
“Such correlations are expected as heavier weight will result in greater bone load and greater strain, while high BMD values reflects a stiffer bone with lower deformation behavior, due to the relationship between density and elastic modulus [33].”
BackgroundCraniocaudal toggling increases the risk of screw loosening in osteoporotic vertebrae
Song, F., Liu, Y., Fu, R., Gao, X., Iqbal, K., Yang, D., Liu, Y., & Yang, H.-S. (2023) · Comput. Methods Programs Biomed. · doi:10.1016/j.cmpb.2023.107625 · Cited by 12
Pradeep, K., & Pal, B. (2023) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119231177346 · Cited by 13
“The Elastic modulus (E) was determined from the apparent density using the empirical relation E=4730r, which has been demonstrated to accurately predict the distribution of elastic moduli in the spine and utilised in other lumbar FE studies.(26) Additionally, a comparable empirical relationship, previously employed by…”
MethodHe, L., Zhao, M., Cheung, J. P. Y., Zhang, T. G., & Ren, X. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106443 · Cited by 16
Huempfner-Hierl, H., Schaller, A., & Hierl, T. (2014) · Head & Face Medicine · doi:10.1186/1746-160x-10-13 · Cited by 13
Giambini, H., Fang, Z., Zeng, H., Camp, J. J., Yaszemski, M. J., & Lu, L. (2016) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2016.0078 · Cited by 13
“There exist several equations relating HU to E, depending on the type of bone (tibia, femur, vertebra) and investigators.(9,27) Equation (3) is a widely used and accepted empirical linear equation associating HU and E for vertebra.”
Modeling, Simulation, Additive Manufacturing, and Experimental Evaluation of Solid and Porous NiTi
Andani, M. T. (2015) · Cited by 13
Estimation of mass apparent density and Young’s modulus of femoral neck-head region
Gujar, R. A., & Warhatkar, H. N. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1799093 · Cited by 13
Mondal, S. K., & Ghosh, R. (2020) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411920967775 · Cited by 13
“Young’s modulus-density relationships were used in this study are given by equations (2) and (3).(27,28)”
MethodXu, C., Huang, C., Cai, P., Fang, Z., Wei, Z., Liu, F., Li, J., & Liu, Y. (2022) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 13
The Importance of Intrinsic Damage Properties to Bone Fragility: A Finite Element Study
Hardisty, M., Zauel, R. R., Stover, S. M., & Fyhrie, D. P. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4023090 · Cited by 14
Fabrication of Porous Ti-rich Ti51Ni49 by Evaporating NaCl Space Holder
Yen, F.-C., Hwang, K.-S., & Wu, S. K. (2014) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-014-2196-2 · Cited by 13
Macroscopic anisotropic bone material properties in children with severe osteogenesis imperfecta
Albert, C., Jameson, J., Tarima, S. S., Smith, P. A., & Harris, G. F. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.09.003 · Cited by 18
Empirical Functions for Conversion of Femur Areal and Volumetric Bone Mineral Density
Luo, Y. (2018) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-018-0394-x · Cited by 13
Al‐Dirini, R. M. A., Martelli, S., Huff, D. N., Ju, Z., Clement, J. G., Besier, T. F., & Taylor, M. (2018) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2018.09.002 · Cited by 13
Yan, Y., Qi, W., Wang, J., Liu, L.-F., Teo, E.-C., Tianxia, Q., Ba, J.-J., & Lei, W. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.01.014 · Cited by 13
“[7] Morgan EF, Bayraktar HH, Keaveny TM.”
BackgroundFinite Element Modeling of the Spine
Bowden, A. E. (2006) · Elsevier eBooks · doi:10.1016/b978-012369390-7/50015-0 · Cited by 13
Biomaterials and Tissue Biomechanics: A Match Made in Heaven?
ZADPOOR, A. A. (2017) · Materials · doi:10.3390/ma10050528 · Cited by 13
Review on the use of medical imaging in orthopedic biomechanics: finite element studies
Barkaoui, A., Oumghar, I. A., & Kahla, R. B. (2021) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2021.1888317 · Cited by 17
Amendola, R. L., Miller, M. A., Kaupp, S. M., Cleary, R. J., Damron, T. A., & Mann, K. A. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06182-7 · Cited by 13
“Isotropic, but heterogeneous material property assignments were assigned to each voxel based on CT mineral density [21] and a Hoffman failure criteria with 0.”
MethodSingh, N. K., Singh, N. K., Verma, R., & Diwan, A. D. (2024) · Bioengineering · doi:10.3390/bioengineering11040344 · Cited by 12
“Equation (1) was used to determine the apparent density (𝜌 The apparent density and modulus equation tailored for vertebrae was used to obtain Young’s modulus Equation (2) [45].”
MethodRaftery, K. A., Kargarzadeh, A., Tavana, S., & Newell, N. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1511685 · Cited by 12
“The power law relation described by Morgan et al. (Equation 1) was subsequently used to convert ρ app to Young ’ s modulus ( E QCT ) (Morgan et al., 2003): Trabecular bone was assumed to behave as an isotropic and elastic material under assumptions made by in fi nitesimal strain theory, which…”
Metadata
- Authors
- Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 36
- Issue
- 7
- Pages
- 897-904
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2088873760
- Cited by
- 1,209
- References
- 49
- Citations by year
- 2026: 73 · 2025: 72 · 2024: 79 · 2023: 71 · 2022: 78 · 2021: 99 · 2020: 85 · 2019: 59 · 2018: 56 · 2017: 55 · 2016: 61 · 2015: 55 · 2014: 62 · 2013: 43 · 2012: 37
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, elastic modulus, bone mineral density, bone structure, finite element analysis, vertebrae, proximal tibia, femoral neck, power-law regression, bone mechanical properties
- MeSH terms
- Aged, Bone and Bones, Cadaver, Computer Simulation, Elasticity, Female, Femur, Femur Neck, Humans, Lumbar Vertebrae, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Thoracic Vertebrae, Tibia, Reproducibility of Results, Bone Density, Anisotropy, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.