Trabecular bone modulus–density relationships depend on anatomic site
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
One outstanding issue regarding the relationship between elastic modulus and density for trabecular bone is whether the relationship depends on anatomic site. To address this, on-axis elastic moduli and apparent densities were measured for 142 specimens of human trabecular bone from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27). Specimens were obtained from 61 cadavers (mean+/-SD age=67+/-15 years). Experimental protocols were used that minimized end-artifact errors and controlled for specimen orientation. Tissue moduli were computed for a subset of 18 specimens using high-resolution linear finite element analyses and also using two previously developed theoretical relationships (Bone 25 (1999) 481; J. Elasticity 53 (1999) 125). Resultant power law regressions between modulus and density did depend on anatomic site, as determined via an analysis of covariance. The inter-site differences were among the leading coefficients (p<0.02), but not the exponents (p>0.08), which ranged 1.49-2.18. At a given density, specimens from the tibia had higher moduli than those from the vertebra (p=0.01) and femoral neck (p=0.002); those from the trochanter had higher moduli than the vertebra (p=0.02). These differences could be as large as almost 50%, and errors in predicted values of modulus increased by up to 65% when site-dependence was ignored. These results indicate that there is no universal modulus-density relationship for on-axis loading. Tissue moduli computed using methods that account for inter-site architectural variations did not differ across site (p>0.15), suggesting that the site-specificity in apparent modulus-density relationships may be attributed to differences in architecture.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Nature’s hierarchical materials
Fratzl, P., & Weinkamer, R. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.06.001 · Cited by 2,800
“At a given apparent density, specimens from the proximal tibia and trochanter had higher moduli than those from the vertebral body [123].”
BackgroundBone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
Self-citationBobbert, F. S. L., Lietaert, K., Eftekhari, A. A., Pouran, B., Ahmadi, S. M., Weinans, H., & Zadpoor, A. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.024 · Cited by 873
Biological materials: Functional adaptations and bioinspired designs
Chen, P.-Y., McKittrick, J., & Meyers, M. A. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.03.001 · Cited by 766
“Gibson and Ashby [166] examined the mechanical properties of sandwich panels and give the bending compliance of a sandwich panel as:”
BackgroundMethodInfluentialMathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
“, 1997) and measurement instrumentation; – the anatomical site from which samples were retrieved (Morgan et al., 2003).”
BackgroundBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Metallic Scaffolds for Bone Regeneration
Alvarez, K., & Nakajima, H. (2009) · Materials · doi:10.3390/ma2030790 · Cited by 505
“6 g/cm [15].”
Nanoscale heterogeneity promotes energy dissipation in bone
Tai, K., Dao, M., Suresh, S., Palazoglu, A., & Ortiz, C. (2007) · Nature Materials · doi:10.1038/nmat1911 · Cited by 402
“Macroscopically, significant variations in mechanical properties have been observed for different anatomical location”
BackgroundSchileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
“The elastic modulus was obtained from a density-elasticity relationship which has been shown to produce accurate strain prediction (Schileo et al., 2007): E ¼ 6:950r1:49app ðfemoral neck specimensÞ; where elastic modulus (E) is expressed in GPa (Morgan et al., 2003), and apparent density (rapp) in g/cm 3.”
BackgroundMethodInfluentialSchileo, E., Dall’Ara, E., Taddei, F., Malandrino, A., Schotkamp, T., Baleani, M., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.017 · Cited by 372
“rapp was calculated as wet weight/bulk volume (Morgan et al., 2003).”
MethodInfluentialSubject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 330
“(3) (Morgan et al., 2003), was chosen because it was obtained with a very robust experimental protocol that minimises random errors.”
BackgroundInfluentialSynthetic bone: Design by additive manufacturing
Barba, D., Alabort, E., & Reed, R. C. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.049 · Cited by 316
The Virtual Skeleton Database: An Open Access Repository for Biomedical Research and Collaboration
Kistler, M., Bonaretti, S., Pfahrer, M., Niklaus, R., & Büchler, P. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2930 · Cited by 303
“The bone intensity values were converted into material properties [32,33] and mapped onto each node of the FE (finite element) mesh of the second order tetrahedral elements.”
MethodFabritius, H., Sachs, C., Triguero, P. R., & Raabe, D. (2009) · Advanced Materials · doi:10.1002/adma.200801219 · Cited by 302
Zhang, X.-Y., Fang, G., Leeflang, S., Zadpoor, A. A., & Zhou, J. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.12.013 · Cited by 277
Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
Orwoll, E. S., Marshall, L. M., Nielson, C. M., Cummings, S. R., Lapidus, J., Cauley, J. A., Ensrud, K., Lane, N., Hoffmann, P. R., Kopperdahl, D. L., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081201 · Cited by 265
Self-citationPeng, L., Bai, J., Zeng, X., & Zhou, Y. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.06.003 · Cited by 262
Metals for bone implants. Part 1. Powder metallurgy and implant rendering
Andani, M. T., Shayesteh Moghaddam, N., Haberland, C., Dean, D., Miller, M. J., & Elahinia, M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.025 · Cited by 258
“[18] Morgan EF, Bayraktar HH, Keaveny TM.”
BackgroundLu, T., Wen, J., Qian, S., Cao, H., Ning, C., Pan, X., Jiang, X., Liu, X., & Chu, P. K. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.018 · Cited by 253
“Despite the good biocompatibility, titanium possesses a large elastic modulus of over 100 GPa whereas PEEK has an elastic h Performance Ceramics and amics, Chinese Academy of 412409. tics, Ninth People's Hospital edicine, Shanghai 200011, PR Jiang), xyliu@mail.sic.ac.cn modulus of about 5 GPa that is closer to that of…”
BackgroundInfluentialMa, S., Tang, Q., Feng, Q., Song, J., Han, X., & Guo, F. (2019) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2019.01.023 · Cited by 239
“The elastic modulus of 316L is around 206 GPa, the yield strength is around 267.2 MPa, and the density is 7.98 g/cm3.”
BackgroundInfluentialKivell, T. L. (2016) · Journal of Anatomy · doi:10.1111/joa.12446 · Cited by 239
“…loading (Carlson & Judex, 2007), or reflect differences in bone modelling and remodelling based on anatomical location (Bass et al. 1999; Morgan & Keaveny, 2001; Morgan et al. 2003; Yeni et al. 2011; R€ath et al. 2013) or species (Chow et al. 1993; Erben, 1996; Turner, 2001; Barak et al. 2013a).”
BackgroundDragomir-Daescu, D., Op Den Buijs, J., McEligot, S., Dai, Y., Entwistle, R. C., Salas, C., Melton, L. J., Bennet, K. E., Khosla, S., & Amin, S. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0196-y · Cited by 232
Liang, H., Yang, Y., Xie, D., Li, L., Mao, N., Wang, C., Tian, Z., Jiang, Q., & Shen, L. (2019) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2019.01.012 · Cited by 229
Mechanics of intact bone marrow
Jansen, L. E., Birch, N. P., Schiffman, J. D., Crosby, A. J., & Peyton, S. R. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.06.023 · Cited by 228
“However, ultrasonic wave propagation reported that the Young’s modulus of bovine marrow is the same order of magnitude as what others have found for the surrounding spongy bone (~2GPa) (Morgan et al., 2003).”
Torres-Sanchez, C., Al Mushref, F. R. A., Norrito, M., Yendall, K., Liu, Y., & Conway, P. P. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.03.249 · Cited by 217
“2GPa, more typically 2-5GPa, and 11-24MPa, respectively [5-8].”
BackgroundKeaveny, T. M., Hoffmann, P. F., Singh, M., Palermo, L., Bilezikian, J. P., Greenspan, S. L., & Black, D. M. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080805 · Cited by 218
Self-citationEffect of porosity on the fluid flow characteristics and mechanical properties of tantalum scaffolds
Shimko, D. A., Shimko, V. F., Sander, E. A., Dickson, K. F., & Nauman, E. A. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30229 · Cited by 215
Extending DXA beyond bone mineral density: Understanding hip structure analysis
Beck, T. J. (2007) · Current Osteoporosis Reports · doi:10.1007/s11914-007-0002-4 · Cited by 215
“Though widely used in biomechanics research, there are large uncertainties in the apparent properties owing to the effects of shape and orientation (anisotropy) of the trabeculae within an element [ 9 ].”
MethodHydroxyapatite reinforced collagen scaffolds with improved architecture and mechanical properties
Kane, R. J., Weiss-Bilka, H. E., Meagher, M. J., Liu, Y., Gargac, J. A., Niebur, G. L., Wagner, D. R., & Roeder, R. K. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.01.031 · Cited by 202
Vijayavenkataraman, S., Kuan, L. Y., & Lu, W. F. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.108602 · Cited by 200
Pore functionally graded Ti6Al4V scaffolds for bone tissue engineering application
Wang, S., Liu, L., Li, K., Zhu, L., Chen, J., & Hao, Y. (2019) · Materials & Design · doi:10.1016/j.matdes.2019.107643 · Cited by 199
3D printed Ti6Al4V bone scaffolds with different pore structure effects on bone ingrowth
Deng, F., Liu, L., Li, Z., & Liu, J. (2021) · Journal of Biological Engineering · doi:10.1186/s13036-021-00255-8 · Cited by 184
Exercise Early and Often: Effects of Physical Activity and Exercise on Women’s Bone Health
Troy, K. L., Mancuso, M. E., Butler, T. A., & Johnson, J. E. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15050878 · Cited by 185
Multi-axial mechanical properties of human trabecular bone
Rincón-Kohli, L., & Zysset, P. K. (2009) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0128-z · Cited by 177
“The high significance of the fabric factor (typically p Morgan et al. 2003 ).”
BackgroundRecent origin of low trabecular bone density in modern humans
Chirchir, H., Kivell, T. L., Ruff, C. B., Hublin, J.-J., Carlson, K. J., Zipfel, B., & Richmond, B. G. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1411696112 · Cited by 177
Age-dependence of femoral strength in white women and men
Keaveny, T. M., Kopperdahl, D. L., Melton, L. J., Hoffmann, P. F., Amin, S., Riggs, B. L., & Khosla, S. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091033 · Cited by 171
Self-citationWhole Bone Mechanics and Bone Quality
Cole, J. H., & van der Meulen, M. C. H. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1784-3 · Cited by 169
“BV/TV and apparent density can explain 60% to 85% of the experimentally measured variability in compressive apparent stiffness and strength of human cancellous bone [66, 73, 79, 80, 88].”
Chevalier, Y., Pahr, D., Allmer, H., Charlebois, M., & Zysset, P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.004 · Cited by 168
Zhang, L., Song, B., Yang, L., & Shi, Y. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.05.038 · Cited by 164
Zhang, X.-Y., Fang, G., Xing, L.-L., Liu, W., & Zhou, J. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.07.064 · Cited by 162
Microcomputed tomography: approaches and applications in bioengineering
Boerckel, J. D., Mason, D. E., McDermott, A. M., & Alsberg, E. (2014) · Stem Cell Research & Therapy · doi:10.1186/scrt534 · Cited by 158
“approaches account for inhomogeneity by scaling the local Young’s modulus or ultimate stress with microCT-measured local density, either linearly or, more accurately, using a power-law relationship [18-20].”
Schileo, E., Balistreri, L., Grassi, L., Cristofolini, L., & Taddei, F. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.024 · Cited by 151
“ship adopted in our models was obtained at 5000 mε/s (reference strain rate, _ εref ) (Morgan et al., 2003).”
MethodRazfar, N., Reeves, J. M., Langohr, G. D. G., Willing, R. T., Athwal, G. S., & Johnson, J. A. (2016) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2015.11.011 · Cited by 167
Yosibash, Z., Padan, R., Joskowicz, L., & Milgrom, C. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2720906 · Cited by 144
“The literature reports expreimentally derived homogenized mechanical properties of both regions as well as isotropic Young’s modulus and other elastic constants (under the transversely isotropic/orthotropic assumption) of both regions as a function of the bone apparent density [9, 11–16].”
BackgroundAbdelwahab, A. A., Maligno, A. R., & Silberschmidt, V. V. (2011) · Computational Materials Science · doi:10.1016/j.commatsci.2011.01.021 · Cited by 159
“The effect of bone quantity on the mechanical behaviour and structural integrity of bone was established previously [5, 6], however, more in-depth investigations are still required of the contributory effects of microstructure, material properties, and microcrack propagation [3, 7].”
BackgroundBess, S. R., Harris, J. E., Turner, A. W. L., Lafage, V., Smith, J. S., Shaffrey, C. I., Schwab, F. J., & Haid, R. W. (2016) · Journal of Neurosurgery Spine · doi:10.3171/2016.6.spine151477 · Cited by 143
“…anatomical structures in finite element model Property Modulus (MPa) ν References Cortical bone 12,000 0.2 Goel et al., 1995 Cancellous bone 300 0.2 Morgan et al., 2003; Bowden et al., 2008 Annulus fibrosus Mooney-Rivlin c1 = 0.18, c2 = 0.045 NA Schmidt et al., 2007 Nucleus…”
InfluentialBiomechanical Computed Tomography analysis (BCT) for clinical assessment of osteoporosis
Keaveny, T., Clarke, B., Cosman, F., Orwoll, E., Siris, E., Khosla, S., & Bouxsein, M. (2020) · Osteoporosis International · doi:10.1007/s00198-020-05384-2 · Cited by 117
Self-citationSelective laser melted Ti6Al4V split-P TPMS lattices for bone tissue engineering
Rezapourian, M., Jasiuk, I., Saarna, M., & Hussainova, I. (2023) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2023.108353 · Cited by 144
Perilli, E., Baleani, M., Öhman‐Mägi, C., Fognani, R., Baruffaldi, F., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.08.003 · Cited by 158
“(2006), to properly investigate the mechanical properties of human cancellous bone under compression, it might be important to perform this type of experiments on cancellous bone taken from numerous subjects and at different sites, as it has been shown that the mechanical properties may change also with anatomical sit…”
BackgroundVertebral Osteoporosis and Trabecular Bone Quality
Donnell, P. M., McHugh, P. E., & Mahoney, D. O. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9239-9 · Cited by 165
Scanning electron microscopic studies of the zonular apparatus in human and monkey eyes.
Rohen, J. W. (1979) · PubMed · Cited by 135
Statistical modelling of the whole human femur incorporating geometric and material properties
Bryan, R., Mohan, P. S., Hopkins, A. R., Galloway, F., Taylor, M., & Nair, P. B. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.10.008 · Cited by 145
Trabelsi, N., Zohar Yosibash, A., Wutte, C., Augat, P., & Eberle, S. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.03.024 · Cited by 127
“…between Young's modulus and bone density, with a constant Poisson's ratio, see e.g. (Cody et al., 2000; Keller, 1994; Keyak and Falkinstein, 2003; Morgan et al., 2003) and the review (Helgason et al., 2008a), we use in our simulations the Keyak & Falkinstein relationship (Keyak and Falkinstein,…”
Knowles, N. K., Reeves, J. M., & Ferreira, L. M. (2016) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-016-0072-2 · Cited by 134
“…Unknown – used in (Eberle et al. 2013a, b); d (Keyak et al. 2005) – 80 kVp, 280 mAs Experimentally derived density-modulus relationships are site-specific (Morgan et al. 2003; Schileo et al. 2008), and are also affected by the quality and pathology of the bone, with density being a function of…”
BackgroundThe design and in vivo testing of a locally stiffness-matched porous scaffold
Ghouse, S., Reznikov, N., Boughton, O. R., Babu, S., Ng, K. C. G., Blunn, G. W., Cobb, J. P., Stevens, M. M., & Jeffers, J. R. T. (2019) · Applied Materials Today · doi:10.1016/j.apmt.2019.02.017 · Cited by 125
Accuracy of finite element predictions in sideways load configurations for the proximal human femur
Grassi, L., Schileo, E., Taddei, F., Zani, L., Juszczyk, M., Cristofolini, L., & Viceconti, M. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.10.019 · Cited by 127
Lee, D. C., Hoffmann, P. F., Kopperdahl, D. L., & Keaveny, T. M. (2017) · Bone · doi:10.1016/j.bone.2017.07.029 · Cited by 133
Self-citationHaïat, G., Padilla, F. R., Peyrin, F., & Laugier, P. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070209 · Cited by 122
Role of Trabecular Microarchitecture in Whole-Vertebral Body Biomechanical Behavior
Fields, A. J., Eswaran, S. K., Jekir, M. G., & Keaveny, T. M. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090317 · Cited by 145
Self-citationMärdian, S., Schaser, K., Duda, G. N., & Heyland, M. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.02.006 · Cited by 120
Matsuura, M., Eckstein, F., Lochmüller, E.-M., & Zysset, P. K. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0073-7 · Cited by 117
“A more recent study reported that there is no single, universal relationship between elastic properties and density across anatomic site for on-axis loading ( Morgan et al. 2003 ).”
BackgroundKeaveny, T. M., McClung, M. R., Genant, H. K., Zanchetta, J. R., Kendler, D., Brown, J. P., Goemaere, S., Recknor, C., Brandi, M. L., Eastell, R., et al. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2024 · Cited by 117
Self-citationComparison of micro-level and continuum-level voxel models of the proximal femur
Verhulp, E. E., van Rietbergen, B., & Huiskes, R. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.10.027 · Cited by 138
Wang, S., Shi, Z., Liu, L., Zhou, X., Zhu, L., & Hao, Y. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.108830 · Cited by 115
Density and mechanical properties of vertebral trabecular bone—A review
Öhman‐Mägi, C., Holub, O., Wu, D., Hall, R. M., & Persson, C. (2021) · JOR Spine · doi:10.1002/jsp2.1176 · Cited by 135
“34,35 In addition, the large variation in density-mechanical property relationships is problematic for the development of biomaterials: in vertebroplasty, for example, the development of a bone cement that matches the modulus of non-pathological trabecular bone could be of interest, 36 as the large…”
BackgroundMethodResultInfluentialPermeability studies of artificial and natural cancellous bone structures
Syahrom, A., Kadir, M. R. A., Abdullah, J., & Öchsner, A. Ö. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.08.011 · Cited by 115
Mechanisms of uniformity of yield strains for trabecular bone
Bayraktar, H. H., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.045 · Cited by 127
“Because of this alignment and the experimentally observed almost linear modulus-density relation (Morgan et al., 2003; Williams and Lewis, 1982), it has been proposed that trabecular bone can be modeled as an aligned parallel rod/plate-type cellular solid structure for axial loading (Keaveny, 1997, 2001).”
BackgroundSelf-citationSimilarity in the fatigue behavior of trabecular bone across site and species
Haddock, S. M., Yeh, O. C., Mummaneni, P. V., Rosenberg, W. S., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00245-8 · Cited by 128
Self-citationGoda, I., Assidi, M., & Ganghoffer, J. (2013) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0486-z · Cited by 114
Qasim, M., Farinella, G., Ju, Z., Li, X., Yang, L., Eastell, R., & Viceconti, M. (2016) · Osteoporosis International · doi:10.1007/s00198-016-3597-4 · Cited by 122
Nishiyama, K. K., Gilchrist, S., Guy, P., Cripton, P. A., & Boyd, S. K. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.02.025 · Cited by 114
Association of hip strength estimates by finite-element analysis with fractures in women and men
Amin, S., Kopperdhal, D. L., Melton, L. J., Achenbach, S. J., Therneau, T. M., Riggs, B. L., Keaveny, T. M., & Khosla, S. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.347 · Cited by 118
Self-citationComparison of non-invasive assessments of strength of the proximal femur
Jóhannesdóttir, F., Thrall, E., Muller, J. A., Keaveny, T. M., Kopperdahl, D. L., & Bouxsein, M. (2017) · Bone · doi:10.1016/j.bone.2017.07.023 · Cited by 113
Self-citationFalcinelli, C., Schileo, E., Balistreri, L., Baruffaldi, F., Bordini, B., Viceconti, M., Albisinni, U., Ceccarelli, F., Milandri, L., Toni, A., et al. (2014) · Bone · doi:10.1016/j.bone.2014.06.038 · Cited by 108
“49 (where elastic modulus (E) is expressed in GPa and apparent density in g/cm) [26]; the elasticmodulus Ewas element-wise”
BackgroundFracture risk assessment and clinical decision making for patients with metastatic bone disease
Damron, T. A., & Mann, K. A. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24660 · Cited by 108
Majumder, S., Roychowdhury, A., & Pal, S. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.001 · Cited by 104
Chong, D. Y. R., Hansen, U. N., & Amis, A. A. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.12.006 · Cited by 104
Bryan, R., Nair, P. B., & Taylor, M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.038 · Cited by 117
“…the proportional relationship between grey level and apparent density it was possible to use the equation defined for density–elasticity relation in the femoral neck by Morgan et al. (2003) to give each node, and hence element by averaging the values at its constituent nodes, a Young’s modulus.”
MethodChen, Y., Dall’Ara, E., Sales, E., Manda, K., Wallace, R. J., Pankaj, P., & Viceconti, M. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.09.014 · Cited by 112
“The material properties for all microFE models were assumed to be linear and isotropic, with a uniform Young׳s modulus of 17 GPa (Bayraktar et al., 2004; Morgan et al., 2003) and a Poisson׳s ratio of 0.”
MethodInfluentialVäänänen, S. P., Grassi, L., Flivik, G., Jurvelin, J. S., & Isaksson, H. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.06.001 · Cited by 120
Additively Manufactured and Surface Biofunctionalized Porous Nitinol
Karaji, Z. G., Speirs, M., Dadbakhsh, S., Kruth, J., Weinans, H., ZADPOOR, A. A., & Yavari, S. A. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b14026 · Cited by 100
Total ankle replacement design and positioning affect implant-bone micromotion and bone strains
Sopher, R., Amis, A. A., Calder, J. D., & Jeffers, J. R. T. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.01.022 · Cited by 100
Wolfram, U., Wilke, H., & Zysset, P. K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.02.026 · Cited by 121
Material Properties of the Mandibular Trabecular Bone
Lakatos, É. I., Magyar, L., & Bojtár, I. (2014) · Journal of Medical Engineering · doi:10.1155/2014/470539 · Cited by 101
“Despite the destructive effect of the ice crystals, the most spread preservation technique is freezing [2, 6, 9, 11, 14].”
BackgroundPrediction of incident vertebral fracture using CT-based finite element analysis
Allaire, B. T., Lu, D., Johannesdottir, F., Kopperdahl, D., Keaveny, T. M., Jarraya, M., Guermazi, A., Bredella, M. A., Samelson, E. J., Kiel, D. P., et al. (2019) · Osteoporosis International · doi:10.1007/s00198-018-4716-1 · Cited by 95
Self-citationGraphene oxide as a scaffold for bone regeneration
Holt, B. D., Wright, Z. M., Arnold, A. M., & Sydlik, S. A. (2016) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1437 · Cited by 101
“The modulus of trabecular bone has likewise been found to be anisotropic and varies with location in the body.(21) It is estimated that cortical bone is up to 25% stronger than less dense, more porous cancellous bone.”
BackgroundAustman, R. L., Milner, J. S., Holdsworth, D. W., & Dunning, C. E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.017 · Cited by 101
“Of the eight specimens, three were matched most closely to the experimental values by using the Carter and Hayes (1977) equation (which tended to overestimate) and five were matched most closely using the Morgan et al. (2003) equation (which tended to under-estimate).”
BackgroundMethodResultInfluentialNaylor, K. E., McCloskey, E. V., Eastell, R., & Yang, L. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1856 · Cited by 104
“Material properties were then derived from vBMD by using the empirical equations of Morgan and colleagues.((21,22)) The FE boundary conditions simulated a fall on the greater trochanter: peak impact force (Fpeak) was applied to the greater trochanter, with prevention of medial displacement of the femoral head and prev…”
MethodTotal Disc Replacement Positioning Affects Facet Contact Forces and Vertebral Body Strains
Rundell, S. A., Auerbach, J. D., Balderston, R. A., & Kurtz, S. M. (2008) · Spine · doi:10.1097/brs.0b013e318186b258 · Cited by 98
“The quantitative relationship between BMD and elastic modulus in cancellous vertebral bone, as reported by Morgan et al and Ulrich et al, was used to define a nonlinear relationship between BMD and orthotropic elastic modulus.(28,29) Elastic moduli within the vertebral body fell within what has been previously reporte…”
MethodHaïat, G., Padilla, F. R., Peyrin, F., & Laugier, P. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2832611 · Cited by 93
van Lenthe, H., Stauber, M., & Müller, R. (2006) · Bone · doi:10.1016/j.bone.2006.06.033 · Cited by 91
A new approach for assigning bone material properties from CT images into finite element models
Chen, G., Schmutz, B., Epari, D. R., Rathnayaka, K., Ibrahim, S. K., Schuetz, M., & Pearcy, M. J. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.10.040 · Cited by 92
“Step 2: the Young’s modulus (E) is related to the bone density (r) by E=Cr, where C and r are constants and r is either the ash density or apparent density (Carter and Hayes, 1977; Kopperdahl et al., 2002; Morgan et al., 2003; Wirtz et al., 2000).”
BackgroundBiomechanical Assessment of a PEEK Rod System for Semi-Rigid Fixation of Lumbar Fusion Constructs
Gornet, M. F., Chan, F. W., Coleman, J. C., Murrell, B., Nockels, R. P., Taylor, B. A., Lanman, T. H., & Ochoa, J. A. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004862 · Cited by 103
“Material properties were assigned based on current literature [50–55].”
MethodFemoral shaft strains during daily activities: Implications for atypical femoral fractures
Martelli, S., Pivonka, P., & Ebeling, P. R. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.08.001 · Cited by 89
“The Young’s modulus distribution was calculated from the bone apparent density distribution using the relationship found by Morgan et al. (2003).”
MethodMechanisms of Interaction of Ultrasound With Cancellous Bone: A Review
Wear, K. A. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2947755 · Cited by 95
Risedronate and alendronate suppress osteocyte apoptosis following cyclic fatigue loading
Follet, H., Li, J., Phipps, R. J., Hui, S. L., Condon, K. W., & Burr, D. B. (2006) · Bone · doi:10.1016/j.bone.2006.12.052 · Cited by 96
Sensini, A., Massafra, G., Gotti, C., Zucchelli, A., & Cristofolini, L. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.645544 · Cited by 95
“(C) View of the tendon fibers observed with SEM (scale bar = 1.8 µm) adapted from Moshiri and Oryan (2013) (reproduced with permission under the terms of the CC BY 4.0 license.”
MethodInfluentialVelioglu, Z. B., Pulat, D., Demirbakan, B., Özcan, B., Bayrak, E., & Erişken, C. (2018) · Connective Tissue Research · doi:10.1080/03008207.2018.1499732 · Cited by 83
“34 GPa, respectively (38,39) while modulus values of scaffolds in this study were between 324.”
BackgroundZhou, B., Liu, X. S., Wang, J., Lu, X. L., Fields, A. J., & Guo, X. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.11.039 · Cited by 85
Vaughan, T. J., McCarthy, C. T., & McNamara, L. M. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.03.003 · Cited by 92
Metadata
- Authors
- Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 36
- Issue
- 7
- Pages
- 897-904
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2088873760
- Cited by
- 1,209
- References
- 49
- Citations by year
- 2026: 73 · 2025: 72 · 2024: 79 · 2023: 71 · 2022: 78 · 2021: 99 · 2020: 85 · 2019: 59 · 2018: 56 · 2017: 55 · 2016: 61 · 2015: 55 · 2014: 62 · 2013: 43 · 2012: 37
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, elastic modulus, bone mineral density, bone structure, finite element analysis, vertebrae, proximal tibia, femoral neck, power-law regression, bone mechanical properties
- MeSH terms
- Aged, Bone and Bones, Cadaver, Computer Simulation, Elasticity, Female, Femur, Femur Neck, Humans, Lumbar Vertebrae, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Thoracic Vertebrae, Tibia, Reproducibility of Results, Bone Density, Anisotropy, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.