Trabecular bone modulus–density relationships depend on anatomic site
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
One outstanding issue regarding the relationship between elastic modulus and density for trabecular bone is whether the relationship depends on anatomic site. To address this, on-axis elastic moduli and apparent densities were measured for 142 specimens of human trabecular bone from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27). Specimens were obtained from 61 cadavers (mean+/-SD age=67+/-15 years). Experimental protocols were used that minimized end-artifact errors and controlled for specimen orientation. Tissue moduli were computed for a subset of 18 specimens using high-resolution linear finite element analyses and also using two previously developed theoretical relationships (Bone 25 (1999) 481; J. Elasticity 53 (1999) 125). Resultant power law regressions between modulus and density did depend on anatomic site, as determined via an analysis of covariance. The inter-site differences were among the leading coefficients (p<0.02), but not the exponents (p>0.08), which ranged 1.49-2.18. At a given density, specimens from the tibia had higher moduli than those from the vertebra (p=0.01) and femoral neck (p=0.002); those from the trochanter had higher moduli than the vertebra (p=0.02). These differences could be as large as almost 50%, and errors in predicted values of modulus increased by up to 65% when site-dependence was ignored. These results indicate that there is no universal modulus-density relationship for on-axis loading. Tissue moduli computed using methods that account for inter-site architectural variations did not differ across site (p>0.15), suggesting that the site-specificity in apparent modulus-density relationships may be attributed to differences in architecture.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
In the citing paper
“Within a single anatomic site, the modulus and strength relations appear to be linear because the range of apparent density is less than an order of magnitude (82, 91).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [91]
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Items 701–800 of 1,000
Ashjaee, N., Kalajahi, S. M. H., & Johnston, J. D. (2020) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.12.006 · Cited by 8
Luo, Y. (2021) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-020-01198-8 · Cited by 8
Bone Organic-Inorganic Phase Ratio Is a Fundamental Determinant of Bone Material Quality
Luo, Y., & Amromanoh, O. A. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/4928396 · Cited by 13
“For example, the relations are found anatomic site-dependent [27]; they can not explain why old bones are more brittle than young bones even they have similar density [28], and why bones have different compressive and tensile strength [29, 30].”
BackgroundTrần, T. N., Wolf, M. A., Winter, P., & Landgraeber, S. (2022) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2022.105635 · Cited by 9
Zheng, L., Huang, X., Li, C., Li, P., Lin, Z., & Huang, S. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e12101 · Cited by 9
“In fact, this anatomical variation has been found in most previous studies (Li and Aspden, 1997; Morgan et al., 2003; Tassani et al., 2011; Zhang et al., 2010).”
ResultYang, A., Mao, W., Chang, S., & Dong, Y. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1082613 · Cited by 8
Stemless reverse humeral component neck-shaft angle has an influence on initial fixation
Cunningham, D. E., Spangenberg, G. W., Langohr, G. D. G., Athwal, G. S., & Johnson, J. A. (2023) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2023.06.035 · Cited by 8
Ruffoni, D., & van Lenthe, H. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00093-3 · Cited by 11
Eswaran, S. K., Bevill, G. R., Nagarathnam, P., Allen, M. R., Burr, D. B., & Keaveny, T. M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.11.023 · Cited by 8
“The total bone mass was calculated as the total volume of bone elements multiplied by an assumed uniform tissue density of 2.05 g/cm3 (Morgan et al., 2003) for all bone elements.”
InfluentialSelf-citationGíslason, M. K., Ingvarsson, P. E., Gargiulo, P., Yngvason, S., Gudmundsdóttir, V., Knútsdóttir, S., & Helgason, Þ. (2014) · European Journal of Translational Myology · doi:10.4081/ejtm.2014.2187 · Cited by 8
Johnson, J. E., Brouillette, M. J., Permeswaran, P., Miller, B. J., & Goetz, J. E. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109825 · Cited by 8
The relationship between orthopedic clinical imaging and bone strength prediction
Gong, H., Zhang, M., Jia, S., & Lv, L. (2021) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2021.100060 · Cited by 10
Youssefian, S., Bressner, J. A., Osanov, M., Guest, J. K., Zbijewski, W. B., & Levin, A. S. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25138 · Cited by 8
Correlation of mineral density and elastic modulus of dog dentin using μ-CT and nanoindentation
Soukup, J. W., Jeffery, J. J., Drizin, S. R., Hetzel, S., Stone, D. S., Eriten, M., Ploeg, H., & Henak, C. R. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111434 · Cited by 7
Martin, J., Johnson, N. A., Shepherd, J. H., & Dias, J. J. (2023) · Bone & Joint Open · doi:10.1302/2633-1462.48.bjo-2023-0058.r1 · Cited by 7
Szyszko, J. A., Aldieri, A., Mattina, A. A. L., & Viceconti, M. (2024) · PLoS ONE · doi:10.1371/journal.pone.0305474 · Cited by 9
“2, Istituto Ortopedico Rizzoli, Bologna, Italy) was used to assign heterogeneous linear elastic material properties to the models, and specifically to map the HU-based Young’s modulus values to the mesh elements [28, 29].”
Vitamin D and hip protectors in osteosarcopenia: a combined hip fracture preventing approach
Giustina, A., & Giustina, A. (2024) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-024-09907-8 · Cited by 11
Luan, S., & Morgan, E. F. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.106888 · Cited by 7
Self-citationBone mineral density surrounding the screw thread predicts the risk of pedicle screw loosening
Jiang, Y., Yi, W., Liu, Y., Yang, J., Zhou, K., & Yang, H. (2025) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2025.112542 · Cited by 7
Liao, R., Pan, R., Zuo, C., Liang, H., Mai, Z., Yin, J., Guo, S., Wang, H., Murr, L. E., & Li, K. (2025) · Thin-Walled Structures · doi:10.1016/j.tws.2025.114441 · Cited by 12
Tensile modulus of human orbital wall bones cut in sagittal and coronal planes
Żerdzicki, K., Lemski, P., Kłosowski, P., Skorek, A., Trzebiatowski, M. Z., & Koberda, M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0259363 · Cited by 7
“for experiments on human vertebra, tibia and femur [11].”
BackgroundMimata, H., Matsuura, Y., Yano, S., Ohtori, S., & Todo, M. (2023) · Injury · doi:10.1016/j.injury.2023.111163 · Cited by 7
Pradeep, K., & Pal, B. (2023) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2023.104084 · Cited by 7
Pradeep, K., Pal, B., Mukherjee, K., & Shetty, G. M. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104178 · Cited by 7
Saß, J., Saemann, M., Kebbach, M., Soodmand, E., Wree, A., Bader, R., & Kluess, D. (2024) · Life · doi:10.3390/life14070841 · Cited by 10
“The applied properties are in the range of previous studies [52–54] and have shown good agreement with experimental tests [41].”
ResultRana, M., Karmakar, S. K., Verdonschot, N. J. J., & Chowdhury, A. R. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106747 · Cited by 7
Bahrami, M., Khonakdar, H., Moghaddam, A., Mahand, S. N., Bambizi, P. E., Kruppke, B., & Khonakdar, H. A. (2024) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2024.10.001 · Cited by 7
Ojanen, X., Töyräs, J., Inkinen, S. I., Malo, M. K. H., Isaksson, H., & Jurvelin, J. S. (2016) · The Journal of the Acoustical Society of America · doi:10.1121/1.4962347 · Cited by 7
Farvardin, A., Basafa, E., Bakhtiarinejad, M., & Armand, M. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.07.012 · Cited by 7
Saldarriaga, S., Jiménez, S. C., Rezaei, A., & Giambini, H. (2020) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2020.1754808 · Cited by 8
“These literature equations were obtained by performing vertebral coupon experimental testing and linear regression analysis relating compressive elastic modulus and density measured using CT (Morgan et al. 2003).”
MethodRegional apparent density correlations within the proximal humerus
Reeves, J. M., Vanasse, T., Roche, C. P., Athwal, G. S., Johnson, J. A., Faber, K. J., & Langohr, G. D. G. (2021) · JSES International · doi:10.1016/j.jseint.2020.12.001 · Cited by 9
Chen, X., Myers, C. A., Clary, C. W., DeWall, R. J., Fritz, B., Blauth, M., & Rullkoetter, P. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110363 · Cited by 7
Specimen-specific fracture risk curves of lumbar vertebrae under dynamic axial compression
Robinson, D. L., Tse, K. M., Franklyn, M., Zhang, J., Fernandez, J., Ackland, D. C., & Lee, P. V. S. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104457 · Cited by 7
Rungruangbaiyok, C., Azari, F., van Lenthe, H., Sloten, J. V., Tangtrakulwanich, B., & Chatpun, S. (2021) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-021-00607-1 · Cited by 7
Properties of electrophoretically deposited single wall carbon nanotube films
Lim, J., Jalali, M., & Campbell, S. A. (2015) · Thin Solid Films · doi:10.1016/j.tsf.2015.05.042 · Cited by 7
Feng, W., Yi, W., Song, F., Li, Z., Fu, R., Din, R. U., Li, J., Liu, W., Liu, Y., & Yang, H. (2022) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2022.103882 · Cited by 8
Zheng, L., Dai, Y.-X., Zheng, Y., He, X., Wu, M., Zheng, D., Li, C., Fan, Y., & Lin, Z. (2022) · BioMedical Engineering OnLine · doi:10.1186/s12938-022-01039-x · Cited by 8
“More than 70% of the variance in the Young’s modulus of trabeculae can be explained by BV/TV [11, 32, 33], therefore, we must determine how far these tiny variances between the medial and”
BackgroundHambli, R., Leacy, R. A. D., & Vienney, C. (2023) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2023.105893 · Cited by 7
Sreenivasan, D., Watson, M., Callon, K. E., Dray, M. S., Das, R. K., Grey, A. B., Cornish, J., & Fernandez, J. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.07.013 · Cited by 7
Reliable Patient-Specific Simulations of the Femur
Yosibash, Z., & Trabelsi, N. (2011) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/8415_2011_89 · Cited by 8
“[7, 8, 24, 22, 25].”
Computational modeling of long-term effects of prophylactic vertebroplasty on bone adaptation
Badilatti, S. D., Christen, P., Ferguson, S. J., & Müller, R. (2017) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411916683222 · Cited by 8
Design Study on Customised Piezoelectric Elements for Energy Harvesting in Total Hip Replacements
Lange, H.-E., Bader, R., & Kluess, D. (2021) · Energies · doi:10.3390/en14123480 · Cited by 7
“on basis of the apparent density ρapp [25] was assumed with a maximum Young’s modulus of 20 GPa, please see [15] for more detail.”
MethodVale, A. C., Aleixo, I. P., Lúcio, M., Saraiva, A. P., Caetano‐Lopes, J., Rodrigues, A. M., Amaral, P. M., Rosa, L. G., Monteiro, J., Fonseca, J. E., et al. (2013) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-14-295 · Cited by 7
Effect of Model Parameters on the Biomechanical Behavior of the Finite Element Cervical Spine Model
Doğru, S. C., & Arslan, Y. Z. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/5593037 · Cited by 7
“Equation (1) was used for the relationships between HU and density (ρ) expressed in kg/m(3) [25, 26]:”
BackgroundMethodInfluentialRetractedGong, H., Zhang, M., Zhang, H., Zhu, D., & Yang, L. (2006) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-006-0698-8 · Cited by 7
“3 [ 18 ], representing cortical bone; for P = 1, ρ = 0 g/cm 3 , representing no bone), the”
MethodInfluentialEvaluation of mesh morphing and mapping techniques in patient specific modeling of the human pelvis
Salo, Z., Beek, M., & Whyne, C. M. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2500 · Cited by 18
“It has been established that the correlation between Young’s modulus (MPa) and bone density is dependent on anatomic location, which can be credited to variations in structure [33].”
BackgroundJohnson, J. E., Brouillette, M. J., Miller, B. J., & Goetz, J. E. (2023) · Biomedical Engineering and Computational Biology · doi:10.1177/11795972231166240 · Cited by 6
Martínez‐Reina, J., Ojeda, J., Calvo‐Gallego, J. L., Pivonka, P., & Martelli, S. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106773 · Cited by 6
Strack, D., Rayudu, N. M., Kirschke, J. S., Baum, T. H., & Subburaj, K. (2024) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2024.2422901 · Cited by 6
Kwak, D.-K., Lee, Y., Lee, S. J., Lee, S., & Yoo, J. (2025) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-025-08681-1 · Cited by 9
“The relationship between Hounsfield unit and elastic modulus was analyzed [28, 29]: where ρ is the apparent density (g/cm 3 ) and the unit of E is MPa.”
Weaver, A. A., Greene, K. A., Leng, X., Lenchik, L., Lyles, M. F., Nicklas, B. J., Baker, A. M., Helgason, B., Stapleton, J. R., Devane, K. S., et al. (2026) · Osteoporosis International · doi:10.1007/s00198-026-07845-6 · Cited by 9
“4 [33].”
Ceddia, M., Romasco, T., Pietro, N. D., Cipollina, A., Piattelli, A., Lamberti, L., & Trentadue, B. (2026) · Materials · doi:10.3390/ma19050869 · Cited by 9
“Rho et al. [19] and Morgan et al. [20] established key density-elasticity relationships showing that small reductions in bone density markedly decrease stiffness and enlarge the implant-bone modulus gap when rigid materials are used.”
The effect of bone marrow on the mechanical behavior of porcine trabecular bone
Bravo, A. E., Osnaya, L. C., Ramírez, E. I., Jacobo, V. H., & Ortiz, A. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab4dc0 · Cited by 6
“All specimens were cut from roughly the same anatomical site, as it has been shown that it is also important when measuring mechanical properties (Morgan et al 2003) The applied load during cutting was regulated so that the premature damage of the trabeculae wasminimized.”
BackgroundHernandez, B. A., Gill, H. S., & Gheduzzi, S. (2020) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.07.009 · Cited by 6
Huo, S., Sun, C., Liu, G., & Ao, R. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104444 · Cited by 6
Finite element analysis of femoral neck strains during stair ascent and descent
Deng, C., Gillette, J. C., & Derrick, T. R. (2021) · Scientific Reports · doi:10.1038/s41598-021-87936-y · Cited by 7
Prediction of proximal femur fracture risk from DXA images based on novel fracture indexes
Zellagui, S., Hivet, A., Mouss, M. E., & Hambli, R. (2021) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2020.1833367 · Cited by 8
“Then, mechanical properties are assigned to each pixel according to its BMD using the relationship provided by Morgan and Keaveny (2001), Morgan et al. (2003) in the case of tensile stress (the dominant stress state in bending), σy MPað Þ ¼ 50:1ρ2:04app if ρapp � 0:355 g=cm 3ð Þ 22:6ρ1:26app if…”
MethodInfluentialKwak, D.-K., Oh, S.-H., Lee, S., Lee, S., Lee, Y.-M., & Yoo, J. (2022) · Bone and Joint Research · doi:10.1302/2046-3758.113.bjr-2021-0363.r1 · Cited by 6
The Hydration State of Bone Tissue Affects Contrast in Neutron Tomographic Images
Törnquist, E., Cann, S. L., Tengattini, A., Helfen, L., Kok, J., Hall, S. A., & Isaksson, H. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.911866 · Cited by 6
“As trabecular ultrastructure is optimized for the loading conditions occurring in the specific anatomical site, the mechanical properties vary depending on anatomical origin (Morgan et al., 2003; Endo et al., 2016).”
BackgroundA Novel Screw Modeling Approach to Study the Effects of Screw Parameters on Pullout Strength
Song, F., Feng, W., Yang, D., Li, G., Iqbal, K., Liu, Y., & Yang, H. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4055035 · Cited by 6
Comparison of morphing techniques to develop subject-specific finite element models of vertebrae
Rubenstein, R. I., Lalwala, M., Devane, K. S., Koya, B., Kiani, B., & Weaver, A. A. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2022.2113994 · Cited by 6
Cooperman, C., Wiznia, D. H., Kunsel, K., Roytman, G. R., Ani, L., Pratola, D., Lee, G., Tommasini, S. M., & Bernstein, J. A. (2022) · Arthroplasty Today · doi:10.1016/j.artd.2022.08.011 · Cited by 7
Kansal, A., Dvivedi, A., & Kumar, P. (2023) · Rapid Prototyping Journal · doi:10.1108/rpj-03-2023-0077 · Cited by 6
van den Munckhof, S., Nikooyan, A. A., & ZADPOOR, A. A. (2014) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519415300033 · Cited by 6
Gong, H., Fan, Y., Zhang, M., & Qin, L. (2008) · Acta Mechanica Sinica · doi:10.1007/s10409-008-0198-2 · Cited by 6
“other surfaces unconstrained to simulate the boundary conditions that have been used in other mechanical testing procedures [15,16].”
MethodLian, Z., Guan, H., Loo, Y., Ivanovski, S., & Johnson, N. W. (2010) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/10/1/012125 · Cited by 6
Deformation behaviour of a natural-shaped bone scaffold
Kytýř, D., Doktor, T., Jiroušek, O., Fíla, T., Koudelka, P., & Zlámal, P. (2016) · Materiali in tehnologije · doi:10.17222/mit.2014.190 · Cited by 6
Subchondral Bone Features and Mechanical Properties as Biomarkers of Osteoarthritis
Johnston, J. D., Burnett, W. D., & Kontulainen, S. A. (2016) · Exposure and Health · doi:10.1007/978-94-007-7745-3_46-1 · Cited by 6
Statistical Shape and Appearance Models for Bone Quality Assessment
Raudaschl, P., & Fritscher, K. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-810493-4.00018-3 · Cited by 6
Alexander, S. L., & Weerasooriya, T. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104302 · Cited by 6
Finite Element Analysis of Cannulated Screws as Prophylactic Intervention of Hip Fractures
Rhee, B., Tommasini, S. M., Milligan, K., Moulton, J., Leslie, M. P., & Wiznia, D. H. (2021) · Geriatric Orthopaedic Surgery & Rehabilitation · doi:10.1177/21514593211055890 · Cited by 6
“63 g/cc average densities for healthy, osteopenic, and osteoporotic bone, respectively).(21,22) ScanIP defined the femur as 7 discrete materials with ranging Young’s moduli and defined cortical bone as any material with a wet apparent density greater than 1 g/cc.”
BackgroundProvatidis, C. G., Vossou, C., Πετροπούλου, Ε., Balanika, A. P., & Lyritis, G. P. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.12.003 · Cited by 6
Greybe, D. G., Boland, M. R., Wu, T., & Mithraratne, K. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2766 · Cited by 6
Milan, J., Yone, C. C., Rossi, J.-M., & Chabrand, P. R. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.10.011 · Cited by 7
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Self-citationA pilot finite element study of an osteoporotic L1-vertebra compared to one with normal T-score
Provatidis, C. G., Vossou, C., Koukoulis, I. N., Balanika, A. P., Baltas, C. S., & Lyritis, G. P. (2009) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840903099703 · Cited by 9
“The correlation of BMD with the elastic modulus was performed with empirical relationships retrieved from experimental results (Zannoni et al. 1998; Morgan et al. 2003).”
MethodNanomaterials for cartilage tissue engineering
Chung, E. J., Shah, N., & Shah, R. N. (2013) · Elsevier eBooks · doi:10.1533/9780857097231.2.301 · Cited by 8
Cha, Y., Park, S., Jung, C.-H., Kim, J.-W., Yoo, J., Kim, J.-T., Jeon, Y., & Han, K. J. (2024) · Clinics in Orthopedic Surgery · doi:10.4055/cios24194 · Cited by 5
“In accordance with Bergmann et al.’s approach, all the models were subjected to loads corresponding to normal walking and stair-climbing conditions.”
Gasparro, R., Renno, F., Vita, S. D., Lanzotti, A., Martorelli, M., Penta, F., Sammartino, G., & Ausiello, P. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14072535 · Cited by 5
“The elastic modulus E is influenced by density at specific anatomical sites, and may be expressed according to [34] as follows: So, the relationship between ash density ( ρ ASH) and apparent density ( ρ APP) was determined as follows: E = 10,494 ρ _ASHˆ1.”
Effect of Humeral Stem Sizing and Alignment on Stress Shielding: A Virtual Cohort Study
Mueri, C., Maquer, G., Henderson, A., Bischoff, J. E., & Favre, P. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3568877 · Cited by 5
“A phantomless calibration was used to derive the apparent density from the HU [26], [27] and the density-elasticity relationship by Morgan et al. [28] was used to compute the elastic modulus of cancellous bone within the metaphysis.”
Xu, C., Zhang, Y., Zhang, L., Liu, Q., & Ren, L. (2025) · Advanced Engineering Materials · doi:10.1002/adem.202500070 · Cited by 5
Huang, C., Zhang, Z.-F., Zhang, X., Liu, F., Fang, Z., Xi, Z., & Li, J.-C. (2022) · Frontiers in Surgery · doi:10.3389/fsurg.2022.967399 · Cited by 5
“The material properties of cortical and cancellous bones were defined according to anisotropic laws, and BEP was set as an isotropic material (36, 37).”
MethodSunavala‐Dossabhoy, G., Saba, B. M., & McCarthy, K. J. (2024) · Bioengineering · doi:10.3390/bioengineering11040393 · Cited by 5
“Three E-ρ relationships (MPa) were evaluated and Equations (2) and (3) produced similar results [29,30].”
ResultPark, H. J., Suh, D. H., Hong, H., Nha, K. W., Kim, H., Kang, K., & Kim, J. G. (2024) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-024-05283-w · Cited by 5
Design of an Ultra-Low Modulus 3D Printed Titanium Bio-Metamaterials for Bone Replacement
Song, F., Wang, L., Zhang, Y., Qiu, J., Luo, J. T., Wang, L., & Li, D. (2025) · Additive Manufacturing Frontiers · doi:10.1016/j.amf.2025.200197 · Cited by 4
Yassine, R. A., & Hamade, R. F. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02019-5 · Cited by 5
Inacio, J. V., Cristino, D. M., Hast, M. W., & Dailey, H. L. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4051433 · Cited by 6
Chen, X., Andreassen, T. E., Myers, C. A., Clary, C. W., Coombs, D. J., DeWall, R. J., Fritz, B., Bracey, D. N., Hedge, V., & Rullkoetter, P. J. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104960 · Cited by 5
O’Rourke, D., Johnson, L. J., Jagiello, J., & Taylor, M. (2023) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2023.105931 · Cited by 5
Li, M., Zeng, Y., Nie, Y., Liao, K., Pei, F., Yang, J., Xie, H., & Shen, B. (2023) · International Journal of Surgery · doi:10.1097/js9.0000000000000810 · Cited by 5
“[36] (E = 6850 r 1.49 ).”
InfluentialPradeep, K., Mahapatra, B., & Pal, B. (2024) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519424500052 · Cited by 5
Impact of heavy alcohol consumption on cortical bone mechanical properties in male rhesus macaques
Shin, M., Kim, D. K., Jain, M., Martens, P. J., Turner, R. T., Iwaniec, U. T., Kruzic, J. J., & Gludovatz, B. (2024) · Bone · doi:10.1016/j.bone.2024.117041 · Cited by 5
Rouyin, A., Einafshar, M. M., & Arjmand, N. (2024) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-024-05169-x · Cited by 6
Zhang, X., Zhang, Y., Huang, S., Qi, X., Li, W., Lv, Y., & Zhu, Z. (2024) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-024-08041-5 · Cited by 5
Activity and Loading Influence the Predicted Bone Remodeling Around Cemented Hip Replacements
Dickinson, A. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4026256 · Cited by 5
Cement Placement Optimization in Femoral Augmentation Using an Evolutionary Algorithm
Basafa, E., & Armand, M. (2013) · IEEE/ASME International Conference on Mechatronic and Embedded Systems and Applications · doi:10.1115/detc2013-13622 · Cited by 5
Relationship between morphological parameters of cancellous bone and its mechanical properties
Syahrom, A., Kadir, M. R. A., & Muslim, D. A.-J. (2010) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2010.5742256 · Cited by 5
“Cancellous bone architecture is highly heterogeneous [12, 13], anisotropic and dependent on skeletal sites due to the difference in external mechanical stimuli [14, 15].”
BackgroundInfluentialNeuert, M., Austman, R. L., & Dunning, C. E. (2013) · PubMed · doi:10.5277/abb130305 · Cited by 6
In-Silico Models of Trabecular Bone: A Sensitivity Analysis Perspective
Mengoni, M., Sikora, S. N. F., D'Otreppe, V., Wilcox, R. K., & Jones, A. C. (2015) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/978-3-319-21296-8_15 · Cited by 5
Cole, J. H., & van der Meulen, M. C. H. (2009) · Humana Press eBooks · doi:10.1007/978-1-59745-459-9_7 · Cited by 10
Metadata
- Authors
- Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 36
- Issue
- 7
- Pages
- 897-904
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2088873760
- Cited by
- 1,209
- References
- 49
- Citations by year
- 2026: 73 · 2025: 72 · 2024: 79 · 2023: 71 · 2022: 78 · 2021: 99 · 2020: 85 · 2019: 59 · 2018: 56 · 2017: 55 · 2016: 61 · 2015: 55 · 2014: 62 · 2013: 43 · 2012: 37
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, elastic modulus, bone mineral density, bone structure, finite element analysis, vertebrae, proximal tibia, femoral neck, power-law regression, bone mechanical properties
- MeSH terms
- Aged, Bone and Bones, Cadaver, Computer Simulation, Elasticity, Female, Femur, Femur Neck, Humans, Lumbar Vertebrae, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Thoracic Vertebrae, Tibia, Reproducibility of Results, Bone Density, Anisotropy, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.