STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 2,201–2,300 of 47,868
Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb,
Linton, N. W. F., & Linton, R. A. F. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/86.4.486 · Cited by 159
Nakamura, M., Darhad, U., Tatsumi, Y., Fujioka, M., Nagai-Kusuhara, A., Maeda, H., & Negi, A. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.02.035 · Cited by 155
Jatoi, N. A., Mahmud, A., Bennett, K., & Feely, J. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e32833057e8 · Cited by 187
Evaluating the quality of dietary intake validation studies
Serra-Majem, L., Frost Andersen, L., Henríque-Sánchez, P., Doreste-Alonso, J., Sánchez-Villegas, A., Ortiz-Andrelluchi, A., Negri, E., & La Vecchia, C. (2009) · British Journal of Nutrition · doi:10.1017/s0007114509993114 · Cited by 156
Corsi, D. J., Subramanian, S. V., Chow, C. K., McKee, M., Chifamba, J., Dagenais, G., Diaz, R., Iqbal, R., Kelishadi, R., Kruger, A., et al. (2013) · American Heart Journal · doi:10.1016/j.ahj.2013.04.019 · Cited by 153
Methodology for High-Throughput Field Phenotyping of Canopy Temperature Using Airborne Thermography
Deery, D. M., Rebetzke, G. J., Jiménez-Berni, J. A., James, R. A., Condon, A. G., Bovill, W. D., Hutchinson, P., Scarrow, J., Davy, R. J., & Furbank, R. T. (2016) · Frontiers in Plant Science · doi:10.3389/fpls.2016.01808 · Cited by 184
Assessment of maximal handgrip strength: how many attempts are needed?
Reijnierse, E. M., de Jong, N., Trappenburg, M. C., Blauw, G. J., Butler‐Browne, G., Gapeyeva, H., Hogrel, J., McPhee, J. S., Narici, M. V., Sipilä, S., et al. (2017) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12181 · Cited by 153
Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit
Villarroel, M., Chaichulee, S., Jorge, J., Davis, S., Green, G., Arteta, C., Zisserman, A., McCormick, K., Watkinson, P., & Tarassenko, L. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0199-5 · Cited by 149
Roberts, D. M., Schade, M. M., Mathew, G. M., Gartenberg, D., & Buxton, O. M. (2020) · Sleep · doi:10.1093/sleep/zsaa045 · Cited by 152
Home, Clinic, and Ambulatory Blood Pressure Monitoring in Children with Chronic Renal Failure
Wühl, E., Gimpel, C., Mehls, O., & Schaefer, F. S. (2003) · Pediatric Research · doi:10.1203/01.pdr.0000106863.90996.76 · Cited by 155
CD45‐assisted Pan Leuco gating for accurate, cost‐effective dual‐platform CD4+ T‐cell enumeration
Glencross, D., Scott, L. E., Jani, I. V., Barnett, D., & Janossy, G. (2002) · Cytometry · doi:10.1002/cyto.10068 · Cited by 158
Energy Expenditure of Walking and Running: Comparison with Prediction Equations
HALL, C., FIGUEROA, A., FERNHALL, B., & KANALEY, J. A. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000147584.87788.0e · Cited by 157
Anwar, A. M., Geleijnse, M. L., Soliman, O. I. I., McGhie, J. S., Frowijn, R., Nemes, A., van den Bosch, A. E., Galema, T. W., & ten Cate, F. J. (2007) · International journal of cardiac imaging · doi:10.1007/s10554-007-9210-3 · Cited by 155
Ector, J., Ganame, J., van der Merwe, N., Adriaenssens, B., Pison, L., Willems, R., Gewillig, M., & Heidbuchel, H. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl468 · Cited by 155
Moal, V., Mathieu, E., Reynier, P., Malthièry, Y., & Gallois, Y. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.07.013 · Cited by 154
Assessment of chest rise during mask ventilation of preterm infants in the delivery room
Poulton, D. A., Schmölzer, G. M., Morley, C. J., & Davis, P. G. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.10.012 · Cited by 154
Dix, L. M. L., van Bel, F., Baerts, W., & Lemmers, P. M. A. (2013) · Pediatric Research · doi:10.1038/pr.2013.133 · Cited by 154
Accuracy of bedside capillary blood glucose measurements in critically ill patients
Critchell, C. D., Savarese, V. W., Callahan, A., Aboud, C., Jabbour, S. A., & Marik, P. E. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0835-4 · Cited by 166
Niki, K., Sugawara, M., Chang, D., Harada, A., Okada, T., Sakai, R., Uchida, K., Tanaka, R., & Mumford, C. E. (2002) · Heart and Vessels · doi:10.1007/s003800200037 · Cited by 156
Yuan, X., Gu, X., Crabb, J. S., Yue, X., Shadrach, K., Hollyfield, J. G., & Crabb, J. W. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900523-mcp200 · Cited by 156
Accuracy and Precision of Noninvasive Temperature Measurement in Adult Intensive Care Patients
Lawson, L., Bridges, E. J., Ballou, I., Eraker, R., Greco, S., Shively, J., & Sochulak, V. (2007) · American Journal of Critical Care · doi:10.4037/ajcc2007.16.5.485 · Cited by 153
Coughlin, M. J., Grimes, J. S., Traughber, P. D., & Jones, C. P. (2006) · Foot & Ankle International · doi:10.1177/107110070602701004 · Cited by 154
Al‐Sheikh, M., Tepelus, T. C., Nazikyan, T., & Sadda, S. R. (2016) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-308764 · Cited by 154
Tan, G. D., Lewis, A. V., James, T. J., Altmann, P., Taylor, R. P., & Lévy, J. (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2004 · Cited by 154
Gödje, O. L., Peyerl, M., Seebauer, T., Dewald, O., & Reichart, B. (1998) · CHEST Journal · doi:10.1378/chest.113.4.1070 · Cited by 154
Suzuki, S., Oshika, T., Oki, K., Sakabe, I., Iwase, A., Amano, S., & Araie, M. (2003) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(03)00123-8 · Cited by 154
Jones, A. W., & Andersson, L. (2003) · Forensic Science International · doi:10.1016/s0379-0738(02)00417-6 · Cited by 165
Bruynesteyn, K., van der Heijde, D., Boers, M., Saudan, A., Peloso, P., Paulus, H., Houben, H., Griffiths, B., Edmonds, J., Bresnihan, B., et al. (2002) · Arthritis & Rheumatism · doi:10.1002/art.10190 · Cited by 153
Barbier, N., Paul, C., Luger, T., Allen, R., De Prost, Y., Papp, K., Eichenfield, L. F., Cherill, R., & Hanifin, J. (2004) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2004.05696.x · Cited by 153
Sardinha, L. B., Lohman, T. G., Teixeira, P. J., Guedes, D. P., & Going, S. B. (1998) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/68.4.786 · Cited by 189
Sabbá, C., Weltin, G. G., Cicchetti, D. V., Ferraioli, G., Taylor, K. J. W., Nakamura, T., Moriyasu, F., & Groszmann, R. J. (1990) · Gastroenterology · doi:10.1016/0016-5085(90)91097-p · Cited by 160
Determination of Human Coronary Artery Composition by Raman Spectroscopy
Brennan, J. F., Römer, T. J., Lees, R. S., Tercyak, A. M., Kramer, J. R., & Feld, M. S. (1997) · Circulation · doi:10.1161/01.cir.96.1.99 · Cited by 154
El-Khoury, A., Fukagawa, N., Sánchez, M., Tsay, R., Gleason, R., Chapman, T., & Young, V. (1994) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/59.5.1000 · Cited by 153
Rovaris, M., Filippi, M., Calori, G., Rodegher, M., Campi, A., Colombo, B., & Comi, G. (1997) · Journal of Neurology · doi:10.1007/s004150050083 · Cited by 158
Haugeberg, G., Ørstavik, R. E., Uhlig, T., Falch, J. A., Halse, J. I., & Kvien, T. K. (2002) · Arthritis & Rheumatism · doi:10.1002/art.10408 · Cited by 153
Khan, E., Al Hossain, F., Uddin, S. Z., Alam, S. K., & Hasan, M. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466075 · Cited by 153
Variability in vitamin D assays impairs clinical assessment of vitamin D status
Lai, J. K. C., Lucas, R. M., Banks, E., Ponsonby, A., & Ausimmune Investigator Group (2011) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2011.02471.x · Cited by 159
Nagai, M., Hoshide, S., Ishikawa, J., Shimada, K., & Kario, K. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283018333 · Cited by 154
Rapid Assessment of Sleep-Wake Behavior in Mice
Fisher, S. P., Godinho, S. I. H., Pothecary, C. A., Hankins, M. W., Foster, R. G., & Peirson, S. N. (2012) · Journal of Biological Rhythms · doi:10.1177/0748730411431550 · Cited by 156
Assessment of Morphological MRI for Pulmonary Changes in Cystic Fibrosis (CF) Patients
Puderbach, M., Eichinger, M., Haeselbarth, J., Ley, S., Kopp‐Schneider, A., Tuengerthal, S., Schmähl, A., Fink, C., Plathow, C., Wiebel, M., et al. (2007) · Investigative Radiology · doi:10.1097/rli.0b013e318074fd81 · Cited by 153
Bohu, Y., Klouche, S., Lefevre, N., Webster, K., & Herman, S. (2015) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-014-2942-4 · Cited by 153
Assessing disordered speech and voice in Parkinson's disease: a telerehabilitation application
Constantinescu, G., Theodoros, D., Russell, T., Ward, E., Wilson, S., & Wootton, R. (2010) · International Journal of Language & Communication Disorders · doi:10.3109/13682820903470569 · Cited by 152
Peebles, K. C., Celi, L. A., McGrattan, K., Murrell, C., Thomas, K. N., & Ainslie, P. N. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.137075 · Cited by 153
Objective cough frequency in Idiopathic Pulmonary Fibrosis
Key, A. L., Holt, K. J., Hamilton, A., Smith, J. A., & Earis, J. E. (2010) · Cough · doi:10.1186/1745-9974-6-4 · Cited by 153
The Urticaria Activity Score—Validity, Reliability, and Responsiveness
Hawro, T., Ohanyan, T., Schoepke, N., Metz, M., Peveling‐Oberhag, A., Staubach, P., Maurer, M., & Weller, K. (2017) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2017.10.001 · Cited by 180
Morin, J.-B., Samozino, P., Murata, M., Cross, M. R., & Nagahara, R. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.07.020 · Cited by 169
Deep Learning Reconstruction of Diffusion-weighted MRI Improves Image Quality for Prostatic Imaging
Ueda, T., Ohno, Y., Yamamoto, K., Murayama, K., Ikedo, M., Yui, M., Hanamatsu, S., Tanaka, Y., Obama, Y., Ikeda, H., et al. (2022) · Radiology · doi:10.1148/radiol.204097 · Cited by 168
SimplyAgree: An R package and jamovi Module for Simplifying Agreement and Reliability Analyses
Caldwell, A. R. (2022) · The Journal of Open Source Software · doi:10.21105/joss.04148 · Cited by 180
Nishimura, R. A., Rihal, C. S., Tajik, A. J., & Holmes, D. R. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90556-8 · Cited by 153
Pirie, R. S., Collie, D., Dixon, P. M., & McGorum, B. C. (2003) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.2003.01640.x · Cited by 153
Luoto, S., Taimela, S., Hurri, H., Aalto, H., Pyykkö, I., & Alaranta, H. (1996) · Spine · doi:10.1097/00007632-199611150-00012 · Cited by 153
Z‐scores of the fetal aortic isthmus and duct: an aid to assessing arch hypoplasia
Pasquini, L., Mellander, M., Seale, A. N., Matsui, H., Roughton, M., Ho, S. Y., & Gardiner, H. M. (2007) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.4021 · Cited by 153
Keller, A., Hellesnes, J., & Jens I. Brox, A. (2001) · Spine · doi:10.1097/00007632-200104010-00017 · Cited by 152
Regional Changes in Choroidal Thickness Associated With Accommodation
Woodman‐Pieterse, E. C., Read, S. A., Collins, M. J., & Alonso‐Caneiro, D. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-17102 · Cited by 162
Extraction of Heart Rate Variability from Smartphone Photoplethysmograms
Peng, R.-C., Zhou, X.-L., Lin, W.-H., & Zhang, Y.-T. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/516826 · Cited by 149
Heijtel, D., Mutsaerts, H. J. M. M., Bakker, E. D. M., Schober, P. R., Stevens, M. F., Petersen, E. T., van Berckel, B. N. M., Majoie, C. B. L. M., Booij, J., van Osch, M. J. P., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.011 · Cited by 156
Beltran, C. J., Herman, M., & Davis, B. J. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.08.040 · Cited by 155
Valdés Hernández, M. D. C., Ferguson, K. J., Chappell, F. M., & Wardlaw, J. M. (2010) · European Radiology · doi:10.1007/s00330-010-1718-6 · Cited by 155
Test-retest and alternate forms reliability of the assisting hand assessment
Holmefur, M., Aarts, P. B. M., Hoare, B., & Krumlinde‐Sundholm, L. (2009) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0448 · Cited by 178
Hofer, C. K., Ganter, M. T., Tucci, M., Klaghofer, R., & Zollinger, A. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.2.283 · Cited by 152
Strauss, D. G., Selvester, R. H. S., Lima, J. A. C., Arheden, H., Miller, J. M., Gerstenblith, G., Marbán, E., Weiss, R. G., Tomaselli, G. F., Wagner, G. S., et al. (2008) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.798660 · Cited by 154
Intra- and Interrater Reliability of Ultrasound Assessment of Gastric Volume
Kruisselbrink, R., Arzola, C., Endersby, R., Tse, C., Chan, V., & Perlas, A. (2014) · Anesthesiology · doi:10.1097/aln.0000000000000193 · Cited by 151
Comparison of methods to assess change in children's body composition
Elberg, J., McDuffie, J. R., Sebring, N. G., Salaita, C. G., Keil, M. F., Robotham, D., Reynolds, J. C., & Yanovski, J. A. (2004) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/80.1.64 · Cited by 152
Pouleur, A., de Waroux, J. L. P., Pasquet, A., Vanoverschelde, J., & Gerber, B. L. (2007) · Radiology · doi:10.1148/radiol.2443061127 · Cited by 152
González‐Torrecilla, E., Arenal, Á., Atienza, F., Osca, J., Fernandez, F., Puchol, A., Sánchez, A., & Almendral, J. M. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.02.019 · Cited by 152
Hardy, J., Hall, C. R., & Hardy, L. (2005) · Journal of Sports Sciences · doi:10.1080/02640410500130706 · Cited by 151
The validity of wireless iButtons® and thermistors for human skin temperature measurement
Smith, A. D. H., Crabtree, D. R., Bilzon, J. L. J., & Walsh, N. P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/007 · Cited by 153
Dweck, M. R., Khaw, H. J., Sng, G. K. Z., Luo, E. L. C., Baird, A., Williams, M. C., Makiello, P., Mirsadraee, S., Joshi, N. V., van Beek, E. J. R., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht034 · Cited by 152
Schoemaker, D., Buss, C., Head, K., Sandman, C. A., Davis, E. P., Chakravarty, M. M., Gauthier, S., & Pruessner, J. C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.01.038 · Cited by 154
Saugel, B., Grothe, O., & Wagner, J. Y. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000725 · Cited by 163
Zehner, N., Umstätter, C., Niederhauser, J. J., & Schick, M. (2017) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2017.02.021 · Cited by 181
A Portable Wearable Tele-ECG Monitoring System
Özkan, H., Özhan, O., Karadana, Y., Gulcu, M., Macit, S., & Husain, F. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2895484 · Cited by 153
Arshad, U., Pertinez, H. E., Box, H., Tatham, L. M., Rajoli, R. K. R., Curley, P., Neary, M., Sharp, J., Liptrott, N. J., Valentijn, A., et al. (2020) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1909 · Cited by 162
Charlton, P. H., Paliakaitė, B., Pilt, K., Bachler, M., Zanelli, S., Kulin, D., Allen, J., Hallab, M., Bianchini, E., Mayer, C. C., et al. (2021) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00392.2021 · Cited by 201
Quality of life in pre-adolescence: A 17-dimensional health-related measure (17D)
Apajasalo, M., Rautonen, J., Holmberg, C., Sinkkonen, J., Aalberg, V., Pihko, H. S., Siimes, M. A., Kaitila, I., M�kel�, A. L., Erkkil�, K., et al. (1996) · Quality of Life Research · doi:10.1007/bf00439227 · Cited by 152
Hofman, M. B. M., Visser, F. C., van Rossum, A. C., Vink, G. Q. M., Sprenger, M., & Westerhof, N. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330606 · Cited by 152
How Valid Are Family Proxy Assessments of Stroke Patients’ Health-Related Quality of Life?
Williams, L. S., Bakas, T., Brizendine, E., Plue, L., Tu, W., Hendrie, H., & Kroenke, K. (2006) · Stroke · doi:10.1161/01.str.0000230583.10311.9f · Cited by 153
Fowler, P., Casey, C., Cameron, G. G., Foster, M., & KNIGHT, C. H. (1990) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1990.tb02546.x · Cited by 152
Echocardiographic criteria for detection of postinfarction congestive heart failure in rats
Sjaastad, I., Sejersted, O. M., Ilebekk, A., & Bjørnerheim, R. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1445 · Cited by 152
Lucía, A., Sánchez, O., Carvajal, A., & Chicharro, J. L. (1999) · British Journal of Sports Medicine · doi:10.1136/bjsm.33.3.178 · Cited by 153
Feasibility of tissue magnetic resonance imaging
Paelinck, B. P., Roos, A., Bax, J. J., Bosmans, J. M., van der Geest, R. J., Dhondt, D., Parizel, P. M., Vrints, C. J., & Lamb, H. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.12.051 · Cited by 152
Value of caregiver ratings in evaluating the quality of life of patients with cancer.
Sneeuw, K. C., Aaronson, N. K., Sprangers, M. A., Detmar, S. B., Wever, L. D., & Schornagel, J. H. (1997) · Journal of Clinical Oncology · doi:10.1200/jco.1997.15.3.1206 · Cited by 153
Haghayegh, S., Kang, H.-A., Khoshnevis, S., Smolensky, M. H., & Diller, K. R. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab86d6 · Cited by 152
Wang, Z., Pi-Sunyer, F. X., Kotler, D. P., Wielopolski, L., Withers, R. T., Pierson, R. N., & Heymsfield, S. B. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.5.968 · Cited by 151
Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151
Chew, M. S., & Poelaert, J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1967-9 · Cited by 151
Online dietary intake estimation: the Food4Me food frequency questionnaire
Forster, H., Fallaize, R., Gallagher, C., O’Donovan, C. B., Woolhead, C., Walsh, M. C., Macready, A. L., Lovegrove, J. A., Mathers, J. C., Gibney, M. J., et al. (2014) · Journal of Medical Internet Research · doi:10.2196/jmir.3105 · Cited by 151
Kono, Y., Yonemoto, N., Kusuda, S., Hirano, S., Iwata, O., Tanaka, K., & Nakazawa, J. (2015) · Brain and Development · doi:10.1016/j.braindev.2015.10.010 · Cited by 160
Magarey, A., Golley, R. K., Spurrier, N. J., Goodwin, E., & Ong, F. (2009) · International Journal of Pediatric Obesity · doi:10.3109/17477160902846161 · Cited by 151
Flansbjer, U., Blom, J., & Brogårdh, C. B. (2012) · PM&R · doi:10.1016/j.pmrj.2011.11.004 · Cited by 158
Estimation of Total-Body Skeletal Muscle Mass in Children and Adolescents
POORTMANS, J. R., Boisseau, N., Moraine, J.-J., Moreno‐Reyes, R., & Goldman, S. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000152804.93039.ce · Cited by 183
Test–retest reliability of P50, N100 and P200 auditory sensory gating in healthy subjects
Rentzsch, J., Jockers-Scherübl, M. C., Boutros, N. N., & Gallinat, J. (2007) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2007.10.006 · Cited by 173
Hatt, M., Visvikis, D., Albarghach, N. M., Tixier, F., Pradier, O., & Rest, C. C. L. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1755-7 · Cited by 151
Müller, C., Schillert, A., Röthemeier, C., Trégouët, D.-A., Proust, C., Binder, H., Pfeiffer, N., Beutel, M., Lackner, K. J., Schnabel, R. B., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0156594 · Cited by 150
Reliability and Validity of the Belt-Stabilized Handheld Dynamometer in Hip- and Knee-Strength Tests
Martins, J., da Silva, J. R., da Silva, M. R. B., & Bevilaqua‐Grossi, D. (2017) · Journal of Athletic Training · doi:10.4085/1062-6050-52.6.04 · Cited by 184
Beusen, A. H. W., Bouwman, L., Dürr, H. H., Dekkers, A. L. M., & Hartmann, J. (2009) · Global Biogeochemical Cycles · doi:10.1029/2008gb003281 · Cited by 172
Personal Use of Hair Dyes and Risk of Cancer
Takkouche, B., Etminan, M., & Montes, A. (2005) · JAMA · doi:10.1001/jama.293.20.2516 · Cited by 151
Fürstenberg, A., & Davenport, A. (2011) · American Journal of Nephrology · doi:10.1159/000324111 · Cited by 162
Stavem, K. (1999) · Quality of Life Research · doi:10.1023/a:1026475531996 · Cited by 166
Damsgaard, C. T., Lauritzen, L., Calder, P. C., Kjær, T., & Frøkiær, H. (2008) · Journal of Immunological Methods · doi:10.1016/j.jim.2008.10.005 · Cited by 169
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.