STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 2,001–2,100 of 47,868
Reliability of gait speed measured by a timed walking test in patients one year after stroke
Green, J., Forster, A., & Young, J. (2002) · Clinical Rehabilitation · doi:10.1191/0269215502cr495oa · Cited by 164
Fogo, A. B., Bostad, L., Svarstad, E., Cook, W. J., Moll, S., Barbey, F., Geldenhuys, L., West, M., Ferluga, D., Vujkovac, B., et al. (2010) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp528 · Cited by 165
Karita, E., Ketter, N., Price, M. A., Kayitenkore, K., Kaleebu, P., Nanvubya, A., Anzala, O., Jaoko, W., Mutua, G., Ruzagira, E., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004401 · Cited by 167
Thomas, E. J., Williams, A. L., Reichman, E. F., Lasky, R. E., Crandell, S., & Taggart, W. R. (2010) · Pediatrics · doi:10.1542/peds.2009-1635 · Cited by 166
MFP-Unet: A novel deep learning based approach for left ventricle segmentation in echocardiography
Moradi, S., Oghli, M. G., Alizadehasl, A., Shiri, I., Oveisi, N., Oveisi, M., Maleki, M., & Dhooge, J. (2019) · Physica Medica · doi:10.1016/j.ejmp.2019.10.001 · Cited by 164
Measurement of gastric emptying by magnetic resonance imaging in humans
Schwizer, W., Maecke, H., & Michael, F. (1992) · Gastroenterology · doi:10.1016/0016-5085(92)90823-h · Cited by 165
Characterization of Dysfunctional Myocardium by Positron Emission Tomography and Magnetic Resonance
Knüsel, P. R., Nanz, D., Wyss, C. A., Buechi, M., Kaufmann, P. A., von Schulthess, G. K., Lüscher, T. F., & Schwitter, J. (2003) · Circulation · doi:10.1161/01.cir.0000085993.93936.ba · Cited by 165
Woermann, F. G., Barker, G. J., Birnie, K. D., Meencke, H. J., & Duncan, J. S. (1998) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.65.5.656 · Cited by 166
CARRERA, M., BARBÉ, F., SAULEDA, J., TOMÁS, M., GÓMEZ, C., & AGUSTÍ, A. G. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.6.9809052 · Cited by 168
Oerlemans, H. M., Oostendorp, R. A. B., de Boo, T., van der Laan, L., Severens, J. L., & Goris, R. J. A. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(00)90221-1 · Cited by 170
Who's afraid of informed consent?
Kerrigan, D. D., Thevasagayam, R. S., Woods, T. O., Mc Welch, I., Thomas, W. E., Shorthouse, A. J., & Dennison, A. R. (1993) · BMJ · doi:10.1136/bmj.306.6873.298 · Cited by 168
Williams, K. A., Sr., & Taillon, L. A. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00413-0 · Cited by 165
Thavasothy, M., Broadhead, M., Elwell, C., Peters, M., & Smith, M. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02826.x · Cited by 165
Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/309 · Cited by 164
Rochon, J., Protiva, P., Seeff, L. B., Fontana, R. J., Liangpunsakul, S., Watkins, P. B., Davern, T., & McHutchison, J. G. (2008) · Hepatology · doi:10.1002/hep.22442 · Cited by 164
Haecker, I., Gay, L. A., Yang, Y., Hu, J., Morse, A. M., McIntyre, L. M., & Renne, R. (2012) · PLoS Pathogens · doi:10.1371/journal.ppat.1002884 · Cited by 166
Gender differences in 3D morphology and bony impingement of human hips
NAKAHARA, I., Takao, M., Sakai, T., Nishii, T., Yoshikawa, H., & Sugano, N. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21265 · Cited by 164
Aminian, K., Trevisan, C., Najafi, B., Dejnabadi, H., Frigo, C., Pavan, E., Telonio, A., Cerati, F., Marinoni, E. C., Robert, P., et al. (2004) · Gait & Posture · doi:10.1016/s0966-6362(03)00093-6 · Cited by 164
Waterval, W. A. H., Scheijen, J. L. J. M., Ortmans-Ploemen, M. M. J. C., Habets-van der Poel, C. D., & Bierau, J. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.06.023 · Cited by 164
The validity of activity monitors for measuring sleep in elite athletes
Sargent, C., Lastella, M., Halson, S. L., & Roach, G. D. (2016) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2015.12.007 · Cited by 165
Alam, S. R., Shah, A. S. V., Richards, J., Lang, N. N., Barnes, G., Joshi, N., MacGillivray, T., McKillop, G., Mirsadraee, S., Payne, J., et al. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.974907 · Cited by 163
Validation of enhanced kinect sensor based motion capturing for gait assessment
Müller, B., Ilg, W., Giese, M. A., & Ludolph, N. (2017) · PLoS ONE · doi:10.1371/journal.pone.0175813 · Cited by 164
Accuracy of a New Robotically Assisted Technique for Total Knee Arthroplasty: A Cadaveric Study
Parratte, S., Price, A. J., Jeys, L. M., Jackson, W. F., & Clarke, H. D. (2019) · The Journal of Arthroplasty · doi:10.1016/j.arth.2019.06.040 · Cited by 164
Appearance scales to measure cosmetic outcomes of healed lacerations
Quinn, J. V., Drzewiecki, A. E., Stiell, I. G., & Elmslie, T. J. (1995) · The American Journal of Emergency Medicine · doi:10.1016/0735-6757(95)90100-0 · Cited by 165
Mattiasson, A., Djurhuus, J. C., Fonda, D., Lose, G., Nordling, J., & Stohrer, M. (1998) · Neurourology and Urodynamics · doi:10.1002/(sici)1520-6777(1998)17:3<197::aid-nau4>3.0.co;2-8 · Cited by 120
Buck, T., Hunold, P., Wentz, K. U., Tkalec, W., Nesser, H. J., & Erbel, R. M. (1997) · Circulation · doi:10.1161/01.cir.96.12.4286 · Cited by 164
Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal population
Fernandes, P., Díaz‐Rey, J. A., Queirós, A., Gonzalez‐Meijome, J. M., & Jorge, J. (2005) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2005.00327.x · Cited by 167
Idiopathic focal dystonia: a disorder of muscle spindle afferent processing?
Grunewald, R. (1997) · Brain · doi:10.1093/brain/120.12.2179 · Cited by 165
Kim, Y. Y., Klein, A. L., Halliburton, S. S., Popovic, Z. B., Kuzmiak, S. A., Sola, S., Garcia, M. J., Schoenhagen, P., Natale, A., & Desai, M. Y. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.08.004 · Cited by 166
Percent body fat via DEXA: comparison with a four-compartment model
van der Ploeg, G. E., Withers, R. T., & Laforgia, J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00436.2002 · Cited by 163
Relative validation of Block Kids Food Screener for dietary assessment in children and adolescents
Hunsberger, M., O'Malley, J., Block, T., & Norris, J. C. (2015) · Maternal & Child Nutrition · doi:10.1111/j.1740-8709.2012.00446.x · Cited by 158
Accuracy of Noncycloplegic Autorefraction in School-Age Children in China
Zhao, J., Mao, J., Luo, R., Li, F., Pokharel, G. P., & Ellwein, L. B. (2004) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2004.tb02851.x · Cited by 163
Westwood, M. A., Anderson, L. J., Firmin, D. N., Gatehouse, P. D., Lorenz, C. H., Wonke, B., & Pennell, D. J. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10396 · Cited by 166
Noncontact imaging photoplethysmography to effectively access pulse rate variability
Sun, Y., Hu, S., Azorin-Peris, V., Kalawsky, R., & Greenwald, S. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061205 · Cited by 164
Presymptomatic spondylotic cervical myelopathy: an updated predictive model
Bednarik, J., Kadanka, Z., Dusek, L., Kerkovsky, M., Vohanka, S., Novotny, O., Urbanek, I., & Kratochvilova, D. (2008) · European Spine Journal · doi:10.1007/s00586-008-0585-1 · Cited by 163
Lynch, M., Ghita, O., & Whelan, P. F. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904681 · Cited by 164
Validity of predictive equations for 24-h urinary sodium excretion in adults aged 18–39 y
Cogswell, M. E., Wang, C.-Y., Chen, T.-C., Pfeiffer, C. M., Elliott, P., Gillespie, C. D., Carriquiry, A. L., Sempos, C. T., Liu, K., Perrine, C. G., et al. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.113.059436 · Cited by 165
Schmitz, A., Ye, M., Shapiro, R., Yang, R., & Noehren, B. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.11.031 · Cited by 160
Corstjens, A. M., Ligtenberg, J. J., van der Horst, I. C., Spanjersberg, R., Lind, J. S., Tulleken, J. E., Meertens, J. H., & Zijlstra, J. G. (2006) · Critical Care · doi:10.1186/cc5048 · Cited by 163
Bountziouka, V., Bathrellou, E., Giotopoulou, A., Katsagoni, C., Bonou, M., Vallianou, N., Barbetseas, J., Avgerinos, P. C., & Panagiotakos, D. B. (2012) · Nutrition, Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2010.10.015 · Cited by 161
Development and validation of assay protocols for use with dried blood spot samples
McDade, T. W. (2014) · American Journal of Human Biology · doi:10.1002/ajhb.22463 · Cited by 164
Verkerk, G. J. Q., Wolf, M., Louwers, A., Meester‐Delver, A., & Nollet, F. (2006) · Clinical Rehabilitation · doi:10.1177/0269215506070703 · Cited by 163
Validation of the Telephone and In-Person Interview Versions of the 7-Day PAR
HAYDEN-WADE, H. A., COLEMAN, K. J., SALLIS, J. F., & ARMSTRONG, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064941.43869.4e · Cited by 164
Quantitation of cardiac output with velocity-encoded, phase-difference magnetic resonance imaging
Hundley, W. G., Li, H. F., Hillis, L. D., Meshack, B. M., Lange, R. A., Willard, J. E., Landau, C., & Peshock, R. M. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80772-3 · Cited by 163
Validation of the Finometer device for measurement of blood pressure in black women
Schutte, A. E., Huisman, H. W., van Rooyen, J. M., Malan, N. T., & Schutte, R. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001639 · Cited by 164
Stroke volume equation for impedance cardiography
Bernstein, D. P., & Lemmens, H. J. M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344724 · Cited by 165
Stewart, G. A., Foster, J., Cowan, M., Rooney, E., Mcdonagh, T., Dargie, H. J., Rodger, R. S. C., & Jardine, A. G. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00786.x · Cited by 164
Marik, P. E. (2001) · Chest · doi:10.1378/chest.120.3.923 · Cited by 170
Muthurangu, V., Taylor, A., Andriantsimiavona, R., Hegde, S., Miquel, M. E., Tulloh, R., Baker, E., Hill, D. L. G., & Razavi, R. S. (2004) · Circulation · doi:10.1161/01.cir.0000138741.72946.84 · Cited by 165
Lehmann, E. D., Hopkins, K. D., Rawesh, A., Joseph, R. C., Kongola, K., Coppack, S. W., & Gosling, R. G. (1998) · Hypertension · doi:10.1161/01.hyp.32.3.565 · Cited by 162
Bank, A. J., Wilson, R. F., Kubo, S. H., Holte, J. E., Dresing, T. J., & Wang, H. (1995) · Circulation Research · doi:10.1161/01.res.77.5.1008 · Cited by 164
Mesenteric, coeliac and splanchnic blood flow in humans during exercise
Perko, M. J., Nielsen, H. B., Skak, C., Clemmesen, J. O., Schroeder, T. V., & Secher, N. H. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.907ba.x · Cited by 162
Signal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate Measurements
Droitcour, A. D., Boric-Lubecke, O., & Kovacs, G. T. A. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029668 · Cited by 162
du Prel, J.-B., Röhrig, B., Hommel, G., & Blettner, M. (2010) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2010.0343 · Cited by 161
Kaplan, K. A., Talbot, L. S., Gruber, J., & Harvey, A. G. (2012) · Bipolar Disorders · doi:10.1111/bdi.12021 · Cited by 161
Sezgi˙n, M., İncel, N. A., Sevi˙m, S., Çamdevi˙ren, H., As, İ., & ErdoĞan, C. (2006) · Disability and Rehabilitation · doi:10.1080/09638280600621469 · Cited by 163
Diurnal variation of serum and urine biomarkers in patients with radiographic knee osteoarthritis
Kong, S. Y., Stabler, T. V., Criscione, L. G., Elliott, A. L., Jordan, J. M., & Kraus, V. B. (2006) · Arthritis & Rheumatism · doi:10.1002/art.21977 · Cited by 160
Patient-Nurse Interrater Reliability and Agreement of the Richards-Campbell Sleep Questionnaire
Kamdar, B. B., Shah, P. A., King, L. M., Kho, M. E., Zhou, X., Colantuoni, E., Collop, N. A., & Needham, D. M. (2012) · American Journal of Critical Care · doi:10.4037/ajcc2012111 · Cited by 159
Change in the number of musculoskeletal pain sites: A 14-year prospective study
Kamaleri, Y., Natvig, B., Ihlebaek, C. M., Benth, J. S., & Bruusgaard, D. (2009) · Pain · doi:10.1016/j.pain.2008.09.013 · Cited by 163
Evaluating bone collagen extraction methods for stable isotope analysis in dietary studies
Jørkov, M. L. S., Heinemeier, J., & Lynnerup, N. (2007) · Journal of Archaeological Science · doi:10.1016/j.jas.2006.12.020 · Cited by 164
The Influence of Corneal Properties on Rebound Tonometry
Chui, W.-S., Lam, A., Chen, D., & Chiu, R. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.03.061 · Cited by 163
PC-PVT: A platform for psychomotor vigilance task testing, analysis, and prediction
Khitrov, M. Y., Laxminarayan, S., Thorsley, D., Ramakrishnan, S., Rajaraman, S., Wesensten, N. J., & Reifman, J. (2014) · Behavior Research Methods · doi:10.3758/s13428-013-0339-9 · Cited by 162
Rietberg, M. B., Van Wegen, E. E. H., & Kwakkel, G. (2010) · Disability and Rehabilitation · doi:10.3109/09638281003734458 · Cited by 165
Antony, G. M., & Rao, K. V. (2007) · Public Health · doi:10.1016/j.puhe.2006.10.018 · Cited by 162
A practical guide to validation and verification of analytical methods in the clinical laboratory
Pum, J. K. W. (2019) · Advances in clinical chemistry · doi:10.1016/bs.acc.2019.01.006 · Cited by 221
Conventional or physicochemical approach in intensive care unit patients with metabolic acidosis
Moviat, M., van Haren, F., & van der Hoeven, J. (2003) · Critical Care · doi:10.1186/cc2184 · Cited by 171
The relationship between mandibular bone mineral density and panoramic radiographic measurements
Horner, K., & Devlin, H. (1998) · Journal of Dentistry · doi:10.1016/s0300-5712(97)00020-1 · Cited by 160
Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
Kamel, E. M., Burger, C., Buck, A., von Schulthess, G. K., & Goerres, G. W. (2003) · European Radiology · doi:10.1007/s00330-002-1564-2 · Cited by 163
Biaggi, R. R., Vollman, M. W., Nies, M. A., Brener, C. E., Flakoll, P. J., Levenhagen, D. K., Sun, M., Karabulut, Z., & Chen, K. Y. (1999) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/69.5.898 · Cited by 163
Manton, D. J., Chaturvedi, A., Hubbard, A., Lind, M., Lowry, M., Maraveyas, A., Pickles, M. D., Tozer, D. J., & Turnbull, L. (2006) · British Journal of Cancer · doi:10.1038/sj.bjc.6603165 · Cited by 162
Validity of dietary assessment in athletes: a systematic review
Capling, L., Beck, K., Gifford, J., Slater, G., Flood, V., & O’Connor, H. (2017) · Nutrients · doi:10.3390/nu9121313 · Cited by 161
Malmberg, L. P., Pelkonen, A. S., Poussa, T. A., Pohjanpalo, A., Haahtela, T., & Turpeinen, M. (2002) · Clinical Physiology · doi:10.1046/j.1475-097x.2002.00396.x · Cited by 161
Lamhaut, L., Apriotesei, R., Combes, X., Lejay, M., Carli, P., & Vivien, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182270c22 · Cited by 160
Bartoli, M. L., Novelli, F., Costa, F., Malagrinò, L., Melosini, L., Bacci, E., Cianchetti, S., Dente, F. L., Di Franco, A., Vagaggini, B., et al. (2011) · Mediators of Inflammation · doi:10.1155/2011/891752 · Cited by 160
A comparison of three methods for estimating height in the acutely ill elderly population
Hickson, M., & Frost, G. (2003) · Journal of Human Nutrition and Dietetics · doi:10.1046/j.1365-277x.2003.00416.x · Cited by 161
Concurrent Validity of Vertical Jump Performance Assessment Systems
Castagna, C., Ganzetti, M., Ditroilo, M., Giovannelli, M., Rocchetti, A., & Manzi, V. (2012) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31825dbcc5 · Cited by 205
Holm, I., Bolstad, B., Lütken, T., Ervik, A., Røkkum, M., & Steen, H. (2000) · Physiotherapy Research International · doi:10.1002/pri.204 · Cited by 164
A grey zone for quantitative diagnostic and screening tests
Coste, J., & Pouchot, J. (2003) · International Journal of Epidemiology · doi:10.1093/ije/dyg054 · Cited by 161
An analysis of the learning curve to achieve competency at colonoscopy using the JETS database
Ward, S. T., Mohammed, M. A., Walt, R., Valori, R., Ismail, T., & Dunckley, P. (2014) · Gut · doi:10.1136/gutjnl-2013-305973 · Cited by 160
de Hoop, B., Gietema, H., van Ginneken, B., Zanen, P., Groenewegen, G., & Prokop, M. (2009) · European Radiology · doi:10.1007/s00330-008-1229-x · Cited by 159
Episiotomy characteristics and risks for obstetric anal sphincter injuries: a case‐control study
Stedenfeldt, M., PIRHONEN, J. P., Blix, E., Wilsgaard, T., Vonen, B., & Øian, P. (2012) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2012.03293.x · Cited by 161
Shweta, Bajpai, R. C., & Chaturvedi, H. (2015) · Journal of the Indian Academy of Applied Psychology · Cited by 292
The variability of the apnoea–hypopnoea index
Bittencourt, L. R. A., Suchecki, D., Tufik, S., Peres, C., Togeiro, S. M., Bagnato, M. D. C., & Nery, L. E. (2001) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2001.00255.x · Cited by 160
Safety and Reproducibility of Sputum Induction in Asthmatic Subjects in a Multicenter Study
FAHY, J. V., BOUSHEY, H. A., LAZARUS, S. C., MAUGER, E. A., CHERNIACK, R. M., CHINCHILLI, V. M., CRAIG, T. J., DRAZEN, J. M., FORD, J. G., FISH, J. E., et al. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.9901105 · Cited by 163
Ethnic Differences in Insulin Resistance and Body Composition in United Kingdom Adolescents
Ehtisham, S., Crabtree, N., Clark, P., Shaw, N., & Barrett, T. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-2001 · Cited by 160
Assessment of Coronary Arterial Flow and Flow Reserve in Humans With Magnetic Resonance Imaging
Hundley, W. G., Lange, R. A., Clarke, G. D., Meshack, B. M., Payne, J., Landau, C., McColl, R., Sayad, D. E., Willett, D. L., Willard, J. E., et al. (1996) · Circulation · doi:10.1161/01.cir.93.8.1502 · Cited by 161
In Vivo Human Brachial Artery Elastic Mechanics: Effects of Smooth Muscle Relaxation
Bank, A. J., Kaiser, D. R., Rajala, S., & Cheng, A. (1999) · Circulation · doi:10.1161/01.cir.100.1.41 · Cited by 159
Different Methods of Creatinine Measurement Significantly Affect MELD Scores
Cholongitas, E., Marelli, L., Kerry, A., Senzolo, M., Goodier, D. W., Nair, D., Thomas, M., Patch, D., & Burroughs, A. K. (2007) · Liver Transplantation · doi:10.1002/lt.20994 · Cited by 162
Piccoli, A., Brunani, A., Savia, G., Pillon, L., Favaro, E., Berselli, M., & Cavagnini, F. (1998) · International Journal of Obesity · doi:10.1038/sj.ijo.0800551 · Cited by 163
Grau, T., Leipold, R. W., Conradi, R., Martin, E., & Motsch, J. (2001) · Regional Anesthesia & Pain Medicine · doi:10.1053/rapm.2001.19633 · Cited by 161
Alternatives to polysomnography (PSG): a validation of wrist actigraphy and a partial-PSG system
Kosmadopoulos, A., Sargent, C., Darwent, D., Zhou, X., & Roach, G. D. (2014) · Behavior Research Methods · doi:10.3758/s13428-013-0438-7 · Cited by 160
A Comparison of the INVOS 4100 and the NIRO 300 Near-Infrared Spectrophotometers
Yoshitani, K., Kawaguchi, M., Tatsumi, K., Kitaguchi, K., & Furuya, H. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200203000-00020 · Cited by 162
Magnification chromoendoscopy for the diagnosis of gastric intestinal metaplasia and dysplasia
Dinis-Ribeiro, M., da Costa-Pereira, A., Lopes, C., Lara-Santos, L., Guilherme, M., Moreira-Dias, L., Lomba-Viana, H., Ribeiro, A., Santos, C., Soares, J., et al. (2003) · Gastrointestinal Endoscopy · doi:10.1067/mge.2003.145 · Cited by 163
Measurement of EMG activity with textile electrodes embedded into clothing
Finni, T., Hu, M., Kettunen, P., Vilavuo, T., & Cheng, S. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/007 · Cited by 160
Ahn, S., Park, S. H., & Lee, K. H. (2013) · Radiology · doi:10.1148/radiol.12120725 · Cited by 159
Park, D.-S., & Lee, G. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-99 · Cited by 160
Terwee, C. B., Mokkink, L. B., Steultjens, M. P. M., & Dekker, J. (2006) · Rheumatology · doi:10.1093/rheumatology/kei267 · Cited by 164
Continuous thermodilution cardiac output measurement in intensive care unit patients
Yelderman, M., Ramsay, M. A., Quinn, M. D., Paulsen, A. W., McKown, R. C., & Ph, G. (1992) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(92)90137-v · Cited by 160
Radiographic scoring methods as outcome measures in rheumatoid arthritis: properties and advantages
Boini, S., & Guillemin, F. (2001) · Annals of the Rheumatic Diseases · doi:10.1016/s0003-4967(24)43379-7 · Cited by 160
Validation of Sleep-Tracking Technology Compared with Polysomnography in Adolescents
de Zambotti, M., Baker, F. C., & Colrain, I. M. (2015) · Sleep · doi:10.5665/sleep.4990 · Cited by 160
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.