STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 2,101–2,200 of 47,868
Relationship among Habitual Tea Consumption, Percent Body Fat, and Body Fat Distribution
Wu, C., Lu, F., Chang, C., Chang, T., Wang, R., & Chang, C. (2003) · Obesity Research · doi:10.1038/oby.2003.149 · Cited by 162
Normal pressure values and repeatability of the Emed® ST4 system
Putti, A., Arnold, G. P., Cochrane, L., & Abboud, R. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2007.06.009 · Cited by 160
Evaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
Assessing sleep using hip and wrist actigraphy
Slater, J. A., Botsis, T., Walsh, J. H., King, S., Straker, L. M., & Eastwood, P. R. (2015) · Sleep and Biological Rhythms · doi:10.1111/sbr.12103 · Cited by 194
Naidu, D., & Freer, T. J. (2013) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.04.011 · Cited by 202
Validation of FreeSurfer-Estimated Brain Cortical Thickness: Comparison with Histologic Measurements
Cardinale, F., Chinnici, G., Bramerio, M., Mai, R., Sartori, I., Cossu, M., Lo Russo, G., Castana, L., Colombo, N., Caborni, C., et al. (2014) · Neuroinformatics · doi:10.1007/s12021-014-9229-2 · Cited by 162
Klopfenstein, B. J., Kim, M. S., Krisky, C. M., Szumowski, J., Rooney, W. D., & Purnell, J. Q. (2012) · The British Journal of Radiology · doi:10.1259/bjr/57987644 · Cited by 159
Marijnissen, A. C. A., van Roermund, P. M., Melkebeek, J. V., Schenk, W., Verbout, A. J., Bijlsma, J. W. J., & Lafeber, F. P. J. G. (2002) · Arthritis & Rheumatism · doi:10.1002/art.10612 · Cited by 164
Hekler, E. B., Buman, M. P., Haskell, W. L., Conway, T. L., Cain, K. L., Sallis, J. F., Saelens, B. E., Frank, L. D., Kerr, J., & King, A. C. (2012) · Journal of Physical Activity and Health · doi:10.1123/jpah.9.2.225 · Cited by 158
Brack, T., Thüer, I., Clarenbach, C. F., Senn, O., Noll, G., Russi, E. W., & Bloch, K. E. (2007) · Chest · doi:10.1378/chest.07-0121 · Cited by 162
Air Displacement Plethysmography: Validation in Overweight and Obese Subjects
Ginde, S. R., Geliebter, A., Rubiano, F., Silva, A. M., Wang, J., Heshka, S., & Heymsfield, S. B. (2005) · Obesity Research · doi:10.1038/oby.2005.146 · Cited by 160
Lymphoedema Functioning, Disability and Health Questionnaire (Lymph-ICF): Reliability and Validity
Devoogdt, N., Van Kampen, M., Geraerts, I., Coremans, T., & Christiaens, M.-R. (2011) · Physical Therapy · doi:10.2522/ptj.20100087 · Cited by 158
Pruneri, G., Vingiani, A., Bagnardi, V., Rotmensz, N., De Rose, A., Palazzo, A., Colleoni, A. M., Goldhirsch, A., & Viale, G. (2016) · Annals of Oncology · doi:10.1093/annonc/mdv571 · Cited by 160
The management of septic arthritis in children: SYSTEMATIC REVIEW OF THE ENGLISH LANGUAGE LITERATURE
Kang, S.-N., Sanghera, T., Mangwani, J., Paterson, J. M. H., & Ramachandran, M. (2009) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.91b9.22530 · Cited by 161
Crossley, K. M., Macri, E. M., Cowan, S., Collins, N. J., & Roos, E. M. (2017) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-096776 · Cited by 166
The relative validity of a food record using the smartphone application MyFitnessPal
Teixeira, V., Voci, S. M., Mendes‐Netto, R. S., & da Silva, D. G. (2018) · Nutrition & Dietetics · doi:10.1111/1747-0080.12401 · Cited by 159
The µMCTQ: An Ultra-Short Version of the Munich ChronoType Questionnaire
Ghotbi, N., Pilz, L. K., Winnebeck, E. C., Vetter, C., Zerbini, G., Lenssen, D., Frighetto, G., Salamanca, M., Costa, R., Montagnese, S., et al. (2020) · Journal of Biological Rhythms · doi:10.1177/0748730419886986 · Cited by 161
Comparative validation of the IPAQ and the 7-Day PAR among women diagnosed with breast cancer
Johnson-Kozlow, M., Sallis, J. F., Gilpin, E. A., Rock, C. L., & Pierce, J. P. (2006) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-3-7 · Cited by 160
Buhre, W., Weyland, A., Kazmaier, S., Hanekop, G. G., Baryalei, M. M., Sydow, M., & Sonntag, H. (1999) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(99)90216-1 · Cited by 161
A New and Validated CT-Based Method for the Calculation of Orbital Soft Tissue Volumes
Regensburg, N. I., Kok, P. H. B., Zonneveld, F. W., Baldeschi, L., Saeed, P., Wiersinga, W. M., & Mourits, M. P. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1030 · Cited by 159
Reliability of surface electromyographic measurements
Kollmitzer, J., Ebenbichler, G. R., & Kopf, A. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00050-9 · Cited by 158
Brain Oxygen, CO2, pH, and Temperature Monitoring
Zauner, A., Bullock, R., Di, X., & Young, H. F. (1995) · Neurosurgery · doi:10.1227/00006123-199512000-00017 · Cited by 162
Shiota, T., Jones, M., Chikada, M., Fleishman, C. E., Castellucci, J. B., Cotter, B., DeMaria, A. N., von Ramm, O. T., Kisslo, J., Ryan, T., et al. (1998) · Circulation · doi:10.1161/01.cir.97.19.1897 · Cited by 159
Spilt, A., Box, F. M. A., van der Geest, R. J., Reiber, J. H. C., Kunz, P., Kamper, A. M., Blauw, G. J., & van Buchem, M. A. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10133 · Cited by 158
The translation and evaluation of an Urdu version of the Hospital Anxiety and Depression Scale
Mumford, D. B., Tareen, I. A. K., Bajwa, M. A. Z., Bhatti, M. R., & Karim, R. (1991) · Acta Psychiatrica Scandinavica · doi:10.1111/j.1600-0447.1991.tb07370.x · Cited by 159
Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans
Bracco, D., Thiébaud, D., Chioléro, R. L., Landry, M., Burckhardt, P., & Schutz, Y. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2580 · Cited by 159
Image-derived input functions for determination of MRGlu in cardiac (18)F-FDG PET scans.
van der Weerdt, A. P., Klein, L. J., Boellaard, R., Visser, C. A., Visser, F. C., & Lammertsma, A. A. (2001) · PubMed · Cited by 184
Kamm, M. A., & Lennard-Jones, J. E. (1990) · Diseases of the Colon & Rectum · doi:10.1007/bf02156270 · Cited by 165
Cerebral Venous Oxygen Saturation Studied with Bilateral Samples in the Internal Jugular Veins
Stocchetti, N., Paparella, A., Bridelli, F., Bacchi, M., Piazza, P., & Zuccoli, P. (1994) · Neurosurgery · doi:10.1097/00006123-199401000-00007 · Cited by 164
Shi, C., Goodall, M., Dumville, J., Hill, J., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · doi:10.1101/2022.02.16.22271062 · Cited by 158
Diagnostic validity of epidermal nerve fiber densities in painful sensory neuropathies
Vlčková‐Moravcová, E., Bednařík, J., Dušek, L., Toyka, K. V., & Sommer, C. (2008) · Muscle & Nerve · doi:10.1002/mus.20889 · Cited by 160
Marten, K., Auer, F., Schmidt, S., Kohl, G., Rummeny, E. J., & Engelke, C. (2006) · European Radiology · doi:10.1007/s00330-005-0036-x · Cited by 162
Inflammatory mediators in acute pancreatitis
Bhatia, M., Brady, M., Shokuhi, S., Christmas, S., Neoptolemos, J. P., & Slavin, J. (2000) · The Journal of Pathology · doi:10.1002/(sici)1096-9896(200002)190:2<117::aid-path494>3.0.co;2-k · Cited by 534
Comparison of Corneal Powers Obtained from 4 Different Devices
Shirayama, M., Wang, L., Weikert, M. P., & Koch, D. D. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.04.028 · Cited by 158
Schuster, A., Kutty, S., Padiyath, A., Parish, V., Gribben, P., Danford, D. A., Makowski, M. R., Bigalke, B., Beerbaum, P., & Nagel, E. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-58 · Cited by 158
van der Zwaan, H. B., Geleijnse, M. L., McGhie, J. S., Boersma, E. H., Helbing, W. A., Meijboom, F. J., & Roos‐Hesselink, J. W. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jer107 · Cited by 158
Chiumello, D., Marino, A., Brioni, M., Cigada, I., Menga, F., Colombo, A., Crimella, F., Algieri, I., Cressoni, M., Carlesso, E., et al. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201507-1413oc · Cited by 161
van der Heijde, D. M. F. M., Braun, J., Deodhar, A. A., Baraliakos, X., Landewé, R., Richards, H. B., Porter, B. O., & Readie, A. (2018) · Rheumatology · doi:10.1093/rheumatology/key128 · Cited by 158
Fundus-controlled perimetry (microperimetry): Application as outcome measure in clinical trials
Pfau, M., Jolly, J. K., Wu, Z., Denniss, J., Lad, E. M., Guymer, R. H., Fleckenstein, M., Holz, F. G., & Schmitz-Valckenberg, S. (2020) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100907 · Cited by 165
Conduit Artery Constriction Mediated by Low Flow
Gori, T., Dragoni, S., Lisi, M., Di Stolfo, G., Sonnati, S., Fineschi, M., & Parker, J. D. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.01.049 · Cited by 159
Sub-syndromal and syndromal symptoms in the longitudinal course of bipolar disorder
Paykel, E. S., Abbott, R., Morriss, R., Hayhurst, H., & Scott, J. (2006) · British Journal of Psychiatry · doi:10.1192/bjp.bp.105.013870 · Cited by 159
Exercise-induced bronchoconstriction depends on exercise load
CARLSEN, K.-H., ENGH, G., & MØRK, M. (2000) · Respiratory Medicine · doi:10.1053/rmed.2000.0809 · Cited by 159
Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Russell, R. R., Sherwin, R. S., Halickman, J. I., Cooper, D. A., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198034 · Cited by 158
Deregulation of cell survival in cystic and dysplastic renal development
Winyard, P. J. D., Nauta, J., Lirenman, D. S., Hardman, P., Sams, V. R., Risdon, R. A., & Woolf, A. S. (1996) · Kidney International · doi:10.1038/ki.1996.18 · Cited by 159
Assessment of coronary artery stenosis by magnetic resonance imaging.
Pennell, D. J., Bogren, H. G., Keegan, J., Firmin, D. N., & Underwood, S. R. (1996) · Heart · doi:10.1136/hrt.75.2.127 · Cited by 158
Quantitative magnetic resonance imaging of the brain in survivors of very low birth weight
Abernethy, L. J. (2002) · Archives of Disease in Childhood · doi:10.1136/adc.87.4.279 · Cited by 157
Stressing the accuracy: Wrist‐worn wearable sensor validation over different conditions
Menghini, L., Gianfranchi, E., Cellini, N., Patron, E., Tagliabue, M., & Sarlo, M. (2019) · Psychophysiology · doi:10.1111/psyp.13441 · Cited by 157
Nesterov, S. V., Han, C., Mäki, M. T., Kajander, S. A., Naum, A. S., Helenius, H. Y. M., Lisinen, I., Ukkonen, H., Pietilä, M., Joutsiniemi, E., et al. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1143-8 · Cited by 157
Scrutton, D., Baird, G., & Smeeton, N. (2001) · Developmental Medicine and Child Neurology · doi:10.1017/s0012162201001086 · Cited by 158
the "Progetto Alzheimer" Working Group, Pezzotti, P., Scalmana, S., Mastromattei, A., & Di Lallo, D. (2008) · BMC Family Practice · doi:10.1186/1471-2296-9-29 · Cited by 156
Assessments of trabecular bone density at implant sites on CT images
de Oliveira, R. C. G., Leles, C. R., Normanha, L. M., Lindh, C., & Ribeiro‐Rotta, R. F. (2008) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2007.08.007 · Cited by 157
The role of venous blood gas in the Emergency Department
Bloom, B., Gründlingh, J., Bestwick, J. P., & Harris, T. (2013) · European Journal of Emergency Medicine · doi:10.1097/mej.0b013e32836437cf · Cited by 163
Capiau, S., Stove, V. V., Lambert, W. E., & Stove, C. P. (2012) · Analytical Chemistry · doi:10.1021/ac303014b · Cited by 157
Chen, D., & Lam, A. K. C. (2007) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2006.11.008 · Cited by 157
Ngui, A. N., & Apparicio, P. (2011) · BMC Health Services Research · doi:10.1186/1472-6963-11-166 · Cited by 180
Characterization of the metabolic demands of simulated shipboard Royal Navy fire-fighting tasks
Bilzon, J., Scarpello, E. G., Smith, C. V., Ravenhill, N. A., & Rayson, M. P. (2001) · Ergonomics · doi:10.1080/00140130110046568 · Cited by 196
Garnero, P., Vergnaud, P., & Hoyle, N. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.094953 · Cited by 157
Blanke, P., Reinöhl, J., Schlensak, C., Siepe, M., Pache, G., Euringer, W., Geibel-Zehender, A., Bode, C., Langer, M., Beyersdorf, F., et al. (2012) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.111.967349 · Cited by 158
Comparison of a single‐channel EEG sleep study to polysomnography
Lucey, B. P., Mcleland, J. S., Toedebusch, C. D., Boyd, J., Morris, J. C., Landsness, E. C., Yamada, K., & Holtzman, D. M. (2016) · Journal of Sleep Research · doi:10.1111/jsr.12417 · Cited by 158
Kluge, F., Gaßner, H., Hannink, J., Pasluosta, C. F., Klucken, J., & Eskofier, B. M. (2017) · Sensors · doi:10.3390/s17071522 · Cited by 178
Vogel, M., Gutberlet, M., Dittrich, S., Hosten, N., & Lange, P. (1997) · Heart · doi:10.1136/hrt.78.2.127 · Cited by 157
Hense, H., Gneiting, B., Muscholl, M. W., Broeckel, U., Kuch, B., Doering, A., Riegger, G. A. J., & Schunkert, H. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00240-x · Cited by 177
An ultrasound-based method for determining pulse wave velocity in superficial arteries
Rabben, S. I., Stergiopulos, N., Hellevik, L. R., Smiseth, O. A., Slørdahl, S. A., Urheim, S., & Angelsen, B. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.031 · Cited by 176
Reliability of hand‐held dynamometry in spinal muscular atrophy
Merlini, L., Mazzone, E. S., Solari, A., & Morandi, L. (2002) · Muscle & Nerve · doi:10.1002/mus.10166 · Cited by 159
Grønholdt, M.-L. M., Wiebe, B. M., Laursen, H., Nielsen, T. G., Schroeder, T. V., & Sillesen, H. (1997) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/s1078-5884(97)80121-9 · Cited by 161
Treiber, K. H., Kronfeld, D. S., Hess, T. M., Boston, R., & Harris, P. A. (2005) · American Journal of Veterinary Research · doi:10.2460/ajvr.2005.66.2114 · Cited by 182
The assessment of methods of measurement
Chinn, S. (1990) · Statistics in Medicine · doi:10.1002/sim.4780090402 · Cited by 172
MANCONI, M., FERRI, R., SAGRADA, C., PUNJABI, N. M., TETTAMANZI, E., ZUCCONI, M., OLDANI, A., CASTRONOVO, V., & FERINI-STRAMBI, L. (2010) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2009.00801.x · Cited by 156
Clinician versus machine: Reliability and responsiveness of motor endpoints in Parkinson's disease
Heldman, D. A., Espay, A. J., LeWitt, P. A., & Giuffrida, J. P. (2014) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2014.02.022 · Cited by 156
Growth dynamics of untreated glioblastomas in vivo
Stensjøen, A. L., Solheim, O., Kvistad, K. A., Håberg, A. K., Salvesen, Ø., & Berntsen, E. M. (2015) · Neuro-Oncology · doi:10.1093/neuonc/nov029 · Cited by 158
Performance of a new laser fluorescence device for the detection of occlusal caries in vitro
Lussi, A., & Hellwig, E. (2006) · Journal of Dentistry · doi:10.1016/j.jdent.2005.11.002 · Cited by 159
Thiele, R. H., Bartels, K., & Gan, T. J. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000608 · Cited by 156
van der Zwaan, H. B., Helbing, W. A., McGhie, J. S., Geleijnse, M. L., Luijnenburg, S. E., Roos‐Hesselink, J. W., & Meijboom, F. J. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.12.001 · Cited by 157
Leung, C. K.-S., Cheng, A. C. K., Chong, K. K. L., Leung, K. S., Mohamed, S., Lau, C. S. L., Cheung, C. Y.-L., Chu, G. C.-H., Lai, R. Y. K., Pang, C. C. P., et al. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1315 · Cited by 156
Non-destructive leaf area estimation model for faba bean (Vicia faba L.)
Pekşen, E. (2007) · Scientia Horticulturae · doi:10.1016/j.scienta.2007.04.003 · Cited by 156
Görlinger, K., Dirkmann, D., Solomon, C., & Hanke, A. A. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aes374 · Cited by 158
Leach, M. O., Morgan, B., Tofts, P. S., Buckley, D. L., Huang, W., Horsfield, M. A., Chenevert, T. L., Collins, D. J., Jackson, A., Lomas, D. J., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2446-x · Cited by 169
Validation of Self-Report Pain Scales in Children
Tsze, D. S., von Baeyer, C. L., Bulloch, B., & Dayan, P. S. (2013) · PEDIATRICS · doi:10.1542/peds.2013-1509 · Cited by 187
Copay, A. G., Chung, A. S., Eyberg, B. A., Olmscheid, N., Chutkan, N. B., & Spangehl, M. J. (2018) · JBJS Reviews · doi:10.2106/jbjs.rvw.17.00159 · Cited by 175
Asgari Mehrabadi, M., Azimi, I., Sarhaddi, F., Axelin, A., Niela-Vilén, H., Myllyntausta, S., Stenholm, S., Dutt, N., Liljeberg, P., & Rahmani, A. M. (2020) · JMIR mHealth and uHealth · doi:10.2196/20465 · Cited by 155
Bland-Altman methods for comparing methods of measurement and response to criticisms
Mansournia, M. A., Waters, R., Nazemipour, M., Bland, M., & Altman, D. G. (2020) · Global Epidemiology · doi:10.1016/j.gloepi.2020.100045 · Cited by 208
Self-citationReliability and validity assessment of a linear position transducer.
Garnacho‐Castaño, M. V., Lopez‐Lastra, S., & Maté‐Muñoz, J. L. (2015) · PubMed · Cited by 161
Precision of Health-Related Quality-of-Life Data Compared With Other Clinical Measures
Hahn, E. A., Cella, D., Chassany, O., Fairclough, D. L., Wong, G. Y., & Hays, R. D. (2007) · Mayo Clinic Proceedings · doi:10.4065/82.10.1244 · Cited by 160
Handicap one year after a stroke: validity of a new scale.
Harwood, R. H., Gompertz, P., & Ebrahim, S. (1994) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.7.825 · Cited by 155
Maximal Isometric Strength of the Cervical Musculature in 100 Healthy Volunteers
Jordan, A., Mehlsen, J., Bülow, P. M., Østergaard, K., & Danneskiold‐Samsøe, B. (1999) · Spine · doi:10.1097/00007632-199907010-00012 · Cited by 156
Schwitter, J., DeMarco, T., Kneifel, S., von Schulthess, G. K., Jörg-Ciopor, M., Arheden, H., Rühm, S., Stumpe, K. O., Buck, A., Parmley, W. W., et al. (2000) · Circulation · doi:10.1161/01.cir.101.23.2696 · Cited by 159
Effect of Corneal Thickness on Dynamic Contour, Rebound, and Goldmann Tonometry
Martinez-de-la-Casa, J. M., Garcia-Feijoo, J., Vico, E., Fernandez-Vidal, A., Benitez del Castillo, J. M., Wasfi, M., & Garcia-Sanchez, J. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.06.016 · Cited by 161
Lee, V. S., Resnick, D. K., Bundy, J. M., Simonetti, O. P., Lee, P., & Weinreb, J. C. (2002) · Radiology · doi:10.1148/radiol.2223011156 · Cited by 156
Chakrabarti, S. H., Craig, J. P., Brahma, A. K., Malik, T. Y., & McGhee, C. N. J. (2001) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(01)01089-6 · Cited by 156
Fransen, J., Langenegger, T., Michel, B. A., & Stucki, G. (2000) · Rheumatology · doi:10.1093/rheumatology/39.3.321 · Cited by 158
Kupfahl, C., Honold, M., Meinhardt, G., Vogelsberg, H., Wagner, A., Mahrholdt, H., & Sechtem, U. (2004) · Heart · doi:10.1136/hrt.2003.022376 · Cited by 167
El Rahman, M. Y. A., Abdul-Khaliq, H., Vogel, M., Alexi-Meskishvili, V, Gutberlet, M., & Lange, P. E. (2000) · Heart · doi:10.1136/heart.84.4.416 · Cited by 159
Groppelli, A., Omboni, S., Parati, G., & Mancia, G. (1992) · Hypertension · doi:10.1161/01.hyp.20.2.227 · Cited by 157
Tang, S. T., & McCorkle, R. (2002) · Cancer Investigation · doi:10.1081/cnv-120005928 · Cited by 158
Ciulla, M. M., Paliotti, R., Esposito, A., Dìez, J., López, B., Dahlöf, B., Nicholls, M. G., Smith, R. D., Gilles, L., Magrini, F., et al. (2004) · Circulation · doi:10.1161/01.cir.0000137118.47943.5c · Cited by 157
Radiographic analysis of femoroacetabular impingement with Hip2norm—reliable and validated
Tannast, M., Mistry, S., Steppacher, S. D., Reichenbach, S., Langlotz, F., Siebenrock, K. A., & Guoyan Zheng, A. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20653 · Cited by 156
Direct Volumetric Blood Flow Measurement in Coronary Arteries by Thermodilution
Aarnoudse, W., Veer, M. V. ’., Pijls, N. H. J., Woorst, J. T., Vercauteren, S., Tonino, P. A. L., Geven, M., Rutten, M. C. M., van Hagen, E., Bruyne, B. D., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.047 · Cited by 156
Lassere, M. N., McQueen, F. M., Østergaard, M., Conaghan, P. G., Shnier, R., PETERFY, C. G., Klarlund, M., Bird, P., O’Connor, P., Stewart, N. R., et al. (2003) · PubMed · Cited by 156
Wong, W. W., Cochran, W., Klish, W. J., Smith, E., Lee, L. S., & Klein, P. (1988) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.1 · Cited by 156
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.