STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 1,901–2,000 of 47,868
Jensen, P. D., Jensen, F. T., Christensen, T., Eiskjær, H., Baandrup, U., & Nielsen, J. L. (2003) · Blood · doi:10.1182/blood-2002-09-2754 · Cited by 174
Three dimensional MRI estimates of brain and spinal cord atrophy in multiple sclerosis
Liu, C., Edwards, S., Gong, Q., Roberts, N., & Blumhardt, L. D. (1999) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.66.3.323 · Cited by 173
Rauh, M., Gröschl, M., Rascher, W., & Dörr, H. G. (2006) · Steroids · doi:10.1016/j.steroids.2006.01.015 · Cited by 170
Comparison of PAEE from Combined and Separate Heart Rate and Movement Models in Children
Corder, K., Brage, S., Wareham, N. J., & Ekelund, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000176466.78408.cc · Cited by 170
Cam impingement: defining the presence of a cam deformity by the alpha angle
Agricola, R., Waarsing, J. H., Thomas, G. E., Carr, A. J., Reijman, M., Bierma-Zeinstra, S. M. A., Glyn-Jones, S., Weinans, H., & Arden, N. K. (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.11.007 · Cited by 169
Left Ventricular Isovolumic Flow Sequence During Sinus and Paced Rhythms
Sengupta, P. P., Khandheria, B. K., Korinek, J., Jahangir, A., Yoshifuku, S., Milosevic, I., & Belohlavek, M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.075 · Cited by 170
Acute exacerbation of interstitial pneumonia following surgical lung biopsy
Kondoh, Y., Taniguchi, H., Kitaichi, M., Yokoi, T., Johkoh, T., Oishi, T., Kimura, T., Nishiyama, O., Kato, K., & du Bois, R. M. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.02.002 · Cited by 173
Quantitative imaging biomarkers: A review of statistical methods for computer algorithm comparisons
Obuchowski, N. A., Reeves, A. P., Huang, E. P., Wang, X.-F., Buckler, A. J., Kim, H. J. (., Barnhart, H. X., Jackson, E. F., Giger, M. L., Pennello, G., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537390 · Cited by 172
Redefining overweight and obesity in rheumatoid arthritis patients
Stavropoulos-Kalinoglou, A., Metsios, G. S., Koutedakis, Y., Nevill, A. M., Douglas, K. M., Jamurtas, A., van Zanten, J. J. C. S. V., Labib, M., & Kitas, G. D. (2007) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2006.060319 · Cited by 169
Piccirillo, G., Magri, D., Matera, S., Magnanti, M., Torrini, A., Pasquazzi, E., Schifano, E., Velitti, S., Marigliano, V., Quaglione, R., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl367 · Cited by 170
Reproducibility of flow and wall shear stress analysis using flow‐sensitive four‐dimensional MRI
Markl, M., Wallis, W., & Harloff, A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22519 · Cited by 170
Sintonen, H. (2017) · Figshare · doi:10.26180/5090032 · Cited by 170
Hoskin, P., Hanks, G., Aherne, G. W., Chapman, D., Littleton, P., & Filshie, J. (1989) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1989.tb05399.x · Cited by 170
Mackinnon, A. D., Jerrard-Dunne, P., Sitzer, M., Buehler, A., von Kegler, S., & Markus, H. S. (2004) · Stroke · doi:10.1161/01.str.0000136720.21095.f3 · Cited by 170
Skeletal muscle microbiopsy: a validation study of a minimally invasive technique
Hayot, M., Michaud, A., Koechlin, C., Caron, M.-A., LeBlanc, P., Préfaut, C., & Maltais, F. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00053404 · Cited by 172
White, W. B., Lund-Johansen, P., & Omvik, P. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90026-w · Cited by 169
Magnetic resonance imaging of coronary arteries: technique and preliminary results.
Pennell, D. J., Keegan, J., Firmin, D. N., Gatehouse, P. D., Underwood, S. R., & Longmore, D. B. (1993) · Heart · doi:10.1136/hrt.70.4.315 · Cited by 171
Anagnostaras, S. G. (2010) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2010.00158 · Cited by 169
Krzystolik, M. G., Strauber, S. F., Aiello, L. P., Beck, R. W., Berger, B. B., Bressler, N. M., Browning, D. J., Chambers, R. B., Danis, R. P., Davis, M. D., et al. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.10.055 · Cited by 169
Dückelmann, A. M., Bamberg, C., Michaelis, S. A. M., Lange, J., Nonnenmacher, A., Dudenhausen, J. W., & Kalache, K. D. (2010) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7521 · Cited by 167
Conti, M. A., Córdas, T. A., & Latorre, M. D. R. D. D. O. (2009) · Revista Brasileira de Saúde Materno Infantil · doi:10.1590/s1519-38292009000300012 · Cited by 169
Validation of the Leicester Cough Questionnaire in non-cystic fibrosis bronchiectasis
Murray, M. P., Turnbull, K., MacQuarrie, S., Pentland, J. L., & Hill, A. T. (2009) · European Respiratory Journal · doi:10.1183/09031936.00160508 · Cited by 169
Verbeke, F., Segers, P., Heireman, S., Vanholder, R., Verdonck, P., & Van Bortel, L. M. (2005) · Hypertension · doi:10.1161/01.hyp.0000166723.07809.7e · Cited by 169
Pickering, J. W., & Endre, Z. H. (2010) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.08531109 · Cited by 167
Clinical Validation of a Smartphone-Based Adapter for Optic Disc Imaging in Kenya
Bastawrous, A., Giardini, M. E., Bolster, N. M., Peto, T., Shah, N., Livingstone, I. A. T., Weiss, H. A., Hu, S., Rono, H., Kuper, H., et al. (2016) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.4625 · Cited by 169
Weight-bearing cone beam CT scans in the foot and ankle
Lintz, F., Netto, C. D. C., Barg, A., Burssens, A., Richter, M., & Weight Bearing CT International Study Group (2018) · EFORT Open Reviews · doi:10.1302/2058-5241.3.170066 · Cited by 169
The Female Sexual Function Index (FSFI)—A Systematic Review of Measurement Properties
Neijenhuijs, K. I., Hooghiemstra, N., Holtmaat, K., Aaronson, N. K., Groenvold, M., Holzner, B., Terwee, C. B., Cuijpers, P., & Verdonck-de Leeuw, I. M. (2019) · The Journal of Sexual Medicine · doi:10.1016/j.jsxm.2019.03.001 · Cited by 166
Petrovic, V. L., Jankovic, M. M., Lupsic, A. V., Mihajlovic, V. R., & Popovic-Bozovic, J. S. (2019) · IEEE Access · doi:10.1109/access.2019.2921240 · Cited by 165
Arnold, J. E., Camus, M. S., Freeman, K. P., Giori, L., Hooijberg, E. H., Jeffery, U., Korchia, J., Meindel, M. J., Moore, A. R., Sisson, S. C., et al. (2019) · Veterinary Clinical Pathology · doi:10.1111/vcp.12810 · Cited by 158
De Geyter, C., Schmitter, M., De Geyter, M., Nieschlag, E., Holzgreve, W., & Schneider, H. P. G. (2000) · Fertility and Sterility · doi:10.1016/s0015-0282(99)00484-7 · Cited by 170
Briellmann, R. S., Berkovic, S. F., Syngeniotis, A., King, M. A., & Jackson, G. D. (2002) · Annals of Neurology · doi:10.1002/ana.10171 · Cited by 168
Reproducibility of Ultrasound Assessment of Carotid Plaque Occurrence, Thickness, and Morphology
Joakimsen, O., Bønaa, K. H., & Stensland-Bugge, E. (1997) · Stroke · doi:10.1161/01.str.28.11.2201 · Cited by 169
Rezaiguia, S., Garat, C., Delclaux, C., Meignan, M., Fleury, J., Legrand, P., Matthay, M. A., & Jayr, C. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119161 · Cited by 171
Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness
Slama, M., Masson, H., Teboul, J.-L., Arnout, M.-L., Susic, D., Frohlich, E., & Andrejak, M. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00308.2002 · Cited by 172
Fluid Status, Blood Pressure, and Cardiovascular Abnormalities in Patients on Peritoneal Dialysis
Konings, C. J. A. M., Kooman, J. P., Schonck, M., Dammers, R., Cheriex, E., Meulemans, A. P. P., Hoeks, A. P. G., Van Kreel, B., Gladziwa, U., van der Sande, F. M., et al. (2002) · Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis · doi:10.1177/089686080202200406 · Cited by 168
Assessment of endothelial function using peripheral waveform analysis
Hayward, C. S., Kraidly, M., Webb, C. M., & Collins, P. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01991-5 · Cited by 170
Development of a direct weighting procedure for quality of life domains
Browne, J. P., O'Boyle, C. A., McGee, H. M., McDonald, N. J., & Joyce, C. R. B. (1997) · Quality of Life Research · doi:10.1023/a:1018423124390 · Cited by 169
Liu, R. S. N., Lemieux, L., Bell, G. S., Sisodiya, S. M., Shorvon, S. D., Sander, J. W. A. S., & Duncan, J. S. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00219-2 · Cited by 168
Van Der Kooy, K., Leenen, R., Seidell, J. C., Deurenberg, P., & Visser, M. (1993) · British Journal of Nutrition · doi:10.1079/bjn19930104 · Cited by 171
Epicardial adipose tissue is an independent predictor of coronary atherosclerotic burden
Bettencourt, N., Toschke, A. M., Leite, D., Rocha, J., Carvalho, M., Sampaio, F., Xará, S., Leite-Moreira, A., Nagel, E., & Gama, V. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2010.12.085 · Cited by 169
Measuring participation in children with disabilities using the Assessment of Life Habits
Noreau, L., Lepage, C., Boissiere, L., Picard, R., Fougeyrollas, P., Mathieu, J., Desmarais, G., & Nadeau, L. (2007) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2007.00666.x · Cited by 167
Ghio, S., Temporelli, P. L., Klersy, C., Simioniuc, A., Girardi, B., Scelsi, L., Rossi, A., Cicoira, M., Genta, F. T., & Dini, F. L. (2013) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfs208 · Cited by 171
Validity of self-reported height and weight in a Japanese workplace population
Wada, K., Tamakoshi, K., Tsunekawa, T., Otsuka, R., Zhang, H., Murata, C., Nagasawa, N., Matsushita, K., Sugiura, K., Yatsuya, H., et al. (2005) · International Journal of Obesity · doi:10.1038/sj.ijo.0803012 · Cited by 169
Yamashita, T., Yamashita, T., Shirasawa, M., Arimura, N., Terasaki, H., & Sakamoto, T. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8836 · Cited by 168
Barber, L., Barrett, R., & Lichtwark, G. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.03.005 · Cited by 169
Quantitative Fundus Autofluorescence in Healthy Eyes
Greenberg, J. P., Duncker, T., Woods, R. L., Smith, R. T., Sparrow, J. R., & Delori, F. C. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-12445 · Cited by 167
Klein, M. S., Almstetter, M. F., Schlamberger, G., Nürnberger, N., Dettmer, K., Oefner, P. J., Meyer, H. H. D., Wiedemann, S., & Gronwald, W. (2010) · Journal of Dairy Science · doi:10.3168/jds.2009-2563 · Cited by 192
Noncontact Respiration Rate Measurement System Using an Ultrasonic Proximity Sensor
Min, S. D., Kim, J. K., Shin, H. S., Yun, Y. H., Lee, C. K., & Lee, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2044239 · Cited by 168
Clinimetric and Psychometric Strategies for Development of a Health Measurement Scale
Marx, R. G., Bombardier, C., Hogg-Johnson, S., & Wright, J. G. (1999) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(98)00148-6 · Cited by 168
Regional Ventilation by Electrical Impedance Tomography
Hinz, J. M., Neumann, P., Dudykevych, T., Andersson, L. G., Wrigge, H., Burchardi, H., & Hedenstierna, G. (2003) · CHEST Journal · doi:10.1378/chest.124.1.314 · Cited by 168
Papadaki, A., Johnson, L., Toumpakari, Z., England, C., Rai, M., Toms, S., Penfold, C., Zazpe, I., Martínez-González, M., & Feder, G. (2018) · Nutrients · doi:10.3390/nu10020138 · Cited by 164
Implementing a General Framework for Assessing Interrater Agreement in Stata
Klein, D. (2018) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x1801800408 · Cited by 158
Metabolically active components of fat free mass and resting energy expenditure in nonobese adults
Illner, K., Brinkmann, G., Heller, M., Bosy-Westphal, A., & Müller, M. J. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.2.e308 · Cited by 169
van Mieghem, C. A. G., Cademartiri, F., Mollet, N. R., Malagutti, P., Valgimigli, M., Meijboom, W. B., Pugliese, F., McFadden, E. P., Ligthart, J. M. R., Runza, G., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.608950 · Cited by 168
Comparative assessment of pelvic floor strength using a perineometer and digital examination
Isherwood, P. J., & Rane, A. (2000) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2000.tb10404.x · Cited by 171
Jurvelin, J. S., Räsänen, T., Kolmonen, P., & Lyyra‐Laitinen, T. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00060-h · Cited by 168
Miglior, S., Albe, E., Guareschi, M., Mandelli, G., Gomarasca, S., & Orzalesi, N. (2004) · British Journal of Ophthalmology · doi:10.1136/bjo.2003.023416 · Cited by 191
The Diurnal Blood Pressure Profile: A Population Study
Staessen, J., Bulpitt, C. J., O'Brien, E., Cox, J., Fagard, R., Stanton, A., Thijs, L., Hulle, S. V., Vyncke, G., & Amery, A. (1992) · American Journal of Hypertension · doi:10.1093/ajh/5.6.386 · Cited by 168
La Gerche, A., MacIsaac, A. I., Burns, A. T., Mooney, D. J., Inder, W. J., Voigt, J.-U., Heidbüchel, H., & Prior, D. L. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00457.2010 · Cited by 168
Anderson, L. J., Erceg, D. N., & Schroeder, E. T. (2012) · Nutrition Research · doi:10.1016/j.nutres.2012.05.009 · Cited by 167
Yang, Z., Berr, S. S., Gilson, W. D., Toufektsian, M.-C., & French, B. A. (2004) · Circulation · doi:10.1161/01.cir.0000118495.88442.32 · Cited by 169
Feuchtner, G. M., Dichtl, W., Friedrich, G. J., Frick, M., Alber, H., Schachner, T., Bonatti, J., Mallouhi, A., Frede, T., Pachinger, O., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.056 · Cited by 169
Comparison of electrical and magnetic stimulations to assess quadriceps muscle function
Verges, S., Maffiuletti, N. A., Kerherve, H., Decorte, N., Wuyam, B., & Millet, G. Y. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01051.2007 · Cited by 168
Varpula, M., Karlsson, S., Ruokonen, E., & Pettilä, V. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0270-y · Cited by 168
Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22199 · Cited by 166
Wohlfahrt-Veje, C., Tinggaard, J., Winther, K., Mouritsen, A., Hagen, C. P., Mieritz, M. G., de Renzy-Martin, K. T., Boas, M., Petersen, J. H., & Main, K. M. (2014) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2013.282 · Cited by 166
Catley, M. J., Tabor, A., Wand, B. M., & Moseley, G. L. (2013) · Rheumatology · doi:10.1093/rheumatology/ket140 · Cited by 167
Hébuterne, X., Lémann, M., Bouhnik, Y., Dewit, O., Dupas, J.-L., Mross, M., D'Haens, G., Mitchev, K., Ernault, É., Vermeire, S., et al. (2013) · Gut · doi:10.1136/gutjnl-2012-302262 · Cited by 169
Development and validation of skinfold-thickness prediction equations with a 4-compartment model
Peterson, M. J., Czerwinski, S. A., & Siervogel, R. M. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.5.1186 · Cited by 169
Harms, H. J., Knaapen, P., de Haan, S., Halbmeijer, R., Lammertsma, A. A., & Lubberink, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1730-3 · Cited by 167
Montenij, L. J., Buhre, W. F., Jansen, J. R., Kruitwagen, C. L., & de Waal, E. E. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew094 · Cited by 165
Methodological considerations and future insights for 24-hour dietary recall assessment in children
Foster, E., & Bradley, J. (2018) · Nutrition Research · doi:10.1016/j.nutres.2017.11.001 · Cited by 167
Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT
Maret, D., Telmon, N., Peters, O. A., Lepage, B., Treil, J., Inglese, J. M., Peyre, A., Kahn, J. L., & Sixou, M. (2012) · Dentomaxillofacial Radiology · doi:10.1259/dmf/81804525 · Cited by 165
Magera, M. J., Lacey, J. M., Casetta, B., & Rinaldo, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1517 · Cited by 168
Meta-Analysis of Normative Cervical Motion
Chen, J., Solinger, A. B., Poncet, J. F., & Lantz, C. A. (1999) · Spine · doi:10.1097/00007632-199908010-00011 · Cited by 168
A Comparison of Indirect Blood Pressure Monitoring Techniques in the Anesthetized Cat
CAULKETT, N. A., CANTWELL, S. L., & HOUSTON, D. M. (1998) · Veterinary Surgery · doi:10.1111/j.1532-950x.1998.tb00143.x · Cited by 165
Gunnell, D. (2000) · International Journal of Epidemiology · doi:10.1093/ije/29.3.456 · Cited by 167
The cellular composition of induced sputum in chronic obstructive pulmonary disease
Peleman, R. A., Rytilä, P. H., Kips, J. C., Joos, G. F., & Pauwels, R. A. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.13d24.x · Cited by 170
Generating ActiGraph counts from raw acceleration recorded by an alternative monitor.
BRØND, J. C., ANDERSEN, L. B., & ARVIDSSON, D. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001344 · Cited by 166
Potential errors in pulse oximetry: I. Pulse oximeter evaluation*
RALSTON, A. C., WEBB, R. K., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09410.x · Cited by 166
The Reliability of One vs. Three Grip Trials in Symptomatic and Asymptomatic Subjects
Coldham, F., Lewis, J., & Lee, H. (2006) · Journal of Hand Therapy · doi:10.1197/j.jht.2006.04.002 · Cited by 169
Evidence-Based Guidelines for Prevention of Perioperative Hypothermia
Forbes, S. S., Eskicioglu, C., Nathens, A. B., Fenech, D. S., Laflamme, C., McLean, R. F., & McLeod, R. S. (2009) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2009.07.002 · Cited by 170
Berman, D. S., Kang, X., Gransar, H., Gerlach, J., Friedman, J. D., Hayes, S. W., Thomson, L., Hachamovitch, R., Shaw, L. J., Slomka, P. J., et al. (2009) · Journal of Nuclear Cardiology · doi:10.1007/s12350-008-9018-0 · Cited by 166
Harrigan, C. J., Peters, D. C., Gibson, C. M., Maron, B. J., Manning, W. J., Maron, M. S., & Appelbaum, E. (2011) · Radiology · doi:10.1148/radiol.10090526 · Cited by 169
Abernethy, L. J., Cooke, R. W. I., & Foulder-Hughes, L. (2004) · Pediatric Research · doi:10.1203/01.pdr.0000117843.21534.49 · Cited by 166
Binns, S. H., Sisson, D. D., Buoscio, D. A., & Schaeffer, D. J. (1995) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.1995.tb03301.x · Cited by 167
Lim, L. I. I. K., van Wegen, E. E. H., de Goede, C. J. T., Jones, D., Rochester, L., Hetherington, V., Nieuwboer, A., Willems, A. M., & Kwakkel, G. (2005) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2004.06.003 · Cited by 166
Clinical evaluation of aortic coarctation with 4D flow MR imaging
Hope, M. D., Meadows, A. K., Hope, T. A., Ordovas, K. G., Saloner, D., Reddy, G. P., Alley, M. T., & Higgins, C. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22083 · Cited by 166
Engblom, H., Xue, H., Akil, S., Carlsson, M., Hindorf, C., Oddstig, J., Hedeer, F., Hansen, M. S., Aletras, A. H., Kellman, P., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0388-9 · Cited by 165
Stefanadis, C., Stratos, C., Vlachopoulos, C., Marakas, S., Boudoulas, H., Kallikazaros, I., Tsiamis, E., Toutouzas, K., Sioros, L., & Toutouzas, P. (1995) · Circulation · doi:10.1161/01.cir.92.8.2210 · Cited by 166
Reference values for cystatin C serum concentrations in children
Bökenkamp, A., Domanetzki, M., Zinck, R., Schumann, G., & Brodehl, J. (1998) · Pediatric Nephrology · doi:10.1007/s004670050419 · Cited by 166
Amygdala pathology in psychosis of epilepsy
Tebartz van Elst, L., Baeumer, D., Lemieux, L., Woermann, F. G., Koepp, M., Krishnamoorthy, S., Thompson, P. J., Ebert, D., & Trimble, M. R. (2002) · Brain · doi:10.1093/brain/awf008 · Cited by 163
Left Ventricular Mass: Reliability of M-Mode and 2-Dimensional Echocardiographic Formulas
Myerson, S. G., Montgomery, H. E., World, M. J., & Pennell, D. J. (2002) · Hypertension · doi:10.1161/01.hyp.0000036401.99908.db · Cited by 167
Wong, S.-N., Tz Sung, R. Y., & Leung, L. C.-K. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000209082.09623.b4 · Cited by 166
Statistics in orthopaedic papers
Petrie, A. (2006) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.88b9.17896 · Cited by 167
Roman, A. J., Schwartz, S. B., Aleman, T. S., Cideciyan, A. V., Chico, J. D., Windsor, E. A. M., Gardner, L. M., Ying, G.-S., Smilko, E. E., Maguire, M. G., et al. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2004.09.008 · Cited by 164
Koopman, L. P., Slorach, C., Hui, W., Manlhiot, C., McCrindle, B. W., Friedberg, M. K., Jaeggi, E. T., & Mertens, L. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.06.014 · Cited by 164
Crim, C., Celli, B., Edwards, L. D., Wouters, E., Coxson, H. O., Tal-Singer, R., & Calverley, P. M. A. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.01.010 · Cited by 165
A rapid assay of endotoxin in whole blood using autologous neutrophil dependent chemiluminescence
Romaschin, A. D., Harris, D. M., Ribeiro, M. B., Paice, J., Foster, D. M., Walker, P. M., & Marshall, J. C. (1998) · Journal of Immunological Methods · doi:10.1016/s0022-1759(98)00003-9 · Cited by 163
Masci, P. G., Schuurman, R., Andrea, B., Ripoli, A., Coceani, M., Chiappino, S., Todiere, G., Srebot, V., Passino, C., Aquaro, G. D., et al. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.000438 · Cited by 164
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.