Automated 3-D registration of MR and CT images of the head
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529786 · Cited by 4,332 · cited 1×
“…of agreement of the observers over the different estimates and image pairs was κ = 0.63, which, although somewhat subjective because of the limited sample size, is commonly taken to indicate substantial agreement [as indicated by Landis and Koch (1977)] between observers when greater than 0.6.”
BackgroundInfluentialMulti-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Accurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
An Introduction to Information Theory.
Mallows, C. L., & Reza, F. M. (1964) · The American Mathematical Monthly · doi:10.2307/2311344 · Cited by 771
Review papers : Design and analysis of reliability studies
Dunn, G. (1992) · Statistical Methods in Medical Research · doi:10.1177/096228029200100202 · Cited by 325
Registration of MR and CT images for skull base surgery using point-like anatomical features
Hill, D. L. G., Hawkes, D. J., Crossman, J. E., Gleeson, M. J., Cox, T. C. S., Bracey, E. E. C. M. L., Strong, A. J., & Graves, P. (1991) · The British Journal of Radiology · doi:10.1259/0007-1285-64-767-1030 · Cited by 198
Self-citationAutomated multimodality image registration using information theory
Collignon, A. M. F. (1995) · Information Processing in Medical Imaging · Cited by 190
New approach to 3-D registration of multimodality medical images by surface matching:
Jiang, H., Robb, R. A., & Holton Tainter, K. S. (1992) · SPIE Proceedings · doi:10.1117/12.131078 · Cited by 162
Voxel similarity measures for automated image registration
Hill, D., Studholme, C., & Hawkes, D. J. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185180 · Cited by 149
Self-citation
Research works printed but not linked: 2
- Hill, 1994, Medical image registration using knowledge of adjacency of anatomical structures, Image Vision Comput., 12, 173, 10.1016/0262-8856(94)90069-8 · doi:10.1016/0262-8856(94)90069-8
- West, 1996, Comparison and evaluation of retrospective intermodality registration techniques, Proc. SPIE Medical Imaging, 2710
Cited by
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
“[41], normalized correlation (NC) [42], [43], mutual informa-”
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Self-citationHill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Self-citationNumerical Methods for Image Registration
Modersitzki, J. (2003) · doi:10.1093/acprof:oso/9780198528418.001.0001 · Cited by 923
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationA comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Self-citationMachine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Optimization of mutual information for multiresolution image registration
Unser, M., & Thevenaz, P. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.887976 · Cited by 697
The correlation ratio as a new similarity measure for multimodal image registration
Roche, A., Malandain, G., Pennec, X., & Ayache, N. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056301 · Cited by 542
Meyer, C. R., Boes, J. L., Kim, B., Bland, P. H., Zasadny, K. R., Kison, P. V., Koral, K., Frey, K. A., & Wahl, R. L. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85010-4 · Cited by 460
Preoperative and Intraoperative Diffusion Tensor Imaging-based Fiber Tracking in Glioma Surgery
Nimsky, C., Ganslandt, O., Hastreiter, P., Wang, R., Benner, T., Sorensen, A. G., & Fahlbusch, R. (2005) · Neurosurgery · doi:10.1227/01.neu.0000144842.18771.30 · Cited by 442
Medical image registration using mutual information
Maes, F., Vandermeulen, D., & Suetens, P. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817864 · Cited by 432
Klein, S., Staring, M., & Pluim, J. P. W. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909412 · Cited by 431
Rohlfing, T. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2163944 · Cited by 412
Maes, F., Vandermeulen, D., & Suetens, P. (1999) · Medical Image Analysis · doi:10.1016/s1361-8415(99)80030-9 · Cited by 397
Bammer, R., Keeling, S. L., Augustin, M., Pruessmann, K. P., Wolf, R., Stollberger, R., Hartung, H., & Fazekas, F. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1226 · Cited by 311
Digital Volume Correlation: Review of Progress and Challenges
Buljac, A., Jailin, C., Mendoza, A., Neggers, J., Taillandier-Thomas, T., Bouterf, A., Smaniotto, B., Hild, F., & Roux, S. (2018) · Experimental Mechanics · doi:10.1007/s11340-018-0390-7 · Cited by 305
Coles, J. P., Minhas, P. S., Fryer, T. D., Smielewski, P., Aigbirihio, F., Donovan, T., Downey, S. P. M. J., Williams, G., Chatfield, D., Matthews, J. C., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200209000-00002 · Cited by 296
Diffusion tensor imaging using single‐shot SENSE‐EPI
Bammer, R., Auer, M., Keeling, S. L., Augustin, M., Stables, L. A., Prokesch, R. W., Stollberger, R., Moseley, M. E., & Fazekas, F. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10184 · Cited by 279
Hyperventilation following head injury: Effect on ischemic burden and cerebral oxidative metabolism*
Coles, J. P., Fryer, T. D., Coleman, M. R., Smielewski, P., Gupta, A. K., Minhas, P. S., Aigbirhio, F., Chatfield, D. A., Williams, G. B., Boniface, S., et al. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000254066.37187.88 · Cited by 276
Incidence and Mechanisms of Cerebral Ischemia in Early Clinical Head Injury
Coles, J. P., Fryer, T. D., Smielewski, P., Chatfield, D. A., Steiner, L. A., Johnston, A. J., Downey, S. P. M. J., Williams, G. B., Aigbirhio, F., Hutchinson, P. J., et al. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000103022.98348.24 · Cited by 270
Automated electrocorticographic electrode localization on individually rendered brain surfaces
Hermes, D., Miller, K. J., Noordmans, H. J., Vansteensel, M. J., & Ramsey, N. F. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.10.005 · Cited by 262
Medical imaging at Guy's Hospital, King's College London
Hawkes, D. J., & Hill, D. L. G. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815866 · Cited by 260
Self-citationEgerton, A., Chaddock, C. A., Winton-Brown, T. T., Bloomfield, M. A. P., Bhattacharyya, S., Allen, P., McGuire, P. K., & Howes, O. D. (2013) · Biological Psychiatry · doi:10.1016/j.biopsych.2012.11.017 · Cited by 253
Nimsky, C., Ganslandt, O., Hastreiter, P., Wang, R., Benner, T., Sorensen, A. G., & Fahlbusch, R. (2005) · Radiology · doi:10.1148/radiol.2341031984 · Cited by 242
Fusar-Poli, P., Howes, O. D., Allen, P., Broome, M., Valli, I., Asselin, M.-C., Grasby, P. M., & McGuire, P. K. (2010) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2010.77 · Cited by 234
“Movement correction was conducted by denoising the nonattenuated dynamic image(39) and realigning the frames to a single frame acquired 6 minutes postinjection using a mutual information algorithm.(40) The transformation parameters were then applied to the corresponding attenuation-corrected frames and the realigned f…”
MethodIntraoperative visualization of the pyramidal tract by diffusion-tensor-imaging-based fiber tracking
Nimsky, C., Ganslandt, O., Merhof, D., Sorensen, A. G., & Fahlbusch, R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.001 · Cited by 229
“…a semiautomatic rigid registration is applied, that is, after a rough alignment by the user, the images are registered by the software using a rigid registration algorithm applying an intensity-based pyramidal approach using mutual information (Studholme et al., 1996; Thevenaz and Unser, 1996).”
Unifying maximum likelihood approaches in medical image registration
Roche, A., Malandain, G., & Ayache, N. (2000) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(2000)11:1<71::aid-ima8>3.0.co;2-5 · Cited by 223
In vivo 3D digital atlas database of the adult C57BL/6J mouse brain by magnetic resonance microscopy
Ma, Y. (2008) · Frontiers in Neuroanatomy · doi:10.3389/neuro.05.001.2008 · Cited by 218
“The in vitro reference image was fi rst registered with the in vivo image to be segmented (referred to as ‘target’ image) using linear and non-linear transformations [using both RVIEW (Studholme et al., 1996) and AIR_5.”
MethodDopaminergic Function in Cannabis Users and Its Relationship to Cannabis-Induced Psychotic Symptoms
Bloomfield, M. A. P., Morgan, C. J. A., Egerton, A., Kapur, S., Curran, H. V., & Howes, O. D. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.05.027 · Cited by 215
“injection using a mutual information algorithm (62).”
Fusar-Poli, P., Howes, O. D., Allen, P., Broome, M., Valli, I., Asselin, M.-C., Montgomery, A. J., Grasby, P. M., & McGuire, P. (2011) · Molecular Psychiatry · doi:10.1038/mp.2009.108 · Cited by 207
Ill-posed medicine—an introduction to image registration
Fischer, B., & Modersitzki, J. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/3/034008 · Cited by 185
“Among the many outstanding original publications are, e.g., [22] [23] [24] [25] [26] [27] [28] [29] [30] [31] [32] [33] [34] [35].”
Price, C. J. S., Menon, D. K., Peters, A. M., Ballinger, J. R., Barber, R. W., Balan, K. K., Lynch, A., Xuereb, J. H., Fryer, T., Guadagno, J. V., et al. (2004) · Stroke · doi:10.1161/01.str.0000130592.71028.92 · Cited by 174
Voxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery
Weese, J., Penney, G. P., Desmedt, P., Buzug, T. M., Hill, D. L. G., & Hawkes, D. J. (1997) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.681173 · Cited by 164
“Correlation [17], entropy [18], [19], and mutual information [20], [ 21 ] are typical quantities used as similarity”
BackgroundSelf-citationLCC-Demons: A robust and accurate symmetric diffeomorphic registration algorithm
Lorenzi, M., Ayache, N., Frisoni, G. B., & Pennec, X. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.114 · Cited by 162
“, 1995; Dong and Boyer, 1995), while the (normalized) mutual information (NMI) does not require any parametric assumption on the relationship between the intensities, and is based on the global joint intensity histogram (Maes et al., 1997; Studholme et al., 1996; Wells et al., 1996).”
BackgroundModel-driven brain shift compensation
Skrinjar, O. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00062-2 · Cited by 160
“The model consists of a set of discrete interconnected (Studholme et al., 1996)).”
BackgroundThe dopaminergic basis of human behaviors: A review of molecular imaging studies
Egerton, A., Mehta, M. A., Montgomery, A. J., Lappin, J. M., Howes, O. D., Reeves, S. J., Cunningham, V. J., & Grasby, P. M. (2009) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.05.005 · Cited by 159
“Frames were realigned to a single frame which had a high signal to noise ratio, using a mutual information algorithm (Studholme et al., 1996) and the transformation parameters were then applied to the corresponding attenuation corrected dynamic images.”
MethodThe effects of psychosocial stress on dopaminergic function and the acute stress response
Bloomfield, M. A., McCutcheon, R. A., Kempton, M., Freeman, T. P., & Howes, O. (2019) · eLife · doi:10.7554/elife.46797 · Cited by 112
“Frames were realigned to a single ‘reference’ frame, acquired 10 min post-injection, employing a mutual information algorithm (Studholme et al., 1996).”
MethodAdversity in childhood linked to elevated striatal dopamine function in adulthood
Egerton, A., Valmaggia, L. R., Howes, O. D., Day, F., Chaddock, C. A., Allen, P., Winton-Brown, T. T., Bloomfield, M. A. P., Bhattacharyya, S., Chilcott, J., et al. (2016) · Schizophrenia Research · doi:10.1016/j.schres.2016.06.005 · Cited by 103
Early Detection of Cerebral Glucose Uptake Changes in the 5XFAD Mouse
Macdonald, I. R., DeBay, D. R., Reid, G. A., O’Leary, T. P., Jollymore, C. T., Mawko, G., Burrell, S., Martin, E., Bowen, C. V., Brown, R. E., et al. (2014) · Current Alzheimer Research · doi:10.2174/1567205011666140505111354 · Cited by 79
“Visualization of the mouse-specific MR image and corresponding warped atlas mask overlay was carried out in Review [26] to assess the goodness of fit.”
MethodDopamine Function in Cigarette Smokers: An [18F]-DOPA PET Study
Bloomfield, M. A., Pepper, F., Egerton, A., Demjaha, A., Tomasi, G., Mouchlianitis, E., Maximen, L., Veronese, M., Turkheimer, F., Selvaraj, S., et al. (2014) · Neuropsychopharmacology · doi:10.1038/npp.2014.87 · Cited by 48
“Frames were realigned to a single ‘reference’ frame, acquired 10 min post-injection, employing a mutual information algorithm (Studholme et al, 1996).”
MethodBirkfellner, W., Stock, M., Figl, M., Gendrin, C., Hummel, J., Dong, S., Kettenbach, J., Georg, D., & Bergmann, H. (2009) · Medical Physics · doi:10.1118/1.3157111 · Cited by 44
Metadata
- Authors
- Studholme, C., Hill, D. L. G., & Hawkes, D. J.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 1996-06
- Volume
- 1
- Issue
- 2
- Pages
- 163-175
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2021835950
- Cited by
- 374
- References
- 14
- FWCI
- 22.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- Engineering and Physical Sciences Research Council (GR/H48170)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.