Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial
The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Abstract
Background Patients with type 1 diabetes who have impaired awareness of hypoglycaemia have a three to six times increased risk of severe hypoglycaemia. We aimed to assess whether continuous glucose monitoring (CGM) improves glycaemia and prevents severe hypoglycaemia compared with self-monitoring of blood glucose (SMBG) in this high-risk population. Methods We did a randomised, open-label, crossover trial (IN CONTROL) at two medical centres in the Netherlands. Eligible participants were patients diagnosed with type 1 diabetes according to American Diabetes Association criteria, aged 18-75 years, with impaired awareness of hypoglycaemia as confirmed by a Gold score of at least 4, and treated with either continuous subcutaneous insulin infusion or multiple daily insulin injections and doing at least three SMBG measurements per day. After screening, re-education about diabetes management, and a 6-week run-in phase (to obtain baseline CGM data), we randomly assigned patients (1:1) with a computer-generated allocation sequence (block size of four) to either 16 weeks of CGM followed by 12 weeks of washout and 16 weeks of SMBG, or 16 weeks of SMBG followed by 12 weeks of washout and 16 weeks of CGM (where the SMBG phase was the control). During the CGM phase, patients used a real-time CGM system consisting of a Paradigm Veo system with a MiniLink transmitter and an Enlite glucose sensor (Medtronic, CA, USA). During the SMBG phase, patients were equipped with a masked CGM device, con…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Benefits of CGM in this population include reductions in A1C, fewer severe hypoglycemia events in children and adults, increased TIR, as well as significant reductions in hospitalizations for severe hypoglycemia and DKA.156,162–168”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [162]
In the citing paper
“Numerous studies have demonstrated significant clinical benefits of CGM use in people with diabetes regardless of insulin delivery method (1-15).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [7]
In the citing paper
“People with diabetes who continue to have frequent and severe hypoglycemia and/or impaired awareness of hypoglycemia, despite educational interventions, may benefit from continuous subcutaneous insulin infusion (CSII) therapy or continuous glucose monitoring (CGM) or both (i.e. a sensor augmented pump), to reduce the risk of severe hypoglycemia (44)(45)(46)(47).”
From Hypoglycemia (2018) · cites this paper as [47]
In the citing paper
“Most randomized controlled trials (RCTs) in adults with type 1 diabetes show that rt-CGM leads to lower HbA 1c (156-159) and reduced time in the hypoglycemic range (160,161).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [161]
In the citing paper
“rt-CGM is beneficial in reducing the burden of hypoglycemia in older adults with type 1 diabetes (78) and those with IAH (44).”
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Diagnosis and Classification of diabetes mellitus
(2014) · Diapedia · doi:10.14496/dia..20 · Cited by 3,214
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Risk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Gold, A. E., Macleod, K. M., & Frier, B. M. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.697 · Cited by 810
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Cited by
Items 201–300 of 396
Management of Diabetic Wounds: Expert Panel Consensus Statement
Hsia, H. C., Eriksson, E. K., Gurtner, G. C., Veves, A., Hamdy, O., Margolis, D. J., Armstrong, D. G., Lavery, L. A., Grice, E., Schultz, G., et al. (2025) · Advances in Wound Care · doi:10.1177/21621918251366586 · Cited by 18
“13 Currently, CGM is suggested for all patients with type 1 diabetes (T1-DM) 13 – 15 and patients with T2DM on insulin, 16 – 18 whether it is long-acting insulin, multiple daily injection, or an insulin infusion pump.”
Patient self-testing in chronic disease management
O’Kane, M. (2019) · Journal of Laboratory Medicine · doi:10.1515/labmed-2019-0175 · Cited by 13
“9 mmol/L [17] Severe hypoglycaemia For patients with reduced hypoglycaemic awareness hypoglycaemic events reduced by 59–72% [18, 19] Time in target glycaemia (typically a target glucose concentration of 4–10 mmol/L) Increases of 1.”
BackgroundLega, I. C., Yale, J.-F., Chadha, A., Paty, B., Roscoe, R., Snider, M., Steier, J., Bajaj, H. S., Barnes, T., Gilbert, J., et al. (2023) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2023.08.003 · Cited by 25
Irace, C., Cutruzzolà, A., Tweden, K. S., & KAUFMAN, F. R. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1982380 · Cited by 14
Wang, Y., Zou, C., Na, H., Zeng, W., & Li, X. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/2851572 · Cited by 12
Zhang, L., Sun, X., & Tian, Q. (2024) · Acta Diabetologica · doi:10.1007/s00592-024-02241-0 · Cited by 12
“Additionally, a recent randomized trial found that the use of rtCGM significantly increased the time spent in normal blood glucose range for individuals with impaired hypoglycemia awareness and reduced the occurrence of severe hypoglycemia [22].”
Chaugule, S., Oliver, N. S., Klinkenbijl, B., International Access, D. O. L., & Graham, C. (2017) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2017.13.02.81 · Cited by 12
Mongraw‐Chaffin, M., Beavers, D. P., & McClain, D. A. (2019) · Journal of Clinical & Translational Endocrinology · doi:10.1016/j.jcte.2019.100202 · Cited by 13
“Further, these devices have been used specifically to avoid clinical hypoglycemia in patients with Type 1 Diabetes and hypoglycemia unawareness with much success [23,24].”
BackgroundVieira, I. H., Barros, L. M., Baptista, C. F., Melo, M., Rodrigues, D. M., & Paiva, I. (2022) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2022.102525 · Cited by 13
Significance of the CGM metric of time in range in children and adolescents with type 1 diabetes
Urakami, T. (2022) · Endocrine Journal · doi:10.1507/endocrj.ej22-0257 · Cited by 11
van Beers, C. A. J., Caris, M. G., DeVries, J. H., & Serné, E. H. (2018) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2017.09.005 · Cited by 11
“The primary and secondary outcomes of the trial have been reported previously.(12) In brief, time spent in normoglycemia during the CGMphasewas higher than time spent in normoglycemia during the SMBG phase (65.”
BackgroundMethodSelf-citationStrollo, F., Furia, A., Verde, P., Bellia, A., Grussu, M., Mambro, A., Petrelli, M. D., & Gentile, S. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108638 · Cited by 14
“[10] van Beers CA, DeVries JH, Kleijer SJ, et al.”
BackgroundMethodSperling, M. A., Wolfsdorf, J. I., Menon, R. K., Tamborlane, W. V., Maahs, D. M., Battelino, T., & Phillip, M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-62520-3.00021-x · Cited by 14
The impact of diabetes technology advances on quality of life: addressing the barriers to uptake
Kilvert, A., & Fox, C. (2023) · Practical Diabetes · doi:10.1002/pdi.2476 · Cited by 11
Marigliano, M., Piona, C. A., Mancioppi, V., Morotti, E., Morandi, A., & Maffeis, C. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15432 · Cited by 13
“4 RT-CGM data have enabled quantitative analysis of glycaemic metrics such as percentages of time spent below, within and above the target glucose, and within-period glucose variability, which can be used to make ongoing therapy decisions.”
BackgroundThomas, A., Shin, J., Jiang, B., McMahon, C., Kolassa, R., & Vigersky, R. A. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817721242 · Cited by 11
Artificial Pancreas System for Type 1 Diabetes—Challenges and Advancements
Kapil, S., Saini, R., WANGNOO, S. K., & Dhir, S. (2020) · Exploratory Research and Hypothesis in Medicine · doi:10.14218/erhm.2020.00028 · Cited by 16
Impaired hypoglycemia awareness in diabetes: epidemiology, mechanisms and therapeutic approaches
Klimontov, V. V. (2019) · Diabetes Mellitus · doi:10.14341/dm9597 · Cited by 13
Cutaneous adverse events related to FreeStyle Libre device
Brahimi, N., Potier, L., & Mohammedi, K. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30896-6 · Cited by 11
Levy, C. J., Galindo, R. J., Parkin, C. G., Gillis, J., & Argento, N. B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231161317 · Cited by 13
“33, 36, 37 and reduce 40-44 However, most state Medicaid programs do not provide CGM coverage for women with GDM.”
Nutrition education to type 1 diabetes patients: few changes over the time
Clerc, A. (2023) · Frontiers in Clinical Diabetes and Healthcare · doi:10.3389/fcdhc.2023.1243237 · Cited by 11
Maiorino, M. I., Petrizzo, M., Bellastella, G., & Esposito, K. (2017) · Endocrine · doi:10.1007/s12020-017-1328-z · Cited by 11
Waldenmaier, D., Freckmann, G., Pleus, S., Hermanns, N., Ehrmann, D., Heinemann, L., & Haug, C. (2021) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2020-001848 · Cited by 11
Alvarez, S. D., Fellas, A., Santos, D., Sculley, D., Wynne, K., Acharya, S., Navathe, P. D., Gironès, X., & Coda, A. (2023) · JMIR Diabetes · doi:10.2196/42389 · Cited by 11
Bilal, A., Yi, F., Whitaker, K. J., IGUDESMAN, D. A., Pratley, R. E., & Casu, A. (2024) · Diabetes Care · doi:10.2337/dc24-0201 · Cited by 10
Continuous glucose monitoring reduces pubertal hyperglycemia of type 1 diabetes
Nwosu, B. U., Yeasmin, S., Ayyoub, S., Rupendu, S., Villalobos-Ortiz, T. R., Jasmin, G., Parajuli, S., Zahedi, B., Zitek‐Morrison, E., Alonso, L. C., et al. (2020) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2020-0057 · Cited by 10
Lin, Y. K., Agni, A., Chuisano, S. A., Fetters, M. D., Funnell, M. M., Pop‐Busui, R., & DeJonckheere, M. J. (2023) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106231168859 · Cited by 11
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Ga, F., & Heinemann, L. (2018) · Yearbook of pediatric endocrinology · doi:10.1530/ey.15.10.9 · Cited by 10
Miller, E., Chuang, J. S., Roberts, G. J., Nabutovsky, Y., Virdi, N., & Wright, E. E. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01619-1 · Cited by 9
Howarth, S., Ho, T., Wimbury, J., & Casey, R. (2025) · Clinical Endocrinology · doi:10.1111/cen.15188 · Cited by 9
Davidsen, L., Cichosz, S. L., Stæhr, P., Vestergaard, P., Drewes, A. M., Knop, F. K., Jensen, M. H., & Olesen, S. S. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16356 · Cited by 9
“29 The model estimate obtained was the mean difference between CGM and SMBG, reported with a 95% confidence interval (CI).”
InfluentialDağdelen, S., Deyneli, O., Dınççağ, N., ILKOVA, H. M., SİVA, Z. O., Yetkin, İ., & Yilmaz, T. M. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.663222 · Cited by 11
Pangrace, M., Dolan, S., Grace, T., Greene, E., Long, E., McClelland, S., Moore, J., Morgan, D. E., Mullins, H., & Wescott, S. (2024) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2024.30.1-a.s1 · Cited by 9
Ataç, Ö., Heier, K., Moga, D. C., Fowlkes, J. L., Sohn, M., Kruse‐Diehr, A. J., Waters, T. M., & LACY, M. E. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-088785 · Cited by 9
“44 45 Moreover, healthcare providers in diabetes management may have some hesitancy to recommend CGM usage to patients who Open access have demonstrated self-efficacy in managing their condition with conventional methods.”
Understanding of type 1 diabetes mellitus: what we know and where we go
Cheon, C. K. (2018) · Korean Journal of Pediatrics · doi:10.3345/kjp.2018.06870 · Cited by 11
de Valk, H. W., Lablanche, S., Bosi, E., Choudhary, P., Silva, J. D., Castañeda, J., Vorrink, L., de Portu, S., & Cohen, O. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0222 · Cited by 9
“More recent studies, such as INCONTROL 16 and HypoDE, 17 have investigated the use of CGM alone to reduce biochemical hypoglycemia in high-risk populations.”
van Meijel, L. A., Tack, C. J., & de Galan, B. E. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14505 · Cited by 10
Flash glucose monitoring and glycemic control in type 1 diabetes with subcutaneous insulin infusion
Pinheiro, S. L., Bastos, M., Barros, L. M., Melo, M., & Paiva, I. (2021) · Acta Diabetologica · doi:10.1007/s00592-021-01827-2 · Cited by 9
Continuous Glucose Monitoring Adoption in the United Kingdom – An Economic and Policy Perspective
Oliver, N. S. (2017) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2017.13.02.73 · Cited by 10
The impact of technology on impaired awareness of hypoglycaemia in type 1 diabetes
Berry, S. A., Goodman, I., Heller, S. R., & Iqbal, A. (2025) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188251346260 · Cited by 8
Zhang, L., Xu, Y., Jiang, X., Wu, J., Liu, F., Fan, L., Li, X., Yin, G., & Yang, L. (2021) · Journal of Diabetes Investigation · doi:10.1111/jdi.13693 · Cited by 8
Addendum 1: Forum for Injection Technique and Therapy Expert Recommendations, India
Kalra, S., Unnikrishnan, A., KUMAR, K. M. P., Sahay, R. K., Chandalia, H. B., Saboo, B., Sundaram, A., Kesavadev, J., Shukla, R., WANGNOO, S. K., et al. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01332-x · Cited by 8
“CGM also has applications in the management of patients with frequent severe hypoglycaemia, often associated with hypoglycaemia unawareness [28].”
BackgroundBiopharmaceutics and clinical outcomes of emerging dosage forms of insulin: A systematic review
Olorunsola, E. O., Udoh, I. E., Ekott, M. B., Alozie, M., & Davies, K. G. (2022) · Diabetes Epidemiology and Management · doi:10.1016/j.deman.2022.100120 · Cited by 8
Lee, Y., Kim, M., & Kim, J. H. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2022.0032 · Cited by 9
de Wit, M., Rondags, S. M. P. A., van Tulder, M. W., Snoek, F. J., & Bosmans, J. E. (2017) · Diabetic Medicine · doi:10.1111/dme.13548 · Cited by 8
Self-citationSvensson, C. H., Fabricius, T. W., Verhulst, C. E. M., Kristensen, P. L., Tack, C. J., Heller, S. R., Amiel, S. A., McCrimmon, R. J., Evans, M. L., Holst, J. J., et al. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15649 · Cited by 8
“9 – 11 By extension, CGM has improved the ability to capture hypoglycaemia in real-time settings in the everyday lives of people with type 1 diabetes compared with finger-prick self-monitoring of blood glucose.”
Baxter, F., Baillie, N., Dover, A. R., Stimson, R. H., Gibb, F. W., & Forbes, S. (2024) · PLoS ONE · doi:10.1371/journal.pone.0297601 · Cited by 7
The pathophysiology of “happy” hypoglycemia
Loeb, T., Ozguler, A., Baer, G., & Baer, M. (2021) · International Journal of Emergency Medicine · doi:10.1186/s12245-021-00348-7 · Cited by 7
Wysham, C., & Kruger, D. F. (2021) · Journal of the Endocrine Society · doi:10.1210/jendso/bvab064 · Cited by 7
“• Treated with intensive insulin regimens (multiple daily injection [MDI] or insulin pump) [1, 2, 5] • Increased risk for hypoglycemia, impaired hypoglycemia awareness, frequent nocturnal hypoglycemia, frequent severe hypoglycemia [25-27].”
BackgroundMaiorino, M. I., Buzzetti, R., Irace, C., Laviola, L., Napoli, N., Pitocco, D., Esposito, K., & on behalf of LIVE CGM working group (2023) · Endocrine · doi:10.1007/s12020-023-03473-w · Cited by 7
Tamsett, Z., James, S., Brown, F., O'Neal, D. N., & Ekinci, E. I. (2024) · Diabetic Medicine · doi:10.1111/dme.15384 · Cited by 7
“30, 35– 42, 45 , 46 Paediatric research undertaken in the USA investigated capillary glucose monitoring frequencies and found an average of 3.1 to 3.8 measurements per day.”
InfluentialSchmidt, C., van Loon, B. J. P., Kiliç, E., Snoek, F. J., & Honig, A. (2017) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2017.05.009 · Cited by 7
Self-citationHohendorff, J., Ucieklak, D., SKUPIEN, J. K., Matejko, B., Giacomo, A. D., Malecki, M. T., & Klupa, T. (2019) · International Journal of Clinical Practice · doi:10.1111/ijcp.13411 · Cited by 8
Queirós, C. S., Alexandre, M. I., Garrido, P., Correia, T. E., & Filipe, P. (2020) · Contact Dermatitis · doi:10.1111/cod.13578 · Cited by 7
“This device is applied to the skin through an adhesive and remains in place for up to 14 days, dynamically measuring interstitial glucose levels.(3) Several cutaneous side effects have been recognized since its introduction, such as infections, hematomas, and irritant or allergic contact dermatitis (ACD).”
MethodA Position Statement of the Utilization and Support Status of Continuous Glucose Monitoring in Korea
Kim, W. J., Kim, J. H., Yoo, H. J., Son, J. W., Khang, A. R., Kwon, S. K., Kim, J. H., Kim, T. H., Ryu, O. H., Park, K. H., et al. (2021) · Journal of Korean Diabetes · doi:10.4093/jkd.2021.22.4.225 · Cited by 7
Kublin, O., & Stȩpień, M. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819900257 · Cited by 7
Accuracy and reliability of a continuous glucose monitoring system with a focus on hypoglycaemia
van Baal, L., Raess, L., Mathew, A., Lahner, H., Unger, N., & Führer, D. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.70408 · Cited by 6
Health promotion challenges for young adults living with intellectual disability and type 1 diabetes
Marks, A., Mahoney, N., Chen, Y.-W. R., Cordier, R., Buchanan, A., & Wilson, N. J. (2021) · Journal of Intellectual Disabilities · doi:10.1177/17446295211032767 · Cited by 6
“CGM systems are available for people using MDI or insulin pumps (van Beers et al., 2016) and consist of a small adhesive patch with sensors that send constant BGL reports to either a mobile device or insulin pump.”
MethodVisser, M. M., Charleer, S., Fieuws, S., Block, C. E. M. D., Hilbrands, R., Huffel, L. V., Maes, T., Vanhaverbeke, G., Dirinck, E. L., Myngheer, N., et al. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221128315 · Cited by 7
Avdic, T., Eliasson, B., Rawshani, A., Borén, J., Gerstein, H. C., Nordanstig, J., Rihawi, M., Beckman, J. A., McGuire, D. K., Ömerovic, E., et al. (2024) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2024.100852 · Cited by 6
Hypoglycemia in Type 1 Diabetes Mellitus
Şakar, K., & Çınar, N. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1004108 · Cited by 9
Takagi, S., Miura, J., Shimura, K., Hoshina, S., Tsuchida, Y., Takita, M., Mochizuki, S., Shen, Z., Asanuma, T., Takaike, H., et al. (2021) · Diabetology International · doi:10.1007/s13340-021-00538-x · Cited by 6
Insurance Coverage for Emerging Diabetes Technologies: Payers' Perspective
Nolan, T., & Frazzitta, M. A. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0262 · Cited by 6
Wu, C. C., Wu, K. C., José, A. S., & Novin, N. (2022) · JMIR Diabetes · doi:10.2196/30626 · Cited by 7
“patients with type 1 and type 2 diabetes [16-20].”
BackgroundSerné, E. H., van den Berg, I. K., Racca, C., van Raalte, D. H., Kramer, M. H. H., de Wit, M., & Snoek, F. J. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0232 · Cited by 8
“15 Nevertheless, the study population was overall highly educated, had already participated in general structured education programs, and seemed to be motivated in achieving good glycemic control, reflected by mean HbA1c of 7.3%, which might hamper generalizability.”
InfluentialSelf-citationTelliam, C., & Thivolet, C. H. (2020) · Diabetes & Metabolism · doi:10.1016/j.diabet.2020.05.010 · Cited by 6
Continuous Glucose Monitoring in Individuals With Type 2 Diabetes: A Quality Improvement Program
Kinson, L., & Inman, K. (2024) · Clinical Diabetes · doi:10.2337/cd24-0006 · Cited by 5
Alsahli, M. A., Alalwan, A. I., Aburisheh, K. H., Alarifi, F. F., Alshaya, H. M., Alkholaif, A. F., Shadid, A. M., Alsahli, S. A., Alsahly, A. A., & Alkhalifah, M. K. (2024) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_1630_23 · Cited by 7
Insulinoma Unmasked: A Continuous Glucose Monitoring-Fueled Journey
Koceva, A., & Krajnc, M. (2024) · Current Oncology · doi:10.3390/curroncol31090403 · Cited by 5
Glycemia Risk Index is Associated With Risk of Albuminuria Among Individuals With Type 1 Diabetes
Kim, J. Y., Yoo, J. H., Kim, N. H., & Kim, J. H. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241310850 · Cited by 5
Uduku, C. N., Pendolino, V., Jugnee, N., Oliver, N. S., Fothergill, R. T., & Reddy, M. (2023) · Diabetic Medicine · doi:10.1111/dme.15100 · Cited by 5
Thomas, A., Haak, T., Tombek, A., Kulzer, B., Ehrmann, D., Kordonouri, O., Kröger, J., Schubert-Olesen, O., Kolassa, R., Siegmund, T., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267768 · Cited by 5
Singh, A. K., Talwalkar, P., Ahluwalia, A. I., Modi, K. D., & Saboo, B. (2018) · PubMed · Cited by 5
Racca, C., Bouman, E. J., van Beers, C. A. J., Smits, M. M., van Raalte, D. H., & Serné, E. H. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.109964 · Cited by 5
Self-citationChen, N.-C., Shah, V. N., & McQueen, R. B. (2025) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaf544 · Cited by 4
Cellino, C. A. K., Chen, E.-L., Pawelek, J., Daly, C. J., Jacobs, D. M., & Prescott, G. M. (2026) · Journal of the American Pharmacists Association · doi:10.1016/j.japh.2025.103016 · Cited by 4
Schipper, S. B. J., Karagiannis, T., Zaccardi, F., Remmelzwaal, S., Blom, M. T., Dagan, N., Schoonmade, L. J., Langendam, M. W., Mb, J., Jensen, W., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06789-0 · Cited by 4
“Narrative analysis of the four trials on CGM or intermittently scanned CGM that could not be included in the meta-analysis showed similar effects on reduction of diabetes distress [158–161].”
How Much Accuracy of Interstitial Glucose Measurement Is Enough? Is There a Need for New Evidence?
Hermanns, N., Ehrmann, D., & Kulzer, B. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816677578 · Cited by 4
“Up to now, many evaluation studies about the efficacy of FGM and CGM systems have been published.(10-22) However, all these studies were designed as superiority trials, in which superiority of CGM or FGM was proven compared to self-monitoring of blood glucose.”
BackgroundCost-Utility of Real-Time Potassium Monitoring in United States Patients Receiving Hemodialysis
Bamforth, R. J., Ferguson, T. W., Tangri, N., Rigatto, C., Collister, D., & Komenda, P. V. J. (2024) · Kidney International Reports · doi:10.1016/j.ekir.2024.08.007 · Cited by 4
Efthymiadis, A., Bastounis, A., Liu, L. L., Bourlaki, M., Spinos, D., & Tsikopoulos, K. (2024) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-024-01492-6 · Cited by 4
“Similarly, a crossover RCT comparing four months of CGM with SMBG in patients with long-standing T1D and IAH failed to show restoration of hypoglycaemia awareness despite successful avoidance of severe and problematic hypoglycaemia[13].”
Maiorino, M. I., Martino, N. D., Angelino, S., Maio, A., Caruso, P., Petrizzo, M., Scappaticcio, L., Longo, M., Forestiere, D., Porcellini, C., et al. (2025) · Endocrine · doi:10.1007/s12020-025-04405-6 · Cited by 4
“…participants in the study ranged from 10.7 to the time spent in hypoglycemia in four studies [16, 29, 30, 34]; the time spent in the target range [7, 35 ], the difference in hypoglycemia awareness [6] and the number of hypoglycemic events [9, 31 ] in the remaining five studies. to -5.55, P <…”
InfluentialExpert Opinion Statement on Continuous Glucose Monitoring in Type 2 Diabetes in the Arab Gulf Region
Alshaikh, A., BAKHSH, A. M. K., Alsagheir, A., El-Laboudi, A. H., Al-Mohanadi, D. H., Alawadi, F., Elbadawi, H., Alzubaidi, L. M. Y., Al‐Sofiani, M. E., Farooqi, M. H., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251393740 · Cited by 4
Neue Therapieoptionen mit kontinuierlich gemessenen Glukosedaten – Empfehlungen für die Praxis
Seufert, J., Deiss, D., Gölz, S., Haak, T., Klausmann, G., Kroeger, J., Lobmann, R., Pfeiffer, A. F. H., Schnell, O., Seibold, A., et al. (2019) · Diabetologie und Stoffwechsel · doi:10.1055/a-0978-4537 · Cited by 4
“[19] van Beers CA, DeVries JH, Kleijer SJ et al.”
BackgroundAvari, P., Ramli, R., Reddy, M., Oliver, N. S., & Fothergill, R. T. (2019) · BMC Endocrine Disorders · doi:10.1186/s12902-019-0439-3 · Cited by 4
Garden, G. L., Frier, B. M., Hine, J. L., Hutchison, E. J., Mitchell, S. J., Shaw, K. M., Heller, S. R., Koehler, G., Hofmann, V., Gaffney, T. P., et al. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14471 · Cited by 5
Blissett, D. B., Attvall, S., & Hellmund, R. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01099-7 · Cited by 4
“In the absence of real-world data, this analysis assumes that similar to CGMs, [11, 12], flash monitoring with optional alarms improves glycaemic control in IAH populations and that patients with IAH, irrespective of whether they have T1DM or T2DM, are sixfold more likely to be admitted for severe hypoglycaemia compar…”
MethodResultLee, J., & Kim, J. H. (2021) · Ewha Medical Journal · doi:10.12771/emj.2021.44.3.55 · Cited by 4
Thomas, A., Haak, T., Tombek, A., Kulzer, B., Ehrmann, D., Kordonouri, O., Kroeger, J., Schubert-Olesen, O., Kolassa, R., Siegmund, T., et al. (2022) · Diabetologie und Stoffwechsel · doi:10.1055/a-1849-2137 · Cited by 4
“Unterstützend sind hierbei einstellbare Alarme, insbesondere prädiktive Warnungen, die helfen die Anzahl und Schwere von Hypoglykämien und Rebound-Hyperglykämien zu reduzieren.”
BackgroundInfluentialHermanns, N., Heinemann, L., Kulzer, B., Schäfer, A., Jacobsen, M., & Ehrmann, D. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112228 · Cited by 5
Continuous glucose monitoring in high-risk individuals
Chen, Z., Zhang, Y., Sun, L., & Guo, W. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120733 · Cited by 4
Chen, X., Kim, G. E., Kim, N. A., & Kim, K. J. (2026) · Healthcare · doi:10.3390/healthcare14081019 · Cited by 3
“…is most firmly established in individuals with T1D and insulin-treated T2D, where consistent evidence demonstrates improvements in glycemic control and hypoglycemia risk [5,27–32] (Tables S2 and S3) and is reflected in current guideline recommendations supporting early and sustained use [33].”
Health-Care Disparities in the Use of Diabetes Technologies in the UK
Barnard-Kelly, K. D., & Parkin, C. G. (2022) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_1_23 · Cited by 3
Been, R. A., Gans, R. O. B., Choudhary, P., van Beek, A. P., & van Dijk, P. R. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13237301 · Cited by 4
Amuedo, S., Fuentes, E. D., Avila, R. B., Remón-Ruiz, P., Soto-Moreno, A., & Venegas-Moreno, E. M. (2025) · Nutrients · doi:10.3390/nu17020222 · Cited by 4
IN CONTROL of type 1 diabetes, despite hypoglycaemia unawareness
Youssef, J. E. (2016) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30261-3 · Cited by 3
Soma, Y., Oka, R., Fujii, S., Ito, N., Kometani, M., Karashima, S., Takeda, Y., Yoneda, T., & Asano, A. (2018) · Nippon Ronen Igakkai Zasshi Japanese Journal of Geriatrics · doi:10.3143/geriatrics.55.268 · Cited by 3
Surgical options for glycaemic control in Type 1 diabetes
Yeung, K. T. D., Reddy, M., & Purkayastha, S. (2019) · Diabetic Medicine · doi:10.1111/dme.13885 · Cited by 3
Treatment of type 1 diabetes complicated by problematic hypoglycemia
Jacob, P., CHANDRAN, S. R., & Choudhary, P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814833-4.00032-0 · Cited by 3
Mutlu, G. Y., Eren, E., Eviz, E., Gökçe, T., Sakarya, S., & Hatun, Ş. (2022) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2022-0024 · Cited by 3
Sehgal, S., Elbalshy, M. M., Williman, J. A., Galland, B. C., Crocket, H. R., Hall, R. M., Paul, R. G., Leikis, R., de Bock, M. I., & Wheeler, B. J. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231196562 · Cited by 3
“22-24 This suggests the importance of clinically relevant outcomes such as high sensor wear time, and potentially highlights the inherent technical and instability challenges of open-source DIY-rtCGM solutions.”
Metadata
- Authors
- van Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H.
- Affiliations
- Amsterdam UMC Location University of Amsterdam (NL)
- Amsterdam UMC Location Vrije Universiteit Amsterdam (NL)
- Medisch Centrum Haaglanden (NL)
- ORCID
- Venue
- The Lancet Diabetes & Endocrinology
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 4
- Issue
- 11
- Pages
- 893-902
- ISSN
- 2213-8587 (ISSN-L)
- OpenAlex
- W2519559406
- Semantic Scholar
- c0ce6cdf2bed457df361f278a804bc87920252f4
- Cited by
- 386
- References
- 34
- Citations by year
- 2026: 18 · 2025: 24 · 2024: 46 · 2023: 38 · 2022: 39 · 2021: 53 · 2020: 40 · 2019: 52 · 2018: 39 · 2017: 32 · 2016: 4
- FWCI
- 42.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet Diabetes & Endocrinology (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Funders
- Eli Lilly and Company
- AstraZeneca
- Sanofi
- Vrije Universiteit Amsterdam
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, type 1 diabetes, impaired awareness of hypoglycaemia, severe hypoglycemia, self-monitoring of blood glucose, glycemic control, insulin pump therapy, multiple daily insulin injections, hypoglycemia prevention, real-time glucose monitoring
- MeSH terms
- Adult, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Female, Humans, Hypoglycemia, Male, Middle Aged, Blood Glucose Self-Monitoring, Cross-Over Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.