Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial
The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Abstract
Background Patients with type 1 diabetes who have impaired awareness of hypoglycaemia have a three to six times increased risk of severe hypoglycaemia. We aimed to assess whether continuous glucose monitoring (CGM) improves glycaemia and prevents severe hypoglycaemia compared with self-monitoring of blood glucose (SMBG) in this high-risk population. Methods We did a randomised, open-label, crossover trial (IN CONTROL) at two medical centres in the Netherlands. Eligible participants were patients diagnosed with type 1 diabetes according to American Diabetes Association criteria, aged 18-75 years, with impaired awareness of hypoglycaemia as confirmed by a Gold score of at least 4, and treated with either continuous subcutaneous insulin infusion or multiple daily insulin injections and doing at least three SMBG measurements per day. After screening, re-education about diabetes management, and a 6-week run-in phase (to obtain baseline CGM data), we randomly assigned patients (1:1) with a computer-generated allocation sequence (block size of four) to either 16 weeks of CGM followed by 12 weeks of washout and 16 weeks of SMBG, or 16 weeks of SMBG followed by 12 weeks of washout and 16 weeks of CGM (where the SMBG phase was the control). During the CGM phase, patients used a real-time CGM system consisting of a Paradigm Veo system with a MiniLink transmitter and an Enlite glucose sensor (Medtronic, CA, USA). During the SMBG phase, patients were equipped with a masked CGM device, con…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Benefits of CGM in this population include reductions in A1C, fewer severe hypoglycemia events in children and adults, increased TIR, as well as significant reductions in hospitalizations for severe hypoglycemia and DKA.156,162–168”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [162]
In the citing paper
“Numerous studies have demonstrated significant clinical benefits of CGM use in people with diabetes regardless of insulin delivery method (1-15).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [7]
In the citing paper
“People with diabetes who continue to have frequent and severe hypoglycemia and/or impaired awareness of hypoglycemia, despite educational interventions, may benefit from continuous subcutaneous insulin infusion (CSII) therapy or continuous glucose monitoring (CGM) or both (i.e. a sensor augmented pump), to reduce the risk of severe hypoglycemia (44)(45)(46)(47).”
From Hypoglycemia (2018) · cites this paper as [47]
In the citing paper
“Most randomized controlled trials (RCTs) in adults with type 1 diabetes show that rt-CGM leads to lower HbA 1c (156-159) and reduced time in the hypoglycemic range (160,161).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [161]
In the citing paper
“rt-CGM is beneficial in reducing the burden of hypoglycemia in older adults with type 1 diabetes (78) and those with IAH (44).”
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Diagnosis and Classification of diabetes mellitus
(2014) · Diapedia · doi:10.14496/dia..20 · Cited by 3,214
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Risk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Gold, A. E., Macleod, K. M., & Frier, B. M. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.697 · Cited by 810
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Cited by
Items 101–200 of 396
Glycemic Management in Adults With Type 1 Diabetes
McGibbon, A., Adams, L., Ingersoll, K. S., Kader, T., & Tugwell, B. D. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.012 · Cited by 63
Lin, Y. K., Groat, D., Chan, O., Hung, M., Sharma, A., Varner, M. W., Gouripeddi, R., Facelli, J. C., & Fisher, S. J. (2020) · Journal of the Endocrine Society · doi:10.1210/jendso/bvz005 · Cited by 39
“The eligibility criteria were T1D, ongoing real-time CGM use for longer than 3 months [6], and active CGM usage time ≥ 86% [2, 13].”
BackgroundClinical application guidelines for blood glucose monitoring in China (2022 edition)
Bao, Y., Zhu, D., & Chinese Diabetes Society (2022) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3581 · Cited by 42
Flatt, A. J., Peleckis, A. J., Dalton-Bakes, C., Nguyen, H.-L., Ilany, S., Matus, A., Malone, S. K., Goel, N., Jang, S., Weimer, J., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0506 · Cited by 39
Ulriksdotter, J., Svedman, C., Bruze, M., Glimsjö, J., Källberg, K. D., Sukakul, T., & Mowitz, M. (2020) · Contact Dermatitis · doi:10.1111/cod.13649 · Cited by 41
“The use of modern glucose sensors has improved glucose control in patients with type 1 diabetes.(1) However, adverse skin reactions at the site of application are reported by more than one-third of adult users.”
BackgroundBurckhardt, M., Abraham, M. B., Dart, J., Smith, G. J., Paramalingam, N., O’Dea, J. M., de Bock, M. I., Davis, E. A., & Jones, T. W. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0593 · Cited by 43
“16–19 Technological devices used in the management of T1D have the potential to restore hypoglycemia awareness in individuals with IAH by reducing hypoglycemia.”
Choudhary, P., Campbell, F., Joule, N., Kar, P., & on behalf of Diabetes, U. K. (2019) · Diabetic Medicine · doi:10.1111/dme.13933 · Cited by 38
“Two recent RCTs have also demonstrated the safety and efficacy of CGM in those with impaired awareness of hypoglycaemia [13,36] and, in this group, CGM may be an effective alternative to CSII in order to reduce the risk of severe hypoglycaemia.”
BackgroundCharleer, S., De Block, C., Nobels, F., Radermecker, R. P., Lowyck, I., Mullens, A., Scarnière, D., Spincemaille, K., Strivay, M., Weber, E., et al. (2020) · Diabetes Care · doi:10.2337/dc20-1531 · Cited by 39
Avari, P., Tang, W., Jugnee, N., Hersi, I., Al‐Balah, A., Tan, T., Frankel, A., Oliver, N. S., & Reddy, M. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0013 · Cited by 40
“…reductions in HbA1c and reduced exposure to hypoglycemia, 15,16 particularly in those with impaired awareness and in people at hypoglycemia risk 17,18 Intermittently scanned continuous glucose monitoring (isCGM, Freestyle Libre 1, Abbott) enables glucose data to be viewed when the user swipes a…”
Lucidi, P., Porcellati, F., Bolli, G. B., & Fanelli, C. G. (2018) · Current Diabetes Reports · doi:10.1007/s11892-018-1065-6 · Cited by 38
Zhu, T., Li, K., & Georgiou, P. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3303367 · Cited by 50
“The use of real-time continuous glucose monitoring (CGM) systems [8] has increased rapidly in recent years, and they have been shown to reduce severe hypoglycemia in people with T1D either using MDI therapy [9] or CSII therapy [10], [11].”
MethodLin, Y. K., Groat, D., Chan, O. T. M., Hung, M., Sharma, A. R., Varner, M. W., Gouripeddi, R., Facelli, J. C., & Fisher, S. J. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0016 · Cited by 39
Galindo, R. J., Parkin, C. G., Aleppo, G., Carlson, A. L., Kruger, D. F., Levy, C. J., Umpierrez, G. E., & McGill, J. B. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0107 · Cited by 39
Vloemans, A. F., van Beers, C. A. J., de Wit, M., Cleijne, W., Rondags, S. M. P. A., Geelhoed-Duijvestijn, P. H. L. M., Kramer, M. H. H., Serné, E. H., & Snoek, F. J. (2017) · Diabetic Medicine · doi:10.1111/dme.13429 · Cited by 42
Self-citationIdentifying the deficiencies of currently available CGM to improve uptake and benefit
Barnard‐Kelly, K. D., Martínez‐Brocca, M. A., Glatzer, T., & Oliver, N. (2024) · Diabetic Medicine · doi:10.1111/dme.15338 · Cited by 37
Continuous glucose monitoring for hypoglycaemia in children: perspectives in 2020
Worth, C., Dunne, M., Ghosh, A., Harper, S., & Banerjee, I. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13029 · Cited by 37
Garg, S. K., & Aktürk, H. K. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0142 · Cited by 37
Kim, J. Y., Jin, S.-M., Sim, K. H., Kim, B.-Y., Cho, J. H., Moon, J. S., Lim, S., Kang, E. S., Park, C.-Y., Kim, S. G., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06152-1 · Cited by 36
Ghandi, K., Pieri, B., Dornhorst, A., & Hussain, S. (2021) · Diabetes Therapy · doi:10.1007/s13300-020-00965-0 · Cited by 34
Aleppo, G., Hirsch, I. B., Parkin, C. G., McGill, J., Galindo, R., Kruger, D. F., Levy, C. J., Forlenza, G. P., Umpierrez, G. E., Grunberger, G., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0268 · Cited by 34
LACY, M. E., Lee, K. E., Ataç, Ö., Heier, K., Fowlkes, J. L., Kucharska‐Newton, A., & Moga, D. C. (2024) · Clinical Diabetes · doi:10.2337/cd23-0051 · Cited by 35
Babaya, N., Noso, S., Hiromine, Y., Taketomo, Y., Niwano, F., Yoshida, S., Yasutake, S., Kawabata, Y., & Ikegami, H. (2021) · Scientific Reports · doi:10.1038/s41598-021-83599-x · Cited by 38
Datye, K. A., Tilden, D. R., Parmar, A. M., Goethals, E. R., & Jaser, S. S. (2021) · Current Diabetes Reports · doi:10.1007/s11892-021-01389-1 · Cited by 34
Jacobsen, L. M., Sherr, J. L., Considine, E. G., Chen, A. X., Peeling, S., Hulsmans, M., Charleer, S., Urazbayeva, M., Tosur, M., ALAMARIE, S. A., et al. (2023) · Communications Medicine · doi:10.1038/s43856-023-00358-x · Cited by 42
Continuous glucose monitoring: transforming diabetes management step by step
Bergenstal, R. M. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30290-3 · Cited by 37
Santos, T. J. D., Dave, C., MacLeish, S. A., & Wood, J. (2021) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002537 · Cited by 33
Davis, T. M. E., Dwyer, P., England, M., Fegan, P. G., & Davis, W. A. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0331 · Cited by 31
“…endpoint during unmasked CGM compared with self-monitoring of blood glucose (SMBG) with capillary strip testing in combination with masked CGM. 6 In a retrospective audit of 35 people with type 1 diabetes and hypoglycemia unawareness, CGM reduced severe hypoglycemia and improved HbA 1c but…”
InfluentialClinical approaches to treat impaired awareness of hypoglycaemia
Farrell, C. M., & McCrimmon, R. J. (2021) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188211000248 · Cited by 31
Slover, R. H., Tryggestad, J. B., DiMeglio, L. A., Fox, L. A., Bode, B. W., Bailey, T. S., Brazg, R., Christiansen, M. P., Sherr, J. L., Tsalikian, E., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0109 · Cited by 31
Sepúlveda, E., Poínhos, R., Nata, G., Carvalho, D. M., Neves, J. S., Seixas, D., Choudhary, P., Vicente, S., & Amiel, S. A. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0034 · Cited by 32
Benefits and limitations of continuous glucose monitoring in type 1 diabetes
Stone, J. Y., & Bailey, T. S. (2020) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2020.1706482 · Cited by 30
“Many of these glycemic benefits have also been found to be true in select high-risk populations, including seniors over the age of 65 [23] and those with impaired hypoglycemic awareness [22,24].”
BackgroundRiddle, M. C., Gerstein, H. C., & Cefalu, W. T. (2017) · Diabetes Care · doi:10.2337/dci17-0049 · Cited by 30
Contact dermatitis caused by glucose sensors in diabetic children
Herman, A., Darrigade, A. ‐., de Montjoye, L., & Baeck, M. (2019) · Contact Dermatitis · doi:10.1111/cod.13429 · Cited by 33
Nocturnal Hypoglycemia in the Era of Continuous Glucose Monitoring
Kulzer, B., Freckmann, G., Ziegler, R., Schnell, O., Glatzer, T., & Heinemann, L. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267823 · Cited by 33
“29 Although in the HypoDE study, which had similar inclusion criteria to the INCONTROL study, the rate of NH 70 mg/dL was lower (2.8%).”
InfluentialMartin, C., Criego, A. B., Carlson, A. L., & Bergenstal, R. M. (2019) · Current Diabetes Reports · doi:10.1007/s11892-019-1177-7 · Cited by 34
Ridder, F. D., den Brinker, M., & Block, C. E. M. D. (2019) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018819871903 · Cited by 33
Psychosocial Aspects of Diabetes Technology
Polonsky, W. H. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.003 · Cited by 31
Cho, S. H., Kim, S., Lee, Y., Jin, S., Hur, K. Y., Kim, G., & Kim, J. H. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1165471 · Cited by 29
Avari, P., Moscardó, V., Jugnee, N., Oliver, N. S., & Reddy, M. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819867688 · Cited by 31
“In addition, rtCGM reduces hypoglycemic events compared to self-monitoring blood glucose (SMBG) in people with impaired hypoglycemia awareness.(18,19) Intermittently scanned continuous glucose monitoring (iscCGM) is a factory calibrated sensor which when scanned displays glucose concentrations and trend along with up…”
BackgroundConsensus and recommendations on continuous glucose monitoring
Saboo, B., Chawla, M. S., Jha, S., Bhandari, S., Kumar, P. K. M., Kesavadev, J., Munjal, Y. P., Mohan, V., Unnikrishnan, R., Katswar, V., et al. (2018) · Journal of Diabetology · doi:10.4103/jod.jod_45_18 · Cited by 30
Kruger, D. F., & Anderson, J. E. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0193 · Cited by 30
Continuous Glucose Monitoring–Derived Data Report—Simply a Better Management Tool
Battelino, T., & Bergenstal, R. M. (2020) · Diabetes Care · doi:10.2337/dci20-0032 · Cited by 28
Ehrmann, D., Heinemann, L., Freckmann, G., Waldenmaier, D., Faber-Heinemann, G., & Hermanns, N. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0332 · Cited by 27
“The findings of the HypoDE study for patient-reported outcomes are, however, comparable with other RCTs with rtCGM 6–8, 14, 15 or other continuous FIG.”
InfluentialKłak, A., Mańczak, M., Owoc, J., & Olszewski, R. (2021) · Polskie Archiwum Medycyny Wewnętrznej · doi:10.20452/pamw.16047 · Cited by 41
“Nevertheless, randomized controlled trials (RCTs) have delivered mixed results about impact of rtCGM on quality of life [4,6,14] and other patient-reported outcomes such as fear of hypoglycemia or hypoglycemia awareness [5,9,15,16].”
BackgroundUtilizing continuous glucose monitoring in primary care practice: What the numbers mean
Edelman, S. V., Cavaiola, T. S., BOEDER, S. C., & Pettus, J. (2020) · Primary care diabetes · doi:10.1016/j.pcd.2020.10.013 · Cited by 27
Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment.
(2018) · Europe PMC (PubMed Central) · Cited by 65
Ehrmann, D., Priesterroth, L., SCHMITT, A. J., Kulzer, B., & Hermanns, N. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0096 · Cited by 24
Wright, E. E., Roberts, G. J., Chuang, J. S., Nabutovsky, Y., Virdi, N., & Miller, E. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0015 · Cited by 22
Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023) · Endocrine Connections · doi:10.1530/ec-23-0085 · Cited by 22
Multi-Horizon Glucose Prediction Across Populations With Deep Domain Generalization
Zhu, T., Afentakis, I., Li, K., Armiger, R., Hill, N. E., Oliver, N. S., & Georgiou, P. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3428921 · Cited by 26
“Consequently, CGM has been endorsed as a standard element of T1D management [6], [7].”
Telemedicine in nephrology: future perspective and solutions
Sugawara, Y., Hirakawa, Y., & Nangaku, M. (2024) · Clinical Kidney Journal · doi:10.1093/ckj/sfae267 · Cited by 23
Kim, J. H. (2020) · Annals of Pediatric Endocrinology & Metabolism · doi:10.6065/apem.2040038.019 · Cited by 22
Lin, Y. K., Agni, A., Chuisano, S. A., de Zoysa, N., Fetters, M. D., Amiel, S. A., Pop‐Busui, R., & DeJonckheere, M. J. (2023) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2023-003415 · Cited by 24
Current and future therapies to treat impaired awareness of hypoglycemia
Macon, E. L., DEVORE, M. H., Lin, Y. K., MUSIC, M. B., WOOTEN, M., McMullen, C. A., Woodcox, A. M., MARKSBURY, A. R., Beckner, Z., Patel, B. V., et al. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1271814 · Cited by 23
Chaugule, S., & Graham, C. (2017) · Journal of Medical Economics · doi:10.1080/13696998.2017.1360312 · Cited by 24
Choudhary, P., de Portu, S., Arrieta, A., Castañeda, J., & Campbell, F. (2019) · Diabetic Medicine · doi:10.1111/dme.14043 · Cited by 23
Ridder, F. D., den Brinker, M., & Block, C. E. M. D. (2019) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018819865399 · Cited by 23
Exploring diazoxide and continuous glucose monitoring as treatment for Glut1 deficiency syndrome
Logel, S. N., Connor, E. L., Hsu, D., Fenske, R. J., Paloian, N. J., & Vivo, D. C. D. (2021) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.51462 · Cited by 22
Rizos, E. C., Markozannes, G., Charitakis, N., Filis, P., Stoimeni, A. E., Nørgaard, K., Ntzani, E. E., & Tsilidis, K. K. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0599 · Cited by 21
Hypoglycaemia and its management in primary care setting
Ibrahim, M., Baker, J., Cahn, A., Eckel, R. H., El Sayed, N. A., Fischl, A. H., Gaede, P., Leslie, R. D., Pieralice, S., Tuccinardi, D., et al. (2020) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3332 · Cited by 21
Integrating Continuous Glucose Monitoring Into Clinical Practices and Patients' Lives
Hirsch, I. B., & Miller, E. M. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0233 · Cited by 25
“22 These benefits include reductions in hemoglobin HbA1c, 7,9,11,17,18,23–27 fewer severe hypoglycemia events, 24,25,28 increased time within target glucose range (time in range [TIR]), 11,18,19,29 and reductions in time below range.”
Beck, S. E., Kelly, C., Price, D. A., & for the COACH Study Group (2021) · Diabetic Medicine · doi:10.1111/dme.14739 · Cited by 27
Sherrill, C. H., Lee, S., & Bradley, C. L. (2021) · Currents in Pharmacy Teaching and Learning · doi:10.1016/j.cptl.2021.11.021 · Cited by 20
Thomas, M. G., Avari, P., Godsland, I. F., Lett, A. M., Reddy, M., & Oliver, N. S. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14498 · Cited by 23
“tantly underline that the clinical impact is achievable using standalone CGM without insulin pump therapy.(16,30,42,43) Intermittently scanned CGM was not included as there are insufficient RCTs assessing it but”
BackgroundAnticoagulation protocol and early prosthetic valve thrombosis.
Talwar, S., Kapoor, C. K., Devagourou, V., & Kumar, A. S. (2004) · PubMed · Cited by 24
Maida, E., Caruso, P., Bonavita, S., Abbadessa, G., Miele, G., Longo, M., Scappaticcio, L., Ruocco, E., Trojsi, F., Esposito, K., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14124240 · Cited by 15
Hypoglycemia Unawareness in Insulinoma Revealed with Flash Glucose Monitoring Systems
Sugawa, T., Murakami, T., Yabe, D., Kashima, R., Tatsumi, M., Ooshima, S., Joo, E., Wada, K., Yoshizawa, A., Masui, T., et al. (2018) · Internal Medicine · doi:10.2169/internalmedicine.1173-18 · Cited by 19
“Fasting hypoglycemia is known to be common in insulinoma and has diagnostic value, as more than 80% of patients with insulinoma demonstrate fasting hypoglycemia (3, 4).”
BackgroundConget, I., Mangas, M. Á., Morales, C., Caro, J., Giménez, M., Borrell, M., & Delgado, E. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01153-4 · Cited by 20
Pathophysiology and management of hypoglycemia in diabetes
RANGEL, E. S., Deajon-Jackson, J. D., & Hwang, J. J. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14904 · Cited by 21
Nattero‐Chávez, L., Pascual, E. L., de la Villa, E. D. L. C., Cebada, A. B., Ruiz, T., Tobar, A. Q., Lorenzo, M., Sánchez, C., Izquierdo, A., Luque‐Ramírez, M., et al. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110627 · Cited by 19
Builes-Montaño, C. E., Lema-Pérez, L., Rincón, A. R., Tobón, J. J. Z., Restrepo-Gutiérrez, J. C., Álvarez, H., & Garcia‐Tirado, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-23165-x · Cited by 20
Hermanns, N., Ehrmann, D., Heinemann, L., Freckmann, G., Waldenmaier, D., & Calhoun, P. M. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0130 · Cited by 19
“19,20,30 More empirical evidence for the defi-nition of specific cutoff values for the assessment of future hypoglycemia in open and masked CGM (professional CGM systems) is clearly welcome.”
Urakami, T. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12030781 · Cited by 19
“It has been reported that the use of CGM [63] or the sensor-augmented insulin pump (SAP) with the control algorithms including the low glucose suspend (LGS) system [64,65] could prevent severe hypoglycemia in patients with impaired awareness of hypoglycemia.”
MethodManaging Severe Hypoglycaemia in Patients with Diabetes: Current Challenges and Emerging Therapies
Demirbilek, H., Vurallı, D., Haris, B., & Hussain, K. (2023) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s313837 · Cited by 23
Galindo, R. J., Aleppo, G., Parkin, C. G., Baidal, D. A., Carlson, A. L., Cengiz, E., Forlenza, G. P., Kruger, D. F., Levy, C. J., McGill, J. B., et al. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221144052 · Cited by 19
“17,20,30,36,38 • Significant decreases in %TBR. 17,30,36 • Significant reductions in diabetes-related hospitalizations.”
The growing use of continuous glucose monitors in people without diabetes: an evidence‐free zone
Guess, N. D. (2023) · Practical Diabetes · doi:10.1002/pdi.2475 · Cited by 20
Miller, E. M., & Miller, K. (2024) · Clinical Diabetes · doi:10.2337/cd23-0077 · Cited by 20
“Numerous studies have demonstrated the safety and ef fi - cacy of continuous glucose monitoring (CGM) in individuals with type 1 diabetes and those with diagnosed type 2 diabetes who are treated with intensive insulin therapy (4 – 17).”
BackgroundDemir, G., Özen, S., Çetin, H., Darcan, Ş., & Gökşen, D. (2019) · Journal of Clinical Research in Pediatric Endocrinology · doi:10.4274/jcrpe.galenos.2019.2019.0009 · Cited by 20
Nefs, G., Bazelmans, E., Marsman, D. E., Snellen, N., Tack, C. J., & de Galan, B. E. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.107910 · Cited by 22
Langford, A. T., Orellana, K. T., & Buderer, N. M. F. (2022) · Contemporary Clinical Trials · doi:10.1016/j.cct.2022.106676 · Cited by 17
Alfadli, S. F., Alotaibi, Y. S., Aqdi, M. J., Almozan, L. A., Alzubaidi, Z. B., Altemani, H. A., Almutairi, S. D., Alabdullah, H. A., Almehmadi, A. A., Alanzi, A. L., et al. (2025) · Metabolism Open · doi:10.1016/j.metop.2025.100382 · Cited by 16
Patient‐reported outcomes in studies of diabetes technology: What matters
Liarakos, A. L., Crabtree, T. S. J., & Wilmot, E. G. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15858 · Cited by 19
Porcellati, F., Mauro, S. D., Mazzieri, A., Scamporrino, A., Filippello, A., Fano, M. D., Fanelli, C. G., Purrello, F., Malaguarnera, R., & Piro, S. (2021) · Biomolecules · doi:10.3390/biom11091281 · Cited by 19
“The IN CONTROL study [76], enrolled a group of patients (29 in Multiple Daily Insulin Injections (MDI) and 23 in Continuous Subcutaneous Insulin Infusion (CSII)) with hypoglycemia unawareness and at high risk of severe hypoglycemic.”
BackgroundHow use of continuous glucose monitoring can address therapeutic inertia in primary care
Martens, T. W., & Parkin, C. G. (2022) · Postgraduate Medicine · doi:10.1080/00325481.2022.2080419 · Cited by 16
Role of Continuous Glucose Monitoring in Insulin-Requiring Patients with Diabetes
Welsh, J. B. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0100 · Cited by 17
Use of continuous glucose monitoring trend arrows in the younger population with type 1 diabetes
Elbarbary, N. S., Moser, O., Al-Yaarubi, S., Alsaffar, H., Shaikh, A. M. A., Ajjan, R., & Deeb, A. (2021) · Diabetes and Vascular Disease Research · doi:10.1177/14791641211062155 · Cited by 16
Herman, W. H., Braffett, B. H., Kuo, S., Lee, J. M., Brändle, M., Jacobson, A. M., Prosser, L. A., & Lachin, J. M. (2018) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2018.06.005 · Cited by 18
Holt, R. I. G., DeVries, J. H., Fischl, A. H., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, É., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05600-6 · Cited by 19
Self-citationZandona, A., Vettoretti, M., Longato, E., Li, Y., Madondo, K., Pagan, J., Siscovick, D. S., & Di Camillo, B. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.2525.abstracts · Cited by 15
van Beers, C. A. J., de Wit, M., Kleijer, S. J., Geelhoed-Duijvestijn, P. H. L. M., DeVries, J. H., Kramer, M. H. H., Diamant, M., Serné, E. H., & Snoek, F. J. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0141 · Cited by 17
“We report on the possible modifying effect of psychological distress, specifically emotional well-being, diabetes-related distress, and fear of hypoglycemia, on CGM outcomes as recently reported in a trial in patients with T1D and impaired awareness of hypoglycemia, comparing CGM versus SMBG. 4 We observed lower effect…”
InfluentialSelf-citationCharleer, S., Gillard, P., Vandoorne, E., Cammaerts, K., Mathieu, C., & Casteels, K. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13128 · Cited by 14
Hybrid Closed Loop in Adults With Type 1 Diabetes and Severely Impaired Hypoglycemia Awareness
Lee, M. H., Gooley, J. L., Obeyesekere, V. R., Lu, J., Paldus, B., Hendrieckx, C., MacIsaac, R. J., McAuley, S. A., Speight, J., Vogrin, S., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241245627 · Cited by 14
“47,48 Continuous glucose monitoring alone clearly reduces hypoglycemia, 49,50 although inconsistently restores epinephrine responses and hypoglycemia awareness in those with IAH.”
Billion, L., Charleer, S., Verbraeken, L., Sterckx, M., Vangelabbeek, K., Block, N. D., Janssen, C., Dessel, K. V., Dirinck, E. L., PEIFFER, F. W., et al. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14527 · Cited by 15
Madar, H., Wu, Z., Bandini, A., Perkins, B. A., Messier, V., Pomey, M., Brazeau, A., & RABASA-LHORET, R. P. R. (2022) · Acta Diabetologica · doi:10.1007/s00592-022-01987-9 · Cited by 16
“Factors associated with lower risk included: use of insulin pump [24] or use of continuous glucose monitoring [25].”
BackgroundMustonen, J., Rautiainen, P., Lamidi, M., Lavikainen, P., Martikainen, J. A., & Laatikainen, T. K. (2023) · Acta Diabetologica · doi:10.1007/s00592-023-02079-y · Cited by 15
Kropff, J., van Steen, S. C. J., deGraaff, P., Chan, M. W., van Amstel, R. B. E., & DeVries, J. H. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0189 · Cited by 15
Self-citationUrakami, T., Terada, H., Yoshida, K., Kuwabara, R., Mine, Y., Aoki, M., Shoji, Y., Suzuki, J., & Morioka, I. (2022) · Journal of Diabetes Investigation · doi:10.1111/jdi.13830 · Cited by 16
CASTORINO, K. N., Durnwald, C. P., Ehrenberg, S., Ehrhardt, N. M., Isaacs, D., Levy, C. J., Valent, A. M., & Continuous Glucose Monitoring for Gestational Diabetes Management Working Group (2024) · Journal of Women s Health · doi:10.1089/jwh.2023.0864 · Cited by 15
“42, 45 , 46 and reduces A recent report highlighted Black (32.0”
InfluentialKim, J. Y., Kim, S., & Kim, J. H. (2025) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2024.0804 · Cited by 13
Folz, H. N., Lee, S., & Sherrill, C. H. (2024) · Patient Education and Counseling · doi:10.1016/j.pec.2024.108578 · Cited by 13
Metadata
- Authors
- van Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H.
- Affiliations
- Amsterdam UMC Location University of Amsterdam (NL)
- Amsterdam UMC Location Vrije Universiteit Amsterdam (NL)
- Medisch Centrum Haaglanden (NL)
- ORCID
- Venue
- The Lancet Diabetes & Endocrinology
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 4
- Issue
- 11
- Pages
- 893-902
- ISSN
- 2213-8587 (ISSN-L)
- OpenAlex
- W2519559406
- Semantic Scholar
- c0ce6cdf2bed457df361f278a804bc87920252f4
- Cited by
- 386
- References
- 34
- Citations by year
- 2026: 18 · 2025: 24 · 2024: 46 · 2023: 38 · 2022: 39 · 2021: 53 · 2020: 40 · 2019: 52 · 2018: 39 · 2017: 32 · 2016: 4
- FWCI
- 42.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet Diabetes & Endocrinology (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Funders
- Eli Lilly and Company
- AstraZeneca
- Sanofi
- Vrije Universiteit Amsterdam
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, type 1 diabetes, impaired awareness of hypoglycaemia, severe hypoglycemia, self-monitoring of blood glucose, glycemic control, insulin pump therapy, multiple daily insulin injections, hypoglycemia prevention, real-time glucose monitoring
- MeSH terms
- Adult, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Female, Humans, Hypoglycemia, Male, Middle Aged, Blood Glucose Self-Monitoring, Cross-Over Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.