Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial
The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Abstract
Background Patients with type 1 diabetes who have impaired awareness of hypoglycaemia have a three to six times increased risk of severe hypoglycaemia. We aimed to assess whether continuous glucose monitoring (CGM) improves glycaemia and prevents severe hypoglycaemia compared with self-monitoring of blood glucose (SMBG) in this high-risk population. Methods We did a randomised, open-label, crossover trial (IN CONTROL) at two medical centres in the Netherlands. Eligible participants were patients diagnosed with type 1 diabetes according to American Diabetes Association criteria, aged 18-75 years, with impaired awareness of hypoglycaemia as confirmed by a Gold score of at least 4, and treated with either continuous subcutaneous insulin infusion or multiple daily insulin injections and doing at least three SMBG measurements per day. After screening, re-education about diabetes management, and a 6-week run-in phase (to obtain baseline CGM data), we randomly assigned patients (1:1) with a computer-generated allocation sequence (block size of four) to either 16 weeks of CGM followed by 12 weeks of washout and 16 weeks of SMBG, or 16 weeks of SMBG followed by 12 weeks of washout and 16 weeks of CGM (where the SMBG phase was the control). During the CGM phase, patients used a real-time CGM system consisting of a Paradigm Veo system with a MiniLink transmitter and an Enlite glucose sensor (Medtronic, CA, USA). During the SMBG phase, patients were equipped with a masked CGM device, con…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Benefits of CGM in this population include reductions in A1C, fewer severe hypoglycemia events in children and adults, increased TIR, as well as significant reductions in hospitalizations for severe hypoglycemia and DKA.156,162–168”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [162]
In the citing paper
“Numerous studies have demonstrated significant clinical benefits of CGM use in people with diabetes regardless of insulin delivery method (1-15).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [7]
In the citing paper
“People with diabetes who continue to have frequent and severe hypoglycemia and/or impaired awareness of hypoglycemia, despite educational interventions, may benefit from continuous subcutaneous insulin infusion (CSII) therapy or continuous glucose monitoring (CGM) or both (i.e. a sensor augmented pump), to reduce the risk of severe hypoglycemia (44)(45)(46)(47).”
From Hypoglycemia (2018) · cites this paper as [47]
In the citing paper
“Most randomized controlled trials (RCTs) in adults with type 1 diabetes show that rt-CGM leads to lower HbA 1c (156-159) and reduced time in the hypoglycemic range (160,161).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [161]
In the citing paper
“rt-CGM is beneficial in reducing the burden of hypoglycemia in older adults with type 1 diabetes (78) and those with IAH (44).”
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Diagnosis and Classification of diabetes mellitus
(2014) · Diapedia · doi:10.14496/dia..20 · Cited by 3,214
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Risk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Gold, A. E., Macleod, K. M., & Frier, B. M. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.697 · Cited by 810
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Cited by
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Self-citation6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
6. Glycemic Targets: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s006 · Cited by 744
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699
“Islet and pancreas transplants are the only approaches to date that confer both sustained recovery from IAH and restoration of glucose counterregulation and, thereby, reliable protection from level 3 hypoglycemia in people with long-standing type 1 diabetes (242).”
InfluentialSelf-citation6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
Martens, T., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · JAMA · doi:10.1001/jama.2021.7444 · Cited by 543
Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05568-3 · Cited by 378
Self-citationThe relationship of hemoglobin A1C to time-in-range in patients with diabetes
Vigersky, R. A., & McMahon, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0310 · Cited by 464
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
“9 With the benefit of time and the large number of studies that have followed, we can now be much more as-sertive regarding the clinical benefits of CGM.”
InfluentialDiabetes structured self-management education programmes: a narrative review and current innovations
Chatterjee, S., Davies, M. J., Heller, S., Speight, J., Snoek, F. J., & Khunti, K. (2018) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30239-5 · Cited by 372
Self-citationMaiorino, M. I., Signoriello, S., Maio, A., Chiodini, P., Bellastella, G., Scappaticcio, L., Longo, M., Giugliano, D., & Esposito, K. (2020) · Diabetes Care · doi:10.2337/dc19-1459 · Cited by 364
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
“The primary outcome was met and showed benefit in adults of all ages (30,40,41,46,47, 49,51,52) including seniors (48).”
BackgroundSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Polonsky, W. H., Hessler, D., Ruedy, K. J., & Beck, R. W. (2017) · Diabetes Care · doi:10.2337/dc17-0133 · Cited by 346
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
An Effective Model of Diabetes Care and Education: The ADCES7 Self-Care Behaviors™
Association of Diabetes Care and Education Specialists, & Kolb, L. (2021) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721720978154 · Cited by 246
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 250
“risk for episodes of hypoglycemia (35),”
Charleer, S., De Block, C., Van Huffel, L., Broos, B., Fieuws, S., Nobels, F., Mathieu, C., & Gillard, P. (2020) · Diabetes Care · doi:10.2337/dc19-1610 · Cited by 261
A View Beyond HbA1c: Role of Continuous Glucose Monitoring
Chehregosha, H., Khamseh, M. E., Malek, M., Hosseinpanah, F., & Ismail-Beigi, F. (2019) · Diabetes Therapy · doi:10.1007/s13300-019-0619-1 · Cited by 235
Reddy, M., Jugnee, N., El Laboudi, A., Spanudakis, E., Anantharaja, S., & Oliver, N. (2018) · Diabetic Medicine · doi:10.1111/dme.13561 · Cited by 245
Šoupal, J., Petruželková, L., Grunberger, G., Hásková, A., Flekač, M., Matoulek, M., Mikeš, O., Pelcl, T., Škrha, J., Horová, E., et al. (2020) · Diabetes Care · doi:10.2337/dc19-0888 · Cited by 242
“Similar improvements in A1C and hypoglycemia have also been observed in participants using rtCGM with insulin pump therapy (12,13).”
BackgroundAdvances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
Moser, O., Riddell, M. C., Eckstein, M. L., Adolfsson, P., Rabasa-Lhoret, R., van den Boom, L., Gillard, P., Nørgaard, K., Oliver, N. S., Zaharieva, D. P., et al. (2020) · Diabetologia · doi:10.1007/s00125-020-05263-9 · Cited by 214
Abraham, M. B., Jones, T. W., Naranjo, D., Karges, B., Oduwole, A., Tauschmann, M., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12698 · Cited by 226
Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring
Edelman, S. V., Argento, N. B., Pettus, J., & Hirsch, I. B. (2018) · Diabetes Care · doi:10.2337/dc18-1150 · Cited by 199
“Findings from a recent randomized trial using a crossover study design assessed the impact of rtCGM versus SMBG use in T1D patients with impaired hypoglycemia awareness (51).”
Method7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
“In one study in patients who were at higher risk for episodes of hypoglycemia (48), therewas a reduction in rates of all levels of hypoglycemia (see Section 6 “Glycemic Targets,” https://doi.”
BackgroundISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Continuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus
Lin, R., Brown, F., James, S., Jones, J., & Ekinci, E. (2021) · Diabetic Medicine · doi:10.1111/dme.14528 · Cited by 197
Teo, E., Hassan, N., Tam, W., & Koh, S. (2022) · Diabetologia · doi:10.1007/s00125-021-05648-4 · Cited by 186
An Effective Model of Diabetes Care and Education: Revising the AADE7 Self-Care Behaviors ®
American Association of Diabetes Educators (2020) · The Diabetes Educator · doi:10.1177/0145721719894903 · Cited by 184
7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
“mia (87), there was a reduction in rates of all levels of hypoglycemia (see Section 6 “Glycemic Targets” for hypogly-”
BackgroundLawton, J., Blackburn, M., Allen, J., Campbell, F., Elleri, D., Leelarathna, L., Rankin, D., Tauschmann, M., Thabit, H., & Hovorka, R. (2018) · BMC Endocrine Disorders · doi:10.1186/s12902-018-0239-1 · Cited by 174
“been shown to reduce hypoglycaemia and hyperglycaemia [2, 3, 5], severe hypoglycaemia [6]; and, improve treatment satisfaction [7–9] and quality of life outcomes [10, 11].”
BackgroundHeinemann, L., Schoemaker, M., Schmelzeisen-Redecker, G., Hinzmann, R., Kassab, A., Freckmann, G., Reiterer, F., & Del Re, L. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819855670 · Cited by 170
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
Oskarsson, P., Antuna, R., Geelhoed-Duijvestijn, P., Krӧger, J., Weitgasser, R., & Bolinder, J. (2018) · Diabetologia · doi:10.1007/s00125-017-4527-5 · Cited by 160
“In addition, a crossover study design may add to the evidence that continuous monitoring has an effect only concurrent with treatment [10, 31], and a longer duration study may demonstrate sustained avoidance of hypoglycaemia with continued use of the device in type 1 diabetes, similar to use in type 2 diabetes [33].”
BackgroundResultSelf-citationVisser, M. M., Charleer, S., Fieuws, S., De Block, C., Hilbrands, R., Van Huffel, L., Maes, T., Vanhaverbeke, G., Dirinck, E., Myngheer, N., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00789-3 · Cited by 165
Bally, L., Thabit, H., Kojzar, H., Mader, J. K., Qerimi-Hyseni, J., Hartnell, S., Tauschmann, M., Allen, J. M., Wilinska, M. E., Pieber, T. R., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30001-3 · Cited by 150
Continuous glucose monitoring: The achievement of 100 years of innovation in diabetes technology
Galindo, R. J., & Aleppo, G. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108502 · Cited by 133
Improving the clinical value and utility of CGM systems: issues and recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetologia · doi:10.1007/s00125-017-4463-4 · Cited by 149
McCall, A. L., Lieb, D. C., Gianchandani, R., MacMaster, H., Maynard, G. A., Murad, M. H., Seaquist, E., Wolfsdorf, J. I., Wright, R. F., & Wiercioch, W. (2023) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac596 · Cited by 123
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Continuous Glucose Monitoring: A Brief Review for Primary Care Practitioners
Ajjan, R., Slattery, D., & Wright, E. (2019) · Advances in Therapy · doi:10.1007/s12325-019-0870-x · Cited by 120
Bosi, E., Choudhary, P., de Valk, H. W., Lablanche, S., Castañeda, J., de Portu, S., Da Silva, J., Ré, R., Vorrink-de Groot, L., Shin, J., et al. (2019) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(19)30150-0 · Cited by 125
Malahi, A. E., Elsen, M. V., Charleer, S., Dirinck, E. L., Ledeganck, K. J., Keymeulen, B., Crenier, L., Radermecker, R. P., Taes, Y., Vercammen, C., et al. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab688 · Cited by 131
Ólafsdóttir, A. F., Polonsky, W., Bolinder, J., Hirsch, I. B., Dahlqvist, S., Wedel, H., Nyström, T., Wijkman, M., Schwarcz, E., Hellman, J., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0363 · Cited by 113
“We recently showed that to obtain an effect of CGM on HbA1c in persons with type 1 diabetes and treated with MDI, continuous use is needed,(7) which has also been shown for insulin pump users.(12,14) In the present study, we found that continuous use of monitoring is needed to obtain beneficial effects on reducing hyp…”
BackgroundMethodSherr, J. L., Laffel, L. M., Liu, J., Wolf, W., Bispham, J., Chapman, K. S., Finan, D., Titievsky, L., Liu, T., Hagan, K., et al. (2024) · Diabetes Care · doi:10.2337/dc23-1765 · Cited by 99
Abraham, M. B., Karges, B., Dovč, K., Naranjo, D. M., Arbeláez, A. M., Mbogo, J., Javelikar, G., Jones, T. W., & Mahmud, F. H. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13443 · Cited by 143
New advances in type 1 diabetes
Subramanian, S., Khan, F., & Hirsch, I. B. (2024) · BMJ · doi:10.1136/bmj-2023-075681 · Cited by 88
Johnson, M. L., Martens, T. W., Criego, A. B., Carlson, A. L., Simonson, G. D., & Bergenstal, R. M. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0034 · Cited by 104
Dicembrini, I., Cosentino, C., Monami, M., Mannucci, E., & Pala, L. (2021) · Acta Diabetologica · doi:10.1007/s00592-020-01589-3 · Cited by 106
Yale, J.-F., Paty, B., & Senior, P. A. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.010 · Cited by 105
Elbalshy, M., Haszard, J., Smith, H., Kuroko, S., Galland, B., Oliver, N., Shah, V., de Bock, M. I., & Wheeler, B. J. (2022) · Diabetic Medicine · doi:10.1111/dme.14854 · Cited by 104
Moser, O., Riddell, M. C., Eckstein, M. L., Adolfsson, P., Rabasa‐Lhoret, R., Boom, L., Gillard, P., Nørgaard, K., Oliver, N. S., Zaharieva, D. P., et al. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13105 · Cited by 91
Reddy, M., Jugnee, N., Anantharaja, S., & Oliver, N. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0252 · Cited by 91
Evolution of Diabetes Technology
Dovč, K., & Battelino, T. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.009 · Cited by 132
Speight, J., Choudhary, P., Wilmot, E. G., Hendrieckx, C., Forde, H., Cheung, W. Y., Crabtree, T., Millar, B., Traviss‐Turner, G., Hill, A., et al. (2023) · Diabetic Medicine · doi:10.1111/dme.14944 · Cited by 92
Pease, A., Lo, C., Earnest, A., Kiriakova, V., Liew, D., & Zoungas, S. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0417 · Cited by 83
Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes
Slattery, D., & Choudhary, P. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0051 · Cited by 87
Little, S. A., Speight, J., Leelarathna, L., Walkinshaw, E., Tan, H. K., Bowes, A., Lubina-Solomon, A., Chadwick, T. J., Stocken, D. D., Brennand, C., et al. (2018) · Diabetes Care · doi:10.2337/dc17-2682 · Cited by 86
Advances in Continuous Glucose Monitoring: Clinical Applications
Kwon, S. Y., & Moon, J. S. (2025) · Endocrinology and Metabolism · doi:10.3803/enm.2025.2370 · Cited by 94
“Van Beers et al. [12] reported a 59% reduction in severe hypoglycemia, defined as an event requiring third-party assistance, in CGM users compared to the SMBG group.”
Lin, Y. K., Fisher, S. J., & Pop‐Busui, R. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13290 · Cited by 82
Moon, J. S., Kang, S., Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Seo, J. A., Kim, M. K., et al. (2024) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2024.0249 · Cited by 90
Current Eligibility Requirements for CGM Coverage Are Harmful, Costly, and Unjustified
Anderson, J. E., Gavin, J. R., & Kruger, D. F. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0303 · Cited by 77
“Importantly, CGM use has been shown to be particularly effective among those with frequent severe hypoglycemia and/or hypoglycemia unawareness.(10,11) Recognizing the importance of glucose monitoring, especially for insulin-treated patients, the ADA recommends that most patients using intensive insulin regimens (multi…”
BackgroundThe role of structured education in the management of hypoglycaemia
Iqbal, A., & Heller, S. R. (2018) · Diabetologia · doi:10.1007/s00125-017-4334-z · Cited by 78
“BGAT Blood Glucose Awareness Training CGM Continuous glucose monitoring CSII Continuous subcutaneous insulin infusion DAFNE Dose Adjustment for Normal Eating DAFNE-HART DAFNE-Hypoglycaemia Awareness Restoration Training DTTP Diabetes Treatment and Teaching programme HAATT Hypoglycemia Anticipation, Awareness and Treat…”
BackgroundInfluentialBruttomesso, D., Laviola, L., Avogaro, A., Bonora, E., Del Prato, S., Frontoni, S., Orsi, E., Rabbone, I., Sesti, G., & Purrello, F. (2019) · Nutrition, Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2019.01.018 · Cited by 72
“The impact of rtCGM has been tested in the HypoDE study [20] on patients with impaired hypoglycaemia awareness or severe hypoglycaemia treated with MDI, and in the IN CONTROL study [18] on patients with impaired hypoglycaemia awareness.”
MethodResultMesa, A., Viñals, C., Pueyo, I., Roca, D., Vidal, M., Giménez, M., & Conget, I. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108354 · Cited by 69
Petruzelkova, L., Soupal, J., Plasova, V., Jiranova, P., Neuman, V., Plachy, L., Pruhova, S., Sumnik, Z., & Obermannova, B. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0214 · Cited by 68
Rickels, M. R. (2019) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14214 · Cited by 71
Current Diabetes Technology: Striving for the Artificial Pancreas
Allen, N., & Gupta, A. (2019) · Diagnostics · doi:10.3390/diagnostics9010031 · Cited by 65
“Studies have shown that CGM use can increase time spent in normoglycemia and decrease the frequency and severity of hypoglycemia episodes [4,5].”
BackgroundSelecting the Appropriate Continuous Glucose Monitoring System – a Practical Approach
Adolfsson, P., Parkin, C. G., Thomas, A., & Krinelke, L. G. (2018) · European Endocrinology · doi:10.17925/ee.2018.14.1.24 · Cited by 63
Rayan, M. N., Reddy, N., Verma, N., & Dungan, K. M. (2026) · PubMed · Cited by 110
Hermanns, N., Heinemann, L., Freckmann, G., Waldenmaier, D., & Ehrmann, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819831695 · Cited by 66
Time in range centered diabetes care
Dovč, K., & Battelino, T. (2021) · Clinical Pediatric Endocrinology · doi:10.1297/cpe.30.1 · Cited by 70
Continuous Glucose Monitoring and Global Reimbursement: An Update
Graham, C. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0096 · Cited by 62
“A recently published randomized, open-label crossover design study examined the effects of RT-CGM on time spent in normoglycemia (70– 180 mg/dL; primary end point) and incidence of severe hypoglycemia (requiring third party assistance; secondary end point) in patients with T1DM and impaired awareness of hypoglycemia i…”
BackgroundInfluentialNatale, P., Chen, S., Chow, C. K., Cheung, N. W., Martinez‐Martin, D., Caillaud, C., Scholes‐Robertson, N., Kelly, A., Craig, J. C., Strippoli, G., et al. (2023) · Journal of Diabetes · doi:10.1111/1753-0407.13454 · Cited by 63
Continuous Glucose Monitoring Use in Older Adults for Optimal Diabetes Management
Munshi, M. N. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0111 · Cited by 63
Rickels, M. R., Peleckis, A. J., Dalton-Bakes, C., Naji, J. R., Ran, N. A., Nguyen, H.-L., O’Brien, S., Chen, S., Lee, I., & Schutta, M. H. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2017-01516 · Cited by 60
“glycemia events with CGM, but without an effect on hypoglycemia awareness (34).”
BackgroundRoos, T., Hermanns, N., Groß, C., Kulzer, B., Haak, T., & Ehrmann, D. (2024) · EClinicalMedicine · doi:10.1016/j.eclinm.2024.102852 · Cited by 62
Kang, S., Kang, S. M., Choi, J. H., Ko, S., Koo, B. K., Kwon, H.-S., Kim, M. K., Kim, S. Y., Kim, S., Kim, Y., et al. (2025) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2025.0469 · Cited by 85
Reference Guide for Integrating Continuous Glucose Monitoring Into Clinical Practice
Kruger, D. F., Edelman, S. V., Hinnen, D. A., & Parkin, C. G. (2019) · The Diabetes Educator · doi:10.1177/0145721718818066 · Cited by 55
Chamberlain, J. J., Doyle-Delgado, K., Peterson, L., & SKOLNIK, N. (2019) · Annals of Internal Medicine · doi:10.7326/m19-1638 · Cited by 60
Severe Hypoglycemia: Is It Still a Threat for Children and Adolescents With Type 1 Diabetes?
Urakami, T. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00609 · Cited by 59
Fallon, C., Jones, E., Oliver, N. S., Reddy, M., & Avari, P. (2022) · Diabetic Medicine · doi:10.1111/dme.14906 · Cited by 58
Choudhary, P., & Amiel, S. A. (2018) · Diabetologia · doi:10.1007/s00125-018-4566-6 · Cited by 52
“On the other hand, the IN CONTROL study [35], which also”
Continuous Glucose Monitoring with Multiple Daily Insulin Treatment: Outcome Studies
McGill, J. B., & Ahmann, A. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0090 · Cited by 49
Kaiser, N., Gautschi, M., Bošanská, L., Meienberg, F., Baumgartner, M. R., Spinas, G. A., & Hochuli, M. (2019) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2019.02.008 · Cited by 50
Friedman, J. G., Cardona, Z., Szmuilowicz, E. D., & Aleppo, G. (2023) · Pharmacogenomics and Personalized Medicine · doi:10.2147/pgpm.s374663 · Cited by 61
“Significantly less severe hypoglycemia events in this highrisk population were also observed.(22) Additionally, data from the WISDM trial suggests that use of CGM in older adults with T1D improves both glycemic control and reduces hypoglycemia events.”
BackgroundDiabetes Technology Use in Adults with Type 1 and Type 2 Diabetes
Kravarusic, J., & Aleppo, G. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.006 · Cited by 42
Rondags, S. M. P. A., de Wit, M., Twisk, J. W., & Snoek, F. J. (2016) · Diabetes Care · doi:10.2337/dc16-1614 · Cited by 45
“We added RT-CGMuse as a confounder in the main analyses and can speculate that the effects of HypoAware aremore pronounced in a patient population without RT-CGM use because RT-CGM has been found to be effective in preventing severe hypoglycemia (26).”
MethodSelf-citationThieu, V. T., Mitchell, B. D., Varnado, O. J., & Frier, B. M. (2020) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13941 · Cited by 44
Sherrill, C. H., Houpt, C. T., Dixon, E. M., & Richter, S. J. (2020) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2020.26.5.600 · Cited by 55
Reddy, M., & Oliver, N. S. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15504 · Cited by 47
Artificial Pancreas: Current Progress and Future Outlook in the Treatment of Type 1 Diabetes
Ramli, R., Reddy, M., & Oliver, N. S. (2019) · Drugs · doi:10.1007/s40265-019-01149-2 · Cited by 48
Svedman, C., Bruze, M., Antelmi, A., Hamnerius, N., Hauksson, I., Ulriksdotter, J., & Mowitz, M. (2020) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.16981 · Cited by 44
Metadata
- Authors
- van Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H.
- Affiliations
- Amsterdam UMC Location University of Amsterdam (NL)
- Amsterdam UMC Location Vrije Universiteit Amsterdam (NL)
- Medisch Centrum Haaglanden (NL)
- ORCID
- Venue
- The Lancet Diabetes & Endocrinology
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 4
- Issue
- 11
- Pages
- 893-902
- ISSN
- 2213-8587 (ISSN-L)
- OpenAlex
- W2519559406
- Semantic Scholar
- c0ce6cdf2bed457df361f278a804bc87920252f4
- Cited by
- 386
- References
- 34
- Citations by year
- 2026: 18 · 2025: 24 · 2024: 46 · 2023: 38 · 2022: 39 · 2021: 53 · 2020: 40 · 2019: 52 · 2018: 39 · 2017: 32 · 2016: 4
- FWCI
- 42.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet Diabetes & Endocrinology (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Funders
- Eli Lilly and Company
- AstraZeneca
- Sanofi
- Vrije Universiteit Amsterdam
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, type 1 diabetes, impaired awareness of hypoglycaemia, severe hypoglycemia, self-monitoring of blood glucose, glycemic control, insulin pump therapy, multiple daily insulin injections, hypoglycemia prevention, real-time glucose monitoring
- MeSH terms
- Adult, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Female, Humans, Hypoglycemia, Male, Middle Aged, Blood Glucose Self-Monitoring, Cross-Over Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.