The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Laser Ablation Electrospray Ionization for Atmospheric Pressure, in Vivo, and Imaging Mass Spectrometry
Abstract
Mass spectrometric analysis of biomolecules under ambient conditions promises to enable the in vivo investigation of diverse biochemical changes in organisms with high specificity. Here we report on a novel combination of infrared laser ablation with electrospray ionization (LAESI) as an ambient ion source for mass spectrometry. As a result of the interactions between the ablation plume and the spray, LAESI accomplishes electrospray-like ionization. Without any sample preparation or pretreatment, this technique was capable of detecting a variety of molecular classes and size ranges (up to 66 kDa) with a detection limit of 8 and 25 fmol for verapamil and reserpine, respectively, and quantitation capabilities with a four-decade dynamic range. We demonstrated the utility of LAESI in a broad variety of applications ranging from plant biology to clinical analysis. Proteins, lipids, and metabolites were identified, and antihistamine excretion was followed via the direct analysis of bodily fluids (urine, blood, and serum). We also performed in vivo spatial profiling (on leaf, stem, and root) of metabolites in a French marigold (Tagetes patula) seedling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
Stoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172
Shiea, J., Huang, M., HSu, H., Lee, C., Yuan, C., Beech, I., & Sunner, J. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2243 · Cited by 481
Sampson, J. S., Hawkridge, A. M., & Muddiman, D. C. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.08.003 · Cited by 375
Berkenkamp, S., Karas, M., & Hillenkamp, F. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.14.7003 · Cited by 149
Molimard, M., Diquet, B., & Benedetti, M. S. (2004) · Fundamental and Clinical Pharmacology · doi:10.1111/j.1472-8206.2004.00254.x · Cited by 148
Flexing the Electrified Meniscus: The Birth of a Jet in Electrosprays
Marginean, I., Parvin, L., Heffernan, L., & Vértes, Á. (2004) · Analytical Chemistry · doi:10.1021/ac049817r · Cited by 130
Laiko, V. V., Taranenko, N. I., Berkout, V. D., et al. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00341-0 · Cited by 104
Gas-phase diagnostics and LIF-imaging of 3-hydroxypicolinic acid maldi-matrix plumes
Puretzky, A. A., & Geohegan, D. B. (1998) · Chemical Physics Letters · doi:10.1016/s0009-2614(98)00013-x · Cited by 82
Cited by
Paper Spray for Direct Analysis of Complex Mixtures Using Mass Spectrometry
Wang, H., Liu, J., Cooks, R. G., & Ouyang, Z. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906314 · Cited by 771
Low-Temperature Plasma Probe for Ambient Desorption Ionization
Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac801641a · Cited by 730
Development, Characterization, and Application of Paper Spray Ionization
Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z. (2010) · Analytical Chemistry · doi:10.1021/ac902854g · Cited by 711
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Ambient desorption ionization mass spectrometry
Venter, A., Nefliu, M., & Graham Cooks, R. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.01.010 · Cited by 552
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Ambient Ionization Mass Spectrometry: Recent Developments and Applications
Feider, C. L., Krieger, A., DeHoog, R. J., & Eberlin, L. S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00807 · Cited by 496
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Desorption electrospray ionization mass spectrometry: Imaging drugs and metabolites in tissues
Wiseman, J. M., Ifa, D. R., Zhu, Y., Kissinger, C. B., Manicke, N. E., Kissinger, P. T., & Cooks, R. G. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801066105 · Cited by 460
Ifa, D. R., Wu, C., Ouyang, Z., & Cooks, R. G. (2010) · The Analyst · doi:10.1039/b925257f · Cited by 384
Mass spectrometry imaging with laser-induced postionization
Soltwisch, J., Kettling, H., Vens-Cappell, S., Wiegelmann, M., Müthing, J., & Dreisewerd, K. (2015) · Science · doi:10.1126/science.aaa1051 · Cited by 382
Ethnobotany and the Role of Plant Natural Products in Antibiotic Drug Discovery
Porras, G., Chassagne, F., Lyles, J. T., Marquez, L., Dettweiler, M., Salam, A. M., Samarakoon, T., Shabih, S., Farrokhi, D. R., & Quave, C. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00922 · Cited by 378
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Spatially resolved metabolomics to discover tumor-associated metabolic alterations
Sun, C., Li, T., Song, X., Huang, L., Zang, Q., Xu, J., Bi, N., Jiao, G., Hao, Y., Chen, Y., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1808950116 · Cited by 364
Weston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
Profiling metabolites and peptides in single cells
Rubakhin, S. S., Romanova, E. V., Nemes, P., & Sweedler, J. V. (2011) · Nature Methods · doi:10.1038/nmeth.1549 · Cited by 347
Self-citationAmbient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Imaging mass spectrometry in microbiology
Watrous, J. D., & Dorrestein, P. C. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2634 · Cited by 338
Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry
Laskin, J., Heath, B. S., Roach, P. J., Cazares, L., & Semmes, O. J. (2012) · Analytical Chemistry · doi:10.1021/ac2021322 · Cited by 338
Ouyang, Z., & Cooks, R. G. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155229 · Cited by 323
Ambient ionization mass spectrometry: A tutorial
Huang, M.-Z., Cheng, S.-C., Cho, Y.-T., & Shiea, J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.017 · Cited by 320
Ambient Ionization Mass Spectrometry
Huang, M.-Z., Yuan, C.-H., Cheng, S.-C., Cho, Y.-T., & Shiea, J. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073702 · Cited by 306
Mass spectrometry imaging for plant biology: a review
Boughton, B. A., Thinagaran, D., Sarabia, D., Bacic, A., & Roessner, U. (2016) · Phytochemistry Reviews · doi:10.1007/s11101-015-9440-2 · Cited by 300
Van Berkel, G. J., Pasilis, S. P., & Ovchinnikova, O. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1440 · Cited by 299
Advances in mass spectrometry-based clinical biomarker discovery
Crutchfield, C. A., Thomas, S. N., Sokoll, L. J., & Chan, D. W. (2016) · Clinical Proteomics · doi:10.1186/s12014-015-9102-9 · Cited by 292
Advances in mass spectrometry-based metabolomics for investigation of metabolites
Ren, J.-L., Zhang, A.-H., Kong, L., & Wang, X.-J. (2018) · RSC Advances · doi:10.1039/c8ra01574k · Cited by 291
Mass Spectrometry Imaging of Biomolecular Information
Spengler, B. (2015) · Analytical Chemistry · doi:10.1021/ac504543v · Cited by 290
Spatial Metabolomics and Imaging Mass Spectrometry in the Age of Artificial Intelligence
Alexandrov, T. (2020) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-011420-031537 · Cited by 284
Mass spectrometry imaging for drug distribution studies
Prideaux, B., & Stoeckli, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.07.028 · Cited by 279
Shrestha, B., & Vertes, A. (2009) · Analytical Chemistry · doi:10.1021/ac901525g · Cited by 273
Self-citationAtmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Sumner, L. W., Lei, Z., Nikolau, B. J., & Saito, K. (2015) · Natural Product Reports · doi:10.1039/c4np00072b · Cited by 233
Porta Siegel, T., Hamm, G., Bunch, J., Cappell, J., Fletcher, J. S., & Schwamborn, K. (2018) · Molecular Imaging and Biology · doi:10.1007/s11307-018-1267-y · Cited by 187
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Applications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time
Swiner, D. J., Jackson, S., Burris, B. J., & Badu-Tawiah, A. K. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04901 · Cited by 73
Metadata
- Authors
- Nemes, P., & Vertes, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-09-27
- Volume
- 79
- Issue
- 21
- Pages
- 8098-8106
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W4249005591
- Cited by
- 817
- References
- 14
- FWCI
- 17.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.