Top-Down Structural Analysis of an Intact Monoclonal Antibody by Electron Capture Dissociation-Fourier Transform Ion Cyclotron Resonance-Mass Spectrometry
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Top-down electron capture dissociation (ECD) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry was performed for structural analysis of an intact monoclonal antibody (IgG1kappa (κ) isotype, ~148 kDa). Simultaneous ECD for all charge states (42+ to 58+) generates more extensive cleavages than ECD for an isolated single charge state. The cleavages are mainly localized in the variable domains of both heavy and light chains, the respective regions between the variable and constant domains in both chains, the region between heavy-chain constant domains CH2 and CH3, and the disulfide bond (S-S)-linked heavy-chain constant domain CH3. The light chain yields mainly N-terminal fragment ions due to the protection of the interchain disulfide bond between light and heavy chain, and limited cleavage sites are observed in the variable domains for each chain, where the S-S spans the polypeptide backbone. Only a few cleavages in the S-S-linked light-chain constant domain, hinge region, and heavy-chain constant domains CH1 and CH2 are observed, leaving glycosylation uncharacterized. Top-down ECD with a custom-built 9.4 T FTICR mass spectrometer provides more extensive sequence coverage for structural characterization of IgG1κ than does top-down collision-induced dissociation (CID) and electron transfer dissociation (ETD) with hybrid quadrupole time-of-flight instruments and comparable sequence coverage for top-down ETD with orbitrap mass analyzers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Mapping intact protein isoforms in discovery mode using top-down proteomics
Tran, J. C., Zamdborg, L., Ahlf, D. R., Lee, J. E., Catherman, A. D., Durbin, K. R., Tipton, J. D., Vellaichamy, A., Kellie, J. F., Li, M., et al. (2011) · Nature · doi:10.1038/nature10575 · Cited by 665
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Zamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Ge, Y., Rybakova, I. N., Xu, Q., & Moss, R. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813369106 · Cited by 154
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Self-citation
Cited by
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Feist, P., & Hummon, A. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16023537 · Cited by 288
Fekete, S., Guillarme, D., Sandra, P., & Sandra, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04561 · Cited by 258
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Fornelli, L., Srzentić, K., Huguet, R., Mullen, C., Sharma, S., Zabrouskov, V., Fellers, R. T., Durbin, K. R., Compton, P. D., & Kelleher, N. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00984 · Cited by 150
Shaw, J. B., Liu, W., Vasil′ev, Y. V., Bracken, C. C., Malhan, N., Guthals, A., Beckman, J. S., & Voinov, V. G. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03129 · Cited by 77
40 years of Fourier transform ion cyclotron resonance mass spectrometry
Marshall, A. G., & Chen, T. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2014.06.034 · Cited by 70
Self-citationJin, Y., Lin, Z., Xu, Q., Fu, C., Zhang, Z., Zhang, Q., Pritts, W. A., & Ge, Y. (2019) · mAbs · doi:10.1080/19420862.2018.1525253 · Cited by 68
Zhao, Y., Sun, L., Knierman, M. D., & Dovichi, N. J. (2016) · Talanta · doi:10.1016/j.talanta.2015.11.020 · Cited by 49
Middle-Down Multi-Attribute Analysis of Antibody-Drug Conjugates with Electron Transfer Dissociation
Chen, B., Lin, Z., Zhu, Y., Jin, Y., Larson, E., Xu, Q., Fu, C., Zhang, Z., Zhang, Q., Pritts, W. A., et al. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02194 · Cited by 38
Metadata
- Authors
- Mao, Y., Valeja, S. G., Rouse, J. C., Hendrickson, C. L., & Marshall, A. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-04-03
- Volume
- 85
- Issue
- 9
- Pages
- 4239-4246
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2056580789
- Cited by
- 129
- References
- 9
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.