High-Throughput Screening (HTS) of Anticancer Drug Efficacy on a Micropillar/Microwell Chip Platform
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Contemporary cancer therapy refers to treatment based on genetic abnormalities found in patient's tumor. However, this approach is faced with numerous challenges, including tumor heterogeneity and molecular evolution, insufficient tumor samples available along with genetic information linking to clinical outcomes, lack of therapeutic drugs containing pharmacogenomic information, and technical limitations of rapid drug efficacy tests with insufficient quantities of primary cancer cells from patients. To address these problems and improve clinical outcomes of current personalized gene-targeted cancer therapy, we have developed a micropillar/microwell chip platform, which is ideally suited for encapsulating primary cancer cells in nanoscale spots of hydrogels on the chip, generating efficacy data with various drugs, eventually allowing for a comparison of the in vitro data obtained from the chip with clinical data as well as gene expression data. As a proof of concept in this study, we have encapsulated a U251 brain cancer cell line and three primary brain cancer cells from patients (448T, 464T, and 775T) in 30 nL droplets of alginate and then tested the therapeutic efficacy of 24 anticancer drugs by measuring their dose responses. As a result, the IC50 values of 24 anticancer drugs obtained from the brain cancer cells clearly showed patient cell-specific efficacy, some of which were well-correlated with their oncogene overexpression (c-Met and FGFR1) as well as the in vivo previous results of the mouse xenograft model with the three primary brain cancer cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
The Path to Personalized Medicine
Hamburg, M. A., & Collins, F. S. (2010) · New England Journal of Medicine · doi:10.1056/nejmp1006304 · Cited by 1,970
Modeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Spheroid-based drug screen: Considerations and practical approach
Friedrich, J., Seidel, C., Ebner, R., & Kunz-Schughart, L. A. (2009) · Nature Protocols · doi:10.1038/nprot.2008.226 · Cited by 1,742
Three-Dimensional Cell Culture Matrices: State of the Art
Lee, J., Cuddihy, M. J., & Kotov, N. A. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/teb.2007.0150 · Cited by 1,047
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
3D Matrices for Anti-Cancer Drug Testing and Development
Gurski, L. A., Petrelli, N. J., Jia, X., & Farach-Carson, M. C. (2010) · Oncology Issues · doi:10.1080/10463356.2010.11883480 · Cited by 130
Biomarkers for simplifying HTS 3D cell culture platforms for drug discovery: the case for cytokines
Lai, Y., Asthana, A., & Kisaalita, W. S. (2011) · Drug Discovery Today · doi:10.1016/j.drudis.2011.01.009 · Cited by 43
Wu, M.-H., Chang, Y.-H., Liu, Y.-T., Chen, Y.-M., Wang, S.-S., Wang, H.-Y., Lai, C.-S., & Pan, T.-M. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.11.027 · Cited by 42
Cited by
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
3D bioprinting for drug discovery and development in pharmaceutics
Peng, W., Datta, P., Ayan, B., Ozbolat, V., Sosnoski, D., & Ozbolat, I. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.025 · Cited by 313
Kim, K.-T., Lee, H. W., Lee, H.-O., Kim, S. C., Seo, Y. J., Chung, W., Eum, H. H., Nam, D.-H., Kim, J., Joo, K. M., et al. (2015) · Genome Biology · doi:10.1186/s13059-015-0692-3 · Cited by 268
Self-citationKim, K.-T., Lee, H. W., Lee, H.-O., Song, H. J., Jeong, D. E., Shin, S., Kim, H., Shin, Y., Nam, D.-H., Jeong, B. C., et al. (2016) · Genome Biology · doi:10.1186/s13059-016-0945-9 · Cited by 198
Self-citationBioprinting towards physiologically relevant tissue models for pharmaceutics
Peng, W., Unutmaz, D., & Ozbolat, I. T. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.05.013 · Cited by 196
Unger, C., Kramer, N., Walzl, A., Scherzer, M., Hengstschläger, M., & Dolznig, H. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.10.015 · Cited by 158
Metadata
- Authors
- Lee, D. W., Choi, Y.-S., Seo, Y. J., Lee, M.-Y., Jeon, S. Y., Ku, B., Kim, S., Yi, S. H., & Nam, D.-H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-12-02
- Volume
- 86
- Issue
- 1
- Pages
- 535-542
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2050845614
- Cited by
- 110
- References
- 9
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.