Solvent Microextraction into a Single Drop
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An analytical technique is described which combines solvent extraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little solvent consumption. A small drop (8 μL) of a water-immiscible organic solvent, containing an internal standard, is located at the end of a Teflon rod which is immersed in a stirred aqueous sample solution. After the solution has been stirred for a prescribed period of time, the probe is withdrawn from the aqueous solution, and the organic phase is sampled with a microsyringe and injected into the GC for quantification. The observed rate of solvent extraction is in good agreement with a convective-diffusive kinetic model. Analytically, the relative standard deviation of the method is 1.7% for a 5.00-min extraction of the analyte 4-methylacetophenone into n-octane.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various methods like agitation, stirring, vibration, shaking, and irradiation with ultrasonic waves have been applied to improve the extraction efficiency of LPME methods via increasing the mass transfer rate [83,168].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [168]
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Handbook of Solvent Extraction
Lo, T. C., Baird, M. H. I., & Hanson, C. A. (1991) · Cited by 983
Automation and optimization of solid-phase microextraction
Arthur, C. L., Killam, L. M., Buchholz, K. D., Pawliszyn, J., & Berg, J. R. (1992) · Analytical Chemistry · doi:10.1021/ac00041a034 · Cited by 620
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Membrane approach to solid-phase extractions
Hagen, D. F., Markell, C. G., Schmitt, G. A., & Blevins, D. D. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83309-7 · Cited by 235
The Kinetics of Metal Solvent Extraction
Danesi, P. R., Chiarizia, R., & Coleman, C. F. (1980) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408348008085494 · Cited by 222
Measurement of liquid-liquid interfacial kinetics
Hanna, G. J., & Noble, R. D. (1985) · Chemical Reviews · doi:10.1021/cr00070a004 · Cited by 151
Interfacial transfer studied with a rotating diffusion cell
Albery, W. J., Burke, J. F., Leffler, E. B., & Hadgraft, J. (1976) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19767201618 · Cited by 144
Some Measurements of Diffusion in Liquids.
Chang, P., & Wilke, C. R. (1955) · The Journal of Physical Chemistry · doi:10.1021/j150529a005 · Cited by 143
Transport phenomena in liquid extraction
Laddha, G. S., & Degaleesan, T. E. (1976) · Andalas University Repository (Andalas University) · Cited by 123
Research works printed but not linked: 7
- Lucy C. A., 1994, Anal. Chem., 66, 2225
- Davies, J. T.; Rideal, E. K. Interfacial Phenomena ; Academic Press: New York, 1961; Chapter 7.
- Grushka E., 1974, J. Phys. Chem., 78, 2301
- Liley, P. E.; Reid, R. C.; Buck, E. In Chemical Engineers' Handbook , 6th ed.; Perry, R. H., Green, D. W., Eds.; McGraw-Hill: New York, 1984; Chapter 3, pp 258−259.
- Laddha G. S., 1976, Transport Phenomena in Liquid Extraction
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
Cited by
Items 701–800 of 1,001
Springer, V., & Lista, A. G. (2015) · Electrophoresis · doi:10.1002/elps.201400602 · Cited by 25
Tan, L., Zhao, X., Liu, X. Q., Ju, H., & Li, J. S. (2005) · Chromatographia · doi:10.1365/s10337-005-0604-x · Cited by 25
Jouyban, A., Farajzadeh, M. A., Khoubnasabjafari, M., Jouyban-Gharamaleki, V., & Afshar Mogaddam, M. R. (2019) · Analytical Methods · doi:10.1039/c8ay02279h · Cited by 24
Daşbaşı, T., Saçmacı, Ş., Ülgen, A., & Kartal, Ş. (2015) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2015.03.009 · Cited by 24
Yamini, Y., Ghambarian, M., Esrafili, A., Yazdanfar, N., & Moradi, M. (2012) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2010.548098 · Cited by 26
Liquid-phase microextraction of biomarkers: A review on current methods
Hamidi, S., & Alipour-Ghorbani, N. (2017) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2017.1374291 · Cited by 24
“The device directly dipped in the sample or suspended above the solution into the void space for headspace extraction.([13,14]) Latter one is known as headspace SDME (HS-SDME), which is suitable for concentration of the volatile analytes in the solution.”
BackgroundJain, A., & Verma, K. K. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816911-7.00015-3 · Cited by 29
Miniaturized systems for gas chromatography: Developments in sample preparation and instrumentation
Crucello, J., de Oliveira, A. M., Sampaio, N. M. F. M., & Hantao, L. W. (2022) · Journal of Chromatography A · doi:10.1016/j.chroma.2022.463603 · Cited by 29
Azorín, C., Benedé, J. L., & Chisvert, A. (2023) · Journal of Separation Science · doi:10.1002/jssc.202300223 · Cited by 28
Pantůčková, P., Kubáň, P., & Boček, P. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.07.004 · Cited by 28
Kawaguchi, M., & Takatsu, A. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.12.022 · Cited by 24
Farajzadeh, M. A., Khorram, P., & Nabil, A. A. A. (2014) · Journal of Separation Science · doi:10.1002/jssc.201301306 · Cited by 24
SAMPLE PREPARATION FOR HIGH PERFORMANCE LIQUID CHROMATOGRAPHY: RECENT PROGRESS
Cobzac, S. C. A., & Gocan, S. (2011) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2011.588064 · Cited by 25
Hu, S., Song, Y., Bai, X., Jiang, X., & Yang, X. (2013) · CLEAN - Soil Air Water · doi:10.1002/clen.201200374 · Cited by 26
Hashemi, M., Zohrabi, P., & Torkejokar, M. (2016) · Separation and Purification Technology · doi:10.1016/j.seppur.2016.11.073 · Cited by 24
Nanosensors for detection of pesticides in water
Steffens, C., Steffens, J., Graboski, A. M., Manzoli, A., & Leite, F. L. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804299-1.00017-5 · Cited by 26
A comparison study of analytical performance of chromium speciation methods
József, P., Nagy, D., Kapitány, S., & Béni, Á. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.05.058 · Cited by 24
Elahi, F., Arain, M. B., Khan, W. A., Shah, N., & Kazi, T. G. (2020) · Chemical Papers · doi:10.1007/s11696-020-01337-5 · Cited by 25
In-vessel headspace liquid-phase microextraction
Tamen, A.-E., & Vishnikin, A. B. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338670 · Cited by 24
Nakatani, K., Sudo, M., & Kitamura, N. (1999) · Analytical Chemistry · doi:10.1021/ac981297a · Cited by 24
Mohammadkhani, E., Yamini, Y., Rezazadeh, M., & Seidi, S. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.03.067 · Cited by 23
Vessally, E., Kalhor, E. G., Hosseinzadeh‐Khanmiri, R., Babazadeh, M., Hosseinian, A., Omidi, F., & Ebrahimi, M. H. (2017) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-017-1249-z · Cited by 23
Alahyari, E., Setareh, M., Shekari, A., Roozbehani, G., & Soltaninejad, K. (2018) · Egyptian Journal of Forensic Sciences · doi:10.1186/s41935-018-0046-x · Cited by 23
“For example, liquid-phase microextraction (LPME) was successfully used for extraction of analytes from aqueous samples (Jeannot and Cantwell 1996; He and Lee 1997).”
MethodDispersive Liquid-Liquid Microextraction
Kokosa, J. M. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816911-7.00016-5 · Cited by 34
Single-drop microextraction for the determination of manganese in seafood and water samples
Lemos, V. A., & Vieira, U. S. (2013) · Microchimica Acta · doi:10.1007/s00604-013-0961-3 · Cited by 23
“Among various liquid–liquid extraction techniques, single-drop microextraction (SDME) has been recently described in the literature [14–19].”
BackgroundMethodSereshti, H., Bakhtiari, S., & Khojeh, V. (2011) · Analytical Methods · doi:10.1039/c1ay05456b · Cited by 23
Marsol‐Vall, A., Balcells, M., Eras, J., & Canela, R. (2017) · Food Chemistry · doi:10.1016/j.foodchem.2017.06.070 · Cited by 23
Extraction of trace organic pollutants from aqueous samples by a single drop method
Ligor, T., & Buszewski, B. (2000) · Chromatographia · doi:10.1007/bf02492818 · Cited by 23
Majors, R. E. (2010) · Wiley eBooks · doi:10.1002/9780813823621.ch4 · Cited by 23
Dispersive Liquid–Liquid Microextraction
Cruz‐Vera, M. (2010) · Wiley eBooks · doi:10.1002/9780470027318.a9172 · Cited by 23
A review in the sample preparation of aqueous solutions combined with X-ray fluorescence detection
Moradi, M., Yamini, Y., Kakehmam, J., & Ahmadi, K. (2014) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-014-0545-0 · Cited by 22
Heidari, H., Razmi, H., & Jouyban, A. (2014) · Journal of Separation Science · doi:10.1002/jssc.201400030 · Cited by 23
Havlíková, M., Čabala, R., Pacáková, V., Bursová, M., & Bosáková, Z. (2018) · Journal of Separation Science · doi:10.1002/jssc.201800902 · Cited by 22
Critical review on microextraction techniques used in determination of histamine in food samples
Jayasinghe, G. D. T. M., Jinadasa, B. K. K. K., Pohl, P., & Aydi, A. (2022) · Discover Food · doi:10.1007/s44187-022-00008-6 · Cited by 22
“At the same time Jeannot and Cantwell [62] introduced a new solvent microextraction technique, which used micro drops of organic solvent suspended at the end of a Teflon rod immersed in a stirred aqueous sample solution [62].”
BackgroundShu, M.-W., Leong, M., Fuh, M., & Huang, S. (2012) · The Analyst · doi:10.1039/c2an16117f · Cited by 23
Pillai, A. K. K. V., Jain, A., & Verma, K. K. (2009) · Talanta · doi:10.1016/j.talanta.2009.10.027 · Cited by 24
Temperature-controlled headspace liquid-phase microextraction device using volatile solvents
Chen, S., Peng, H., Wu, D., & Guan, Y. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.07.033 · Cited by 22
Afzali, D., Bahadori, B., & Fathirad, F. (2013) · Toxicological & Environmental Chemistry Reviews · doi:10.1080/02772248.2013.856912 · Cited by 23
“Recently, a new mode of LPME based on solidification of floating organic droplet (LPME-SFO) was developed (Khalili Zanjani et al. 2007).”
MethodInfluentialPantůčková, P., Kubáň, P., & Boček, P. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.02.026 · Cited by 25
Wang, X., Cheng, J., Wang, X., Wu, M., & Cheng, M. (2012) · The Analyst · doi:10.1039/c2an35623f · Cited by 22
Khayatian, G., & Hassanpoor, S. (2012) · Journal of the Chinese Chemical Society · doi:10.1002/jccs.201100447 · Cited by 22
Vacuum-assisted headspace single-drop microextraction: Eliminating interfacial gas-phase limitations
Psillakis, E., Koutela, N., & Colussi, A. J. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.09.056 · Cited by 24
Farajzadeh, M. A., Pezhhanfar, S., & Mohebbi, A. (2019) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2019.1685667 · Cited by 24
Zhang, X., Oakes, K. D., Luong, D. D., Wen, J. Z., Metcalfe, C. D., Pawliszyn, J. B., & Servos, M. R. (2010) · Analytical Chemistry · doi:10.1021/ac102186u · Cited by 22
Gupta, M., Pillai, A. K. K. V., Jain, A., & Verma, K. K. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.042 · Cited by 22
Cho, J., Kim, K., & Lee, J.-G. (2025) · Applied Biological Chemistry · doi:10.1186/s13765-025-01063-0 · Cited by 25
“…as LLE and SPE, a range of microextraction techniques— including solid-phase microextraction (SPME) [42, 43], single-drop microextraction (SDME) [44], hollow fiber liquid-phase microextraction (HF-LPME) [45], stir-bar sorptive extraction (SBSE) [46], cloud point extraction (CPE) [47], and…”
Hoseininezhad-Namin, M. S., Rahimpour, E., Özkan, S. A., & Jouyban, A. (2022) · Analytical Methods · doi:10.1039/d1ay01833g · Cited by 21
Traditional methods and biosensors for detecting disinfection by-products in water: A review
Wu, T., Karimi‐Maleh, H., Drăgoi, E.-N., Puri, P., Zhang, D., & Zhang, Z. (2023) · Environmental Research · doi:10.1016/j.envres.2023.116935 · Cited by 21
Miniaturized liquid chromatography in environmental analysis. A review
Cortés-Bautista, S., Molins-Legua, C., & Campíns-Falcó, P. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.465101 · Cited by 26
A highly efficient three-phase single drop microextraction technique for sample preconcentration
Jahan, S., Xie, H., Zhong, R., Yan, J., Xiao, H., Fan, L.-Y., & Cao, C. (2015) · The Analyst · doi:10.1039/c4an02324b · Cited by 21
Tapadia, K., Shrivas, K. K., & Upadhyay, L. S. B. (2011) · Chromatographia · doi:10.1007/s10337-011-2096-1 · Cited by 23
Saraji, M., & Farajmand, B. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.01.046 · Cited by 21
Sheikhloie, H., Saber-Tehrani, M., Abrumand-Azar, P., & Waqif-Husain, S. (2009) · Acta Chromatographica · doi:10.1556/achrom.21.2009.4.5 · Cited by 21
Wang, J., Jiang, D., & Yan, X. (2005) · Talanta · doi:10.1016/j.talanta.2005.06.036 · Cited by 21
Wu, H., Kailasa, S. K., & Lin, C. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4843 · Cited by 21
Jahan, S., Zhang, Q., Pratush, A., Xie, H., Xiao, H., Fan, L.-Y., & Cao, C. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02514 · Cited by 21
Bazregar, M., Rajabi, M., Yamini, Y., & Asghari, A. (2018) · Journal of Separation Science · doi:10.1002/jssc.201800233 · Cited by 21
Miniaturized Sample Preparation Methods for Saliva Analysis
Seidi, S., Rezazadeh, M., & Alizadeh, R. (2018) · Bioanalysis · doi:10.4155/bio-2018-0160 · Cited by 23
Nunes, L. S., Korn, M. D. G. A., & Lemos, V. A. (2020) · Food Analytical Methods · doi:10.1007/s12161-020-01794-4 · Cited by 21
“SDME is an extraction technique based on the immersion of a drop of solvent (acceptor phase) within a donor phase (liquid or vapor) (Jeannot and Cantwell 1996; Kokosa 2015).”
MethodHarnessing bubble behaviors for developing new analytical strategies
An, S., Ranaweera, R., & Luo, L. (2020) · The Analyst · doi:10.1039/d0an01497d · Cited by 22
Pena‐Pereira, F., Duarte, R. M. B. O., & Duarte, A. C. (2011) · Open Chemistry · doi:10.2478/s11532-011-0114-7 · Cited by 25
Li, Y., Xiong, Y., Liang, Q., Fang, C., & Wang, C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.03.041 · Cited by 21
Ciucanu, I. (2002) · Analytical Chemistry · doi:10.1021/ac025834+ · Cited by 21
Shrivas, K. K., & Tapadia, K. (2015) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.07.032 · Cited by 20
Yazdi, A. S., Khaleghi-Miran, S.-H., & Es’haghi, Z. (2010) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067310902962593 · Cited by 21
Khan, S., Kazi, T. G., & Soylak, M. (2015) · Analytical Letters · doi:10.1080/00032719.2014.999280 · Cited by 21
Liu, Z., Liu, W., Rao, H., Feng, T., Li, C., Wang, C., & Wang, Z. (2012) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067311003628638 · Cited by 21
Rezaei, F., Yamini, Y., Asiabi, H., & Moradi, M. (2015) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2015.02.021 · Cited by 21
Yazdi, A. S., & Razavi, N. (2011) · Chromatographia · doi:10.1007/s10337-010-1900-7 · Cited by 21
Abreu, D. C. P., Botrel, B. M. C., Bazzana, M. J. F., Rosa, P. V., de Sales, P. F., Marques, M. D. S., & Saczk, A. A. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.07.136 · Cited by 20
Fang, C., Xiong, Y., Liang, Q., Li, Y., & Peng, P. (2011) · Organic Geochemistry · doi:10.1016/j.orggeochem.2011.01.009 · Cited by 20
Sun, M. Z., Du, W., & Fang, Q. (2006) · Talanta · doi:10.1016/j.talanta.2006.02.069 · Cited by 20
Shrivas, K. K., Dewangan, K., & Ahmed, A. (2016) · Analytical Methods · doi:10.1039/c6ay01277a · Cited by 22
Zhang, T., Chen, X., Li, Y., & Liang, P. (2006) · Chromatographia · doi:10.1365/s10337-006-0823-9 · Cited by 20
Zhang, H., & Andrews, A. R. J. (2000) · Journal of Environmental Monitoring · doi:10.1039/b006731h · Cited by 20
Vázquez, M. D. M. P., Vázquez, P. P., Galera, M. M., & Sánchez, L. M. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200222 · Cited by 21
Chen, P., Huang, S.-P., Fuh, M., & Huang, S. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.018 · Cited by 19
Rajabi, M., Kamalabadi, M., Jamali, M. R., Zolgharnein, J., & Asanjarani, N. (2012) · Human & Experimental Toxicology · doi:10.1177/0960327112455672 · Cited by 19
Asghari, A., Fazl-Karimi, H., Barfi, B., Rajabi, M., & Daneshfar, A. (2013) · Human & Experimental Toxicology · doi:10.1177/0960327113499166 · Cited by 21
“In the past few years, with the developing interest in a much simpler miniaturized configuration of extraction procedures, a novel liquid–liquid microextraction system named liquid-phase microextraction (LPME) was developed.(10) Because of rapidness, simplicity, and minimal use of solvent, LPME has attracted increasin…”
BackgroundMirmoghaddam, M., Kaykhaii, M., & Yahyavi, H. (2015) · Analytical Methods · doi:10.1039/c5ay01970b · Cited by 19
Šlampová, A., & Kubáň, P. (2019) · Talanta · doi:10.1016/j.talanta.2019.120255 · Cited by 19
Dias, F. D. S., Neto, S. C. D. S. R., Pires, L., & Lemos, V. A. (2020) · Analytical Methods · doi:10.1039/c9ay02453k · Cited by 19
Progress in Pretreatment and Analytical Methods of Coumarins: An Update since 2012 – A Review
Cui, D.-W., Zhang, Y., Duan, X.-Y., Zhou, Y. T., Li, G., & Feng, X. (2020) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2020.1750338 · Cited by 19
“LPME, also known as solvent microextraction, was first proposed in 1996 by Jeannot and Cantwell.”
BackgroundKalaboka, M., Chrimatopoulos, C., Jiménez‐Holgado, C., Boti, V. I., Sakkas, V. A., & Albanis, T. A. (2020) · Separations · doi:10.3390/separations7030046 · Cited by 20
Kokosa, J. M. (2021) · Sustainable Chemistry and Pharmacy · doi:10.1016/j.scp.2021.100478 · Cited by 22
Jin, M., Wang, X., Russel, M., & Shan, J. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.107743 · Cited by 19
Sobhi, H. R., Kashtiaray, A., Farahani, H., Abrahimpour, F., & Esrafili, A. (2010) · Drug Testing and Analysis · doi:10.1002/dta.131 · Cited by 19
Xu, H., Pan, W., Song, D., & Yang, G. (2007) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0718345 · Cited by 23
Alshana, U., Lubbad, I., Göğer, N. G., Çok, İ., Tamer, U., & Ertaş, N. (2013) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2012.725700 · Cited by 18
“Liquid–liquid microextraction (LLME) with its different operating modes, such as single drop microextraction (SDME),([26]) hollow fiber-based liquid-phase microextraction (HF-LPME),([27]) solvent-bar microextraction (SBME),([28]) and dispersive liquid–liquid microextraction (DLLME),([29]) among others, has attracted i…”
BackgroundBagheri, H., Piri‐Moghadam, H., Rastegar, S., & Taheri, N. (2014) · Journal of Separation Science · doi:10.1002/jssc.201400252 · Cited by 19
Headspace Solvent Microextraction of Trihalomethane Compounds into a Single Drop
Yamini, Y., Hosseini, M. H., Hojaty, M., & Arab, J. (2004) · Journal of Chromatographic Science · doi:10.1093/chromsci/42.1.32 · Cited by 19
Analysis of the Plant Volatile Fraction
Rubiolo, P., Sgorbini, B., Liberto, E., Cordero, C., & Bicchi, C. (2010) · Wiley eBooks · doi:10.1002/9780470669532.ch3 · Cited by 17
Old and New Flavors of Flame (Furnace) Atomic Absorption Spectrometry
Dionísio, A. G. G., de Jesus, A. M. D., Amais, R. S., Donati, G. L., Miranda, K., Guerra, M. B. B., Nóbrega, J. A., & Pereira‐Filho, E. R. (2011) · International Journal of Spectroscopy · doi:10.1155/2011/262715 · Cited by 20
“The idea behind this preconcentration method was developed by Jeannot and Cantwell [207].”
MethodWei, Z., Li, M., Zeng, H., & Zhang, X. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02239 · Cited by 18
Chen, H., Liu, H.-T., Kuo, Y., Yang, D.-P., Ting, T.-T., Chiu, J.-Y., Chiu, J.-Y., Jair, Y., Li, H.-C., Chiang, P.-J., et al. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2023.115443 · Cited by 18
Trtić‐Petrović, T. M., & Dimitrijević, A. (2013) · Open Chemistry · doi:10.2478/s11532-013-0352-y · Cited by 19
Zhu, Y., Cao, L., Hao, J., Qu, Q., Xin, S., & Zhang, H. (2010) · Microchimica Acta · doi:10.1007/s00604-010-0397-y · Cited by 18
“Liquid-phase microextraction (LPME) or solvent microextraction is a sample pre-treatment technique developed in the end of the last century [1, 2].”
BackgroundHashemi, P., Hosseini, S. M., Kakanejadifard, A., Azimi, G., & Zohrehvand, S. (2010) · Journal of the Chinese Chemical Society · doi:10.1002/jccs.201000018 · Cited by 20
Ramezanpour, M., Raeisi, S. N., Shahidi, S., & Ramezanpour, S. (2020) · Micro & Nano Letters · doi:10.1049/mnl.2019.0577 · Cited by 18
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Affiliations
- University of Alberta (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2236-2240
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973396905
- Cited by
- 1,282
- References
- 27
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 34 · 2021: 40 · 2020: 53 · 2019: 66 · 2018: 43 · 2017: 41 · 2016: 49 · 2015: 68 · 2014: 80 · 2013: 84 · 2012: 99
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- solvent extraction, gas chromatography, solvent reduction, 4-methylacetophenone, n-octane, internal standard
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.