Solvent Microextraction into a Single Drop
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An analytical technique is described which combines solvent extraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little solvent consumption. A small drop (8 μL) of a water-immiscible organic solvent, containing an internal standard, is located at the end of a Teflon rod which is immersed in a stirred aqueous sample solution. After the solution has been stirred for a prescribed period of time, the probe is withdrawn from the aqueous solution, and the organic phase is sampled with a microsyringe and injected into the GC for quantification. The observed rate of solvent extraction is in good agreement with a convective-diffusive kinetic model. Analytically, the relative standard deviation of the method is 1.7% for a 5.00-min extraction of the analyte 4-methylacetophenone into n-octane.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various methods like agitation, stirring, vibration, shaking, and irradiation with ultrasonic waves have been applied to improve the extraction efficiency of LPME methods via increasing the mass transfer rate [83,168].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [168]
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Handbook of Solvent Extraction
Lo, T. C., Baird, M. H. I., & Hanson, C. A. (1991) · Cited by 983
Automation and optimization of solid-phase microextraction
Arthur, C. L., Killam, L. M., Buchholz, K. D., Pawliszyn, J., & Berg, J. R. (1992) · Analytical Chemistry · doi:10.1021/ac00041a034 · Cited by 620
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Membrane approach to solid-phase extractions
Hagen, D. F., Markell, C. G., Schmitt, G. A., & Blevins, D. D. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83309-7 · Cited by 235
The Kinetics of Metal Solvent Extraction
Danesi, P. R., Chiarizia, R., & Coleman, C. F. (1980) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408348008085494 · Cited by 222
Measurement of liquid-liquid interfacial kinetics
Hanna, G. J., & Noble, R. D. (1985) · Chemical Reviews · doi:10.1021/cr00070a004 · Cited by 151
Interfacial transfer studied with a rotating diffusion cell
Albery, W. J., Burke, J. F., Leffler, E. B., & Hadgraft, J. (1976) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19767201618 · Cited by 144
Some Measurements of Diffusion in Liquids.
Chang, P., & Wilke, C. R. (1955) · The Journal of Physical Chemistry · doi:10.1021/j150529a005 · Cited by 143
Transport phenomena in liquid extraction
Laddha, G. S., & Degaleesan, T. E. (1976) · Andalas University Repository (Andalas University) · Cited by 123
Research works printed but not linked: 7
- Lucy C. A., 1994, Anal. Chem., 66, 2225
- Davies, J. T.; Rideal, E. K. Interfacial Phenomena ; Academic Press: New York, 1961; Chapter 7.
- Grushka E., 1974, J. Phys. Chem., 78, 2301
- Liley, P. E.; Reid, R. C.; Buck, E. In Chemical Engineers' Handbook , 6th ed.; Perry, R. H., Green, D. W., Eds.; McGraw-Hill: New York, 1984; Chapter 3, pp 258−259.
- Laddha G. S., 1976, Transport Phenomena in Liquid Extraction
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
Cited by
Items 101–200 of 1,001
Ramos‐Payán, M., Bello‐López, M. Á., Fernández‐Torres, R., Pérez-Bernal, J. L., & Mochón, M. C. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.09.018 · Cited by 153
Farajzadeh, M. A., Bahram, M., Mehr, B. G., & Jönsson, J. Å. (2008) · Talanta · doi:10.1016/j.talanta.2007.12.035 · Cited by 146
Kubáň, P., Strieglerová, L., Gebauer, P., & Boček, P. (2011) · Electrophoresis · doi:10.1002/elps.201000462 · Cited by 156
Modern Methods of Sample Preparation for GC Analysis
de Koning, S., Janssen, H., & Brinkman, U. A. T. (2009) · Chromatographia · doi:10.1365/s10337-008-0937-3 · Cited by 182
Shariati, S., Yamini, Y., & Bahramifar, N. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(03)00709-8 · Cited by 143
Lambropoulou, D. A., Konstantinou, I., & Albanis, T. A. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.02.094 · Cited by 161
López-Darias, J., Germán-Hernández, M., Pino, V., & Afonso, A. M. (2010) · Talanta · doi:10.1016/j.talanta.2009.09.057 · Cited by 142
Deep eutectic solvent-based dispersive liquid-liquid microextraction
Farajzadeh, M. A., Afshar Mogaddam, M. R., & Aghanassab, M. (2016) · Analytical Methods · doi:10.1039/c5ay03189c · Cited by 141
Hou, L., & Lee, H. K. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01152-4 · Cited by 152
Solid phase microextraction as a tool for trace element speciation
Mester, Z., & Sturgeon, R. E. (2005) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2005.06.002 · Cited by 140
Bidabadi, M. S., Dadfarnia, S., & Shabani, A. M. H. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.11.052 · Cited by 140
Pena-Pereira, F., Bendicho, C., Pavlović, D. M., Martín-Esteban, A., Díaz-Álvarez, M., Pan, Y., Cooper, J., Yang, Z., Safarik, I., Pospiskova, K., et al. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.11.040 · Cited by 133
Green miniaturized technologies in analytical and bioanalytical chemistry
Agrawal, A., Keçili, R., Ghorbani‐Bidkorbeh, F., & Hussain, C. M. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116383 · Cited by 154
Zhang, Y., & Lee, H. K. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.12.017 · Cited by 139
Analytical Applications of Hollow Fiber Liquid Phase Microextraction (HF-LPME): A Review
Bello-López, M. Á., Ramos-Payán, M., Ocaña-González, J. A., Fernández-Torres, R., & Callejón-Mochón, M. (2012) · Analytical Letters · doi:10.1080/00032719.2012.655676 · Cited by 133
Fakhari, A. R., Salehi, P., Heydari, R., Ebrahimi, S. N., & Haddad, P. R. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.08.054 · Cited by 136
Manzoori, J. L., Amjadi, M., & Abulhassani, J. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.04.029 · Cited by 141
Emerging Extraction Strategies in Analytical Chemistry
Hansen, F. A., & Pedersen‐Bjergaard, S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04677 · Cited by 144
Current developments of bioanalytical sample preparation techniques in pharmaceuticals
Ingle, R. G., Zeng, S., Jiang, H., & Fang, W. (2022) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2022.03.001 · Cited by 144
“HS-SDME is identical to DI-SDME except that a microdrop of a higher boiling point extracting solvent is revealed to the sample headspace.”
BackgroundInfluentialRamos‐Payán, M., Bello‐López, M. Á., Fernández‐Torres, R., Mochón, M. C., & Gómez‐Ariza, J. L. (2010) · Talanta · doi:10.1016/j.talanta.2010.05.022 · Cited by 130
Zhao, E., Han, L., Jiang, S., Wang, Q., & Zhou, Z. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.011 · Cited by 131
Sample preconcentration in microfluidic devices
Lin, C.-C., Hsu, J., & Lee, G. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0661-9 · Cited by 145
“1 (Jeannot and Cantwell 1996):”
Rovina, K., Siddiquee, S., & Shaarani, S. M. (2017) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2017.1287558 · Cited by 134
López-Blanco, M. C., Blanco-Cid, S., Cancho-Grande, B., & Simal‐Gándara, J. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01873-3 · Cited by 129
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Es’haghi, Z., Golsefidi, M. A., Saify, A., Tanha, A. A., Rezaeifar, Z., & Alian-Nezhadi, Z. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.02.054 · Cited by 130
Martendal, E., Budziak, D., & Carasek, E. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.02.079 · Cited by 131
Santana, C. M., Sosa‐Ferrera, Z., Torres-Padrón, M. E., & Santana‐Rodríguez, J. J. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.01.011 · Cited by 146
Strieglerová, L., Kubáň, P., & Boček, P. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.011 · Cited by 135
Saraji, M., & Bakhshi, M. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.08.063 · Cited by 126
Farajzadeh, M. A., Bahram, M., Zorita, S., & Mehr, B. G. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.05.041 · Cited by 126
Basheer, C., Lee, J., Pedersen‐Bjergaard, S., Rasmussen, K. E., & Lee, H. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.04.066 · Cited by 129
Lee, J., Khalilian, F., Bagheri, H., & Lee, H. K. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.037 · Cited by 124
A review of sample preparation methods for the pesticide residue analysis in foods
Zhang, L., Liu, S., Cui, X., Pan, C., Zhang, A., & Chen, F. (2012) · Open Chemistry · doi:10.2478/s11532-012-0034-1 · Cited by 156
Analytical Microextraction: Current Status and Future Trends
Pawliszyn, J., & Pedersen-Bjergaard, S. (2006) · Journal of Chromatographic Science · doi:10.1093/chromsci/44.6.291 · Cited by 123
FARAHANI, H., GANJALI, M., DINARVAND, R., & NOROUZI, P. (2008) · Talanta · doi:10.1016/j.talanta.2008.03.002 · Cited by 123
Lili, L., Xu, H., Song, D., Cui, Y., Hu, S., & Zhang, G. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.081 · Cited by 123
Khatibi, S. A., Hamidi, S., & Siahi-Shadbad, M. R. (2020) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2020.1798211 · Cited by 129
“Single drop microextraction (SDME) is the first LLME technique developed in 1996.([61]) In SDME, a small volume Table 1.”
MethodAguilera‐Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.06.010 · Cited by 126
Deng, C., Yao, N., Wang, B., & Zhang, X. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.023 · Cited by 122
Vortex-assisted liquid-liquid microextraction revisited
Psillakis, E. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.007 · Cited by 120
Surfactant roles in modern sample preparation techniques: A review
Moradi, M., & Yamini, Y. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200368 · Cited by 120
Aufartová, J., Santana, C. M., Sosa‐Ferrera, Z., Santana‐Rodríguez, J. J., Nováková, L., & Solich, P. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.07.030 · Cited by 135
Dadfarnia, S., Salmanzadeh, A. M., & Shabani, A. M. H. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.033 · Cited by 120
Li, L., Hu, B., Xia, L., & Jiang, Z. (2006) · Talanta · doi:10.1016/j.talanta.2006.03.006 · Cited by 119
Directly suspended droplet microextraction
Lü, Y., Quan, L., Luo, G., & Youyuan, D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.02.072 · Cited by 133
Farajzadeh, M. A., Nouri, N., & Khorram, P. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.11.006 · Cited by 138
“The liquid-phase microextraction (LPME) technique was therefore developed as an alternative miniaturized sample-preparation approach in order to overcome the shortcomings of SPME [10].”
MethodLi, J., Wang, Y., Li, K.-Y., Cao, Y.-Q., Wu, S., & Wu, L. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.023 · Cited by 125
de Jager, L. S., & Andrews, A. R. J. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)01256-5 · Cited by 118
Stanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116
“Solvent microextraction into a single drop for organic analysis was suggested by Jeannot and Cantwell in 1996 [19].”
MethodKokya, T. A., & Farhadi, K. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.04.005 · Cited by 116
Alexovič, M., Horstkotte, B., Šrámková, I. H., Solich, P., & Sabó, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.10.003 · Cited by 120
Quorum sensing: Little talks for an effective bacterial coordination
Turan, N. B., Chormey, D. S., Büyükpınar, Ç., Engin, G. Ö., & Bakırdere, S. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.03.007 · Cited by 123
Ozcan, S., Tor, A., & Aydin, M. E. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.037 · Cited by 113
Yu, C., Liu, Q., Lan, L., & Hu, B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.065 · Cited by 113
Determination of trihalomethanes in water samples: A review
Pavón, J. L. P., Martín, S. H., Pinto, C. G., & Cordero, B. M. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.09.042 · Cited by 123
Fontana, A. R., Wuilloud, R. G., Martínez, L. D., & Altamirano, J. C. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.034 · Cited by 110
Liquid-phase microextraction approaches combined with atomic detection: A critical review
Pena‐Pereira, F., Lavilla, I., & Bendicho, C. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.04.050 · Cited by 121
Tseng, W.-C., Chen, P., & Huang, S. (2014) · Talanta · doi:10.1016/j.talanta.2013.11.073 · Cited by 110
Li, Y., Wei, G., Hu, J., Liu, X., Zhao, X., & Wang, X. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.03.038 · Cited by 109
Wang, X., He, Y., Li, L., Zeng, F., & Luan, T. (2013) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2013.09.069 · Cited by 110
Alexovič, M., Horstkotte, B., Solich, P., & Sabó, J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.038 · Cited by 113
Miniaturization in sample treatment for environmental analysis
Ramos, L., Ramos, J. J., & Brinkman, U. A. T. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2906-5 · Cited by 121
Bagheri, H., Saber, A., & Mousavi, S. R. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.06.062 · Cited by 107
Wu, J., Ee, K. H., & Lee, H. K. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.05.077 · Cited by 107
On-Chip Electro Membrane Extraction with Online Ultraviolet and Mass Spectrometric Detection
Petersen, N. J., Foss, S. T., Jensen, H., Hansen, S. H., Skonberg, C., Snakenborg, D., Kutter, J. P., & Pedersen-Bjergaard, S. (2011) · Analytical Chemistry · doi:10.1021/ac1027148 · Cited by 106
New Trends in Sample Preparation Techniques for Environmental Analysis
Ribeiro, C., Ribeiro, A. R., Maia, A. S., Gonçalves, V. M. F., & Tiritan, M. E. (2014) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2013.833850 · Cited by 104
“To this purpose, liquid-phase microextraction (LPME), introduced by Cantwell and coworkers (Jeannot and Cantwell, 1996), was developed by reducing the volume of solvent to just a few μL.”
MethodApplications of single-drop microextraction in analytical chemistry: A review
Kailasa, S. K., Koduru, J. R., Park, T. J., Singhal, R. K., & Wu, H. (2020) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2020.e00113 · Cited by 127
Sudhir, P.-R., Wu, H.-F., & Zhou, Z.-C. (2005) · Analytical Chemistry · doi:10.1021/ac051162m · Cited by 105
Hou, L., Shen, G., & Lee, H. K. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01827-7 · Cited by 105
de Jager, L. S., & Andrews, A. R. J. (2000) · The Analyst · doi:10.1039/b004350h · Cited by 106
Yamini, Y., Reimann, C. T., Vatanara, A., & Jönsson, J. Å. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.001 · Cited by 104
Asadollahi, T., Dadfarnia, S., & Shabani, A. M. H. (2010) · Talanta · doi:10.1016/j.talanta.2010.04.020 · Cited by 109
Electromembrane extraction–Recent trends and where to go
Pedersen‐Bjergaard, S., Huang, C., & Gjelstad, A. (2017) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2017.04.002 · Cited by 103
Automation and optimization of liquid-phase microextraction by gas chromatography
Ouyang, G., Zhao, W., & Pawliszyn, J. B. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.093 · Cited by 105
Lee, J., & Lee, H. K. (2011) · Analytical Chemistry · doi:10.1021/ac200807d · Cited by 103
Fragueiro, S., Lavilla, I., & Bendicho, C. (2005) · Talanta · doi:10.1016/j.talanta.2005.07.011 · Cited by 101
Xia, L., Hu, B., Jiang, Z., Wu, Y., Li, L., & Chen, R. (2005) · J. Anal. At. Spectrom. · doi:10.1039/b416938g · Cited by 101
Yiping, H., & Cai-yun, W. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.018 · Cited by 103
Two-phase hollow fiber liquid-phase microextraction
Esrafili, A., Baharfar, M., Tajik, M., Yamini, Y., & Ghambarian, M. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.015 · Cited by 100
Afshar Mogaddam, M. R., Farajzadeh, M. A., Mohebbi, A., & Nemati, M. (2020) · Talanta · doi:10.1016/j.talanta.2020.120986 · Cited by 100
Improved single-drop microextraction for high sensitive analysis
Ye, C., Zhou, Q., & Wang, X. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.089 · Cited by 99
Li, N., Deng, C., Yin, X., Yao, N., Shen, X., & Zhang, X. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.04.024 · Cited by 99
Recent achievements in solidified floating organic drop microextraction
Viñas, P., Campillo, N., & Andruch, V. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.005 · Cited by 99
Basheer, C., Lee, H. K., & Obbard, J. P. (2003) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.09.043 · Cited by 98
Roldán-Pijuán, M., Lucena, R., Cárdenas, S., Valcárcel, M., Kabir, A., & Furton, K. G. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.12.027 · Cited by 98
“, single-drop microextraction (SDME) [7,8], dispersive liquid-liquid microextraction (DLLME) [9] and hollow-fiber microextraction (HF-LPME) [10,11].”
Tsai, W.-H., Chuang, H.-Y., Chen, H.-H., Huang, J.-J., Chen, H.-C., Cheng, S.-H., & Huang, T.-C. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.10.008 · Cited by 98
Vázquez, M. M. P., Vázquez, P. P., Galera, M. M., & García, M. D. G. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.08.042 · Cited by 103
Li, N., Zhang, T., Chen, G., Xu, J., Ouyang, G., & Zhu, F. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116318 · Cited by 96
Tsai, W.-C., & Huang, S. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.04.086 · Cited by 102
Blomberg, L. G. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2305-4 · Cited by 95
Novel techniques for enhancing sensitivity in static headspace extraction-gas chromatography
Snow, N. H., & Bullock, G. P. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.005 · Cited by 95
Xia, L., Hu, B., Jiang, Z., Wu, Y., Chen, R., & Li, L. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b514623b · Cited by 95
Chemical reactions in liquid-phase microextraction
Xu, L., Basheer, C., & Lee, H. K. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.10.005 · Cited by 100
Recent advances of CO2-responsive materials in separations
Yang, Z., He, C., Sui, H., He, L., & Li, X. (2019) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2019.01.004 · Cited by 99
Disposable pipette extraction: A critical review of concepts, applications, and directions
Carasek, E., Morés, L., & Huelsmann, R. D. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.339383 · Cited by 94
Aubert, C. C., Baumann, S., & Arguel, H. (2005) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0510541 · Cited by 94
Applications of liquid-phase microextraction techniques in natural product analysis: A review
Yan, Y., Chen, X., Hu, S., & Bai, X. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.09.068 · Cited by 96
Liquid phase microextraction for the analysis of trace elements and their speciation
Hu, B., He, M., Chen, B., & Xia, L. (2013) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2013.05.025 · Cited by 103
Single-drop coacervative microextraction of organic compounds prior to liquid chromatography
López-Jiménez, F. J., Rubio, S., & Pérez‐Bendito, D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.002 · Cited by 101
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Affiliations
- University of Alberta (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2236-2240
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973396905
- Cited by
- 1,282
- References
- 27
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 34 · 2021: 40 · 2020: 53 · 2019: 66 · 2018: 43 · 2017: 41 · 2016: 49 · 2015: 68 · 2014: 80 · 2013: 84 · 2012: 99
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- solvent extraction, gas chromatography, solvent reduction, 4-methylacetophenone, n-octane, internal standard
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.