Solvent Microextraction into a Single Drop
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An analytical technique is described which combines solvent extraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little solvent consumption. A small drop (8 μL) of a water-immiscible organic solvent, containing an internal standard, is located at the end of a Teflon rod which is immersed in a stirred aqueous sample solution. After the solution has been stirred for a prescribed period of time, the probe is withdrawn from the aqueous solution, and the organic phase is sampled with a microsyringe and injected into the GC for quantification. The observed rate of solvent extraction is in good agreement with a convective-diffusive kinetic model. Analytically, the relative standard deviation of the method is 1.7% for a 5.00-min extraction of the analyte 4-methylacetophenone into n-octane.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various methods like agitation, stirring, vibration, shaking, and irradiation with ultrasonic waves have been applied to improve the extraction efficiency of LPME methods via increasing the mass transfer rate [83,168].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [168]
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Handbook of Solvent Extraction
Lo, T. C., Baird, M. H. I., & Hanson, C. A. (1991) · Cited by 983
Automation and optimization of solid-phase microextraction
Arthur, C. L., Killam, L. M., Buchholz, K. D., Pawliszyn, J., & Berg, J. R. (1992) · Analytical Chemistry · doi:10.1021/ac00041a034 · Cited by 620
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Membrane approach to solid-phase extractions
Hagen, D. F., Markell, C. G., Schmitt, G. A., & Blevins, D. D. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83309-7 · Cited by 235
The Kinetics of Metal Solvent Extraction
Danesi, P. R., Chiarizia, R., & Coleman, C. F. (1980) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408348008085494 · Cited by 222
Measurement of liquid-liquid interfacial kinetics
Hanna, G. J., & Noble, R. D. (1985) · Chemical Reviews · doi:10.1021/cr00070a004 · Cited by 151
Interfacial transfer studied with a rotating diffusion cell
Albery, W. J., Burke, J. F., Leffler, E. B., & Hadgraft, J. (1976) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19767201618 · Cited by 144
Some Measurements of Diffusion in Liquids.
Chang, P., & Wilke, C. R. (1955) · The Journal of Physical Chemistry · doi:10.1021/j150529a005 · Cited by 143
Transport phenomena in liquid extraction
Laddha, G. S., & Degaleesan, T. E. (1976) · Andalas University Repository (Andalas University) · Cited by 123
Research works printed but not linked: 7
- Lucy C. A., 1994, Anal. Chem., 66, 2225
- Davies, J. T.; Rideal, E. K. Interfacial Phenomena ; Academic Press: New York, 1961; Chapter 7.
- Grushka E., 1974, J. Phys. Chem., 78, 2301
- Liley, P. E.; Reid, R. C.; Buck, E. In Chemical Engineers' Handbook , 6th ed.; Perry, R. H., Green, D. W., Eds.; McGraw-Hill: New York, 1984; Chapter 3, pp 258−259.
- Laddha G. S., 1976, Transport Phenomena in Liquid Extraction
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
Cited by
Items 301–400 of 1,001
Moradi, M., & Yamini, Y. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.01.028 · Cited by 70
Current perspectives in analyte extraction strategies for tin and arsenic speciation
Dietz, C., Sanz-Landaluze, J., Sanz, E., Muñoz-Olivas, R., & Cámara, C. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.064 · Cited by 71
Hao, C., Clement, R. E., & Yang, P. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0956-6 · Cited by 72
Li, X., Xue, A., Chen, H., & Li, S. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.01.023 · Cited by 76
Kramer, K., & Andrews, A. R. J. (2001) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(01)00232-8 · Cited by 70
Huang, S.-P., & Huang, S.-D. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.073 · Cited by 73
Opportunities and shortcomings of ionic liquids in single-drop microextraction
Marcinkowski, Ł., Pena-Pereira, F., Kloskowski, A., & Namieśnik, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.03.024 · Cited by 69
Saraji, M., & Esteki, N. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2087-8 · Cited by 69
Chapter 11 Liquid—liquid extraction
Cantwell, F. F., & Losier, M. (2002) · Comprehensive analytical chemistry · doi:10.1016/s0166-526x(02)80048-4 · Cited by 69
Self-citationElectromembrane extraction of levamisole from human biological fluids
Seidi, S., Yamini, Y., Saleh, A., & Moradi, M. (2011) · Journal of Separation Science · doi:10.1002/jssc.201000735 · Cited by 69
Jalali‐Heravi, M., & Sereshti, H. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.096 · Cited by 69
Stir Membrane Extraction: A Useful Approach for Liquid Sample Pretreatment
Alcudia-León, M. C., Lucena, R., Cárdenas, S., & Valcárcel, M. (2009) · Analytical Chemistry · doi:10.1021/ac9016192 · Cited by 70
Jofré, V. P., Assof, M. V., Fanzone, M., Goicoechea, H. C., Martinez, L. D., & Silva, M. F. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.10.010 · Cited by 75
Fragueiro, S., Lavilla, I., & Bendicho, C. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2004.03.002 · Cited by 70
Cortada, C., Vidal, L., & Canals, A. (2011) · Talanta · doi:10.1016/j.talanta.2011.08.011 · Cited by 76
Bagheri, H., & Khalilian, F. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.01.036 · Cited by 68
Ramos‐Payán, M., Jensen, H. M., Petersen, N. J., Hansen, S. H., & Pedersen‐Bjergaard, S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.023 · Cited by 71
Saraji, M., & Javadian, S. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.08.108 · Cited by 68
Xiao, Q., Yu, C., Xing, J., & Hu, B. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.06.096 · Cited by 68
Fan, Z., & We, Z. (2006) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2006.05.011 · Cited by 67
Cui, S., Tan, S., Ouyang, G., & Pawliszyn, J. B. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.01.022 · Cited by 72
Determination of carbamates and organophosphorus pesticides by SDME–GC in natural water
López-Blanco, C., Gómez-Álvarez, S., Rey-Garrote, M., Cancho-Grande, B., & Simal‐Gándara, J. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0038-1 · Cited by 67
Ghambarian, M., Yamini, Y., Esrafili, A., Yazdanfar, N., & Moradi, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.07.013 · Cited by 68
Li, N., Deng, C., Yao, N., Shen, X., & Zhang, X. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.03.047 · Cited by 70
Micro-electromembrane extraction across free liquid membranes. Instrumentation and basic principles
Kubáň, P., & Boček, P. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.04.047 · Cited by 70
Cruz‐Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.11.017 · Cited by 66
Huang, S.-P., & Huang, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.09.027 · Cited by 71
Zaruba, S., Vishnikin, A. B., Škrlíková, J., & Andruch, V. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03129 · Cited by 66
Pannu, J. K., Singh, A., & Ward, O. P. (2003) · Process Biochemistry · doi:10.1016/s0032-9592(03)00254-1 · Cited by 66
Vora-adisak, N., & Varanusupakul, P. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.009 · Cited by 70
Prosen, H. (2014) · Molecules · doi:10.3390/molecules19056776 · Cited by 69
“SDME in its original form, first described by Jeannot and Cantwell in 1996 [24], is the simplest way to perform LPME.”
BackgroundMethodXu, H., Liao, Y., & Yao, J. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.022 · Cited by 65
Tegladza, I. D., Tong, Q., Chen, T., Alorku, K., Tang, S. N., Shen, W., Kong, D., Yuan, A., Liu, J., & Lee, H. K. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.122403 · Cited by 73
Dong, L., Shen, X., & Deng, C. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.03.095 · Cited by 65
Šlampová, A., Kubáň, P., & Boček, P. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.11.035 · Cited by 67
Jiang, H., Hu, B., Chen, B., & Zu, W. (2008) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2008.04.011 · Cited by 65
Yao, J., Xu, H., Lv, L., Song, D., Cui, Y., Zhang, T., & Feng, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.007 · Cited by 64
Selective electromembrane extraction at low voltages based on analyte polarity and charge
Domínguez, N. C., Gjelstad, A., Nadal, A. M., Jensen, H. M., Petersen, N. J., Hansen, S. H., Rasmussen, K. E., & Pedersen‐Bjergaard, S. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.05.092 · Cited by 64
Abdelhamid, H. N., Bhaisare, M. L., & Wu, H. (2013) · Talanta · doi:10.1016/j.talanta.2013.11.078 · Cited by 64
López‐García, I., Rivas, R. E., & Hernández‐Córdoba, M. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.07.015 · Cited by 68
Zhao, E., Shan, W., Jiang, S., Liu, Y., & Zhou, Z. (2006) · Microchemical Journal · doi:10.1016/j.microc.2006.03.008 · Cited by 64
Andruch, V., Balogh, I. S., Kocúrová, L., & Šandrejová, J. (2012) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c2ja30175j · Cited by 71
Electromembrane extraction (EME): Fundamentals and applications
Martins, R. O., de Araújo, G. L., Simas, R. C., & Chaves, A. R. (2023) · Talanta Open · doi:10.1016/j.talo.2023.100200 · Cited by 63
Miró, M., & Hansen, E. H. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.03.019 · Cited by 65
Chung, R., Leong, M., & Huang, S. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.02.025 · Cited by 65
Márquez-Sillero, I., Aguilera‐Herrador, E., Cárdenas, S., & Valcárcel, M. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.046 · Cited by 66
Tsai, W.-C., & Huang, S. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.057 · Cited by 68
Bazregar, M., Rajabi, M., Yamini, Y., Saffarzadeh, Z., & Asghari, A. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.11.087 · Cited by 65
Current trends and roles of surfactants for chromatographic and electrochemical sensing
Ünal, D. N., Yıldırım, S., Kurbanoğlu, S., & Uslu, B. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116418 · Cited by 62
Jiang, H., & Hu, B. (2007) · Microchimica Acta · doi:10.1007/s00604-007-0785-0 · Cited by 62
Shrivas, K. K., & Jaiswal, N. K. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.04.067 · Cited by 62
Zhang, J., Su, T., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.045 · Cited by 62
Hosseini, M. H., Rezaee, M. B., Mashayekhi, H. A., Akbarian, S., Mizani, F., & Pourjavid, M. R. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.09.099 · Cited by 68
Dynamic headspace liquid-phase microextraction of alcohols
Saraji, M. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.11.026 · Cited by 62
Esrafili, A., Yamini, Y., Ghambarian, M., & Ebrahimpour, B. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.09.003 · Cited by 64
Jia, C., Zhu, X., Chen, L., He, M., Yu, P., & Zhao, E. (2010) · Journal of Separation Science · doi:10.1002/jssc.200900581 · Cited by 62
Development and applications of single‐drop microextraction for pesticide residue analysis: A review
Pakade, Y. B., & Tewary, D. K. (2010) · Journal of Separation Science · doi:10.1002/jssc.201000331 · Cited by 62
Saraji, M., & Farajmand, B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.056 · Cited by 62
Farajzadeh, M. A., Bamorowat, M., & Mogaddam, M. R. A. (2016) · Talanta · doi:10.1016/j.talanta.2016.03.097 · Cited by 61
“LPME as a miniaturized sample preparation approach emerged during the mid–to–late 1990s [20, 21].”
BackgroundPeris-Pastor, G., Azorín, C., Grau, J., Benedé, J. L., & Chisvert, A. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117434 · Cited by 67
Ho, Y., Tsoi, Y., & Leung, K. S. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.02.043 · Cited by 66
Williams, D. B. G., George, M. J., Meyer, R., & Marjanovic, L. (2011) · Analytical Chemistry · doi:10.1021/ac201323z · Cited by 61
Newly Introduced Sample Preparation Techniques: Towards Miniaturization
Costa, R. (2014) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2013.860874 · Cited by 62
“It was first introduced by Jeannot and Cantwell (1996).”
BackgroundHuang, C., Seip, K. F., Gjelstad, A., Shen, X., & Pedersen‐Bjergaard, S. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01610 · Cited by 64
Ma, M., Kang, S., Zhao, Q., Chen, B., & Yao, S. (2005) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2005.06.023 · Cited by 61
Yazdi, A. S., Mofazzeli, F., & Es’haghi, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.04.090 · Cited by 61
Kailasa, S. K., & Wu, H. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.09.011 · Cited by 61
Biparva, P., Ehsani, M., & Hadjmohammadi, M. R. (2012) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2012.04.002 · Cited by 68
“Recently, liquid-phase microextractions (LPMEs), such as single-drop liquid-phase microextraction (SDME) (Jeannot and Cantwell, 1996) and hollow based-based liquid-phase microextraction (HF-LPME) (Pedersen-Bjergaard and Rasmussen, 1999), have emerged as new attractive alternatives for sample preparations.”
BackgroundMicroextraction techniques combined with capillary electrophoresis in bioanalysis
Köhler, I., Schappler, J., & Rudaz, S. L. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6367-y · Cited by 66
Fontana, A., Muñoz‐de‐Toro, M., & Altamirano, J. C. (2011) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf104622x · Cited by 64
Carasek, E., Merib, J., Mafra, G., & Spudeit, D. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.002 · Cited by 60
Highly sensitive procedure for determination of Cu(II) by GF AAS using single-drop microextraction
Néri, T. S., Rocha, D. P., Muñoz, R. A. A., Coelho, N. M. M., & Batista, A. D. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.04.014 · Cited by 61
He, Y., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.078 · Cited by 60
Meng, L., Wang, B., Luo, F., Shen, G., Wang, Z., & Guo, M. (2010) · Forensic Science International · doi:10.1016/j.forsciint.2010.12.003 · Cited by 59
Jermak, S., Pranaitytė, B., & Padarauskas, A. (2006) · Electrophoresis · doi:10.1002/elps.200600295 · Cited by 59
Cooling-assisted microextraction: Comparison of techniques and applications
Ghiasvand, A., Hajipour, S., & Heidari, N. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.12.008 · Cited by 62
Quantitative extraction using flowing nano-liter droplet in microfluidic system
Kumemura, M., & Korenaga, T. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.10.086 · Cited by 59
Gholivand, M. B., Rahimi‐Nasrabadi, M., & Chalabi, H. (2009) · Analytical Letters · doi:10.1080/00032710902961081 · Cited by 59
Ghambarian, M., Yamini, Y., & Esrafili, A. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.08.009 · Cited by 58
Gil, S., de Loos-Vollebregt, M. T. C., & Bendicho, C. (2008) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2008.12.002 · Cited by 58
Tajik, S., & Taher, M. A. (2011) · Microchimica Acta · doi:10.1007/s00604-011-0553-z · Cited by 58
Mass transfer in electromembrane extraction—The link between theory and experiments
Huang, C., Jensen, H. M., Seip, K. F., Gjelstad, A., & Pedersen‐Bjergaard, S. (2015) · Journal of Separation Science · doi:10.1002/jssc.201500905 · Cited by 58
Tajabadi, F., Ghambarian, M., Yamini, Y., & Yazdanfar, N. (2016) · Talanta · doi:10.1016/j.talanta.2016.07.035 · Cited by 58
Farajzadeh, M. A., Nasrollahpour, H., Mogaddam, M. R. A., & Khoshmaram, L. (2015) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-015-0736-3 · Cited by 57
Application of liquid-phase microextraction to the analysis of trihalomethanes in water
Tor, A., & Aydın, M. E. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.05.054 · Cited by 58
Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples
Vidal, L., Domini, C. E., Grané, N., Psillakis, E., & Canals, A. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.066 · Cited by 57
Chen, C.-C., Melwanki, M. B., & Huang, S. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.122 · Cited by 57
Wang, C., Li, C., Zang, X., Han, D., Liu, Z., & Wang, Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.027 · Cited by 56
Wu, L., Hu, M., Li, Z., Song, Y., Yu, C., Zhang, H., Yu, A., Ma, Q., & Wang, Z. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.07.055 · Cited by 61
“Different approaches have been developed for LPME, such as single drop microextraction (SDME) (Jeannot & Cantwell, 1996, 1997), hollow fiber–liquid phase microextraction (HF–LPME) (Pedersen-Bjergaard & Rasmussen, 1999), dispersive liquid–liquid microextraction (DLLME) (Zhou, Bai, Xie, & Xiao,…”
MethodOzcan, S. (2011) · Journal of Separation Science · doi:10.1002/jssc.201000623 · Cited by 56
Marlow, M., & Hurtubise, R. J. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.09.054 · Cited by 57
He, Y., Vargas, A., & Kang, Y.-J. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.02.064 · Cited by 56
Dispersive Liquid–Liquid Microextraction: Trends in The Analysis of Biological Samples
Zuloaga, O., Olivares, M., Navarro, P., Vallejo, A., & Prieto, A. (2015) · Bioanalysis · doi:10.4155/bio.15.141 · Cited by 59
Liquid-phase microextraction combined with graphite furnace atomic absorption spectrometry: A review
de la Calle, I., Pena‐Pereira, F., Lavilla, I., & Bendicho, C. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.046 · Cited by 58
Shahvar, A., Saraji, M., & Shamsaei, D. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.07.071 · Cited by 56
Automated online coupling of robot-assisted single drop microextraction and liquid chromatography
Medina, D. A. V., Cabal, L. F. R., Titato, G. M., Lanças, F. M., & Santos‐Neto, Á. J. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.02.036 · Cited by 58
Chormey, D. S., Zaman, B. T., Kasa, N. A., & Bakırdere, S. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115917 · Cited by 61
Fiamegos, Y. C., Nanos, C. G., & Stalikas, C. D. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.09.013 · Cited by 57
Guo, X., He, M., Chen, B., & Hu, B. (2012) · Talanta · doi:10.1016/j.talanta.2012.02.053 · Cited by 62
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Affiliations
- University of Alberta (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2236-2240
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973396905
- Cited by
- 1,282
- References
- 27
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 34 · 2021: 40 · 2020: 53 · 2019: 66 · 2018: 43 · 2017: 41 · 2016: 49 · 2015: 68 · 2014: 80 · 2013: 84 · 2012: 99
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- solvent extraction, gas chromatography, solvent reduction, 4-methylacetophenone, n-octane, internal standard
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.