Solvent Microextraction into a Single Drop
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An analytical technique is described which combines solvent extraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little solvent consumption. A small drop (8 μL) of a water-immiscible organic solvent, containing an internal standard, is located at the end of a Teflon rod which is immersed in a stirred aqueous sample solution. After the solution has been stirred for a prescribed period of time, the probe is withdrawn from the aqueous solution, and the organic phase is sampled with a microsyringe and injected into the GC for quantification. The observed rate of solvent extraction is in good agreement with a convective-diffusive kinetic model. Analytically, the relative standard deviation of the method is 1.7% for a 5.00-min extraction of the analyte 4-methylacetophenone into n-octane.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various methods like agitation, stirring, vibration, shaking, and irradiation with ultrasonic waves have been applied to improve the extraction efficiency of LPME methods via increasing the mass transfer rate [83,168].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [168]
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Handbook of Solvent Extraction
Lo, T. C., Baird, M. H. I., & Hanson, C. A. (1991) · Cited by 983
Automation and optimization of solid-phase microextraction
Arthur, C. L., Killam, L. M., Buchholz, K. D., Pawliszyn, J., & Berg, J. R. (1992) · Analytical Chemistry · doi:10.1021/ac00041a034 · Cited by 620
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Membrane approach to solid-phase extractions
Hagen, D. F., Markell, C. G., Schmitt, G. A., & Blevins, D. D. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83309-7 · Cited by 235
The Kinetics of Metal Solvent Extraction
Danesi, P. R., Chiarizia, R., & Coleman, C. F. (1980) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408348008085494 · Cited by 222
Measurement of liquid-liquid interfacial kinetics
Hanna, G. J., & Noble, R. D. (1985) · Chemical Reviews · doi:10.1021/cr00070a004 · Cited by 151
Interfacial transfer studied with a rotating diffusion cell
Albery, W. J., Burke, J. F., Leffler, E. B., & Hadgraft, J. (1976) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19767201618 · Cited by 144
Some Measurements of Diffusion in Liquids.
Chang, P., & Wilke, C. R. (1955) · The Journal of Physical Chemistry · doi:10.1021/j150529a005 · Cited by 143
Transport phenomena in liquid extraction
Laddha, G. S., & Degaleesan, T. E. (1976) · Andalas University Repository (Andalas University) · Cited by 123
Research works printed but not linked: 7
- Lucy C. A., 1994, Anal. Chem., 66, 2225
- Davies, J. T.; Rideal, E. K. Interfacial Phenomena ; Academic Press: New York, 1961; Chapter 7.
- Grushka E., 1974, J. Phys. Chem., 78, 2301
- Liley, P. E.; Reid, R. C.; Buck, E. In Chemical Engineers' Handbook , 6th ed.; Perry, R. H., Green, D. W., Eds.; McGraw-Hill: New York, 1984; Chapter 3, pp 258−259.
- Laddha G. S., 1976, Transport Phenomena in Liquid Extraction
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
Cited by
Items 401–500 of 1,001
Liquid-Phase Microextraction in Bioanalytical Sample Preparation
Lucena, R., Cruz-Vera, M., Cárdenas, S., & Valcárcel, M. (2009) · Bioanalysis · doi:10.4155/bio.09.16 · Cited by 55
Jagirani, M. S., Özalp, Ö., & Soylak, M. (2021) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2021.1874867 · Cited by 56
“in 1996 they used a single organic drop as the acceptor phase that is directly combined with the GC analysis.([215])The objects of designing this approach comprise to achieve high enrichment factor the wish to ease interferences from the sample matrices.”
MethodSolid phase analytical derivatization as a sample preparation method
Atapattu, S. N., & Rosenfeld, J. M. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.03.020 · Cited by 63
Xu, M., Liu, J., & Lu, J. (2013) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2013.803978 · Cited by 59
Hosseini, M. H., Rezaee, M. B., Akbarian, S., Mizani, F., Pourjavid, M. R., & Arabieh, M. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.10.030 · Cited by 64
Green analytical methodologies combining liquid-phase microextraction with capillary electrophoresis
Xie, H.-Y., & He, Y.-Z. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.017 · Cited by 56
Xu, X., Liang, F., Shi, J., Zhao, X., Liu, Z., Wu, L., Song, Y., Zhang, H., & Wang, Z. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.06.035 · Cited by 61
Microextraction methods for the determination of phthalate esters in liquid samples: A review
Farajzadeh, M. A., Sorouraddin, S. M., & Afshar Mogaddam, M. R. (2015) · Journal of Separation Science · doi:10.1002/jssc.201500013 · Cited by 55
Soylak, M., Khan, M., & Yilmaz, E. (2016) · Analytical Methods · doi:10.1039/c5ay02631h · Cited by 55
Huang, C., Seip, K. F., Gjelstad, A., & Pedersen‐Bjergaard, S. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.002 · Cited by 60
Šrámková, I. H., Horstkotte, B., Fikarová, K., Sklenářová, H., & Solich, P. (2018) · Talanta · doi:10.1016/j.talanta.2018.02.101 · Cited by 54
Jiang, W., Chen, X., Liu, F., You, X., & Xue, J. (2014) · Journal of Separation Science · doi:10.1002/jssc.201400695 · Cited by 55
Exhaustive extraction of peptides by electromembrane extraction
Huang, C., Gjelstad, A., & Pedersen‐Bjergaard, S. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.017 · Cited by 59
Liquid-Phase Microextraction or Electromembrane Extraction?
Wan, L., Lin, B., Zhu, R., Huang, C., Pedersen‐Bjergaard, S., & Shen, X. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00946 · Cited by 54
Identification of key odorants in complex mixtures occurring in nature
Baldovini, N., & Chaintreau, A. (2020) · Natural Product Reports · doi:10.1039/d0np00020e · Cited by 58
Martins, R. O., de Araújo, G. L., de Freitas, C. S., Silva, A. R., Simas, R. C., Vaz, B. G., & Chaves, A. R. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461949 · Cited by 59
Mohammadi, S. Z., Afzali, D., Taher, M. A., & Baghelani, Y. M. (2010) · Microchimica Acta · doi:10.1007/s00604-009-0267-7 · Cited by 58
“To overcome these problems, microextraction methods such as drop-in-drop system [16], single-drop microextraction [17, 18], homogenous liquid–liquid microextraction [19, 20], solid phase microextraction [21], and dispersive liquid–liquid microextraction (DLLME) [22, 23] have been developed.”
MethodDiffusion-Based Calibration for SPME Analysis of Aqueous Samples
Sukola, K., Koziel, J. A., Augusto, F., & Pawliszyn, J. B. (2000) · Analytical Chemistry · doi:10.1021/ac000903a · Cited by 54
Vortex-Assisted Liquid–Liquid Microextraction (VALLME): Applications
Ojeda, C. B., & Rojas, F. S. (2014) · Chromatographia · doi:10.1007/s10337-014-2669-x · Cited by 57
Meng, L., Liu, X., Wang, B., Shen, G., Wang, Z., & Guo, M. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.09.006 · Cited by 53
Yousefi, S. R., & Ahmadi, S. J. (2010) · Microchimica Acta · doi:10.1007/s00604-010-0406-1 · Cited by 53
“For these reasons, several microextraction techniques were developed such as single drop microextraction (SDME) [ 2 ], cloud point extraction (CPE) [3–6], homogeneous liquid–liquid extraction (HLLE) [7–9], dispersive liquid-liquid microextraction (DLLME) [10–14], solidified floating organic drop microextraction (SFODM…”
MethodKubáň, P., & Boček, P. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.04.024 · Cited by 53
Role of Microextraction Sampling Procedures in Forensic Toxicology
Barroso, M., Moreno, I., da Fonseca, B., Queiroz, J. A., & Gallardo, E. (2012) · Bioanalysis · doi:10.4155/bio.12.139 · Cited by 61
Zhang, H., Du, Z., Ji, Y., & Mei, M. (2013) · Talanta · doi:10.1016/j.talanta.2013.02.048 · Cited by 57
Sun, X., Zhu, F., Jia-bin, X., Lu, T., Hong, L., Tong, Y., & Ouyang, G. (2011) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2011.03.038 · Cited by 58
Li, G., Zhang, L., & Zhang, Z. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.07.081 · Cited by 53
Barahona, F., Díaz‐Álvarez, M., Turiel, E., & Martín‐Esteban, A. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.03.004 · Cited by 55
Pacheco, J. G., Valente, I. M., Gonçalves, L. M., Rodrigues, J. A., & Barros, A. A. (2010) · Journal of Separation Science · doi:10.1002/jssc.201000351 · Cited by 66
Lee, H. S. N., Basheer, C., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.030 · Cited by 52
Ramos‐Payán, M., Villar-Navarro, M., Fernández‐Torres, R., Mochón, M. C., & Bello‐López, M. Á. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6664-5 · Cited by 52
“9-fluoro-2,3dihydro-3-methyl10-(4-methyl-1piperazinyl)-7-oxo7H-pyrido[3,2,1ij][4,1,2] benzoxadiazine-6carboxylic acid”
MethodFarajzadeh, M. A., Abbaspour, M., Mogaddam, M. R. A., & Ghorbanpour, H. (2015) · Food Analytical Methods · doi:10.1007/s12161-015-0087-9 · Cited by 54
Abdulra’uf, L. B., Sirhan, A. Y., & Tan, G. H. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200427 · Cited by 54
Fakhari, A. R., Tabani, H., Behdad, H., Nojavan, S., & Taghizadeh, M. (2012) · Microchemical Journal · doi:10.1016/j.microc.2012.06.010 · Cited by 52
“In recent years, microscale extraction methods have been developed for the extraction of different substances from small volumes of biological fluids [31–38].”
BackgroundYang, S., Fang, X., Duan, L., Yang, S., Lei, Z., & Wen, X. (2015) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2015.03.129 · Cited by 52
Robles‐Molina, J., Gilbert‐López, B., García-Reyes, J. F., & Molina‐Díaz, A. (2013) · Talanta · doi:10.1016/j.talanta.2013.09.040 · Cited by 51
Liquid-phase microextraction preconcentration of impurities
Крылов, В. А., Krylov, A. V., Валерьевич, М. П., & Matkivskaya, Y. O. (2011) · Journal of Analytical Chemistry · doi:10.1134/s1061934811040101 · Cited by 53
Kawaguchi, M., Ito, R., Okanouchi, N., Saito, K., & Nakazawa, H. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.06.011 · Cited by 51
Avino, P., Notardonato, I., Perugini, L., & Russo, M. V. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.03.052 · Cited by 51
Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane
Mamat, N. A., & See, H. H. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.06.020 · Cited by 51
“These include solid phase micro extraction (SPME) [1], single drop microextraction (SDME) [2–4], liquid phase microextraction (LPME) [4–7], micro-SPE [8], thin-film microextraction (TFME) [9], and mixed-matrix membrane microextraction [10].”
MethodLiquid-phase microextraction of polycyclic aromatic hydrocarbons: A review
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Reviews in Analytical Chemistry · doi:10.1515/revac-2020-0101 · Cited by 50
Ocaña-González, J. A., Aranda‐Merino, N., Pérez-Bernal, J. L., & Ramos‐Payán, M. (2023) · Journal of Chromatography A · doi:10.1016/j.chroma.2023.463825 · Cited by 50
Li, S., Gao, P., Zhang, J., Li, Y., Peng, B., Gao, H., & Zhou, W. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200640 · Cited by 50
Arvand, M., Bozorgzadeh, E., & Shariati, S. (2013) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2013.06.006 · Cited by 50
Xu, H., Wang, S., Zhang, G., Huang, S., Song, D., Zhou, Y., & Long, G. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.02.006 · Cited by 50
Wu, J., & Lee, H. K. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.07.032 · Cited by 50
Farahani, H., Norouzi, P., Beheshti, A., Sobhi, H. R., Dinarvand, R., & Ganjali, M. R. (2009) · Talanta · doi:10.1016/j.talanta.2009.08.033 · Cited by 54
Li, Y., Jiao, Y., Guo, Y., & Yang, Y. (2013) · Analytical Methods · doi:10.1039/c3ay40586a · Cited by 54
Pedersen‐Bjergaard, S., Rasmussen, K. E., Brekke, A., Ho, T. S., & Grønhaug Halvorsen, T. (2005) · Journal of Separation Science · doi:10.1002/jssc.200401935 · Cited by 51
Classification and terminology in dispersive liquid–liquid microextraction
Šandrejová, J., Campillo, N., Viñas, P., & Andruch, V. (2016) · Microchemical Journal · doi:10.1016/j.microc.2016.03.007 · Cited by 50
Šrámková, I. H., Horstkotte, B., Sklenářová, H., Solich, P., & Kolev, S. D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.039 · Cited by 53
Electromembrane extraction with alkylated phosphites and phosphates as supported liquid membranes
Huang, C., Gjelstad, A., & Pedersen‐Bjergaard, S. (2016) · Journal of Membrane Science · doi:10.1016/j.memsci.2016.11.049 · Cited by 56
Headspace single‐drop microextraction with in‐drop derivatization for aldehyde analysis
Deng, C., Yao, N., Li, N., & Zhang, X. (2005) · Journal of Separation Science · doi:10.1002/jssc.200500085 · Cited by 50
Pesticides - Recent Trends in Pesticide Residue Assay
Soundararajan, R. P. (2012) · InTech eBooks · doi:10.5772/3329 · Cited by 53
Li, Y., Hu, J., Liu, X., Fu, L., Zhang, X., & Wang, X. (2008) · Journal of Separation Science · doi:10.1002/jssc.200800112 · Cited by 49
Liquid-phase microextraction based on solidified floating drops of organic solvents
Ghambarian, M., Yamini, Y., & Esrafili, A. (2013) · Microchimica Acta · doi:10.1007/s00604-013-0969-8 · Cited by 55
“In LLE, the equilibrium concentration of analyte in the organic phase is given by [19]”
Tor, A. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.06.081 · Cited by 49
Chen, P., Haung, W.-Y., & Huang, S. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.02.032 · Cited by 51
Zhou, Q., Pang, L., & Xiao, J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.08.017 · Cited by 53
Shrivas, K. K., & Patel, D. K. (2010) · Food Chemistry · doi:10.1016/j.foodchem.2010.02.035 · Cited by 49
New nanostructured support for carrier-mediated electromembrane extraction of high polar compounds
Román‐Hidalgo, C., Martín-Valero, M. J., Fernández‐Torres, R., Mochón, M. C., & Bello‐López, M. Á. (2016) · Talanta · doi:10.1016/j.talanta.2016.10.022 · Cited by 51
Funnelform single-drop microextraction for gas chromatography–electron-capture detection
Qian, L.-L., & He, Y.-Z. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.08.094 · Cited by 49
Analytical methods for determination of cork-taint compounds in wine
Fontana, A. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.03.012 · Cited by 51
Bazregar, M., Rajabi, M., Yamini, Y., Asghari, A., & Asl, Y. A. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.07.084 · Cited by 50
Song, X., Li, J., Liao, C., & Chen, L. (2011) · Chromatographia · doi:10.1007/s10337-011-2048-9 · Cited by 56
Miková, B., Dvorak, M. W., Ryšavá, L., Malá, Z., Gebauer, P., & Kubáň, P. (2021) · Talanta · doi:10.1016/j.talanta.2021.123068 · Cited by 49
Lin, Z., Zhang, Y., Zhao, Q., Chen, A., & Jiao, B. (2021) · Journal of Separation Science · doi:10.1002/jssc.202100590 · Cited by 47
Wei, S.-Y., Leong, M.-I., Li, Y., & Huang, S.-D. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.10.084 · Cited by 47
Zhao, R., Yuan, J.-P., Li, H., Wang, X., Jiang, T., & Lin, J. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1151-0 · Cited by 47
Hosseini, M., Heydari, R., & Alimoradi, M. (2014) · Talanta · doi:10.1016/j.talanta.2014.06.066 · Cited by 47
Melwanki, M. B., & Huang, S. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.08.083 · Cited by 49
Mehravar, A., Feizbakhsh, A., Sarafi, A. H. M., Konoz, E., & Faraji, H. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461618 · Cited by 46
Khan, W. A., Varanusupakul, P., Haq, H. U., Arain, M. B., Marchel, M., & Boczkaj, G. (2024) · Separation and Purification Technology · doi:10.1016/j.seppur.2024.130362 · Cited by 50
Azzam, K. M. A., Makahleh, A., Saad, B., & Mansor, S. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.03.055 · Cited by 49
Bedendo, G. C., & Carasek, E. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.017 · Cited by 49
Liu, W., Zhang, L., Fan, L., Lin, Z., Cai, Y., Wei, Z., & Chen, G. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.01.064 · Cited by 47
Hasheminasab, K. S., & Fakhari, A. R. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.11.061 · Cited by 52
“LPME has been accomplished either by extraction 56 into small water immiscible drops of organic solvent, hanging (single-drop microextraction) 57 [4,5] or dispersed (dispersive liquid–liquid microextraction) [6,7], or into small volumes of 58 acceptor solution inside the lumen of porous hollow fibers (hollow fiber liq…”
MethodXu, H., Lv, L., Hu, S., & Song, D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.068 · Cited by 46
de Oliveira, A. R. M., Cardoso, C. D., & Bonato, P. S. (2007) · Electrophoresis · doi:10.1002/elps.200600420 · Cited by 49
Liquid-phase microextraction: update May 2016 to December 2018
Campillo, N., Gavazov, K., Viñas, P., Hagarova, I., & Andruch, V. (2020) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2019.1604537 · Cited by 45
Fernández, P., Regenjo, M., Bermejo, A. M., Fernández, A., Lorenzo, R. A., & Carro, A. M. (2014) · Journal of Applied Toxicology · doi:10.1002/jat.3035 · Cited by 48
Farajzadeh, M. A., & Nouri, N. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.03.004 · Cited by 51
Vickackaite, V., & Pusvaskiene, E. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900360 · Cited by 45
Wu, J., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.08.006 · Cited by 45
Belinato, J. R., Dias, F. F. G., Caliman, J. D., Augusto, F., & Hantao, L. W. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.08.034 · Cited by 48
Shioji, H., Tsunoi, S., Harino, H., & Tanaka, M. (2004) · Journal of Chromatography A · doi:10.1016/s0021-9673(04)01146-x · Cited by 45
Barri, T., Bergström, S., Hussen, A., Norberg, J., & Jönsson, J. Å. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.01.097 · Cited by 45
Strategies for single-drop microextraction optimisation and validation
Romero, J., López, P., Rubio‐Terres, C., Batlle, R., & Nerín, C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.009 · Cited by 45
Zhang, Y., & Lee, H. K. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.06.065 · Cited by 46
Capillary electrophoretic determination of ammonia using headspace single-drop microextraction
Pranaitytė, B., Jermak, S., Naujalis, E., & Padarauskas, A. (2006) · Microchemical Journal · doi:10.1016/j.microc.2006.10.001 · Cited by 45
Zhang, Y., Guo, W., Yue, Z., Li, L., Zhao, F., Chen, P., Wu, W., Zhu, H. X., Yang, B., Yanyun, K., et al. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.01.026 · Cited by 44
Electromembrane extraction of peptides using deep eutectic solvents as liquid membrane
Rye, T. K., Martinovic, G., Vårdal, L., Hansen, F. A., Halvorsen, T. G., & Pedersen‐Bjergaard, S. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338717 · Cited by 47
Recent Advances in Headspace Gas Chromatography
Wang, Y., McCaffrey, J., & Norwood, D. L. (2008) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826070802129092 · Cited by 48
“The original application used an 8 µL drop of n -octane in an aqueous sample, [ 71 ] and only a fraction of this drop was analyzed subsequently by GC.”
MethodWen, X., Deng, Q., Wang, J., Yang, S., & Zhao, X. (2012) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2012.12.040 · Cited by 43
You, X., Xing, Z., Liu, F., & Zhang, X. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.03.033 · Cited by 43
Afzali, D., Mohadesi, A., Bahadori, B., & Falahnejad, M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.11.003 · Cited by 44
Chen, W., Zhong, G., Zhou, Z., Wu, P., & Hou, X. (2005) · Analytical Sciences · doi:10.2116/analsci.21.1189 · Cited by 43
Kardani, F., Daneshfar, A., & Sahraei, R. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.08.041 · Cited by 43
Šlampová, A., Šindelář, V., & Kubáň, P. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.11.010 · Cited by 43
Advances in sample preparation in chromatography for organic environmental pollutants analyses
Ali, I., Suhail, M., Alharbi, O. M. L., & Hussain, I. (2019) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2019.1579739 · Cited by 46
“Liu and Dasgupta[46] and Jeannot and Cantwell[47] introduced SDME for further reducing extraction volume.”
MethodProgress in the analytical research methods of polycyclic aromatic hydrocarbons (PAHs)
Zhang, Q., Liu, P., Li, S., Zhang, X., & Chen, M. (2020) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2020.1746668 · Cited by 47
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Affiliations
- University of Alberta (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2236-2240
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973396905
- Cited by
- 1,282
- References
- 27
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 34 · 2021: 40 · 2020: 53 · 2019: 66 · 2018: 43 · 2017: 41 · 2016: 49 · 2015: 68 · 2014: 80 · 2013: 84 · 2012: 99
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- solvent extraction, gas chromatography, solvent reduction, 4-methylacetophenone, n-octane, internal standard
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.