Solvent Microextraction into a Single Drop
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An analytical technique is described which combines solvent extraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little solvent consumption. A small drop (8 μL) of a water-immiscible organic solvent, containing an internal standard, is located at the end of a Teflon rod which is immersed in a stirred aqueous sample solution. After the solution has been stirred for a prescribed period of time, the probe is withdrawn from the aqueous solution, and the organic phase is sampled with a microsyringe and injected into the GC for quantification. The observed rate of solvent extraction is in good agreement with a convective-diffusive kinetic model. Analytically, the relative standard deviation of the method is 1.7% for a 5.00-min extraction of the analyte 4-methylacetophenone into n-octane.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various methods like agitation, stirring, vibration, shaking, and irradiation with ultrasonic waves have been applied to improve the extraction efficiency of LPME methods via increasing the mass transfer rate [83,168].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [168]
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Handbook of Solvent Extraction
Lo, T. C., Baird, M. H. I., & Hanson, C. A. (1991) · Cited by 983
Automation and optimization of solid-phase microextraction
Arthur, C. L., Killam, L. M., Buchholz, K. D., Pawliszyn, J., & Berg, J. R. (1992) · Analytical Chemistry · doi:10.1021/ac00041a034 · Cited by 620
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Membrane approach to solid-phase extractions
Hagen, D. F., Markell, C. G., Schmitt, G. A., & Blevins, D. D. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83309-7 · Cited by 235
The Kinetics of Metal Solvent Extraction
Danesi, P. R., Chiarizia, R., & Coleman, C. F. (1980) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408348008085494 · Cited by 222
Measurement of liquid-liquid interfacial kinetics
Hanna, G. J., & Noble, R. D. (1985) · Chemical Reviews · doi:10.1021/cr00070a004 · Cited by 151
Interfacial transfer studied with a rotating diffusion cell
Albery, W. J., Burke, J. F., Leffler, E. B., & Hadgraft, J. (1976) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19767201618 · Cited by 144
Some Measurements of Diffusion in Liquids.
Chang, P., & Wilke, C. R. (1955) · The Journal of Physical Chemistry · doi:10.1021/j150529a005 · Cited by 143
Transport phenomena in liquid extraction
Laddha, G. S., & Degaleesan, T. E. (1976) · Andalas University Repository (Andalas University) · Cited by 123
Research works printed but not linked: 7
- Lucy C. A., 1994, Anal. Chem., 66, 2225
- Davies, J. T.; Rideal, E. K. Interfacial Phenomena ; Academic Press: New York, 1961; Chapter 7.
- Grushka E., 1974, J. Phys. Chem., 78, 2301
- Liley, P. E.; Reid, R. C.; Buck, E. In Chemical Engineers' Handbook , 6th ed.; Perry, R. H., Green, D. W., Eds.; McGraw-Hill: New York, 1984; Chapter 3, pp 258−259.
- Laddha G. S., 1976, Transport Phenomena in Liquid Extraction
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
Cited by
Items 501–600 of 1,001
Shrivas, K. K., & Wu, H. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.10.032 · Cited by 45
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Alves, M. S., Neto, L. C. F., Scheid, C., & Merib, J. (2021) · Journal of Separation Science · doi:10.1002/jssc.202100599 · Cited by 42
Recent Advances in Unique Sample Preparation Techniques for Bioanalysis
Namera, A., & Saito, T. (2013) · Bioanalysis · doi:10.4155/bio.13.52 · Cited by 41
Chen, Y., Lü, W., Chen, X., & Teng, M. (2012) · Open Chemistry · doi:10.2478/s11532-012-0007-4 · Cited by 42
Solid drop based liquid-phase microextraction
Ganjali, M. R., Sobhi, H. R., Farahani, H., Norouzi, P., Dinarvand, R., & Kashtiaray, A. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.026 · Cited by 46
Yu, S., Xiao, Q., Zhu, B., Zhong, X., Xu, Y., Su, G., & Chen, M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.01.002 · Cited by 44
Jinadasa, B. K. K. K., Monteau, F., & Morais, S. (2020) · Food Additives & Contaminants Part A · doi:10.1080/19440049.2020.1733103 · Cited by 43
Ferrofluid-based liquid-phase microextraction
Shi, Z., Zhang, Y., & Lee, H. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.09.049 · Cited by 43
Determination of coal tar and creosote constituents in the aquatic environment
Hale, R. C., & Aneiro, K. M. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00167-2 · Cited by 42
Review: Microextraction Technique Based New Trends in Food Analysis
Jagirani, M. S., & Soylak, M. (2020) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2020.1846491 · Cited by 46
Fontana, A., Patil, S. H., Banerjee, K., & Altamirano, J. C. (2010) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf904396g · Cited by 47
Xiao, Q., & Hu, B. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.04.023 · Cited by 41
Xu, L., Gong, X. Y., Lee, H. K., & Hauser, P. C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.005 · Cited by 41
Wang, X., Luo, L., Ouyang, G., Li, L., Tam, N. F. Y., Lan, C., & Luan, T. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.011 · Cited by 44
Amini, R., Rouhollahi, A., Adibi, M., & Mehdinia, A. (2010) · Talanta · doi:10.1016/j.talanta.2010.10.043 · Cited by 41
The extraction of uranium using graphene aerogel loading organic solution
Chen, M., Li, Z., Li, J., Li, J., Li, Q., & Zhang, L. (2017) · Talanta · doi:10.1016/j.talanta.2017.01.070 · Cited by 43
Nia, N. N., & Hadjmohammadi, M. R. (2019) · Analytical Methods · doi:10.1039/c9ay01704f · Cited by 41
Zhang, Z., Zhang, C., Su, X., Ma, M., Chen, B., & Yao, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.016 · Cited by 46
Heydari, R., & Zarabi, S. (2014) · Anal. Methods · doi:10.1039/c4ay01723d · Cited by 40
Developments in the Determination of Trace Elements by Atomic Spectroscopic Techniques
Srogi, K. (2008) · Analytical Letters · doi:10.1080/00032710801934445 · Cited by 41
“Jeannot and Cantwell (1996) first reported a novel single‐drop microextraction (SDME) technique, where a small drop of a water‐immiscible organic solvent was held at the end of a Teflon rod immersed in a stirred aqueous sample solution.”
A novel approach to automation of dynamic hollow fiber liquid‐phase microextraction
Esrafili, A., Yamini, Y., Ghambarian, M., Moradi, M., & Seidi, S. (2011) · Journal of Separation Science · doi:10.1002/jssc.201000913 · Cited by 41
Deng, C., Yang, X., & ZHANG, X. (2005) · Talanta · doi:10.1016/j.talanta.2005.04.040 · Cited by 41
Kokosa, J. M., & Przyjazny, A. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01686-2 · Cited by 41
Bioanalytical Applications of Microextraction Techniques: A Review of Reviews
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Chromatographia · doi:10.1007/s10337-020-03884-1 · Cited by 40
Shah, F., Soylak, M., Kazi, T. G., & Afridi, H. I. (2012) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c2ja30243h · Cited by 40
Fernandes, V. C., Subramanian, V., Mateus, N. F. D. C. B., Domingues, V. F., & Delerue-Matos, C. M. (2012) · Microchimica Acta · doi:10.1007/s00604-012-0810-9 · Cited by 41
“Single-drop microextration (SDME), developed by Jeannot and Cantwell [25] and optimized by Liu and Dasgupta [26] provides an alternative technique, which integrates sampling, extracting and concentrating into a single step [5, 27, 28].”
MethodChen, B., Wu, Y., Guo, X., He, M., & Hu, B. (2014) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c4ja00312h · Cited by 44
Yang, F., Liu, R., Tan, Z., Wen, X., Zheng, C., & Lv, Y. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.07.059 · Cited by 41
“[20–25], miniaturized preconcentration methods based on singledrop microextraction (SDME) have recently aroused a great interest, due to the favorable characteristics of simplicity, cheapness, rapidity, minimized organic reagents consumption [26–29].”
BackgroundSobhi, H. R., Kashtiaray, A., Farahani, H., Javaheri, M., & Ganjali, M. R. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.09.161 · Cited by 40
Poojary, H., Selvamuthukumar, K., Parveen, R., Illanad, G. H., Mandal, D., Koo, S., & Ghosh, C. (2025) · Green Chemistry Letters and Reviews · doi:10.1080/17518253.2025.2486135 · Cited by 42
“The major drawback of this approach was the instability and incompatibility due to the presence of dirty samples (142,143).”
Farhadi, K., Matin, A. A., & Hashemi, P. (2008) · Chromatographia · doi:10.1365/s10337-008-0815-z · Cited by 44
Sobhi, H. R., Yamini, Y., Esrafili, A., & Adib, M. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.07.029 · Cited by 39
Wu, L., Hu, M., Li, Z., Song, Y., Zhang, H., Yu, A., Ma, Q., & Wang, Z. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.06.062 · Cited by 40
Naeemullah, Kazi, T. G., Tüzen, M., Shah, F., Afridi, H. I., & Çıtak, D. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.12.034 · Cited by 40
Fontana, A., & Altamirano, J. C. (2010) · Talanta · doi:10.1016/j.talanta.2010.02.065 · Cited by 42
Zhao, Q., Wei, F., Xiao, N., Yu, Q., Yuan, B., & Feng, Y. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.03.090 · Cited by 38
Nayebi, R., & Shemirani, F. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116232 · Cited by 38
Farajzadeh, M. A., Nouri, N., & Nabil, A. A. A. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.09.035 · Cited by 38
Xu, H., Song, D., Cui, Y., Hu, S., Yu, Q.-W., & Feng, Y.-Q. (2009) · Chromatographia · doi:10.1365/s10337-009-1208-7 · Cited by 37
Stanisz, E., Werner, J., & Matusiewicz, H. (2014) · Microchemical Journal · doi:10.1016/j.microc.2014.01.007 · Cited by 37
Shah, F., Yılmaz, E., Kazi, T. G., Afridi, H. I., & Soylak, M. (2012) · Analytical Methods · doi:10.1039/c2ay25773d · Cited by 39
Emulsion-based liquid-phase microextraction: a review
Moradi, M., Yamini, Y., & Ebrahimpour, B. (2013) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-013-0376-4 · Cited by 38
Kokya, T. A., Farhadi, K., & Kalhori, A. (2011) · Food Analytical Methods · doi:10.1007/s12161-011-9245-x · Cited by 38
“Liquid–liquid microextraction (Jiang et al. 2005; Jeannot and Cantwell 1996) and singledrop microextraction (Jeannot and Cantwell 1997; Ahmadi et al.”
BackgroundSaraji, M., Jafari, M. T., & Mossaddegh, M. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.04.034 · Cited by 37
Gayathri, S., Radhika, S., Suman, T. Y., & Aranganathan, L. (2018) · Biomass Conversion and Biorefinery · doi:10.1007/s13399-018-0331-9 · Cited by 40
“microextraction was first introduced by Jeannot and Cantwell [16], and it is based on analyte partition between a drop of organic solvent (extraction phase) and the aqueous sample bulk.”
MethodÇıtak, D., & Sabancı, D. (2021) · Journal of Food Measurement & Characterization · doi:10.1007/s11694-020-00761-1 · Cited by 37
Pena‐Pereira, F., Cabaleiro, N., de la Calle, I., Costas‐Rodríguez, M., Gil, S., Lavilla, I., & Bendicho, C. (2011) · Talanta · doi:10.1016/j.talanta.2011.05.032 · Cited by 37
Zhou, J., Liu, R., Song, G., & Zhang, M. (2009) · Analytical Letters · doi:10.1080/00032710903060677 · Cited by 41
Loh, S. H., Sanagi, M. M., Ibrahim, W. A. W., & Hasan, M. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.06.010 · Cited by 37
Kawaguchi, M., Ito, R., Honda, H., Koganei, Y., Okanouchi, N., Saito, K., Seto, Y., & Nakazawa, H. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.12.021 · Cited by 40
Generic Liquid Membranes for Electromembrane Extraction of Bases with Low or Moderate Hydrophilicity
Zhou, C., Dowlatshah, S., Hay, A. O., Schüller, M., Pedersen‐Bjergaard, S., & Hansen, F. A. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c01052 · Cited by 36
Hollow fibre liquid-phase microextraction of parabens from environmental waters
Díaz‐Álvarez, M., Turiel, E., & Martín‐Esteban, A. (2012) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2012.708749 · Cited by 42
Li, P., & Hu, B. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.05.058 · Cited by 37
Vortex solvent bar microextraction for phthalate esters from aqueous matrices
Huang, G., Li, H., Zhang, B., Ma, Y., & Lin, J. (2012) · Talanta · doi:10.1016/j.talanta.2012.08.009 · Cited by 37
Chen, P., Tseng, Y.-H., Chuang, Y.-L., & Chen, J.-H. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.03.067 · Cited by 36
Wang, K.-D., Chen, P., & Huang, S. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7044-5 · Cited by 36
Preconcentration in micro-electromembrane extraction across free liquid membranes
Kubáň, P., & Boček, P. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.07.037 · Cited by 36
Zhou, Q., Pang, L., & Xiao, J. (2011) · Microchimica Acta · doi:10.1007/s00604-011-0587-2 · Cited by 37
“SDME was developed by Jeannot and Cantwell [22] for the determination of environmental pollutants firstly, and the results confirmed that it was an ingenious sample pretreatment method with advantage of simplicity, high enrichment factors and less consumption of organic solvents.”
Dispersive Liquid–Liquid Microextraction
Assadi, Y., Farajzadeh, M. A., & Bidari, A. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00051-x · Cited by 42
Electromembrane extraction—looking into the future
Pedersen‐Bjergaard, S. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1512-x · Cited by 39
Wu, H., & Lin, C. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2612 · Cited by 36
Yazdi, A. S., Assadi, H., & Ibrahim, W. A. W. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie202856h · Cited by 36
Deng, J., Wang, W., Yang, Y., Wang, X., Chen, B., Yao, Z., & Luan, T. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.08.037 · Cited by 37
Pu, X., Chen, B., & Hu, B. (2009) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2009.06.001 · Cited by 38
Fang, H., Zeng, Z., Liu, L., & Pang, D. (2006) · Analytical Chemistry · doi:10.1021/ac0516537 · Cited by 36
Keller, B. O., & Li, L. (2001) · Analytical Chemistry · doi:10.1021/ac001323g · Cited by 36
The role of microextraction techniques in occupational exposure assessment. A review
Jalili, V., Barkhordari, A., & Norouzian Baghani, A. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.104086 · Cited by 35
Choi, K., Jin, Y. G., & Chung, D. S. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.047 · Cited by 35
Chia, K., & Huang, S. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2282 · Cited by 37
Gao, W., Chen, G., Chen, T., Zhang, X., Chen, Y., & Hu, Z. (2011) · Talanta · doi:10.1016/j.talanta.2010.11.066 · Cited by 35
Lin, Z., Zhang, Y., Zhao, Q., Cui, Y., Chen, A., & Jiao, B. (2021) · Microchemical Journal · doi:10.1016/j.microc.2021.106973 · Cited by 36
Díaz-Álvarez, M., Turiel, E., & Martín-Esteban, A. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.109347 · Cited by 35
Mosavian, M. T. H., Es’haghi, Z., Razavi, N., & Banihashemi, S. (2012) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2012.07.007 · Cited by 36
“In the SDME technique, a microdrop of an organic solvent is immersed in a stirred aqueous sample solution [13–14].”
Luciano, R. M., Bedendo, G. C., Carletto, J. S., & Carasek, E. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.12.070 · Cited by 35
“Among these alternative techniques, iquid-phase microextraction (LPME) introduced firstly by Liu and asgupta [1] and by Jeannot and Cantwell [2] is becoming a widely ccepted and applied sample preparation technique, as it is a simle, relatively fast extraction and preconcentration procedure and s particularly attracti…”
MethodChamsaz, M., Arbab-Zavar, M. H., & Akhondzadeh, J. (2008) · Analytical Sciences · doi:10.2116/analsci.24.799 · Cited by 35
Zhao, R., Chu, S., & Xu, X. (2004) · Analytical Sciences · doi:10.2116/analsci.20.663 · Cited by 35
Modern automated microextraction procedures for bioanalytical, environmental, and food analyses
Sartore, D. M., Medina, D. A. V., Bocelli, M. D., Jordan‐Sinisterra, M., Santos‐Neto, Á. J., & Lanças, F. M. (2023) · Journal of Separation Science · doi:10.1002/jssc.202300215 · Cited by 37
Es’haghi, Z., Mohtaji, M., Hasanzade-Meidani, M., & Masrournia, M. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.02.015 · Cited by 36
Williams, D. B. G., George, M. J., & Marjanović, L. (2014) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf502411t · Cited by 34
A green solvent holder in electro-mediated microextraction for the extraction of phenols in water
Chong, Y. T., Ariffin, M. M., Tahir, N. M., & Loh, S. H. (2017) · Talanta · doi:10.1016/j.talanta.2017.08.068 · Cited by 36
Lemos, V. A., Oliveira, R. V., dos Santos, W. N. L., Menezes, R. M., Santos, L. B., & Ferreira, S. L. C. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.031 · Cited by 36
Sun, W., Wei, Y., Guo, X., Wu, Q., Di, X., & Fang, Q. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00007 · Cited by 35
Kubáň, P., & Boček, P. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.065 · Cited by 36
Sanagi, M. M., Loh, S. H., Ibrahim, W. A. W., & Hasan, M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.09.007 · Cited by 35
Ells, B., Wang, Y., & Cantwell, F. F. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)01070-x · Cited by 34
Self-citationHigh-Throughput Liquid–Liquid Extractions with Nanoliter Volumes
Wells, S. S., & Kennedy, R. T. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04915 · Cited by 36
Watson, S. B., Brownlee, B. G., Satchwill, T., & McCauley, E. P. (1999) · Water Science & Technology · doi:10.1016/s0273-1223(99)00565-x · Cited by 34
Farhadi, K., Farajzadeh, M. A., & Matin, A. A. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900050 · Cited by 33
Yu, Y., Chen, B., Shen, C., Cai, Y., Xie, M., We, Z., Chen, Y., Li, Y., & Duan, G. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.06.009 · Cited by 33
Heydari, R. (2012) · Analytical Letters · doi:10.1080/00032719.2012.677982 · Cited by 33
Ling, D.-S., Xie, H., He, Y.-Z., Gan, W., & Gao, Y. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.10.041 · Cited by 33
Sun, S., Cheng, Z., Xie, J., Zhang, J., Liao, Y., Wang, H., & Guo, Y. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1884 · Cited by 33
Headspace Single Drop Microextraction Using Micellar Ionic Liquid Extraction Solvents
Yao, C., Twu, P., & Anderson, J. L. (2010) · Chromatographia · doi:10.1365/s10337-010-1675-x · Cited by 35
Kailasa, S. K., Mehta, V. N., & Wu, H. (2014) · RSC Advances · doi:10.1039/c3ra47347c · Cited by 33
Manousi, N., Raber, G., & Papadoyannis, I. N. (2017) · Separations · doi:10.3390/separations4020018 · Cited by 32
“Liquid Phase Microextraction (LPME) is a miniaturized form of liquid-liquid extraction, which was firstly introduced at 1990s, when Dasgupta [19] and Jeannot and Cantwell [20] suggested almost at the same time the use of extraction solvents in the low microliter range.”
BackgroundWang, Y., Yang, L. C., Xing, R., Wang, R., Chen, X., & Hu, S. (2022) · Journal of Chromatography A · doi:10.1016/j.chroma.2022.463712 · Cited by 32
Li, Y., Zhang, T., & Liang, P. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.12.033 · Cited by 33
Carasek, E., Bernardi, G., do Carmo, S. N., & Vieira, C. M. S. (2019) · Separations · doi:10.3390/separations6030035 · Cited by 33
Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop
WANG, Y.-Y., ZHAO, G.-Y., CHANG, Q.-Y., ZANG, X.-H., WANG, C., & WANG, Z. (2010) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(09)60073-6 · Cited by 33
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Affiliations
- University of Alberta (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2236-2240
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973396905
- Cited by
- 1,282
- References
- 27
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 34 · 2021: 40 · 2020: 53 · 2019: 66 · 2018: 43 · 2017: 41 · 2016: 49 · 2015: 68 · 2014: 80 · 2013: 84 · 2012: 99
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- solvent extraction, gas chromatography, solvent reduction, 4-methylacetophenone, n-octane, internal standard
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.