Solvent Microextraction into a Single Drop
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An analytical technique is described which combines solvent extraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little solvent consumption. A small drop (8 μL) of a water-immiscible organic solvent, containing an internal standard, is located at the end of a Teflon rod which is immersed in a stirred aqueous sample solution. After the solution has been stirred for a prescribed period of time, the probe is withdrawn from the aqueous solution, and the organic phase is sampled with a microsyringe and injected into the GC for quantification. The observed rate of solvent extraction is in good agreement with a convective-diffusive kinetic model. Analytically, the relative standard deviation of the method is 1.7% for a 5.00-min extraction of the analyte 4-methylacetophenone into n-octane.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various methods like agitation, stirring, vibration, shaking, and irradiation with ultrasonic waves have been applied to improve the extraction efficiency of LPME methods via increasing the mass transfer rate [83,168].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [168]
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Handbook of Solvent Extraction
Lo, T. C., Baird, M. H. I., & Hanson, C. A. (1991) · Cited by 983
Automation and optimization of solid-phase microextraction
Arthur, C. L., Killam, L. M., Buchholz, K. D., Pawliszyn, J., & Berg, J. R. (1992) · Analytical Chemistry · doi:10.1021/ac00041a034 · Cited by 620
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Membrane approach to solid-phase extractions
Hagen, D. F., Markell, C. G., Schmitt, G. A., & Blevins, D. D. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83309-7 · Cited by 235
The Kinetics of Metal Solvent Extraction
Danesi, P. R., Chiarizia, R., & Coleman, C. F. (1980) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408348008085494 · Cited by 222
Measurement of liquid-liquid interfacial kinetics
Hanna, G. J., & Noble, R. D. (1985) · Chemical Reviews · doi:10.1021/cr00070a004 · Cited by 151
Interfacial transfer studied with a rotating diffusion cell
Albery, W. J., Burke, J. F., Leffler, E. B., & Hadgraft, J. (1976) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19767201618 · Cited by 144
Some Measurements of Diffusion in Liquids.
Chang, P., & Wilke, C. R. (1955) · The Journal of Physical Chemistry · doi:10.1021/j150529a005 · Cited by 143
Transport phenomena in liquid extraction
Laddha, G. S., & Degaleesan, T. E. (1976) · Andalas University Repository (Andalas University) · Cited by 123
Research works printed but not linked: 7
- Lucy C. A., 1994, Anal. Chem., 66, 2225
- Davies, J. T.; Rideal, E. K. Interfacial Phenomena ; Academic Press: New York, 1961; Chapter 7.
- Grushka E., 1974, J. Phys. Chem., 78, 2301
- Liley, P. E.; Reid, R. C.; Buck, E. In Chemical Engineers' Handbook , 6th ed.; Perry, R. H., Green, D. W., Eds.; McGraw-Hill: New York, 1984; Chapter 3, pp 258−259.
- Laddha G. S., 1976, Transport Phenomena in Liquid Extraction
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
Cited by
Items 201–300 of 1,001
Kinetic aspects of hollow fiber liquid-phase microextraction and electromembrane extraction
Gjelstad, A., Jensen, H. M., Rasmussen, K. E., & Pedersen‐Bjergaard, S. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.12.039 · Cited by 100
Kinetic Calibration for Automated Hollow Fiber-Protected Liquid-Phase Microextraction
Ouyang, G., & Pawliszyn, J. (2006) · Analytical Chemistry · doi:10.1021/ac060669+ · Cited by 94
Viñas, P., Martínez-Castillo, N., Campillo, N., & Hernández‐Córdoba, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.12.026 · Cited by 92
Horstkotte, B., Suárez, R., Solich, P., & Cerdà, V. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.05.049 · Cited by 100
Ma, J. J., Du, X., Zhang, J. W., Li, J. C., & Wang, L. Z. (2009) · Talanta · doi:10.1016/j.talanta.2009.08.029 · Cited by 92
Andruch, V., Kocúrová, L., Balogh, I. S., & Škrlíková, J. (2011) · Microchemical Journal · doi:10.1016/j.microc.2011.10.006 · Cited by 102
Xia, L., Wu, Y., & Hu, B. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1216 · Cited by 93
Hansen, F. A., Øiestad, E. L., & Pedersen‐Bjergaard, S. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113446 · Cited by 97
Ramos‐Payán, M., Bello‐López, M. Á., Fernández‐Torres, R., González, J. A. O., & Mochón, M. C. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.01.037 · Cited by 102
Ramos‐Payán, M., Bello‐López, M. Á., Fernández‐Torres, R., Villar-Navarro, M., & Mochón, M. C. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.12.006 · Cited by 97
Deng, C., Yao, N., Wang, A., & Zhang, X. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.12.044 · Cited by 91
Mohamadi, M., & Mostafavi, A. (2010) · Talanta · doi:10.1016/j.talanta.2009.12.004 · Cited by 91
Headspace mode of liquid phase microextraction: A review
Afshar Mogaddam, M. R., Mohebbi, A., Pazhohan, A., Khodadadeian, F., & Farajzadeh, M. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.10.021 · Cited by 89
Arpa, Ç., & Durukan, İ. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.04.012 · Cited by 94
Ranjbari, E., Biparva, P., & Hadjmohammadi, M. R. (2011) · Talanta · doi:10.1016/j.talanta.2011.11.079 · Cited by 90
Yazdi, A. S., Amiri, A., & Es’haghi, Z. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.069 · Cited by 92
Wijethunga, P. A. L., Nanayakkara, Y. S., Kunchala, P., Armstrong, D. W., & Moon, H. (2011) · Analytical Chemistry · doi:10.1021/ac102716s · Cited by 92
Farajzadeh, M. A., Djozan, D., & Khorram, P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.11.030 · Cited by 89
Microextraction approaches for bioanalytical applications: An overview
Abdel‐Rehim, M., Pedersen‐Bjergaard, S., Abdel‐Rehim, A., Lucena, R., Moein, M. M., Cárdenas, S., & Miró, M. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.460790 · Cited by 95
Yang, C., Wang, J., & Li, D. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.07.069 · Cited by 103
Zhu, L. Y., Tay, C. B., & Lee, H. K. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00547-2 · Cited by 89
Zhang, Y., & Lee, H. K. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.06.019 · Cited by 93
Deng, C., Liu, N., Gao, M., & Zhang, X. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.081 · Cited by 88
Solvent microextraction of chlorinated pesticides
de Jager, L. S., & Andrews, A. R. J. (1999) · Chromatographia · doi:10.1007/bf02497313 · Cited by 88
Manzoori, J. L., Amjadi, M., & Abulhassani, J. (2008) · Talanta · doi:10.1016/j.talanta.2008.09.045 · Cited by 88
Cortada, C., Vidal, L., Tejada, S., Romo, A., & Canals, A. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.01.062 · Cited by 87
Chen, X., Wu, X., Luan, T., Jiang, R., & Ouyang, G. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461961 · Cited by 96
Es’haghi, Z., Ebrahimi, M., & Hosseini, M. S. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.03.043 · Cited by 86
Hu, X., Wu, J.-H., & Feng, Y. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.09.013 · Cited by 89
Carasek, E., Morés, L., & Merib, J. (2018) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2018.e00060 · Cited by 85
Microextraction sample preparation techniques in forensic analytical toxicology
He, Y., & Concheiro, M. (2018) · Biomedical Chromatography · doi:10.1002/bmc.4444 · Cited by 85
Miniaturization of Liquid-Liquid extraction; the barriers and the enablers
Kannouma, R. E., Hammad, M. A., Kamal, A. H., & Mansour, F. R. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.107863 · Cited by 90
Sereshti, H., Karimi, M., & Samadi, S. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.081 · Cited by 85
Kawaguchi, M., Ito, R., Endo, N., Okanouchi, N., Sakui, N., Saito, K., & Nakazawa, H. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.01.061 · Cited by 87
Gjelstad, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.01.007 · Cited by 95
Microextraction Techniques with Deep Eutectic Solvents
Plastiras, O.-E., Andreasidou, E., & Samanidou, V. (2020) · Molecules · doi:10.3390/molecules25246026 · Cited by 84
“In addition, a comparison of the introduced technique with SPME showed that they were comparable in terms of precision, sensitivity, and extraction time, although SPME was considered less complicated [93].”
MethodIonic liquids in microextraction techniques
Vičkačkaitė, V., & Padarauskas, A. (2012) · Open Chemistry · doi:10.2478/s11532-012-0023-4 · Cited by 84
Hu, Y., Wang, Y., Hu, Y., & Li, G. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.063 · Cited by 92
Anthemidis, A. N., & Adam, I. S. I. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.10.078 · Cited by 84
Behbahani, M., Najafi, F., Bagheri, S., Bojdi, M. K., Salarian, M., & Bagheri, A. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.07.088 · Cited by 91
Organic solvents in electromembrane extraction: recent insights
Huang, C., Gjelstad, A., & Pedersen‐Bjergaard, S. (2016) · Reviews in Analytical Chemistry · doi:10.1515/revac-2016-0008 · Cited by 95
Chamsaz, M., Arbab-Zavar, M. H., & Nazari, S. (2003) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b303169a · Cited by 83
Zacharis, C. K., Tzanavaras, P. D., Roubos, K., & DHIMA, K. V. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.07.065 · Cited by 89
Vázquez, M. M. P., Vázquez, P. P., Galera, M. M., García, M. D. G., & Uclés, A. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.03.066 · Cited by 86
Farajzadeh, M. A., Afshar Mogaddam, M. R., & Feriduni, B. (2016) · RSC Advances · doi:10.1039/c6ra04103e · Cited by 82
Automated Dispersive Liquid–Liquid Microextraction–Gas Chromatography–Mass Spectrometry
Guo, L., & Lee, H. K. (2014) · Analytical Chemistry · doi:10.1021/ac404088c · Cited by 82
Sample treatments based on dispersive (micro)extraction
Cruz-Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2011) · Analytical Methods · doi:10.1039/c1ay05201b · Cited by 82
Bagheri, H., & Naderi, M. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.09.128 · Cited by 82
Xia, L., Hu, B., & Wu, Y. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.089 · Cited by 81
Kinetic Calibration for Automated Headspace Liquid-Phase Microextraction
Ouyang, G., Zhao, W., & Pawliszyn, J. (2005) · Analytical Chemistry · doi:10.1021/ac051493z · Cited by 81
Melwanki, M. B., & Fuh, M.-R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.007 · Cited by 81
Horstkotte, B., Alexovič, M., Maya, F., Duarte, C. M., Andruch, V., & Cerdá, V. (2012) · Talanta · doi:10.1016/j.talanta.2012.05.063 · Cited by 79
Ahmadi, R., Azooz, E. A., Yamini, Y., & Ramezani, A. M. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117019 · Cited by 82
Single Drop Microextraction Using Commercial Capillary Electrophoresis Instruments
Choi, K., Kim, S. J., Jin, Y. G., Jang, Y. O., Kim, J., & Chung, D. S. (2008) · Analytical Chemistry · doi:10.1021/ac801886b · Cited by 83
Trace element speciation using solid phase microextraction
Mester, Z., & Sturgeon, R. E. (2005) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2005.06.013 · Cited by 83
“The use of a single droplet for extraction purposes was first suggested by Cantwell [122–125] and Dasgupta [126–129] in the mid-1990s.”
MethodYousefi, S. M., Shemirani, F., & Ghorbanian, S. A. (2018) · Journal of Separation Science · doi:10.1002/jssc.201700807 · Cited by 79
Wu, Y., Xia, L., Chen, R., & Hu, B. (2008) · Talanta · doi:10.1016/j.talanta.2007.05.057 · Cited by 79
Tang, S., Liu, S., Guo, Y., Liu, X., & Jiang, S. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.04.037 · Cited by 84
Saraji, M., & Marzban, M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3496-z · Cited by 84
New extraction media in microextraction techniques. A review of reviews
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104386 · Cited by 77
Santos, L. O., dos Anjos, J. P., Ferreira, S. L. C., & de Andrade, J. B. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.04.012 · Cited by 80
Sobhi, H. R., Yamini, Y., Esrafili, A., & Abadi, R. H. H. B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.005 · Cited by 77
Tintrop, L. K., Salemi, A., Jochmann, M. A., Engewald, W., & Schmidt, T. C. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341468 · Cited by 80
Aguilera‐Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.030 · Cited by 76
Namera, A., Nakamoto, A., Nishida, M., Saito, T., Kishiyama, I., Miyazaki, S., Yahata, M., Yashiki, M., & Nagao, M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.091 · Cited by 76
Partitioned dispersive liquid–liquid microextraction
Melwanki, M. B., & Fuh, M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.052 · Cited by 84
Jouyban, A., Farajzadeh, M. A., & Afshar Mogaddam, M. R. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.06.004 · Cited by 75
Ranjbar Banforuzi, S., & Hadjmohammadi, M. R. (2017) · Talanta · doi:10.1016/j.talanta.2017.05.058 · Cited by 75
Tahmasebi, E., Yamini, Y., & Saleh, A. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.05.033 · Cited by 75
Zhao, X., Kong, W., Wei, J., & Yang, M. (2014) · Food Chemistry · doi:10.1016/j.foodchem.2014.04.060 · Cited by 76
Farajzadeh, M. A., Mogaddam, M. R. A., & Aghdam, A. A. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.02.033 · Cited by 76
Wu, J., & Lee, H. K. (2006) · Analytical Chemistry · doi:10.1021/ac060966e · Cited by 75
Hou, X., Zheng, X., Zhang, C., Ma, X., Ling, Q., & Zhao, L. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.08.010 · Cited by 75
Zang, X., Wang, J., Wang, O., Wang, M., Ma, J., Xi, G., & Wang, Z. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2296-1 · Cited by 75
Płotka‐Wasylka, J., Morrison, C., Biziuk, M., & Namieśnik, J. (2015) · Chemical Reviews · doi:10.1021/cr4006999 · Cited by 82
Gioti, E. M., Skalkos, D. C., Fiamegos, Y. C., & Stalikas, C. D. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.07.038 · Cited by 75
Farahani, H., Yamini, Y., Shariati, S., Khalili-Zanjani, M. R., & Mansour-Baghahi, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.08.001 · Cited by 74
Wu, H.-F., Yen, J.-H., & Chin, C.-C. (2006) · Analytical Chemistry · doi:10.1021/ac052076p · Cited by 74
An overview of liquid phase microextraction approaches combined with UV–Vis spectrophotometry
Abadi, M. D. M., Ashraf, N., Chamsaz, M., & Shemirani, F. (2012) · Talanta · doi:10.1016/j.talanta.2012.05.027 · Cited by 82
Vortex-assisted surfactant-enhanced-emulsification liquid–liquid microextraction
Yang, Z., Lu, Y., Liu, Y., Wu, T., Zhou, Z., & Liu, D. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.08.029 · Cited by 74
YILMAZ, E., & SOYLAK, M. (2016) · TURKISH JOURNAL OF CHEMISTRY · doi:10.3906/kim-1605-26 · Cited by 73
Gjelstad, A., Rasmussen, K. E., Parmer, M. P., & Pedersen‐Bjergaard, S. (2013) · Bioanalysis · doi:10.4155/bio.13.59 · Cited by 78
Mixed liquids for single-drop microextraction of organochlorine pesticides in vegetables
Zhang, M., Huang, J., Wei, C., Yu, B., Yang, X., & Chen, X. (2007) · Talanta · doi:10.1016/j.talanta.2007.06.041 · Cited by 75
Liu, D., & Min, S. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.02.070 · Cited by 74
Viñas, P., Martínez-Castillo, N., Campillo, N., & Hernández‐Córdoba, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.08.046 · Cited by 73
Electrical potential can drive liquid-liquid extraction for sample preparation in chromatography
Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.08.005 · Cited by 72
Pan, H.-J., & Ho, W. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.08.016 · Cited by 72
Chisvert, A., Benedé, J. L., & Salvador, A. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.059 · Cited by 79
A review of green solvent extraction techniques and their use in antibiotic residue analysis
Khataei, M. M., Epi, S. B. H., Lood, R., Spégel, P., Yamini, Y., & Turner, C. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114487 · Cited by 74
Mandal, S., Poi, R., Hazra, D. K., Ansary, I., Bhattacharyya, S., & Karmakar, R. (2022) · Journal of Chromatography B · doi:10.1016/j.jchromb.2022.123587 · Cited by 81
Psillakis, E., Mantzavinos, D., & Kalogerakis, N. E. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.015 · Cited by 72
Solvent microextraction: A review of recent efforts at automation
Kocúrová, L., Balogh, I. S., & Andruch, V. (2013) · Microchemical Journal · doi:10.1016/j.microc.2013.07.009 · Cited by 74
Hollow fiber-mediated liquid-phase microextraction of chemical warfare agents from water
Dubey, D. K., Pardasani, D., Gupta, A. K., Palit, M., Kanaujia, P. K., & Tak, V. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.12.095 · Cited by 71
See, H. H., & Hauser, P. C. (2011) · Analytical Chemistry · doi:10.1021/ac201772g · Cited by 71
Ma, J., Zhang, J., Du, X., Lei, X., & Li, J. (2010) · Microchimica Acta · doi:10.1007/s00604-009-0275-7 · Cited by 71
“In 1996, Jeannot and Cantwell [20] developed a liquid-phase microextraction (LPME) technique, which is based on analyte partitioning between a drop of organic solvent (extraction phase) and a bulk aqueous sample.”
Sorbent Coated Glass Wool Fabric as a Thin Film Microextraction Device
Kermani, F. R., & Pawliszyn, J. B. (2012) · Analytical Chemistry · doi:10.1021/ac301861z · Cited by 71
25,000-fold pre-concentration in a single step with liquid-phase microextraction
Ho, T. S., Vasskog, T., Anderssen, T., Jensen, E., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.04.014 · Cited by 70
Xiao, Q., Hu, B., Duan, J., He, M., & Zu, W. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.07.006 · Cited by 70
“To reduce the consumption of organic solvents, single drop microextraction (SDME) was introduced in 1996 [11, 12].”
MethodChen, B., Huang, Y., He, M., & Hu, B. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.06.029 · Cited by 75
Cruz‐Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.06.035 · Cited by 70
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Affiliations
- University of Alberta (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2236-2240
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973396905
- Cited by
- 1,282
- References
- 27
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 34 · 2021: 40 · 2020: 53 · 2019: 66 · 2018: 43 · 2017: 41 · 2016: 49 · 2015: 68 · 2014: 80 · 2013: 84 · 2012: 99
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- solvent extraction, gas chromatography, solvent reduction, 4-methylacetophenone, n-octane, internal standard
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.