Solvent Microextraction into a Single Drop
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An analytical technique is described which combines solvent extraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little solvent consumption. A small drop (8 μL) of a water-immiscible organic solvent, containing an internal standard, is located at the end of a Teflon rod which is immersed in a stirred aqueous sample solution. After the solution has been stirred for a prescribed period of time, the probe is withdrawn from the aqueous solution, and the organic phase is sampled with a microsyringe and injected into the GC for quantification. The observed rate of solvent extraction is in good agreement with a convective-diffusive kinetic model. Analytically, the relative standard deviation of the method is 1.7% for a 5.00-min extraction of the analyte 4-methylacetophenone into n-octane.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various methods like agitation, stirring, vibration, shaking, and irradiation with ultrasonic waves have been applied to improve the extraction efficiency of LPME methods via increasing the mass transfer rate [83,168].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [168]
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Handbook of Solvent Extraction
Lo, T. C., Baird, M. H. I., & Hanson, C. A. (1991) · Cited by 983
Automation and optimization of solid-phase microextraction
Arthur, C. L., Killam, L. M., Buchholz, K. D., Pawliszyn, J., & Berg, J. R. (1992) · Analytical Chemistry · doi:10.1021/ac00041a034 · Cited by 620
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Membrane approach to solid-phase extractions
Hagen, D. F., Markell, C. G., Schmitt, G. A., & Blevins, D. D. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83309-7 · Cited by 235
The Kinetics of Metal Solvent Extraction
Danesi, P. R., Chiarizia, R., & Coleman, C. F. (1980) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408348008085494 · Cited by 222
Measurement of liquid-liquid interfacial kinetics
Hanna, G. J., & Noble, R. D. (1985) · Chemical Reviews · doi:10.1021/cr00070a004 · Cited by 151
Interfacial transfer studied with a rotating diffusion cell
Albery, W. J., Burke, J. F., Leffler, E. B., & Hadgraft, J. (1976) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19767201618 · Cited by 144
Some Measurements of Diffusion in Liquids.
Chang, P., & Wilke, C. R. (1955) · The Journal of Physical Chemistry · doi:10.1021/j150529a005 · Cited by 143
Transport phenomena in liquid extraction
Laddha, G. S., & Degaleesan, T. E. (1976) · Andalas University Repository (Andalas University) · Cited by 123
Research works printed but not linked: 7
- Lucy C. A., 1994, Anal. Chem., 66, 2225
- Davies, J. T.; Rideal, E. K. Interfacial Phenomena ; Academic Press: New York, 1961; Chapter 7.
- Grushka E., 1974, J. Phys. Chem., 78, 2301
- Liley, P. E.; Reid, R. C.; Buck, E. In Chemical Engineers' Handbook , 6th ed.; Perry, R. H., Green, D. W., Eds.; McGraw-Hill: New York, 1984; Chapter 3, pp 258−259.
- Laddha G. S., 1976, Transport Phenomena in Liquid Extraction
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
Cited by
Items 901–1,000 of 1,001
Hong, J., Hao, X., Liu, T., Liu, W., Xie, M., Wang, M., Xu, Q., & Yang, B. (2020) · Analytical Letters · doi:10.1080/00032719.2020.1717508 · Cited by 13
Ferreira, V. J., Virgens, F. B. S., Pires, L. N., Dias, F. D. S., Lemos, V. A., & Teixeira, L. S. G. (2022) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2022.2113537 · Cited by 12
“Another example is the determination of Zn and Cu in water samples by wavelength dispersive X-ray fluorescence (WDXRF) after preconcentration by LPE.”
MethodInfluentialAdvance on the sample preparation and analytical methods for water disinfection byproducts
Huang, H., Wei, X., Weng, S., Zhang, Z., & Li, G. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117670 · Cited by 12
Trace element determination using mass spectrometry coupled detection methods
Chormey, D. S., Er, E. Ö., Bodur, S. E., Zaman, B. T., Bodur, S., Borahan, T., Kayın, İ., & Bakırdere, S. (2024) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2024.e00257 · Cited by 13
Rajabi, M., Bazregar, M., Yamini, Y., Asghari, A., & Ebrahimpour, B. (2015) · Microchemical Journal · doi:10.1016/j.microc.2015.10.035 · Cited by 12
Maham, M., Kiarostami, V., Waqif‐Husain, S., & Sharifabadi, M. K. (2014) · Brazilian Journal of Pharmaceutical Sciences · doi:10.1590/s1984-82502014000300014 · Cited by 13
Tehrani, M. S., Azar, P. A., & Raziee, M. (2013) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2012.745144 · Cited by 12
“usage.([17]) In single drop microextraction (SDME), a drop of organic solvent is suspended in the aqueous sample acts as an extraction phase.”
BackgroundLi, S., Yang, X., Hu, L., Cui, X., Zhang, S., Lu, R., Zhou, W., & Gao, H. (2014) · Analytical Methods · doi:10.1039/c4ay00806e · Cited by 13
Sharma, M. K., Dhakne, P., Nn, S., Reddy, P. A., & Sengupta, P. (2019) · Analytical Sciences · doi:10.2116/analsci.19r003 · Cited by 12
Huber, S., Harder, M., Funck, K., Erharter, K., Popp, M. A., Bonn, G. K., & Rainer, M. (2020) · Separations · doi:10.3390/separations7030045 · Cited by 13
Nanoextraction based on surface nanodroplets for chemical preconcentration and determination
Wu, H., Kanike, C., Atta, A., & Zhang, X. (2022) · Biomicrofluidics · doi:10.1063/5.0121912 · Cited by 14
Ma, W., Xing, R., Hu, S., Chen, X., & Bai, X. (2014) · Analytical Methods · doi:10.1039/c4ay00990h · Cited by 12
Farajzadeh, M. A., Goushjuii, L., & Bashour, Y. (2010) · Journal of Separation Science · doi:10.1002/jssc.201000510 · Cited by 14
Determination of 2-Methylisoborneol and Geosmin Produced by Streptomyces sp. and Anabaena PCC7120
Xie, Y., He, J., Huang, J., Zhang, J., & Yu, Z. (2007) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf070125o · Cited by 12
Elečková, L., Balogh, I. S., Imrich, J., & Andruch, V. (2015) · Journal of Analytical Chemistry · doi:10.1134/s1061934815030053 · Cited by 12
Wang, X., Cheng, J., Xiao, J., Wang, X., Chen, M., & Cheng, M. (2013) · Analytical Methods · doi:10.1039/c3ay26507b · Cited by 12
Recent advances of green pretreatment techniques for quality control of natural products
Du, K., Sun, A., Yan, C., Liang, C., Qi, L., Wang, C., Yang, R. C., Cui, Y., Shang, Y., Li, J., et al. (2020) · Electrophoresis · doi:10.1002/elps.202000084 · Cited by 13
Tie, D., Chen, X., Wang, R., Hu, S., Yang, L. C., & Zheng, Y. F. (2021) · Microchemical Journal · doi:10.1016/j.microc.2021.106348 · Cited by 13
Kaykhaii, M., & Moradi, M. (2008) · Journal of Chromatographic Science · doi:10.1093/chromsci/46.5.413 · Cited by 12
A coacervative extraction based on single-chain and double-chain cationic surfactants
Kukusamude, C., Quirino, J. P., & Srijaranai, S. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.10.030 · Cited by 12
Pseudoneoplastic lesions of the lower female genital tract.
Young, R. H., & Clement, P. B. (1989) · PubMed · Cited by 13
Liquid‐Phase Microextraction (LPME) Utilizing Porous Hollow Fibers
Pedersen‐Bjergaard, S., Rasmussen, K. E., & Jönsson, J. Å. (2010) · Wiley eBooks · doi:10.1002/9780813823621.ch7 · Cited by 12
Single-Drop Microextraction for Bioanalysis: Present and Future
Kailasa, S. K., & Wu, H. (2013) · Bioanalysis · doi:10.4155/bio.13.231 · Cited by 12
Trends in extraction and purification methods of Lignans in plant-derived foods
Yang, Y., Zhang, Y., Bian, Y., Zhu, J., & Feng, X. (2025) · Food Chemistry X · doi:10.1016/j.fochx.2025.102249 · Cited by 11
“DI-SDME was first put forward by Jeannot and Cantwell (1996).”
Ponnusamy, V. K., Ramkumar, A., & Jen, J. (2012) · Microchimica Acta · doi:10.1007/s00604-012-0877-3 · Cited by 11
Villar-Navarro, M., Ramos‐Payán, M., Fernández‐Torres, R., & Bello‐López, M. Á. (2012) · Biomedical Chromatography · doi:10.1002/bmc.2783 · Cited by 12
Wen, X., Deng, Q., Wang, J., & Zhao, X. (2013) · Analytical Methods · doi:10.1039/c3ay40229k · Cited by 11
Uzcan, F., Jagirani, M. S., & Soylak, M. (2022) · TURKISH JOURNAL OF CHEMISTRY · doi:10.55730/1300-0527.3479 · Cited by 12
“Jeannot and Cantwell reported solventbased microextraction into a single drop in 1996 to determine the organic compounds [133].”
BackgroundIntroduction to Green Sample Preparation
Canpolat, G., Dolak, İ., Hussain, C. G., Keçili, R., & Hussain, C. M. (2023) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781839166419-00001 · Cited by 14
Nikdel, M., Nezami, A., Yamini, Y., Nezhad, B. G., Nazaripour, A., Baghani, M., & Rahimzadegan, M. (2024) · Separation Science Plus · doi:10.1002/sscp.202300143 · Cited by 12
Saraji, M., & Khaje, N. (2012) · Bioanalysis · doi:10.4155/bio.12.26 · Cited by 11
Bidari, A., Ganjali, M. R., Assadi, Y., & Norouzi, P. (2011) · Analytical Methods · doi:10.1039/c0ay00741b · Cited by 13
Saraji, M., Ghani, M., Rezaei, B., & Mokhtarianpour, M. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.09.058 · Cited by 11
“Solvent microextraction technique by which analytes are extracted into a single drop of organic solvent was introduced by Cantwell and Jeannot [19].”
MethodUltrasound-assisted electromembrane extraction with supported semi-liquid membrane
Shang, Q., Mei, H., Feng, X., Huang, C., Pedersen‐Bjergaard, S., & Shen, X. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.339038 · Cited by 11
Chen, L., Wang, J., Xu, T., Feng, X., Huang, C., & Shen, X. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114364 · Cited by 12
Wang, Q., Bian, Y., Zhang, Y., Sun, D., Wang, W.-L., Zhou, Y., Liu, Z., Feng, X., & He, Z.-W. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.108538 · Cited by 10
Tan, G. H., & Abdulra’uf, L. B. (2012) · InTech eBooks · doi:10.5772/48745 · Cited by 11
“3 μL chloroform suspended in a large aqueous solution containing a methylene blue active substance [79], and later by Jeannot and Cantwell for the extraction of 4-methyacetophenone in aqueous solution, using 8 μL of n-octane suspended at the end of a Teflon rod [80].”
MethodShrivas, K. K., & Dewangan, K. (2015) · Journal of Surfactants and Detergents · doi:10.1007/s11743-015-1745-z · Cited by 11
Liu, Y., He, M., Chen, B., & Hu, B. (2015) · Analytical Methods · doi:10.1039/c5ay01181g · Cited by 12
Liquid-Based Microextraction Techniques for Environmental Analysis
He, Y. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00116-2 · Cited by 20
He, S., Shen, C., Wei, X. Q., Jin, M. C., & Cai, M. Q. (2013) · Advanced materials research · doi:10.4028/www.scientific.net/amr.726-731.74 · Cited by 11
Faraji, H., & M.A.Tehrani, R. (2012) · International Journal of Industrial Chemistry · doi:10.1186/2228-5547-3-12 · Cited by 11
5 Choice of Solvent in Liquid-Phase Microextraction
Dadfarnia, S., & Haji-Shabani, A. M. (2014) · doi:10.2478/9783110410181.5 · Cited by 14
Talaee, M., Lorestani, B., Ramezani, M., Cheraghi, M., & Jamehbozorgi, S. (2019) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2019.1618460 · Cited by 12
Pourbakhshi, Y., Heidari, M., Yahaei, E., Ghiyasi, S., Ebrahimi-Najafabadi, H., & Bozorgzadeh, E. (2021) · Journal of Analytical Chemistry · doi:10.1134/s1061934821060083 · Cited by 10
Applications of Mass Spectrometry in Textile Analysis: An Overview
Ruan, Y., Meng, X., Wang, J., Wang, H., Ye, Q., Shou, Q., & Ma, Q. (2024) · Journal of Analysis and Testing · doi:10.1007/s41664-024-00322-1 · Cited by 10
“Since its introduction, LPME has developed various modes, including single-drop LPME [78], dispersive liquid–liquid micro-extraction (DLLME) [79], hollow-fiber LPME [80], and solidified floating organic drop-based LPME [81].”
Pierri, M. E., Morés, L., Bernardi, G., & Carasek, E. (2022) · Analytical Biochemistry · doi:10.1016/j.ab.2022.114725 · Cited by 10
Current Trends in Liquid-Liquid Microextraction for Analysis of Pesticide Residues in Food and Water
Sara, C., Fernandes, J. O., & Oliveir, M. B. P. P. (2011) · InTech eBooks · doi:10.5772/14185 · Cited by 15
Bahar, S., & Babamiri, B. (2014) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-014-0453-3 · Cited by 10
Es’haghi, Z., & Babazadeh, F. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2012.02.019 · Cited by 10
Liu, X., Liang, S., Pan, J., Guo, Y., Luo, H., Zhao, Q., & Guan, S. (2013) · Journal of Chromatographic Science · doi:10.1093/chromsci/bmt079 · Cited by 10
Ionic Liquids in Sample Preparation
Lucena, R., & Cárdenas, S. (2017) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2017.01.007 · Cited by 10
Faraji, H., Tajbakhsh, M., & Helalizadeh, M. (2012) · Analytical Methods · doi:10.1039/c2ay25336d · Cited by 11
Pakade, Y. B., Sharma, R., Nadda, G., & Tewary, D. K. (2013) · International Journal of Food Properties · doi:10.1080/10942912.2011.565900 · Cited by 10
“[15] Single drop microextraction (SDME), developed in 1996 by Jeannot and Cantwell,[16] provides an alternative technique, which integrates sampling, extraction, concentrating, and sample introduction in a single step.”
MethodInfluentialXue, X., Zhao, Z., Li, Q., Wang, D., Xu, X., Zhu, L., & Yang, D. (2016) · Analytical Letters · doi:10.1080/00032719.2016.1149859 · Cited by 10
Kitamura, N., Konno, K., & Ishizaka, S. (2017) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.20160401 · Cited by 10
Microextraction With Supported Liquid Membranes
Pedersen‐Bjergaard, S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816911-7.00008-6 · Cited by 14
Modern Approaches to Preparation of Body Fluids for Determination of Bioactive Compounds
Madej, K., & Piekoszewski, W. (2019) · Separations · doi:10.3390/separations6040053 · Cited by 11
“Single-drop microextraction (SDME), the simplest mode of LPME, was introduced by Liu and Dasgupta [26], as well as by Jeannot and Cantwell in 1996 [27].”
MethodEncapsulated Nanodroplets for Enhanced Fluorescence Detection by Nano‐Extraction
Li, M., Cao, R., Dyett, B., & Zhang, X. (2020) · Small · doi:10.1002/smll.202004162 · Cited by 10
Fast Analytical Techniques Based on Microextraction
Jiang, R., & Ouyang, G. (2015) · Comprehensive analytical chemistry · doi:10.1016/b978-0-444-63299-9.00003-x · Cited by 10
A novel hydrogel based microextraction of analytes
Bahram, M., Keshvari, F., & Mohseni, N. (2013) · Journal of Saudi Chemical Society · doi:10.1016/j.jscs.2013.05.002 · Cited by 11
Martins, R. O., Will, C., Magalhães, M. F. A., & Lanças, F. M. (2025) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2025.100240 · Cited by 11
Research advances in sample pretreatment techniques for pesticide residues
Cui, J., & Dong, F. (2025) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2025.100259 · Cited by 13
Electrokinetic removal of charged species from small sample volumes
Quirino, J. P. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.05.055 · Cited by 11
Chen, S., Wang, Y., Yan, J., Wang, C., & Lu, D. (2023) · Journal of Food Measurement & Characterization · doi:10.1007/s11694-023-01907-7 · Cited by 9
“As a simplified sample preparation method, direct immersion single-drop microextraction (DI-SDME) has attracted considerable attention in analytical sciences since the mid-1990s [34].”
Deep eutectic solvents for the determination of endocrine disrupting chemicals
Chormey, D. S., Zaman, B. T., Borahan, T., Erarpat, S., Bodur, S., Er, E. Ö., & Bakırdere, S. (2023) · Talanta · doi:10.1016/j.talanta.2023.125340 · Cited by 9
Yan, X., Wu, D., Meng, H., Hao, L., Ding, K., & Guan, Y. (2013) · Analytical Methods · doi:10.1039/c3ay41525b · Cited by 12
Ghiasvand, A., Yazdankhah, F., & Hajipour, S. (2016) · Journal of Separation Science · doi:10.1002/jssc.201600142 · Cited by 10
Yue, C. S., Hong, W. L., Tan, S.-A. S. W., Loh, K. E., Liew, Y. C., Yap, R. E., Chong, Z. Y., & Chai, J. C. (2019) · Indonesian Journal of Chemistry · doi:10.22146/ijc.37782 · Cited by 9
“These include liquid-liquid extraction [12], solid-phase extraction [20], cloud point micro-extraction [3], and liquid-phase microextraction [21].”
MethodManousi, N., & Samanidou, V. (2019) · Separations · doi:10.3390/separations6020024 · Cited by 10
“Single-drop microextraction (SDME) is a variation of LPME, that was firstly introduced in 1996 by Jeannot and Cantwell [76].”
BackgroundPurgat, K., Kośka, I., & Kubalczyk, P. (2021) · Molecules · doi:10.3390/molecules26185687 · Cited by 9
“This microextraction technique was first used in the middle of the 1990’s [23], and it is a powerful tool that can be realized either outside (off-line) or inside (on-line) a GC, HPLC, and CE system.”
Methodjam, M. R., Nezhadali, A., & Kaykhaii, M. (2022) · BMC Chemistry · doi:10.1186/s13065-022-00823-z · Cited by 10
“Jeannot MA, Cantwell FF. Solvent microextraction into a single drop.”
MethodLi, Z., Wu, H., You, J. B., Wang, X., Zeng, H., Lohse, D., & Zhang, X. (2022) · Langmuir · doi:10.1021/acs.langmuir.2c01242 · Cited by 9
Pre-concentration and Sample Treatment Techniques for Trace Element Analysis
Hu, B., & He, M. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00154-x · Cited by 11
Moradi, M., Ferdowsi, M., Tqian-Nasab, A., & Najafi, A. (2015) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-015-0632-x · Cited by 9
Gal, C., & Nuţiu, R. (2008) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067310701819002 · Cited by 9
Ensafi, A. A., Rabiei, S., Rezaei, B., & Jafari-Asl, M. (2013) · Analytical Methods · doi:10.1039/c3ay40388b · Cited by 9
RetractedWang, G., Dong, C., Sun, Y.-A., Xie, K., & Zheng, H. (2008) · Journal of Chromatographic Science · doi:10.1093/chromsci/46.2.127 · Cited by 10
Microextraction techniques in antibiotic monitoring in body fluids: Recent trends and future
Jafari, S., & Hamidi, S. (2018) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2017.1399418 · Cited by 9
“In single-drop microextraction (SDME) version, the extraction device directly dipped into the sample or suspended above the solution in the void space for headspace extraction.([11,12]) Latter one is known as headspace single-drop microextraction (HS-SDME) and is suitable for concentration 402 S.”
MethodBahadır, Z., & Mermer, A. (2020) · Analytical Letters · doi:10.1080/00032719.2020.1785484 · Cited by 9
Kokosa, J. M. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.11640-3 · Cited by 9
Kim, N.-S. (2005) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2005.26.12.1996 · Cited by 9
Wei, G., Li, Y., & Wang, X. (2008) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067310701769637 · Cited by 9
New Sample Preparation Strategies for Analytical Determinations
Quintana, J. B., Ramil, M., Rodil, R., Rodríguez, I., & Cela, R. (2014) · Wiley eBooks · doi:10.1002/9780470027318.a9392 · Cited by 11
Bubble‐Assisted Sample Preparation Techniques for Mass Spectrometry
Elpa, D. P., & Urban, P. L. (2024) · Mass Spectrometry Reviews · doi:10.1002/mas.21913 · Cited by 8
Research Progress on Single-Droplet Microextraction Technology
Yang, S., Zhang, M., Wang, S., He, Y., Ren, S., Zhang, Y., & Gao, P. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c04005 · Cited by 8
Towards safer medicines: management of residual solvents and green alternatives
Guerassimoff, L., & Nicolas, J. (2026) · Journal of Controlled Release · doi:10.1016/j.jconrel.2026.114643 · Cited by 8
The advances of electromigration techniques applied for alkaloid analysis
Dziomba, S., Belka, M., Kowalski, P., Plenis, A., & Bączek, T. (2013) · Biomedical Chromatography · doi:10.1002/bmc.2967 · Cited by 8
Research progress on pretreatment technology for the analysis of amphetamine biological samples
Cao, Z., & Zhou, J. (2024) · Journal of Separation Science · doi:10.1002/jssc.202400337 · Cited by 8
Carasek, E., Morés, L., da Cunha, N., Branco, G. L., & Dias, A. N. (2024) · Advances in Sample Preparation · doi:10.1016/j.sampre.2024.100139 · Cited by 10
Ciucanu, I., & Agotici, V. (2012) · Journal of Separation Science · doi:10.1002/jssc.201101105 · Cited by 8
Curyło, J., & Wardencki, W. (2006) · Analytical Letters · doi:10.1080/00032710600824763 · Cited by 8
“It combines classic extraction by liquid and microextraction to stationary phase, described by Jeannot and Cantwell ( 1996 ).”
MethodMenezes, R. M., Oliveira, R. V., de Oliveira, D. M., & Lemos, V. A. (2016) · Water Air & Soil Pollution · doi:10.1007/s11270-016-2842-y · Cited by 8
“This microdrop is exposed to the sample solution, suspended on the tip of the needle of a syringe following extraction, and the microdrop is conducted, suctioned, and used in the detection procedure (Jeannot and Cantwell 1996).”
Liao, P.-H., & Urban, P. L. (2019) · ACS Omega · doi:10.1021/acsomega.9b02273 · Cited by 8
Nicotine in Complex Samples: Recent Updates on the Pretreatment and Analysis Method
Tao, X.-Y., Zhang, Y., Zhou, Y., Liu, Z., & Feng, X. (2021) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2021.2016365 · Cited by 8
“LPME, which was first reported in the 1990s by Jeannot and Cantwell,([123]) has attracted a lot of attention in recent years.”
BackgroundEnvironmental Applications: Atmospheric Trace Gas Analyses
Toda, K., & Dasgupta, P. Κ. (2008) · Comprehensive analytical chemistry · doi:10.1016/s0166-526x(08)00622-3 · Cited by 8
Temporal patterns, sources, and sinks of C8‐C16 hydrocarbons in the atmosphere of Mace Head, Ireland
Sartin, J. H., Halsall, C. J., L. A. Robertson, Gonard, R. G., MacKenzie, A. R., Berresheim, H., & HEWITT, C. N. (2002) · Journal of Geophysical Research Atmospheres · doi:10.1029/2000jd000232 · Cited by 8
“Principles behind microextraction are given by Jeannot and Cantwell [1996]. Briefly, the procedure involved adding 2 mL of n-pentane to 100 mL seawater in a volumetric flask.”
MethodHuang, Z., Meng, X., Liu, M., & Wang, S. (2014) · Analytical Methods · doi:10.1039/c4ay01198h · Cited by 8
Sun, A., Xu, Q., Xu, S., Shangguan, X., Shen, H., & Sun, J. (2013) · Analytical Letters · doi:10.1080/00032719.2013.803250 · Cited by 8
Chen, H., Chang, S.-K., Lee, C., Chuang, L., & Wei, G. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.02.022 · Cited by 8
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Affiliations
- University of Alberta (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2236-2240
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973396905
- Cited by
- 1,282
- References
- 27
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 34 · 2021: 40 · 2020: 53 · 2019: 66 · 2018: 43 · 2017: 41 · 2016: 49 · 2015: 68 · 2014: 80 · 2013: 84 · 2012: 99
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- solvent extraction, gas chromatography, solvent reduction, 4-methylacetophenone, n-octane, internal standard
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.