Solvent Microextraction into a Single Drop
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An analytical technique is described which combines solvent extraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little solvent consumption. A small drop (8 μL) of a water-immiscible organic solvent, containing an internal standard, is located at the end of a Teflon rod which is immersed in a stirred aqueous sample solution. After the solution has been stirred for a prescribed period of time, the probe is withdrawn from the aqueous solution, and the organic phase is sampled with a microsyringe and injected into the GC for quantification. The observed rate of solvent extraction is in good agreement with a convective-diffusive kinetic model. Analytically, the relative standard deviation of the method is 1.7% for a 5.00-min extraction of the analyte 4-methylacetophenone into n-octane.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various methods like agitation, stirring, vibration, shaking, and irradiation with ultrasonic waves have been applied to improve the extraction efficiency of LPME methods via increasing the mass transfer rate [83,168].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [168]
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Handbook of Solvent Extraction
Lo, T. C., Baird, M. H. I., & Hanson, C. A. (1991) · Cited by 983
Automation and optimization of solid-phase microextraction
Arthur, C. L., Killam, L. M., Buchholz, K. D., Pawliszyn, J., & Berg, J. R. (1992) · Analytical Chemistry · doi:10.1021/ac00041a034 · Cited by 620
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Membrane approach to solid-phase extractions
Hagen, D. F., Markell, C. G., Schmitt, G. A., & Blevins, D. D. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83309-7 · Cited by 235
The Kinetics of Metal Solvent Extraction
Danesi, P. R., Chiarizia, R., & Coleman, C. F. (1980) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408348008085494 · Cited by 222
Measurement of liquid-liquid interfacial kinetics
Hanna, G. J., & Noble, R. D. (1985) · Chemical Reviews · doi:10.1021/cr00070a004 · Cited by 151
Interfacial transfer studied with a rotating diffusion cell
Albery, W. J., Burke, J. F., Leffler, E. B., & Hadgraft, J. (1976) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19767201618 · Cited by 144
Some Measurements of Diffusion in Liquids.
Chang, P., & Wilke, C. R. (1955) · The Journal of Physical Chemistry · doi:10.1021/j150529a005 · Cited by 143
Transport phenomena in liquid extraction
Laddha, G. S., & Degaleesan, T. E. (1976) · Andalas University Repository (Andalas University) · Cited by 123
Research works printed but not linked: 7
- Lucy C. A., 1994, Anal. Chem., 66, 2225
- Davies, J. T.; Rideal, E. K. Interfacial Phenomena ; Academic Press: New York, 1961; Chapter 7.
- Grushka E., 1974, J. Phys. Chem., 78, 2301
- Liley, P. E.; Reid, R. C.; Buck, E. In Chemical Engineers' Handbook , 6th ed.; Perry, R. H., Green, D. W., Eds.; McGraw-Hill: New York, 1984; Chapter 3, pp 258−259.
- Laddha G. S., 1976, Transport Phenomena in Liquid Extraction
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
Cited by
Items 801–900 of 1,001
Lim, E., Kim, B., Oh, M. S., & You, J. B. (2023) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2023.03.201 · Cited by 19
Pouramiri, B., Rabiei, K., Meshkatalsadat, M. H., & Rashidi, M. (2023) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2023.136013 · Cited by 18
Borijihan, G., Li, Y., Gao, J., & Bao, J. J. (2014) · Journal of Separation Science · doi:10.1002/jssc.201300954 · Cited by 18
Son, H., Bae, S., & Lee, D. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.09.023 · Cited by 18
Wang, X., Yuan, K., Liu, H., Li, L., & Luan, T. (2014) · Journal of Separation Science · doi:10.1002/jssc.201400198 · Cited by 18
Tajik, M., Yamini, Y., Esrafili, A., & Ebrahimpour, B. (2014) · Journal of Separation Science · doi:10.1002/jssc.201401075 · Cited by 18
Kogi, O., Kim, H., & Kitamura, N. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)00958-2 · Cited by 18
Ghiasvand, A. R., & Heidari, N. (2016) · Chromatographia · doi:10.1007/s10337-016-3133-x · Cited by 17
“Furthermore, to overcome the drawbacks encountered in SPME, like fragility and high cost of the fibers, liquid-phase microextraction (LPME) was introduced [5] and followed by extensive research for the development of its different modes [6] and applications [7].”
BackgroundGuo, X., He, M., Nan, K., Yan, H., Chen, B., & Hu, B. (2015) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c5ja00286a · Cited by 17
Ponnusamy, V. K., & Jen, J. (2011) · Chemosphere · doi:10.1016/j.chemosphere.2010.12.041 · Cited by 17
Clavijo, S., Fernández, M., Forteza, R., Brunetto, M. D. R., & Cerdà, V. (2014) · Analytical Methods · doi:10.1039/c4ay00179f · Cited by 20
Application of hollow fiber liquid-phase microextraction in identification of oil spill sources
Li, Y., Xiong, Y., Fang, J., Wang, L., & Liang, Q. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.06.069 · Cited by 17
Wang, W., Zhu, H., Cui, S., Miao, J., & Chen, J. (2014) · Analytical Methods · doi:10.1039/c3ay42331j · Cited by 17
Fazeli-Bakhtiyari, R., Panahi‐Azar, V., Sorouraddin, M. H., & Jouyban, A. (2015) · PubMed Central · Cited by 19
Separation/Preconcentration Techniques for Rare Earth Elements Analysis
Hu, B., He, M., Chen, B., & Jiang, Z. (2016) · Physical Sciences Reviews · doi:10.1515/psr-2016-0056 · Cited by 19
Selecting an Appropriate Solvent Microextraction Mode for a Green Analytical Method
Kokosa, J. M. (2017) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2016.12.001 · Cited by 18
Liberto, E., Bicchi, C. P., Cagliero, C., Cordero, C. E. I., Rubiolo, P., & Sgorbini, B. (2019) · Royal Society of Chemistry eBooks · doi:10.1039/9781788015752-00001 · Cited by 26
Mohammadi, V., Jafari, M. T., & Saraji, M. (2020) · Microchimica Acta · doi:10.1007/s00604-020-4215-x · Cited by 17
Leng, G., Lin, L., Worsfold, P. J., Xu, W., Luo, X., Chang, L., Li, W., Zhang, X., & Xia, C. (2021) · Microchemical Journal · doi:10.1016/j.microc.2021.106441 · Cited by 19
Saraji, M., Khayamian, T., Mirmahdieh, S., & Bidgoli, A. A. H. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.09.017 · Cited by 17
Zhang, C., Ye, L., & Xu, L. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.01.045 · Cited by 17
Development and evaluation of plunger-in-needle liquid-phase microextraction
Zhang, H., Ng, B. W. L., & Lee, H. K. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.12.056 · Cited by 17
Su, R., Li, X., Liu, W., Wang, X., & Yang, H. (2016) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.5b05856 · Cited by 17
Pantůčková, P., & Kubáň, P. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.08.084 · Cited by 18
Michulec, M., & Wardencki, W. (2006) · Chromatographia · doi:10.1365/s10337-006-0009-5 · Cited by 17
Headspace single‐drop microextraction of herbal essential oils
Adam, M., Dobiáš, P., Eisner, A., & Ventura, K. (2008) · Journal of Separation Science · doi:10.1002/jssc.200700377 · Cited by 17
Jung, M.-J. (2006) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2006.27.2.231 · Cited by 17
Carlsson, K., & Karlberg, B. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)00851-5 · Cited by 17
Díaz-Álvarez, M., Turiel, E., & Martín-Esteban, A. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.343617 · Cited by 16
Horn, P. J., Joshi, U., Behrendt, A. K., Chapman, K. D., & Verbeck, G. F. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6194 · Cited by 16
Naddaf, E., Ebrahimi, M., Es’haghi, Z., & Bamoharram, F. F. (2015) · Journal of Separation Science · doi:10.1002/jssc.201401459 · Cited by 16
Ji, B., Xia, B., Fu, X., Lei, S., Ye, Y., & Zhou, Y. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.12.037 · Cited by 16
Ullah, N., & Tüzen, M. (2022) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2022.2128635 · Cited by 17
“[63] After at specific interval of time, the drop is withdrawn back and later may be directly injected to analyze the target analytes.”
Wu, Q., Wu, D., Duan, C., Shen, Z., & Guan, Y. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.09.066 · Cited by 16
The Role of Liquid-Phase Microextraction Techniques in Bioanalysis
Barroso, M., Gallardo, E., & Queiroz, J. A. (2015) · Bioanalysis · doi:10.4155/bio.15.136 · Cited by 16
Chen, Y., & Wu, H. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900133 · Cited by 16
Jiang, Y., Dong, X., Li, Y., Li, Y., Liang, Y. H., & Zhang, M. (2020) · Talanta · doi:10.1016/j.talanta.2020.121849 · Cited by 16
Kanchanamayoon, W. (2015) · Chromatographia · doi:10.1007/s10337-015-2934-7 · Cited by 16
Luo, G., Li, Y., & Bao, J. J. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9213-1 · Cited by 18
“Recently, there have been some reports on the pretreatment of steroid samples by liquid-phase microextraction (LPME) [28–30], sometimes called liquid–liquid microextraction, which overcomes the long time required, high solvent consumption, easy emulsification, and difficulty in automation”
Background1 From Conventional to Miniaturized Analytical Systems
Pena‐Pereira, F. (2014) · doi:10.2478/9783110410181.1 · Cited by 16
Cinelli, G., Cuomo, F., Ambrosone, L., Venditti, F., & Lopez, F. (2019) · Biotechnology Progress · doi:10.1002/btpr.2780 · Cited by 16
Talaee, M., Lorestani, B., Ramezani, M., Cheraghi, M., & Jamehbozorgi, S. (2019) · Journal of Separation Science · doi:10.1002/jssc.201900132 · Cited by 18
Yazdi, A. S., Abedi, M. R., & Es’haghi, Z. (2013) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2012.673212 · Cited by 17
“[ 21 , 22 ] It is simply a miniaturized format of LLE and overcomes many of its disadvantages as well as some of those of SPME.”
Importance of extracting solvent vapor pressure in headspace liquid-phase microextraction
Xue, Y., Yang, C., Ren, C., & Li, D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.020 · Cited by 16
Nagai, H., Miwa, N., Segawa, M., Wakida, S., & Chayama, K. (2009) · Journal of Applied Physics · doi:10.1063/1.3116092 · Cited by 16
Freitas, A. M. C., da Silva, M. G., & Cabrita, M. J. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00126-5 · Cited by 20
Yang, S.-H., Reddy, P. M., & Ho, Y. (2009) · Analytical Chemistry · doi:10.1021/ac902227z · Cited by 16
Innovative liquid phase extraction based analytical extraction techniques of antibiotics
Ntshani, G. M., & Tavengwa, N. T. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822850-0.00030-2 · Cited by 15
Chen, S., Yan, J., Wang, C., Zhang, C., & Lu, D. (2022) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2022.104967 · Cited by 15
Yu, Q., Wang, R., Xing, R., Yang, L. C., Chen, X., & Hu, S. (2023) · Journal of Separation Science · doi:10.1002/jssc.202200719 · Cited by 15
Etana, E., & Mekassa, B. (2024) · Chinese Journal of Analytical Chemistry · doi:10.1016/j.cjac.2024.100458 · Cited by 16
Anbia, M., Haghi, A., & Shariati, S. (2012) · Analytical Methods · doi:10.1039/c2ay00012a · Cited by 15
Arghavani‐Beydokhti, S., Asghari, A., Bazregar, M., & Rajabi, M. (2016) · RSC Advances · doi:10.1039/c6ra19414a · Cited by 15
Dias, F. D. S., Peixoto, L. B., Meira, L. A., & Barreto, J. A. (2018) · Analytical Methods · doi:10.1039/c8ay01401a · Cited by 15
Asfaw, A. A., Aspromonte, J., Wolfs, K., Schepdael, A. V., & Adams, E. (2018) · Journal of Separation Science · doi:10.1002/jssc.201800711 · Cited by 17
Surface nanodroplet-based nanoextraction from sub-milliliter volumes of dense suspensions
You, J. B., Lohse, D., & Zhang, X. (2021) · Lab on a Chip · doi:10.1039/d1lc00139f · Cited by 16
Cui, S., Ouyang, G., Duan, G., Hou, J., Luan, T., & Zhang, X. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.10.024 · Cited by 15
Steady-state kinetic model for headspace solvent microextraction
Schnobrich, C. R., & Jeannot, M. A. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.011 · Cited by 15
Self-citationPanahi, H. A., Ejlali, M., & Chabouk, M. (2015) · Biomedical Chromatography · doi:10.1002/bmc.3645 · Cited by 16
Seidi, S., Alavi, L., & Jabbari, A. (2018) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-018-1401-4 · Cited by 16
Román‐Hidalgo, C., Dvorak, M. W., Kubáň, P., Martín-Valero, M. J., & Bello‐López, M. Á. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02225-y · Cited by 15
Viscosity-Mediated Growth and Coalescence of Surface Nanodroplets
Meng, J., You, J. B., & Zhang, X. (2020) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.0c02220 · Cited by 15
Polyakova, O. V., Mazur, D. M., Artaev, V. B., & Lebedev, А. T. (2013) · Journal of Analytical Chemistry · doi:10.1134/s106193481313008x · Cited by 15
Adam, M., Dobiáš, P., Pavlíková, P., & Ventura, K. (2009) · Open Chemistry · doi:10.2478/s11532-009-0048-5 · Cited by 15
Li, X., Xu, X., Wang, X., & Ma, L. (2004) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/0306731042000208743 · Cited by 15
Asadi, M., Dadfarnia, S., Shabani, A. M. H., & Abbasi, B. (2016) · Food Analytical Methods · doi:10.1007/s12161-016-0449-y · Cited by 16
“Liquid phase microextraction (LPME), first introduced by Jeannot and Cantwell in 1996 (Jeannot and Cantwell 1996), is the miniaturized implementation of the conventional LLE in which the amount of organic solvent was greatly reduced.”
BackgroundGreen Sample Preparation Techniques for Chromatographic Determination of Small Organic Compounds
Namieśnik, J., Spietelun, A., & Marcinkowski, Ł. (2015) · International Journal of Chemical Engineering and Applications · doi:10.7763/ijcea.2015.v6.484 · Cited by 15
Li, Z., Fang, Y., Chen, P., Wang, Z., Wang, L., Ren, G., & Huang, Y. (2010) · International Journal of Environmental Analytical Chemistry · doi:10.1080/03067310902874673 · Cited by 14
Ito, R., Kawaguchi, M., Koganei, Y., Honda, H., Okanouchi, N., Sakui, N., Saito, K., & Nakazawa, H. (2009) · Analytical Sciences · doi:10.2116/analsci.25.1033 · Cited by 14
Sobhi, H. R., Farahani, H., Kashtiaray, A., & Farahani, M. R. (2011) · Journal of Separation Science · doi:10.1002/jssc.201000529 · Cited by 14
Nakajima, N., Yamada, M., Kakegawa, S., & Seki, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00176 · Cited by 14
Yohannes, A., Tolesa, T., Merdassa, Y., & Megersa, N. (2016) · Journal of Analytical & Bioanalytical Techniques · doi:10.4172/2155-9872.1000330 · Cited by 14
“However, SDME is not an exhaustive extraction technique; although the maximum sensitivity is attained at equilibrium, complete equilibrium need not to be attained provided that extraction conditions are reproduced [37].”
BackgroundProsen, H. (2019) · Separations · doi:10.3390/separations6040057 · Cited by 15
Modern Sample Preparation Techniques: A Brief Introduction
Sargazi, M., Hashemi, S. H., & Kaykhaii, M. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.100715 · Cited by 17
Interfacial Partitioning Enhances Microextraction by Multicomponent Nanodroplets
Wei, Z., You, J. B., Zeng, H., & Zhang, X. (2022) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.1c08618 · Cited by 14
Bocelli, M. D., Medina, D. A. V., Rodríguez, J. P. G., Lanças, F. M., & Santos‐Neto, Á. J. (2022) · Electrophoresis · doi:10.1002/elps.202100390 · Cited by 18
Hu, M.-H., Chen, H., Jiang, Y., & Zhu, H. (2013) · Chemical Papers · doi:10.2478/s11696-013-0391-z · Cited by 14
Mirparizi, E., Rajabi, M., Bazregar, M., & Asghari, A. (2017) · Journal of Separation Science · doi:10.1002/jssc.201601282 · Cited by 14
Nurerk, P., Liew, C. S. M., Bunkoed, O., Kanatharana, P., & Lee, H. K. (2019) · Talanta · doi:10.1016/j.talanta.2019.01.046 · Cited by 14
Ionic liquid dispersive liquid–liquid microextraction for pesticide residue analysis in honey
Zheng, Y.-Z., Wang, K., Liang, Q., Xue, X., Zhao, L., Chen, D., Wu, L., Guo, R., & Xiong, C.-L. (2019) · Journal of Apicultural Research · doi:10.1080/00218839.2019.1656701 · Cited by 15
Hatami, M., & Farhadi, K. (2011) · Biomedical Chromatography · doi:10.1002/bmc.1746 · Cited by 14
Xie, H.-Y., Yan, J., Jahan, S., Zhong, R., Fan, L.-Y., Xiao, H., Jin, X., & Cao, C. (2014) · The Analyst · doi:10.1039/c4an00033a · Cited by 14
Enhancing micro-scale membrane extraction by implementing a barrier film
Wang, X., & Mitra, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.052 · Cited by 15
Guo, Y. G., Zhang, J., Liu, D. N., & Fu, H. F. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0868-5 · Cited by 14
Headspace single-drop microextraction and GC–ECD determination of chlorpyrifos-ethyl in rat liver
Wielgomas, B., & Czarnowski, W. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1831-4 · Cited by 14
Zargar, B., Parham, H., & Hatamie, A. (2015) · Journal of Chromatographic Science · doi:10.1093/chromsci/bmv117 · Cited by 14
“Miniaturized LLE or liquid phase microextraction (LPME) was first introduced in 1996 (7, 8).”
BackgroundMicroextraction Techniques as a Sample Preparation Step for Metal Analysis
Biparva, P., & Abbas, A. (2012) · Atomic Absorption Spectroscopy · doi:10.5772/30501 · Cited by 13
“After extraction, solvent drop was removed from the end of the Teflon rod using a micro syringe and injected to analytical instrument (Jeannot and cantwell, 1996).”
MethodMelwanki, M. B., & Huang, S. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600050 · Cited by 15
Dynamic headspace time-extended helix liquid-phase microextraction
Huang, S.-P., Chen, P., & Huang, S. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.03.030 · Cited by 13
Wang, G., Li, T., Fan, Y.-M., & Qi, M. (2013) · Journal of Analytical Methods in Chemistry · doi:10.1155/2013/380705 · Cited by 13
“20 1H-Cyclopenta[1, 3]cyclopropa[1, 2]benzene,octahydro-7-methyl-3-methylene-4-(1methylethyl)-,[3aS-(3a.”
MethodGeorge, M. J., Madala, N. E., & Dubery, I. A. (2019) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2019.1618458 · Cited by 14
Srivastava, A., Singh, M., Singh, S. P., & Singh, S. P. (2019) · Energy, environment, and sustainability · doi:10.1007/978-981-15-0540-9_14 · Cited by 13
Liquid-phase microextraction in bioanalysis – How green can it be?
Hay, A. O., Hansen, F. A., Psillakis, E., & Pedersen‐Bjergaard, S. (2022) · Green Analytical Chemistry · doi:10.1016/j.greeac.2022.100028 · Cited by 15
Ferdowsi, M., Taghian, A., Najafi, A., & Moradi, M. (2014) · Journal of Separation Science · doi:10.1002/jssc.201401023 · Cited by 14
Sanagi, M. M., Ghani, N. F. Y. A., Miskam, M., Ibrahim, W. A. W., & Aboul-Enein, H. Y. (2010) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826071003608850 · Cited by 13
“Miniaturized LLE or liquid phase microextraction (LPME), was first introduced in 1996 by Jeannot and Cantwell,([12]) and was based on a droplet of organic solvent hanging at the end of a micro syringe needle.”
InfluentialEs’haghi, Z. (2011) · American Journal of Analytical Chemistry · doi:10.4236/ajac.2011.21001 · Cited by 13
“These techniques, based on the contact between two immiscible liquids, fall into two main categories, namely single-drop microextraction (SDME) [13,14] and hollow fiber liquid phase microextraction (HF-LPME) [15,16].”
BackgroundWu, S., Jin, T., Cheng, J., Zhou, H., & Cheng, M.-C. (2014) · Journal of Chromatographic Science · doi:10.1093/chromsci/bmu136 · Cited by 13
Yang, X.-L., Luo, M., & Ding, J. (2007) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(07)60032-2 · Cited by 13
Kashtiaray, A., Farahani, H., Farhadi, S., Rochat, B., & Sobhi, H. R. (2011) · American Journal of Analytical Chemistry · doi:10.4236/ajac.2011.24052 · Cited by 15
“An alternative solvent-minimized sample preparation approach to complement SPME appeared in the middle-to-late 1990s [10-12]; liquid-phase microextraction (LPME) utilizes only a small amount of solvent (low microliter range) for concentrating analytes from aqueous samples.”
BackgroundBordagaray, A., Millán, E., & García-Arrona, R. (2016) · Journal of Food Chemistry and Nanotechnology · doi:10.17756/jfcn.2016-021 · Cited by 13
“Liquid phase microextraction (LPME) introduces the idea of miniaturizing the classical LLE in a water-immiscible organic droplet [29].”
Background
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Affiliations
- University of Alberta (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2236-2240
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973396905
- Cited by
- 1,282
- References
- 27
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 34 · 2021: 40 · 2020: 53 · 2019: 66 · 2018: 43 · 2017: 41 · 2016: 49 · 2015: 68 · 2014: 80 · 2013: 84 · 2012: 99
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- solvent extraction, gas chromatography, solvent reduction, 4-methylacetophenone, n-octane, internal standard
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.