The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Mass Transfer Characteristics of Solvent Extraction into a Single Drop at the Tip of a Syringe Needle
Abstract
The amount of a sample compound extracted into a 1-μL drop of n -octane suspended in a stirred aqueous solution from the tip of a microsyringe needle is measured by gas chromatography (GC) as a function of time. The observed extraction rate curve is first order and yields the overall mass transfer coefficient for the sample compound, β o . For a given compound, β o varies linearly with stirring rate. Among the four compounds malathion, 4-methylacetophenone, 4-nitrotoluene, and progesterone, at a given stirring rate, β o is linearly proportional to the diffusion coefficient of the compound ( D aq ). This supports the film theory of convective−diffusive mass transfer, as opposed to the penetration theory. The relative standard deviation of the GC signal for 4-methylacetophenone after a 1.00 min extraction at 1500 rpm is 1.5%, which suggests that the system exhibits excellent potential as a tool for rapid analysis by solvent extraction/GC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Significance of Liquid-Film Coefficients in Gas Absorption
Danckwerts, P. V. (1951) · Industrial & Engineering Chemistry · doi:10.1021/ie50498a055 · Cited by 1,560
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Self-citationTheorie der Reaktionsgeschwindigkeit in heterogenen Systemen
Nernst, W. (1904) · Zeitschrift für Physikalische Chemie · doi:10.1515/zpch-1904-4704 · Cited by 899
Cited by
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
A new liquid-phase microextraction method based on solidification of floating organic drop
Khalili Zanjani, M. R., Yamini, Y., Shariati, S., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.049 · Cited by 512
Dispersive liquid-liquid microextraction
Zgoła-Grześkowiak, A., & Grześkowiak, T. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.014 · Cited by 476
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Developments in single-drop microextraction
Xu, L., Basheer, C., & Lee, H. K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.073 · Cited by 382
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Vortex-assisted liquid–liquid microextraction of octylphenol, nonylphenol and bisphenol-A
Yiantzi, E., Psillakis, E., Tyrovola, K., & Kalogerakis, N. (2010) · Talanta · doi:10.1016/j.talanta.2009.11.005 · Cited by 338
Ahmadi, F., Assadi, Y., Hosseini, S. M. R. M., & Rezaee, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.017 · Cited by 325
Nagaraju, D., & Huang, S.-D. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.065 · Cited by 312
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Critical review on recent developments in solventless techniques for extraction of analytes
Nerín, C., Salafranca, J., Aznar, M., & Batlle, R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2437-6 · Cited by 284
Critical overview of selected contemporary sample preparation techniques
Ramos, L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.11.011 · Cited by 280
Single drop microextraction—Development, applications and future trends
Jeannot, M. A., Przyjazny, A., & Kokosa, J. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.089 · Cited by 276
Self-citationRecent advances and trends in miniaturized sample preparation techniques
Soares da Silva Burato, J., Vargas Medina, D. A., de Toffoli, A. L., Vasconcelos Soares Maciel, E., & Mauro Lanças, F. (2020) · Journal of Separation Science · doi:10.1002/jssc.201900776 · Cited by 254
Liquid–phase microextraction: A review of reviews
Rutkowska, M., Płotka-Wasylka, J., Sajid, M., & Andruch, V. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.103989 · Cited by 244
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
Xiong, J., & Hu, B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.03.072 · Cited by 228
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
He, L., Luo, X., Xie, H., Wang, C., Jiang, X., & Lu, K. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.09.044 · Cited by 212
Tang, S., Qi, T., Ansah, P. D., Nalouzebi Fouemina, J. C., Shen, W., Basheer, C., & Lee, H. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.016 · Cited by 195
One-step in-syringe ionic liquid-based dispersive liquid–liquid microextraction
Cruz-Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.040 · Cited by 154
Pena-Pereira, F., Lavilla, I., Bendicho, C., Vidal, L., & Canals, A. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.003 · Cited by 143
Basheer, C., Balasubramanian, R., & Lee, H. K. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)01295-0 · Cited by 143
Deep eutectic solvent-based dispersive liquid-liquid microextraction
Farajzadeh, M. A., Afshar Mogaddam, M. R., & Aghanassab, M. (2016) · Analytical Methods · doi:10.1039/c5ay03189c · Cited by 141
FARAHANI, H., GANJALI, M., DINARVAND, R., & NOROUZI, P. (2008) · Talanta · doi:10.1016/j.talanta.2008.03.002 · Cited by 123
Stanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116
Ozcan, S., Tor, A., & Aydin, M. E. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.037 · Cited by 113
Chisvert, A., Román, I. P., Vidal, L., & Canals, A. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.078 · Cited by 112
Li, Y., Wei, G., Hu, J., Liu, X., Zhao, X., & Wang, X. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.03.038 · Cited by 109
Charalabaki, M., Psillakis, E., Mantzavinos, D., & Kalogerakis, N. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2005.01.040 · Cited by 101
Recent achievements in solidified floating organic drop microextraction
Viñas, P., Campillo, N., & Andruch, V. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.005 · Cited by 99
Tsai, W.-H., Chuang, H.-Y., Chen, H.-H., Huang, J.-J., Chen, H.-C., Cheng, S.-H., & Huang, T.-C. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.10.008 · Cited by 98
Zounr, R. A., Tuzen, M., & Khuhawar, M. Y. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.034 · Cited by 96
Mohamadi, M., & Mostafavi, A. (2010) · Talanta · doi:10.1016/j.talanta.2009.12.004 · Cited by 91
Farajzadeh, M. A., Djozan, D., & Khorram, P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.11.030 · Cited by 89
Chamsaz, M., Arbab-Zavar, M. H., & Nazari, S. (2003) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b303169a · Cited by 83
Melwanki, M. B., & Fuh, M.-R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.007 · Cited by 81
Leong, M.-I., Chang, C.-C., Fuh, M.-R., & Huang, S.-D. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.06.056 · Cited by 80
Sobhi, H. R., Yamini, Y., Esrafili, A., & Abadi, R. H. H. B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.005 · Cited by 77
Opportunities and shortcomings of ionic liquids in single-drop microextraction
Marcinkowski, Ł., Pena-Pereira, F., Kloskowski, A., & Namieśnik, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.03.024 · Cited by 69
Bai, H., Zhou, Q., Xie, G., & Xiao, J. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.011 · Cited by 67
Liquid-Phase Microextraction in Bioanalytical Sample Preparation
Lucena, R., Cruz-Vera, M., Cárdenas, S., & Valcárcel, M. (2009) · Bioanalysis · doi:10.4155/bio.09.16 · Cited by 55
Li, Y., Hu, J., Liu, X., Fu, L., Zhang, X., & Wang, X. (2008) · Journal of Separation Science · doi:10.1002/jssc.200800112 · Cited by 49
Vickackaite, V., & Pusvaskiene, E. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900360 · Cited by 45
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Liquid phase microextraction techniques combined with chromatography analysis: a review
Dugheri, S., Mucci, N., Bonari, A., Marrubini, G., Cappelli, G., Ubiali, D., Campagna, M., Montalti, M., & Arcangeli, G. (2020) · Acta Chromatographica · doi:10.1556/1326.2019.00636 · Cited by 41
Sobhi, H. R., Yamini, Y., Esrafili, A., & Adib, M. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.07.029 · Cited by 39
Xu, H., Song, D., Cui, Y., Hu, S., Yu, Q.-W., & Feng, Y.-Q. (2009) · Chromatographia · doi:10.1365/s10337-009-1208-7 · Cited by 37
Zhou, Q., Zhang, X., Xie, G., & Xiao, J. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900444 · Cited by 33
Wang, X., Li, Y., Cai, F., Qing, Q., Yuan, K., Chen, B., & Luan, T. (2017) · Talanta · doi:10.1016/j.talanta.2016.06.011 · Cited by 30
Zichová, S., Brisudová, A., & Hrouzková, S. (2018) · Acta Chimica Slovaca · doi:10.2478/acs-2018-0010 · Cited by 5
Metadata
- Authors
- Jeannot, M. A., & Cantwell, F. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-01-01
- Volume
- 69
- Issue
- 2
- Pages
- 235-239
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1968534437
- Cited by
- 558
- References
- 4
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.