The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Highly Stretchable and Strain-Insensitive Fiber-Based Wearable Electrochemical Biosensor to Monitor Glucose in the Sweat
Open accessAbstract
Development of high-performance fiber-shaped wearable sensors is of great significance for next-generation smart textiles for real-time and out-of-clinic health monitoring. The previous focus has been mainly on monitoring physical parameters such as pressure and strains associated with human activities. Development of an enzyme-based non-invasive wearable electrochemical sensor to monitor biochemical vital signs of health such as the glucose level in sweat has attracted increasing attention recently, due to the unmet clinical needs for the diabetic patients. To achieve this, the key challenge lies in the design of a highly stretchable fiber with high conductivity, facile enzyme immobilization, and strain-insensitive properties. Herein, we demonstrate an elastic gold fiber-based three-electrode electrochemical platform that can meet the aforementioned criteria toward wearable textile glucose biosensing. The gold fiber could be functionalized with Prussian blue and glucose oxidase to obtain the working electrode and modified by Ag/AgCl to serve as the reference electrode; and the nonmodified gold fiber could serve as the counter electrode. The as-fabricated textile glucose biosensors achieved a linear range of 0–500 μM and a sensitivity of 11.7 μA mM –1 cm –2 . Importantly, such sensing performance could be maintained even under a large strain of 200%, indicating the potential applications in real-world wearable biochemical diagnostics from human sweat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Self-citationFiber‐Based Wearable Electronics: A Review of Materials, Fabrication, Devices, and Applications
Zeng, W., Shu, L., Li, Q., Chen, S., Wang, F., & Tao, X. (2014) · Advanced Materials · doi:10.1002/adma.201400633 · Cited by 2,019
Real surface area measurements in electrochemistry
Trasatti, S., & Petrii, O. A. (1991) · Pure and Applied Chemistry · doi:10.1351/pac199163050711 · Cited by 1,832
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Highly Skin‐Conformal Microhairy Sensor for Pulse Signal Amplification
Pang, C., Koo, J. H., Nguyen, A., Caves, J. M., Kim, M., Chortos, A., Kim, K., Wang, P. J., Tok, J. B. ‐., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201403807 · Cited by 734
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Heo, J. S., Eom, J., Kim, Y., & Park, S. K. (2018) · Small · doi:10.1002/smll.201703034 · Cited by 631
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Weng, W., Chen, P., He, S., Sun, X., & Peng, H. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201507333 · Cited by 577
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Energy harvesting and storage in 1D devices
Sun, H., Zhang, Y., Zhang, J., Sun, X., & Peng, H. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.23 · Cited by 528
A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis
Nyein, H. Y. Y., Tai, L.-C., Ngo, Q. P., Chao, M., Zhang, G. B., Gao, W., Bariya, M., Bullock, J., Kim, H., Fahad, H. M., et al. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00961 · Cited by 446
Skin-Attachable, Stretchable Electrochemical Sweat Sensor for Glucose and pH Detection
Oh, S. Y., Hong, S. Y., Jeong, Y. R., Yun, J., Park, H., Jin, S. W., Lee, G., Oh, J. H., Lee, H., Lee, S.-S., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b03342 · Cited by 440
Xuan, X., Yoon, H. S., & Park, J. Y. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.054 · Cited by 410
One‐Dimensional Nanomaterials for Soft Electronics
Gong, S., & Cheng, W. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600314 · Cited by 361
Self-citationWeaving Sensing Fibers into Electrochemical Fabric for Real‐Time Health Monitoring
Wang, L., Wang, L., Zhang, Y., Pan, J., Li, S., Sun, X., Zhang, B., & Peng, H. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201804456 · Cited by 353
Abellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.058 · Cited by 348
Thickness‐Gradient Films for High Gauge Factor Stretchable Strain Sensors
Liu, Z., Qi, D., Guo, P., Liu, Y., Zhu, B., Yang, H., Liu, Y., Li, B., Zhang, C., Yu, J., et al. (2015) · Advanced Materials · doi:10.1002/adma.201503288 · Cited by 344
Bandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
Stretchable biofuel cells as wearable textile-based self-powered sensors
Jeerapan, I., Sempionatto, J. R., Pavinatto, A., You, J.-M., & Wang, J. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta08358g · Cited by 317
Feng, H., Yang, Y., You, Y., Li, G., Guo, J., Yu, T., Shen, Z., Wu, T., & Xing, B. (2009) · Chemical Communications · doi:10.1039/b822507a · Cited by 271
Softening gold for elastronics
Zhu, B., Gong, S., & Cheng, W. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00609a · Cited by 216
Self-citationRecent progress in stretchable supercapacitors
An, T., & Cheng, W. (2018) · Journal of Materials Chemistry A · doi:10.1039/c8ta03988g · Cited by 214
Self-citationSuperelastic Hybrid CNT/Graphene Fibers for Wearable Energy Storage
Lu, Z., Foroughi, J., Wang, C., Long, H., & Wallace, G. G. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201702047 · Cited by 204
Standing Enokitake-like Nanowire Films for Highly Stretchable Elastronics
Wang, Y., Gong, S., Wang, S. J., Yang, X., Ling, Y., Yap, L. W., Dong, D., Simon, G. P., & Cheng, W. (2018) · ACS Nano · doi:10.1021/acsnano.8b05019 · Cited by 161
Self-citationChen, Y., Ouyang, Z., Gu, M., & Cheng, W. (2012) · Advanced Materials · doi:10.1002/adma.201202241 · Cited by 154
Self-citationStretchable Electrochemical Sensor for Real‐Time Monitoring of Cells and Tissues
Liu, Y., Jin, Z., Liu, Y., Hu, X., Qin, Y., Xu, J., Fan, C., & Huang, W. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201601276 · Cited by 125
Liu, Y., Qin, Y., Jin, Z., Hu, X., Chen, M., Liu, R., Amatore, C., & Huang, W. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201705215 · Cited by 89
Zhao, Y., Dong, D., Gong, S. P., Brassart, L., Wang, Y., An, T., & Cheng, W. (2018) · Advanced Electronic Materials · doi:10.1002/aelm.201800462 · Cited by 82
Self-citationVertical Gold Nanowires Stretchable Electrochemical Electrodes
Zhai, Q., Wang, Y., Gong, S. P., Ling, Y., Yap, L. W., Liu, Y., Wang, J., Simon, G. P., & Cheng, W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03423 · Cited by 79
Self-citationGong, S. P., Zhao, Y., Shi, Q., Wang, Y., Yap, L. W., & Cheng, W. (2016) · Electroanalysis · doi:10.1002/elan.201600081 · Cited by 78
Self-citationPoint-of-Care Diagnoses: Flexible Patterning Technique for Self-Powered Wearable Sensors
Zhang, X., Jing, Y., Zhai, Q., Yu, Y., Xing, H., Li, J., & Wang, E. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02838 · Cited by 59
Self-citationWang, Y., Liu, Y., Xu, J., Qin, Y., & Huang, W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01396 · Cited by 56
Zhao, Y., Dong, D., Wang, Y., Gong, S. P., An, T., Yap, L. W., & Cheng, W. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b14769 · Cited by 56
Self-citationSakaguchi, K., Hirota, Y., Hashimoto, N., Ogawa, W., Hamaguchi, T., Matsuo, T., Miyagawa, J.-I., Namba, M., Sato, T., Okada, S., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700313 · Cited by 50
Yu, Y., Zhai, J., Xia, Y., & Dong, S. (2017) · Nanoscale · doi:10.1039/c7nr04335j · Cited by 41
Jiang, D., Liu, Z., Wu, K., Mou, L., Ovalle‐Robles, R., Inoue, K., Zhang, Y., Yuan, N., Ding, J., Qiu, J., et al. (2018) · Polymers · doi:10.3390/polym10040375 · Cited by 17
Cited by
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 764
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Self-citationZheng, L., Zhu, M., Wu, B., Li, Z., Sun, S., & Wu, P. (2021) · Science Advances · doi:10.1126/sciadv.abg4041 · Cited by 367
Metadata
- Authors
- Zhao, Y., Zhai, Q., Dong, D., An, T., Gong, S., Shi, Q., & Cheng, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-04-22
- Volume
- 91
- Issue
- 10
- Pages
- 6569-6576
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2942057986
- Cited by
- 326
- References
- 46
- FWCI
- 12.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.