The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Optimization and Design of Magnetic Ferrite Nanoparticles with Uniform Tumor Distribution for Highly Sensitive MRI/MPI Performance and Improved Magnetic Hyperthermia Therapy
Abstract
Two major technical challenges of magnetic hyperthermia are quantitative assessment of agent distribution during and following administration and achieving uniform heating of the tumor at the desired temperature without damaging the surrounding tissues. In this study, we developed a multimodal MRI/MPI theranostic agent with active biological targeting for improved magnetic hyperthermia therapy (MHT). First, by systematically elucidating the magnetic nanoparticle magnetic characteristics and the magnetic resonance imaging (MRI) and magnetic particle imaging (MPI) signal enhancement effects, which are based on the magnetic anisotropy, size, and type of nanoparticles, we found that 18 nm iron oxide NPs (IOs) could be used as superior nanocrystallines for high performance of MRI/MPI contrast agents in vitro. To improve the delivery uniformity, we then targeted tumors with the 18 nm IOs using a tumor targeting peptide, CREKA. Both MRI and MPI signals showed that the targeting agent improves the intratumoral delivery uniformity of nanoparticles in a 4T1 orthotopic mouse breast cancer model. Lastly, the in vivo antitumor MHT effect was evaluated, and the data showed that the improved targeting and delivery uniformity enables more effective magnetic hyperthermia cancer ablation than otherwise identical, nontargeting IOs. This preclinical study of image-guided MHT using cancer-targeting IOs and a novel MPI system paves the way for new MHT strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic nanoparticles in MR imaging and drug delivery
Sun, C., Lee, J. S. H., & Zhang, M. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.018 · Cited by 2,594
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Artificially engineered magnetic nanoparticles for ultra-sensitive molecular imaging
Lee, J.-H., Huh, Y.-M., Jun, Y.-W., Seo, J.-W., Jang, J.-T., Song, H.-T., Kim, S., Cho, E.-J., Yoon, H.-G., Suh, J.-S., et al. (2007) · Nature Medicine · doi:10.1038/nm1467 · Cited by 1,897
Magnetic nanomaterials for hyperthermia-based therapy and controlled drug delivery
Kumar, C. S. S. R., & Mohammad, F. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.008 · Cited by 1,666
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Exchange-coupled magnetic nanoparticles for efficient heat induction
Lee, J.-H., Jang, J.-T., Choi, J.-S., Moon, S. H., Noh, S.-H., Kim, J.-W., Kim, J.-G., Kim, I.-S., Park, K. I., & Cheon, J. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.95 · Cited by 1,364
Size-Sorted Anionic Iron Oxide Nanomagnets as Colloidal Mediators for Magnetic Hyperthermia
Fortin, J.-P., Wilhelm, C., Servais, J., Ménager, C., Bacri, J.-C., & Gazeau, F. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067457e · Cited by 1,038
Magnetic nanoparticles for theragnostics
Shubayev, V. I., Pisanic, T. R., & Jin, S. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.03.007 · Cited by 1,028
Carrey, J., Mehdaoui, B., & Respaud, M. (2011) · Journal of Applied Physics · doi:10.1063/1.3551582 · Cited by 994
Theranostic Magnetic Nanoparticles
Yoo, D., Lee, J.-H., Shin, T.-H., & Cheon, J. (2011) · Accounts of Chemical Research · doi:10.1021/ar200085c · Cited by 730
Magnetically mediated hyperthermia: current status and future directions
Moroz, P., Jones, S. K., & Gray, B. N. (2002) · International Journal of Hyperthermia · doi:10.1080/02656730110108785 · Cited by 538
Chemical Synthesis and Assembly of Uniformly Sized Iron Oxide Nanoparticles for Medical Applications
Ling, D., Lee, N., & Hyeon, T. (2015) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00038 · Cited by 513
Zhu, J.-Y., Zheng, D.-W., Zhang, M.-K., Yu, W.-Y., Qiu, W.-X., Hu, J.-J., Feng, J., & Zhang, X.-Z. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b02786 · Cited by 498
Design of an Amphiphilic Polymer for Nanoparticle Coating and Functionalization
Lin, C. J., Sperling, R. A., Li, J. K., Yang, T., Li, P., Zanella, M., Chang, W. H., & Parak, W. J. (2008) · Small · doi:10.1002/smll.200700654 · Cited by 461
Magnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer Detection
Yu, E. Y., Bishop, M., Zheng, B., Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Krishnan, K. M., Goodwill, P. W., & Conolly, S. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b04865 · Cited by 366
Signal encoding in magnetic particle imaging: properties of the system function
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2009) · BMC Medical Imaging · doi:10.1186/1471-2342-9-4 · Cited by 345
Magnetic Nanomaterials: Chemical Design, Synthesis, and Potential Applications
Zhu, K., Ju, Y., Xu, J., Yang, Z., Gao, S., & Hou, Y. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00407 · Cited by 330
Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M. (2016) · Theranostics · doi:10.7150/thno.13728 · Cited by 322
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.029 · Cited by 307
Zheng, B., Vazin, T., Goodwill, P. W., Conway, A., Verma, A., Ulku Saritas, E., Schaffer, D., & Conolly, S. M. (2015) · Scientific Reports · doi:10.1038/srep14055 · Cited by 274
Kossatz, S., Grandke, J., Couleaud, P., Latorre, A., Aires, A., Crosbie-Staunton, K., Ludwig, R., Dähring, H., Ettelt, V., Lazaro-Carrillo, A., et al. (2015) · Breast Cancer Research · doi:10.1186/s13058-015-0576-1 · Cited by 272
MRI detection of breast cancer micrometastases with a fibronectin-targeting contrast agent
Zhou, Z., Qutaish, M., Han, Z., Schur, R. M., Liu, Y., Wilson, D. L., & Lu, Z.-R. (2015) · Nature Communications · doi:10.1038/ncomms8984 · Cited by 260
Liu, X. L., Fan, H. M., Yi, J. B., Yang, Y., Choo, E. S. G., Xue, J. M., Fan, D. D., & Ding, J. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm30472d · Cited by 247
Self-citationIron Oxide-Based Nanostructures for MRI and Magnetic Hyperthermia
Hilger, I., & Kaiser, W. A. (2012) · Nanomedicine · doi:10.2217/nnm.12.112 · Cited by 243
Zhang, H., Li, L., Liu, X. L., Jiao, J., Ng, C.-T., Yi, J. B., Luo, Y. E., Bay, B.-H., Zhao, L. Y., Peng, M. L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b07684 · Cited by 224
Self-citationMagnetic Particle Imaging for Real-Time Perfusion Imaging in Acute Stroke
Ludewig, P., Gdaniec, N., Sedlacik, J., Forkert, N. D., Szwargulski, P., Graeser, M., Adam, G., Kaul, M. G., Krishnan, K. M., Ferguson, R. M., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b05784 · Cited by 224
T1 and T2 Dual-Mode MRI Contrast Agent for Enhancing Accuracy by Engineered Nanomaterials
Shin, T.-H., Choi, J.-S., Yun, S., Kim, I.-S., Song, H.-T., Kim, Y., Park, K. I., & Cheon, J. (2014) · ACS Nano · doi:10.1021/nn405977t · Cited by 209
Liu, X. L., Yang, Y., Ng, C. T., Zhao, L. Y., Zhang, Y., Bay, B. H., Fan, H. M., & Ding, J. (2015) · Advanced Materials · doi:10.1002/adma.201405036 · Cited by 209
Self-citationYu, E. Y., Chandrasekharan, P., Berzon, R., Tay, Z. W., Zhou, X. Y., Khandhar, A. P., Ferguson, R. M., Kemp, S. J., Zheng, B., Goodwill, P. W., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b04844 · Cited by 161
Magnetic particle imaging: visualization of instruments for cardiovascular intervention
Haegele, J., Rahmer, J., Gleich, B., Borgert, J., Wojtczyk, H., Panagiotopoulos, N., Buzug, T. M., Barkhausen, J., & Vogt, F. M. (2012) · Radiology · doi:10.1148/radiol.12120424 · Cited by 151
Fan, H., Olivo, M., Shuter, B., Yi, J., Ramaswamy, B., Tan, H., Xing, G., Ng, C.-T., Liu, L., Lucky, S. S., et al. (2010) · Journal of the American Chemical Society · doi:10.1021/ja103738t · Cited by 150
Graeser, M., Knopp, T., Szwargulski, P., Friedrich, T., von Gladiss, A., Kaul, M. G., Krishnan, K. M., Ittrich, H., Adam, G., & Buzug, T. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-06992-5 · Cited by 144
First in vivo magnetic particle imaging of lung perfusion in rats
Zhou, X. Y., Jeffris, K. E., Yu, E. Y., Zheng, B., Goodwill, P. W., Nahid, P., & Conolly, S. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa616c · Cited by 128
System Characterization of a Highly Integrated Preclinical Hybrid MPI-MRI Scanner
Franke, J., Heinen, U., Lehr, H., Weber, A., Jaspard, F., Ruhm, W., Heidenreich, M., & Schulz, V. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2542041 · Cited by 110
Knopp, T., Biederer, S., Sattel, T. F., Erbe, M., & Buzug, T. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2113188 · Cited by 105
Salamon, J., Hofmann, M., Jung, C., Kaul, M. G., Werner, F., Them, K., Reimer, R., Nielsen, P., Scheidt, A. V., Adam, G., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0156899 · Cited by 104
La-Beck, N. M., & Gabizón, A. (2017) · Frontiers in Immunology · doi:10.3389/fimmu.2017.00416 · Cited by 99
Magnetic nanoparticles based cancer therapy: current status and applications
Zhang, H., Liu, X., Zhang, Y. F., Gao, F., Li, G., He, Y., Peng, M., & Fan, H. M. (2018) · Science China Life Sciences · doi:10.1007/s11427-017-9271-1 · Cited by 95
Self-citationRahmer, J., Wirtz, D., Bontus, C., Borgert, J., & Gleich, B. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2679099 · Cited by 92
Tay, Z. W., Goodwill, P. W., Hensley, D. W., Taylor, L. A., Zheng, B., & Conolly, S. (2016) · Scientific Reports · doi:10.1038/srep34180 · Cited by 86
Xue, W., Liu, X., Ma, H., Xie, W., Huang, S., Wen, H., Jing, G., Zhao, L., Liang, X., & Fan, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c7tb03206d · Cited by 84
Self-citationBiomaterials-Based Modulation of the Immune System
Gardner, A. B., Lee, S. K. C., Woods, E. C., & Acharya, A. P. (2013) · BioMed Research International · doi:10.1155/2013/732182 · Cited by 81
Sensitivity Enhancement in Magnetic Particle Imaging by Background Subtraction
Them, K., Kaul, M. G., Jung, C., Hofmann, M., Mummert, T., Werner, F., & Knopp, T. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2501462 · Cited by 80
Huang, J., Wang, L., Zhong, X., Li, Y., Yang, L. P. H., & Mao, H. Z. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00811a · Cited by 76
Them, K., Salamon, J., Szwargulski, P., Sequeira, S., Kaul, M. G., Lange, C., Ittrich, H., & Knopp, T. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/9/3279 · Cited by 62
Liu, X., & Fan, H. M. (2014) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2013.12.010 · Cited by 57
Self-citationEffect of different magnetic nanoparticle coatings on the efficiency of stem cell labeling
Horák, D., Babič, M., Jendelová, P., et al. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.082 · Cited by 56
Liu, X., Wang, Y. T., Ng, C.-T., Wang, R., Jing, G., Yi, J. B., Yang, J. Y., Bay, B., Yung, L. L., Fan, D. D., et al. (2014) · Advanced Materials Interfaces · doi:10.1002/admi.201300069 · Cited by 48
Self-citationSuperspeed Traveling Wave Magnetic Particle Imaging
Vogel, P., Rückert, M. A., Klauer, P., Kullmann, W., Jakob, P. M., & Behr, V. C. (2015) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2322897 · Cited by 30
Stem Cell Vitality Assessment Using Magnetic Particle Spectroscopy
Fidler, F., Steinke, M. R., Kraupner, A., Grüttner, C., Hiller, K., Briel, A., Westphal, F., Walles, H., & Jakob, P. M. (2015) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2337052 · Cited by 29
Cited by
Engineering precision nanoparticles for drug delivery
Mitchell, M. J., Billingsley, M. M., Haley, R. M., Wechsler, M. E., Peppas, N. A., & Langer, R. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0090-8 · Cited by 7,933
Comprehensive understanding of magnetic hyperthermia for improving antitumor therapeutic efficacy
Liu, X., Zhang, Y., Wang, Y., Zhu, W., Li, G., Ma, X., Zhang, Y., Chen, S., Tiwari, S., Shi, K., et al. (2020) · Theranostics · doi:10.7150/thno.40805 · Cited by 719
Self-citationRezaei, B., Yari, P., Sanders, S. M., Wang, H., Chugh, V. K., Liang, S., Mostufa, S., Xu, K., Wang, J., Gómez‐Pastora, J., et al. (2024) · Small · doi:10.1002/smll.202304848 · Cited by 366
Recent progress of magnetic nanoparticles in biomedical applications: A review
Anik, M. I., Hossain, M. K., Hossain, I., Mahfuz, A. M. U. B., Rahman, M. T., & Ahmed, I. (2021) · Nano Select · doi:10.1002/nano.202000162 · Cited by 300
Stimuli‐Responsive Nanoparticles for Controlled Drug Delivery in Synergistic Cancer Immunotherapy
Zhang, J., Lin, Y., Lin, Z., Wei, Q., Qian, J., Ruan, R., Jiang, X., Hou, L., Song, J., Ding, J., et al. (2022) · Advanced Science · doi:10.1002/advs.202103444 · Cited by 292
Metadata
- Authors
- Du, Y., Liu, X., Liang, Q., Liang, X.-J., & Tian, J.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-05-10
- Volume
- 19
- Issue
- 6
- Pages
- 3618-3626
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2944326691
- Cited by
- 260
- References
- 50
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.