CoChat

Renal-Clearable Probe with Water Solubility and Photostability for Biomarker-Activatable Detection of Acute Kidney Injuries via NIR-II Fluorescence and Optoacoustic Imaging

Zeng, Cheng, Tan, Yunyan, Sun, Lihe, Long, Yi, Zeng, Fang, Wu, Shuizhu · 2023 · ACS Applied Materials & Interfaces
Cited by 65

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Acute kidney injuries (AKI) have serious short-term or long-term complications with high morbidity and mortality rate, thus posing great health threats. Developing high-performance NIR-II probes for noninvasive in situ detection of AKI via NIR-II fluorescent and optoacoustic dual-mode imaging is of great significance. Yet NIR-II chromophores often feature long conjugation and hydrophobicity, which prevent them from being renal clearable, thus limiting their applications in the detection and imaging of kidney diseases. To fully exploit the advantageous features of heptamethine cyanine dye, while overcoming its relatively poor photostability, and to strive to design a NIR-II probe for the detection and imaging of AKI with dual-mode imaging, herein, we have developed the probe PEG3-HC-PB, which is renal clearable, water soluble, and biomarker activatable and has good photostability. As for the probe, its fluorescence (900–1200 nm) is quenched due to the existence of the electron-pulling phenylboronic group (responsive element), and it exhibits weak absorption with a peak at 830 nm. Meanwhile, in the presence of the overexpressed H 2 O 2 in the renal region in the case of AKI, the phenylboronic group is converted to the phenylhydroxy group, which enhances NIR-II fluorescent emission (900–1200 nm) and absorption (600–900 nm) and eventually produces conspicuous optoacoustic signals and NIR-II fluorescent emission for imaging. This probe enables detection of contrast-agent-induced and ischemia/reperfusion-induced AKI in mice using real-time 3D-MSOT and NIR-II fluorescent dual-mode imaging via response to the biomarker H 2 O 2 . Hence, this probe can be used as a practicable tool for detecting AKI; additionally, its design strategy could provide insight into the design of other large-conjugation NIR-II probes with multifarious biological applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.3c00956

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

Metadata

Authors
Zeng, C., Tan, Y., Sun, L., Long, Y., Zeng, F., & Wu, S.
Venue
ACS Applied Materials & Interfaces
Published
2023-04-03
Volume
15
Issue
14
Pages
17664-17674
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W4362523374
Cited by
65
References
12
FWCI
5.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.