The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Are Quantum Dots Toxic? Exploring the Discrepancy Between Cell Culture and Animal Studies
Abstract
Despite significant interest in developing quantum dots (QDs) for biomedical applications, many researchers are convinced that QDs will never be used for treating patients because of their potential toxicity. The perception that QDs are toxic is rooted in two assumptions. Cadmium-containing QDs can kill cells in culture. Many researchers then assume that because QDs are toxic to cells, they must be toxic to humans. In addition, many researchers classify QDs as a homogeneous group of materials. Therefore, if CdSe QDs are harmful, they extrapolate this result to all QDs. Though unsubstantiated, these assumptions continue to drive QD research. When dosing is physiologically appropriate, QD toxicity has not been demonstrated in animal models. In addition, QDs are not uniform: each design is a unique combination of physicochemical properties that influence biological activity and toxicity. In this Account, we summarize key findings from in vitro and in vivo studies, explore the causes of the discrepancy in QD toxicological data, and provide our view of the future direction of the field. In vitro and in vivo QD studies have advanced our knowledge of cellular transport kinetics, mechanisms of QD toxicity, and biodistribution following animal injection. Cell culture experiments have shown that QDs undergo design-dependent intracellular localization and they can cause cytotoxicity by releasing free cadmium into solution and by generating free radical species. In animal experiments, QDs preferentially enter the liver and spleen following intravascular injection, undergo minimal excretion if larger than 6 nm, and appear to be safe to the animal. In vitro and in vivo studies show an apparent discrepancy with regard to toxicity. Dosing provides one explanation for these findings. Under culture conditions, a cell experiences a constant QD dose, but the in vivo QD concentration can vary, and the organ-specific dose may not be high enough to induce detectable toxicity. Because QDs are retained within animals, long-term toxicity may be a problem but has not been established. Future QD toxicity studies should be standardized and systematized because methodological variability in the current body of literature makes it difficult to compare and contrast results. We advocate the following steps for consistent, comparable toxicology data: (a) standardize dose metrics, (b) characterize QD uptake concentration, (c) identify in vitro models that reflect the cells QDs interact with in vivo, and (d) use multiple assays to determine sublethal toxicity and biocompatibility. Finally, we should ask more specific toxicological questions. For example: "At what dose are 5 nm CdSe QDs that are stabilized with mercaptoacetic acid and conjugated to the antibody herceptin toxic to HeLa cells?" rather than "Are QDs toxic?" QDs are still a long way from realizing their potential as a medical technology. Modifying the current QD toxicological research paradigm, investigating toxicity in a case-by-case manner, and improving study quality are important steps in identifying a QD formulation that is safe for human use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Walkey, C. D., & Chan, W. C. W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15233e · Cited by 1,758
Self-citationOops they did it again! Carbon nanotubes hoax scientists in viability assays
Wörle-Knirsch, J. M., Pulskamp, K., & Krug, H. F. (2006) · Nano Letters · doi:10.1021/nl060177c · Cited by 994
O’Brien, P. J., Irwin, W., Diaz, D., Howard-Cofield, E., Krejsa, C. M., Slaughter, M. R., Gao, B., Kaludercic, N., Angeline, A., Bernardi, P., et al. (2006) · Archives of Toxicology · doi:10.1007/s00204-006-0091-3 · Cited by 609
Cited by
Dependence of Nanoparticle Toxicity on Their Physical and Chemical Properties
Sukhanova, A., Bozrova, S., Sokolov, P., Berestovoy, M., Karaulov, A., & Nabiev, I. (2018) · Nanoscale Research Letters · doi:10.1186/s11671-018-2457-x · Cited by 1,107
Hildebrandt, N., Spillmann, C. M., Algar, W. R., Pons, T., Stewart, M. H., Oh, E., Susumu, K., Díaz, S. A., Delehanty, J. B., & Medintz, I. L. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00030 · Cited by 730
Bao, X., Zhao, J., Sun, J., Hu, M., & Yang, X. (2018) · ACS Nano · doi:10.1021/acsnano.8b04022 · Cited by 722
New Generation Cadmium-Free Quantum Dots for Biophotonics and Nanomedicine
Xu, G., Zeng, S., Zhang, B., Swihart, M. T., Yong, K.-T., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00290 · Cited by 587
Soenen, S. J., Parak, W. J., Rejman, J., & Manshian, B. (2015) · Chemical Reviews · doi:10.1021/cr400714j · Cited by 515
A Review of Clinical Translation of Inorganic Nanoparticles
Anselmo, A. C., & Mitragotri, S. (2015) · The AAPS Journal · doi:10.1208/s12248-015-9780-2 · Cited by 509
Meta-analysis of cellular toxicity for cadmium-containing quantum dots
Oh, E., Liu, R., Nel, A., Gemill, K. B., Bilal, M., Cohen, Y., & Medintz, I. L. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.338 · Cited by 502
Biodistribution, Clearance, and Long‐Term Fate of Clinically Relevant Nanomaterials
Bourquin, J., Milosevic, A., Hauser, D., Lehner, R., Blank, F., Petri‐Fink, A., & Rothen‐Rutishauser, B. (2018) · Advanced Materials · doi:10.1002/adma.201704307 · Cited by 461
Versatile Types of Organic/Inorganic Nanohybrids: From Strategic Design to Biomedical Applications
Zhao, N., Yan, L., Zhao, X., Chen, X., Li, A., Zheng, D., Zhou, X., Dai, X., & Xu, F.-J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00401 · Cited by 429
Application of semiconductor quantum dots in bioimaging and biosensing
Martynenko, I. V., Litvin, A. P., Purcell-Milton, F., Baranov, A. V., Fedorov, A. V., & Gun'ko, Y. K. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01425b · Cited by 382
Inorganic nanoparticles in clinical trials and translations
Huang, H., Feng, W., Chen, Y., & Shi, J. (2020) · Nano Today · doi:10.1016/j.nantod.2020.100972 · Cited by 283
Montalti, M., Cantelli, A., & Battistelli, G. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00486h · Cited by 265
Liu, H.-Y., Wu, P.-J., Kuo, S.-Y., Chen, C.-P., Chang, E.-H., Wu, C.-Y., & Chan, Y.-H. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b06710 · Cited by 181
Magnetic Nanostructures: Rational Design and Fabrication Strategies toward Diverse Applications
Wang, S., Xu, J., Li, W., Sun, S., Gao, S., & Hou, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00370 · Cited by 129
Two-Photon Absorption: An Open Door to the NIR-II Biological Window?
Shaw, P. A., Forsyth, E., Haseeb, F., Yang, S., Bradley, M., & Klausen, M. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.921354 · Cited by 75
Metadata
- Authors
- Tsoi, K. M., Dai, Q., Alman, B. A., & Chan, W. C. W.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-08-01
- Volume
- 46
- Issue
- 3
- Pages
- 662-671
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2057005337
- Cited by
- 420
- References
- 4
- FWCI
- 12.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.