Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Experimental conditions in the continuous DIB device promote rapid transport equilibration between droplet compartments due to the inherent recirculating flow found in droplets.28,29”
From Chiral lipid bilayers are enantioselectively permeable (2021) · doi:10.1038/s41557-021-00708-z · cites this paper as [28]
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationRaines, R. T. (1998) · Chemical Reviews · doi:10.1021/cr960427h · Cited by 937
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Leach, C. L., Greenspan, J. S., Rubenstein, S. D., Shaffer, T. H., Wolfson, M. R., Jackson, J. C., DeLemos, R., & Fuhrman, B. P. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609123351101 · Cited by 453
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
Self-citationMathematics handbook for science and engineering
(1996) · Choice Reviews Online · doi:10.5860/choice.33-4559 · Cited by 390
Phosphorylation and Activation of 13 S Condensin by Cdc2 in Vitro
Kimura, K., Hirano, M., Kobayashi, R., & Hirano, T. (1998) · Science · doi:10.1126/science.282.5388.487 · Cited by 378
Nonequilibrium Self-Assembly of Long Chains of Polar Molecules in Superfluid Helium
Nauta, K., & Miller, R. E. (1999) · Science · doi:10.1126/science.283.5409.1895 · Cited by 359
Vesicles and Polymerized Vesicles from Thiophene‐Containing Rod–Coil Block Copolymers
Vriezema, D. M., Hoogboom, J., Velonia, K., Takazawa, K., Christianen, P. C. M., Maan, J. C., Rowan, A. E., & Nolte, R. J. M. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390204 · Cited by 334
Pollack, L., Tate, M. W., Darnton, N. C., Knight, J. B., Gruner, S. M., Eaton, W. A., & Austin, R. H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10115 · Cited by 285
A simple test for inactivation of an enzyme during assay
Selwyn, M. J. (1965) · Biochimica et Biophysica Acta (BBA) - Enzymology and Biological Oxidation · doi:10.1016/s0926-6593(65)80190-4 · Cited by 253
Valentine, A. M., Stahl, S. S., & Lippard, S. J. (1999) · Journal of the American Chemical Society · doi:10.1021/ja9839522 · Cited by 248
Submillisecond protein folding kinetics studied by ultrarapid mixing
Chan, C.-K., Hu, Y., Takahashi, S., Rousseau, D. L., Eaton, W. A., & Hofrichter, J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.5.1779 · Cited by 248
Kinetic Measurement of the Step Size of DNA Unwinding by Escherichia coli UvrD Helicase
Ali, J. A., & Lohman, T. M. (1997) · Science · doi:10.1126/science.275.5298.377 · Cited by 244
Design and Characterization of Immobilized Enzymes in Microfluidic Systems
Mao, H., Yang, T., & Cremer, P. S. (2002) · Analytical Chemistry · doi:10.1021/ac010822u · Cited by 235
Chemical Transformations in Individual Ultrasmall Biomimetic Containers
Chiu, D. T., Wilson, C. F., Ryttsén, F., Strömberg, A., Farre, C., Karlsson, A., Nordholm, S., Gaggar, A., Modi, B. P., Moscho, A., et al. (1999) · Science · doi:10.1126/science.283.5409.1892 · Cited by 228
Rapid compaction during RNA folding
Russell, R., Millett, I. S., Tate, M. W., Kwok, L. W., Nakatani, B., Gruner, S. M., Mochrie, S. G. J., Pande, V., Doniach, S., Herschlag, D., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.072589599 · Cited by 220
A Continuous-Flow Capillary Mixing Method to Monitor Reactions on the Microsecond Time Scale
Shastry, M. C. R., Luck, S. D., & Roder, H. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77977-9 · Cited by 216
Hypersensitive substrate for ribonucleases
Kelemen, B. R., Klink, T. A., Behike, M. A., Eubanks, S. R., Leland, P. A., & Raines, R. T. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.18.3696 · Cited by 194
Time Resolved Collapse of a Folding Protein Observed with Small Angle X-Ray Scattering
Pollack, L., Tate, M. W., Finnefrock, A. C., Kalidas, C., Trotter, S., Darnton, N. C., Lurio, L., Austin, R. H., Batt, C. A., Gruner, S. M., et al. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4962 · Cited by 164
A Miniaturized, Parallel, Serially Diluted Immunoassay for Analyzing Multiple Antigens
Jiang, X., Ng, J. M. K., Stroock, A. D., Dertinger, S. K. W., & Whitesides, G. M. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034566+ · Cited by 160
Squires, J. E. (2002) · Science · doi:10.1126/science.1068443 · Cited by 159
Development of a Microreactor for Chemical Production
Burns, J. R., & Ramshaw, C. (1999) · Process Safety and Environmental Protection · doi:10.1205/026387699526106 · Cited by 155
A Microreactor for the Nitration of Benzene and Toluene
Burns, J. R., & Ramshaw, C. (2002) · Chemical Engineering Communications · doi:10.1080/00986440214585 · Cited by 137
Distinguishing between Two-State and Three-State Models for Ubiquitin Folding
Krantz, B. A., & Sosnick, T. R. (2000) · Biochemistry · doi:10.1021/bi000792+ · Cited by 130
Value of General Acid-Base Catalysis to Ribonuclease A
Thompson, J. E., & Raines, R. T. (1994) · Journal of the American Chemical Society · doi:10.1021/ja00091a060 · Cited by 130
A numerical model for segmented flow in a microreactor
Harries, N., Burns, J. R., Barrow, D. A., & Ramshaw, C. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00120-0 · Cited by 127
Cherry, J.-P. F., Johnson, A. R., Baraldo, L. M., Tsai, Y., Cummins, C. C., Kryatov, S. V., Rybak-Akimova, E. V., Capps, K. B., Hoff, C. D., Haar, C. M., et al. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0031063 · Cited by 125
Advances in Proteomic Technologies
Yarmush, M. L., & Jayaraman, A. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153443 · Cited by 113
Micromixer-Based Time-Resolved NMR: Applications to Ubiquitin Protein Conformation
Kakuta, M., Jayawickrama, D. A., Wolters, A. M., Manz, A., & Sweedler, J. V. (2003) · Analytical Chemistry · doi:10.1021/ac026076q · Cited by 93
Brazeau, B. J., Austin, R. N., Tarr, C., Groves, J. T., & Lipscomb, J. D. (2001) · Journal of the American Chemical Society · doi:10.1021/ja016376+ · Cited by 90
Autocatalytic processes in mixing flows
Metcalfe, G., & Ottino, J. M. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.2875 · Cited by 89
[1] Transient kinetic approaches to enzyme mechanisms
Fierke, C. A., & Hammes, G. G. (1995) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(95)49029-9 · Cited by 87
The rate-limiting step in the folding of a large ribozyme without kinetic traps
Fang, X.-W., Thiyagarajan, P., Sosnick, T. R., & Pan, T. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.142288399 · Cited by 76
Substrate Recognition and Selection by the Initiation Module PheATE of Gramicidin S Synthetase
Luo, L., Burkart, M. D., Stachelhaus, T., & Walsh, C. T. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0166646 · Cited by 55
Product Review: Flow injection Analysis; Quietly Pushing Ahead
Smith, J. P., & Hinson-Smith, V. (2002) · Analytical Chemistry · doi:10.1021/ac022064t · Cited by 50
Breakdown of Ovchinnikov-Zeldovich Segregation in the A+B→0 Reaction under Lévy Mixing
Zumofen, G., Klafter, J., & Shlesinger, M. F. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2830 · Cited by 47
A fluorogenic assay using pressure-driven flow on a microchip
Kerby, M. B., & Chien, R. (2001) · Electrophoresis · Cited by 33
Single-Turnover Kinetics of Saccharomyces cerevisiae Inorganic Pyrophosphatase
Halonen, P., Baykov, A. A., Goldman, A., Lahti, R., & Cooperman, B. S. (2002) · Biochemistry · doi:10.1021/bi026018z · Cited by 23
Nemoda, Z., Rónai, Z., Szekely, A., Kovács, E. R., Shandrick, S., Guttman, A., & Sasvári‐Székely, M. (2001) · Electrophoresis · doi:10.1002/1522-2683(200110)22:18<4023::aid-elps4023>3.0.co;2-p · Cited by 14
Confining and Probing Single Molecules in Synthetic Liposomes
Wilson, C. F., Chiu, D. T., Zare, R. N., Strömberg, A., Karlsson, A., & Orwar, O. (2001) · Springer series in chemical physics · doi:10.1007/978-3-642-56544-1_7 · Cited by 1
Research works printed but not linked: 19
- Shastry M. C. R., 1998, Biophys. J., 74, 2721
- Tice J. D., 2003, Langmuir, 19, 9133
- Chan C. K., 1997, Proc. Natl. Acad. Sci. U.S.A., 94, 1784
- Fang X. W., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 8523
- Ali J. A., 1997, Science, 275, 380
- Luo L. S., 2001, J. Am. Chem. Soc., 123, 11218
- Brazeau B. J., 2001, J. Am. Chem. Soc., 123, 11837
- Nelsen S. F., 1997, J. Am. Chem. Soc., 119, 5907
- Cherry J. P. F., 2001, J. Am. Chem. Soc., 123, 7286
- Kerby M., 2001, Electrophoresis, 22, 3923, 10.1002/1522-2683(200110)22:18<3916::AID-ELPS3916>3.0.CO;2-V · doi:10.1002/1522-2683(200110)22:18<3916::aid-elps3916>3.0.co;2-v
- Russell R., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 4271
- Jiang X. Y., 2003, J. Am. Chem. Soc., 125, 5295
- Wilson C. F., 2001, Single Molecule Spectroscopy: Nobel Symposium Lectures, 143
- Duggleby R., 1995, Enzyme Kinetics and Mechanism, Pt D, 249, 90
- Selwyn M., 1965, J. Biochim. Biophys. Acta, 105, 195
- Thompson J. E., 1994, J. Am. Chem. Soc., 116, 5468
- Witzel H., 1963, Prog. Nucleic Acid Res., 2, 258
- Haykin S., 1994, Neural Networks
- Song H., 2003, Appl. Phys. Lett.
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
“A sedimenting drop in a shear flow Bryden and Brenner, 1999 , a drop driven along a turning microchannel Song, Bringer, et al., 2003; Song and Ismagilov, 2003; Song, Tice, et al., 2003; Tice et al., 2003; Bringer et al., 2004 , and oscillating drops Angilella and Brancher, 2003 all can exhibit…”
BackgroundTeh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Self-citation
Metadata
- Authors
- Song, H., & Ismagilov, R. F.
- Affiliations
- University of Chicago (US)
- ORCID
- Ismagilov, Rustem F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-29
- Volume
- 125
- Issue
- 47
- Pages
- 14613-14619
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- PMC
- PMC1769313
- OpenAlex
- W2028894110
- Cited by
- 693
- References
- 45
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 14 · 2023: 16 · 2022: 18 · 2021: 29 · 2020: 17 · 2019: 26 · 2018: 30 · 2017: 22 · 2016: 28 · 2015: 29 · 2014: 38 · 2013: 48 · 2012: 55
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institute of General Medical Sciences (GM08720, T32GM008720)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001903)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- droplet microfluidics, single-turnover kinetics, ribonuclease A, enzyme kinetics, chaotic advection, rapid mixing, PDMS microfluidic device, fluorescence imaging
- MeSH terms
- Biocompatible Materials, Kinetics, Microchemistry, Ribonuclease, Pancreatic, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.