Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Experimental conditions in the continuous DIB device promote rapid transport equilibration between droplet compartments due to the inherent recirculating flow found in droplets.28,29”
From Chiral lipid bilayers are enantioselectively permeable (2021) · doi:10.1038/s41557-021-00708-z · cites this paper as [28]
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationRaines, R. T. (1998) · Chemical Reviews · doi:10.1021/cr960427h · Cited by 937
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Leach, C. L., Greenspan, J. S., Rubenstein, S. D., Shaffer, T. H., Wolfson, M. R., Jackson, J. C., DeLemos, R., & Fuhrman, B. P. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609123351101 · Cited by 453
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
Self-citation
Research works printed but not linked: 19
- Shastry M. C. R., 1998, Biophys. J., 74, 2721
- Tice J. D., 2003, Langmuir, 19, 9133
- Chan C. K., 1997, Proc. Natl. Acad. Sci. U.S.A., 94, 1784
- Fang X. W., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 8523
- Ali J. A., 1997, Science, 275, 380
- Luo L. S., 2001, J. Am. Chem. Soc., 123, 11218
- Brazeau B. J., 2001, J. Am. Chem. Soc., 123, 11837
- Nelsen S. F., 1997, J. Am. Chem. Soc., 119, 5907
- Cherry J. P. F., 2001, J. Am. Chem. Soc., 123, 7286
- Kerby M., 2001, Electrophoresis, 22, 3923, 10.1002/1522-2683(200110)22:18<3916::AID-ELPS3916>3.0.CO;2-V · doi:10.1002/1522-2683(200110)22:18<3916::aid-elps3916>3.0.co;2-v
- Russell R., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 4271
- Jiang X. Y., 2003, J. Am. Chem. Soc., 125, 5295
- Wilson C. F., 2001, Single Molecule Spectroscopy: Nobel Symposium Lectures, 143
- Duggleby R., 1995, Enzyme Kinetics and Mechanism, Pt D, 249, 90
- Selwyn M., 1965, J. Biochim. Biophys. Acta, 105, 195
- Thompson J. E., 1994, J. Am. Chem. Soc., 116, 5468
- Witzel H., 1963, Prog. Nucleic Acid Res., 2, 258
- Haykin S., 1994, Neural Networks
- Song H., 2003, Appl. Phys. Lett.
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
“A sedimenting drop in a shear flow Bryden and Brenner, 1999 , a drop driven along a turning microchannel Song, Bringer, et al., 2003; Song and Ismagilov, 2003; Song, Tice, et al., 2003; Tice et al., 2003; Bringer et al., 2004 , and oscillating drops Angilella and Brancher, 2003 all can exhibit…”
BackgroundTeh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Self-citationMicrofluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
“Such features, combined with the ability to combine, split and sort droplets, are likely to transform the application of microfluidic systems, and suggest that they would be of use in high-throughput synthesis (due to high sample throughput) and kinetic measurements (due to low sample requirements and negligible dispe…”
BackgroundMicrofluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
“[354, 355], scaling laws of the chaotic advection [356], and”
BackgroundControlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
“That is, a given position in the channel will correspond to the same kinetic state, so signals can be collected from several successive droplets and integrated to improve the signal-to-noise ratio, making it possible to monitor even relatively fast reactions with millisecond time resolution or bette”
BackgroundDeciding Whether To Go with the Flow: Evaluating the Merits of Flow Reactors for Synthesis
Hartman, R. L., McMullen, J. P., & Jensen, K. F. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201004637 · Cited by 999
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Transition from squeezing to dripping in a microfluidic T-shaped junction
DE MENECH, M., GARSTECKI, P., JOUSSE, F., & STONE, H. A. (2008) · Journal of Fluid Mechanics · doi:10.1017/s002211200700910x · Cited by 728
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Formation of monodisperse bubbles in a microfluidic flow-focusing device
Garstecki, P., Gitlin, I., DiLuzio, W., Whitesides, G. M., Kumacheva, E., & Stone, H. A. (2004) · Applied Physics Letters · doi:10.1063/1.1796526 · Cited by 641
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Shestopalov, I., Tice, J. D., & Ismagilov, R. F. (2004) · Lab on a Chip · doi:10.1039/b403378g · Cited by 571
Self-citationDroplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
The role of flow in green chemistry and engineering
Newman, S. G., & Jensen, K. F. (2013) · Green Chemistry · doi:10.1039/c3gc40374b · Cited by 550
Micromixing Within Microfluidic Devices
Capretto, L., Cheng, W., Hill, M., & Zhang, X. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_150 · Cited by 448
“,<1%) [53, 137–140].”
Mixing in microfluidic devices and enhancement methods
Ward, K., & Fan, Z. H. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/9/094001 · Cited by 453
Flash chemistry: flow chemistry that cannot be done in batch
Yoshida, J.-I., Takahashi, Y., & Nagaki, A. (2013) · Chem. Commun. · doi:10.1039/c3cc44709j · Cited by 450
Green and Sustainable Chemical Synthesis Using Flow Microreactors
Yoshida, J., Kim, H., & Nagaki, A. (2011) · ChemSusChem · doi:10.1002/cssc.201000271 · Cited by 442
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Girod, M., Moyano, E., Campbell, D. I., & Cooks, R. G. (2011) · Chem. Sci. · doi:10.1039/c0sc00416b · Cited by 419
Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets
Bringer, M. R., Gerdts, C. J., Song, H., Tice, J. D., & Ismagilov, R. F. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1364 · Cited by 416
Self-citationA millisecond micromixer via single-bubble-based acoustic streaming
Ahmed, D., Mao, X., Shi, J., Juluri, B. K., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b903687c · Cited by 415
Gas–liquid and liquid–liquid mass transfer in microstructured reactors
Kashid, M. N., Renken, A., & Kiwi-Minsker, L. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2011.05.015 · Cited by 388
Microfluidics: Innovations in Materials and Their Fabrication and Functionalization
Nielsen, J. B., Hanson, R. L., Almughamsi, H. M., Pang, C., Fish, T. R., & Woolley, A. T. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04986 · Cited by 359
Analytical detection techniques for droplet microfluidics—A review
Zhu, Y., & Fang, Q. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.064 · Cited by 365
Flow-induced deformation of shallow microfluidic channels
Gervais, T., El-Ali, J., Günther, A., & Jensen, K. F. (2006) · Lab on a Chip · doi:10.1039/b513524a · Cited by 359
Effects of viscosity on droplet formation and mixing in microfluidic channels
Tice, J. D., Lyon, A. D., & Ismagilov, R. F. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.11.024 · Cited by 360
Self-citationIntegrated Microreactors for Reaction Automation: New Approaches to Reaction Development
McMullen, J. P., & Jensen, K. F. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073718 · Cited by 359
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Self-citationHuebner, A., Bratton, D., Whyte, G., Yang, M., deMello, A. J., Abell, C., & Hollfelder, F. (2009) · Lab Chip · doi:10.1039/b813709a · Cited by 346
Miniaturising the laboratory in emulsion droplets
Griffiths, A. D., & Tawfik, D. S. (2006) · Trends in Biotechnology · doi:10.1016/j.tibtech.2006.06.009 · Cited by 346
“The aqueous microdroplets in microfluidics systems can be fused [48,49], subdivided [48,50], the contents of droplets mixed rapidly[48], incubated in delay lines[48], and sorted [49,51] (Figure 3). Enzymatic reactions can be performed in these systems, and the reaction kinetics can be determined by measuring fluoresce…”
BackgroundMoragues, T., Arguijo, D., Beneyton, T., Modavi, C., Simutis, K., Abate, A. R., Baret, J.-C., deMello, A. J., Densmore, D., & Griffiths, A. D. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00212-3 · Cited by 316
Preparation of highly monodisperse droplet in a T‐junction microfluidic device
Xu, J. H., Li, S. W., Tan, J., Wang, Y. J., & Luo, G. S. (2006) · AIChE Journal · doi:10.1002/aic.10924 · Cited by 335
Boedicker, J. Q., Vincent, M. E., & Ismagilov, R. F. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901550 · Cited by 327
Self-citationZheng, B., Tice, J. D., & Ismagilov, R. F. (2004) · Analytical Chemistry · doi:10.1021/ac0495743 · Cited by 321
Self-citation3D-printed microfluidic devices: fabrication, advantages and limitations—a mini review
Chen, C., Mehl, B. T., Munshi, A. S., Townsend, A. D., Spence, D. M., & Martin, R. S. (2016) · Analytical Methods · doi:10.1039/c6ay01671e · Cited by 303
Microfluidics-based systems biology
Breslauer, D. N., Lee, P. J., & Lee, L. P. (2006) · Molecular BioSystems · doi:10.1039/b515632g · Cited by 303
Controlled droplet microfluidic systems for multistep chemical and biological assays
Kaminski, T. S., & Garstecki, P. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00717h · Cited by 299
An acoustofluidic micromixer based on oscillating sidewall sharp-edges
Huang, P.-H., Xie, Y., Ahmed, D., Rufo, J., Nama, N., Chen, Y., Chan, C. Y., & Huang, T. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50568e · Cited by 288
High-resolution dose–response screening using droplet-based microfluidics
Miller, O. J., Harrak, A. E., Mangeat, T., Baret, J.-C., Frenz, L., Debs, B. E., Mayot, E., Samuels, M. L., Rooney, E. K., Dieu, P., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1113324109 · Cited by 286
“Several of these techniques generate droplets containing different concentrations of a compound by varying the relative flow rates of two or more aqueous streams (13, 18).”
BackgroundRoach, L. S., Song, H., & Ismagilov, R. F. (2005) · Analytical Chemistry · doi:10.1021/ac049061w · Cited by 277
Self-citationA fast microfluidic mixer based on acoustically driven sidewall-trapped microbubbles
Ahmed, D., Mao, X., Juluri, B. K., & Huang, T. J. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0444-3 · Cited by 272
“Despite their promise, the current acoustic-based mixing methods are limited by their slow mixing speed—it takes these methods a few seconds to tens of seconds to achieve homogenous mixing—and thus are not suitable for applications where fast mixing is needed, such as in enzymatic reactions (Song and Ismagilov 2003).”
BackgroundContinuous-Flow Polymerase Chain Reaction of Single-Copy DNA in Microfluidic Microdroplets
Schaerli, Y., Wootton, R. C., Robinson, T., Stein, V., Dunsby, C., Neil, M. A. A., French, P. M. W., deMello, A. J., Abell, C., & Hollfelder, F. (2009) · Analytical Chemistry · doi:10.1021/ac802038c · Cited by 263
Fallah-Araghi, A., Baret, J.-C., Ryckelynck, M., & Griffiths, A. D. (2012) · Lab on a Chip · doi:10.1039/c2lc21035e · Cited by 261
Microfluidics for Processing Surfaces and Miniaturizing Biological Assays
Delamarche, E., Juncker, D., & Schmid, H. (2005) · Advanced Materials · doi:10.1002/adma.200501129 · Cited by 251
Droplet breakup in microfluidic T-junctions at small capillary numbers
Jullien, M.-C., Tsang Mui Ching, M.-J., Cohen, C., Menetrier, L., & Tabeling, P. (2009) · Physics of Fluids · doi:10.1063/1.3170983 · Cited by 244
Li, L., Mustafi, D., Fu, Q., Tereshko, V., Chen, D. L., Tice, J. D., & Ismagilov, R. F. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607502103 · Cited by 246
Self-citationXu, J. H., Luo, G. S., Li, S. W., & Chen, G. G. (2006) · Lab Chip · doi:10.1039/b509939k · Cited by 235
Control and Measurement of the Phase Behavior of Aqueous Solutions Using Microfluidics
Shim, J.-U., Cristobal, G., Link, D. R., Thorsen, T., Jia, Y., Piattelli, K., & Fraden, S. (2007) · Journal of the American Chemical Society · doi:10.1021/ja071820f · Cited by 231
Microstructured Reactors for Multiphase Reactions: State of the Art
Kashid, M. N., & Kiwi-Minsker, L. (2009) · Industrial & Engineering Chemistry Research · doi:10.1021/ie8017912 · Cited by 226
Rapid screening of antibiotic toxicity in an automated microdroplet system
Churski, K., Kaminski, T. S., Jakiela, S., Kamysz, W., Baranska-Rybak, W., Weibel, D. B., & Garstecki, P. (2012) · Lab on a Chip · doi:10.1039/c2lc21284f · Cited by 228
Microfluidic Lab-on-a-Chip Platforms: Requirements, Characteristics and Applications
Mark, D., Haeberle, S., Roth, G., Von Stetten, F., & Zengerle, R. (2010) · NATO Science for Peace and Security Series A: Chemistry and Biology · doi:10.1007/978-90-481-9029-4_17 · Cited by 214
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Microvalve-actuated precise control of individual droplets in microfluidic devices
Zeng, S., Li, B., Su, X., Qin, J., & Lin, B. (2009) · Lab on a Chip · doi:10.1039/b821803j · Cited by 214
Miniaturized electrochemical sensors and their point-of-care applications
Zhang, W., Wang, R., Luo, F., Wang, P., & Lin, Z. (2020) · Chinese Chemical Letters · doi:10.1016/j.cclet.2019.09.022 · Cited by 212
Lagus, T. P., & Edd, J. F. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114005 · Cited by 213
“Serpentine channels have been employed to move samples across the field of view at discrete time intervals for fluorescent imaging, increasing total on-chip time for transient experiments [179].”
BackgroundControlling the Retention of Small Molecules in Emulsion Microdroplets for Use in Cell-Based Assays
Courtois, F., Olguin, L. F., Whyte, G., Theberge, A. B., Huck, W. T. S., Hollfelder, F., & Abell, C. (2009) · Analytical Chemistry · doi:10.1021/ac802658n · Cited by 212
Wang, G., Lim, C., Chen, L., Chon, H., Choo, J., Hong, J., & deMello, A. J. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2832-7 · Cited by 211
Protein Crystallization Using Microfluidic Technologies Based on Valves, Droplets, and SlipChip
Li, L., & Ismagilov, R. F. (2010) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.050708.133630 · Cited by 209
Self-citationMicrofluidic Synthesis of Polymer and Inorganic Particulate Materials
Park, J. I., Saffari, A., Kumar, S., Günther, A., & Kumacheva, E. (2010) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070909-104514 · Cited by 208
Droplet fusion by alternating current (AC) field electrocoalescence in microchannels
Chabert, M., Dorfman, K. D., & Viovy, J. (2005) · ELECTROPHORESIS · doi:10.1002/elps.200500109 · Cited by 210
Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme
Mazutis, L., Baret, J.-C., Treacy, P., Skhiri, Y., Araghi, A. F., Ryckelynck, M., Taly, V., & Griffiths, A. D. (2009) · Lab on a Chip · doi:10.1039/b907753g · Cited by 205
Controllable Preparation of Monodisperse O/W and W/O Emulsions in the Same Microfluidic Device
Xu, J. H., Li, S. W., Tan, J., Wang, Y. J., & Luo, G. S. (2006) · Langmuir · doi:10.1021/la0605743 · Cited by 196
A microdroplet dilutor for high-throughput screening
Niu, X., Gielen, F., Edel, J. B., & deMello, A. J. (2011) · Nature Chemistry · doi:10.1038/nchem.1046 · Cited by 199
“In the mass production of droplets using microfluidic T-junctions or flow-focusing geometries, the variation of volumetric flow-rate ratios (of the aqueous inputs) during the droplet-formation process provides a direct way of changing the relative concentration of encapsulated reagent”
Miniaturizing chemistry and biology in microdroplets
Kelly, B. T., Baret, J.-C., Taly, V., & Griffiths, A. D. (2007) · Chemical Communications · doi:10.1039/b616252e · Cited by 197
Development of Quantitative Cell-Based Enzyme Assays in Microdroplets
Huebner, A., Olguin, L. F., Bratton, D., Whyte, G., Huck, W. T. S., de Mello, A. J., Edel, J. B., Abell, C., & Hollfelder, F. (2008) · Analytical Chemistry · doi:10.1021/ac800338z · Cited by 193
Droplet breakup in microfluidic junctions of arbitrary angles
Ménétrier-Deremble, L., & Tabeling, P. (2006) · Physical Review E · doi:10.1103/physreve.74.035303 · Cited by 190
Fidalgo, L. M., Whyte, G., Ruotolo, B. T., Benesch, J. L. P., Stengel, F., Abell, C., Robinson, C. V., & Huck, W. T. S. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200806103 · Cited by 182
Single-molecule fluorescence detection in microfluidic channels—the Holy Grail in μTAS?
Dittrich, P. S., & Manz, A. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3335-9 · Cited by 182
Courtois, F., Olguin, L. F., Whyte, G., Bratton, D., Huck, W. T. S., Abell, C., & Hollfelder, F. (2008) · ChemBioChem · doi:10.1002/cbic.200700536 · Cited by 183
Microfluidic mixing through electrowetting-induced droplet oscillations
Mugele, F., Baret, J.-C., & Steinhauser, D. (2006) · Applied Physics Letters · doi:10.1063/1.2204831 · Cited by 176
Using nanoliter plugs in microfluidics to facilitate and understand protein crystallization
Zheng, B., Gerdts, C. J., & Ismagilov, R. F. (2005) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2005.08.009 · Cited by 173
“Formation of droplets in microchannels has been widely studied [30–32], and plugs have been used in emulsions [33,34], kinetic studies [35] and chemical synthesis [36,37].”
BackgroundSelf-citationReliable microfluidic on-chip incubation of droplets in delay-lines
Frenz, L., Blank, K., Brouzes, E., & Griffiths, A. D. (2009) · Lab Chip · doi:10.1039/b816049j · Cited by 170
Miniaturization and Parallelization of Biological and Chemical Assays in Microfluidic Devices
Vyawahare, S., Griffiths, A. D., & Merten, C. A. (2010) · Chemistry & Biology · doi:10.1016/j.chembiol.2010.09.007 · Cited by 167
Triboelectric wetting for continuous droplet transport
Xu, W., Jin, Y., Li, W., Song, Y., Gao, S., Zhang, B., Wang, L., Cui, M., Yan, X., & Wang, Z. (2022) · Science Advances · doi:10.1126/sciadv.ade2085 · Cited by 166
Flash chemistry using electrochemical method and microsystems
Yoshida, J.-I. (2005) · Chemical Communications · doi:10.1039/b508341a · Cited by 167
Zheng, B., Tice, J. D., & Ismagilov, R. F. (2004) · Advanced Materials · doi:10.1002/adma.200400590 · Cited by 163
Self-citationAn Acoustofluidic Micromixer via Bubble Inception and Cavitation from Microchannel Sidewalls
Ozcelik, A., Ahmed, D., Xie, Y., Nama, N., Qu, Z., Nawaz, A. A., & Huang, T. J. (2014) · Analytical Chemistry · doi:10.1021/ac5007798 · Cited by 162
Bogdan, A. R., & Sach, N. W. (2009) · Advanced Synthesis & Catalysis · doi:10.1002/adsc.200800758 · Cited by 159
Manipulation of droplets in microfluidic systems
Yang, C.-G., Xu, Z.-R., & Wang, J.-H. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.11.002 · Cited by 158
Micro-optics for microfluidic analytical applications
Yang, H., & Gijs, M. A. M. (2018) · Chemical Society Reviews · doi:10.1039/c5cs00649j · Cited by 161
Pro und kontra Strömungsreaktoren in der Synthese
Hartman, R. L., McMullen, J. P., & Jensen, K. F. (2011) · Angewandte Chemie · doi:10.1002/ange.201004637 · Cited by 155
Monitoring of Real-Time Streptavidin−Biotin Binding Kinetics Using Droplet Microfluidics
Srisa‐Art, M., Dyson, E. C., deMello, A. J., & Edel, J. B. (2008) · Analytical Chemistry · doi:10.1021/ac801199k · Cited by 155
Quantitative Online Detection of Low‐Concentrated Drugs via a SERS Microfluidic System
Ackermann, K., Henkel, T., & Popp, J. (2007) · ChemPhysChem · doi:10.1002/cphc.200700554 · Cited by 158
Advances in Optical Single‐Molecule Detection: En Route to Supersensitive Bioaffinity Assays
Farka, Z., Mickert, M. J., Pastucha, M., Mikušová, Z., Skládal, P., & Gorris, H. H. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201913924 · Cited by 160
SadAbadi, H., Bǎdilescu, S., Packirisamy, M., & Wüthrich, R. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.01.016 · Cited by 154
The potential of microfluidic water-in-oil droplets in experimental biology
Schaerli, Y., & Hollfelder, F. (2009) · Molecular BioSystems · doi:10.1039/b907578j · Cited by 150
Droplets as Microreactors for High‐Throughput Biology
Taly, V., Kelly, B. T., & Griffiths, A. D. (2007) · ChemBioChem · doi:10.1002/cbic.200600425 · Cited by 153
Song, H., Li, H., Munson, M. S., Ha, T. G. V., & Ismagilov, R. F. (2006) · Analytical Chemistry · doi:10.1021/ac0601718 · Cited by 144
Self-citationYue, J., Schouten, J. C., & Nijhuis, T. A. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie301258j · Cited by 131
Microfluidics Using Spatially Defined Arrays of Droplets in One, Two, and Three Dimensions
Pompano, R. R., Liu, W., Du, W., & Ismagilov, R. F. (2011) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.012809.102303 · Cited by 144
Self-citationMicrofluidics for Production of Particles: Mechanism, Methodology, and Applications
Liu, Z., Fontana, F., Python, A., Hirvonen, J. J., & Santos, H. A. (2019) · Small · doi:10.1002/smll.201904673 · Cited by 162
Controlled production of emulsions and particles by milli- and microfluidic techniques
Engl, W., Backov, R. V., & Panizza, P. (2007) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2007.09.003 · Cited by 137
Metadata
- Authors
- Song, H., & Ismagilov, R. F.
- Affiliations
- University of Chicago (US)
- ORCID
- Ismagilov, Rustem F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-29
- Volume
- 125
- Issue
- 47
- Pages
- 14613-14619
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- PMC
- PMC1769313
- OpenAlex
- W2028894110
- Cited by
- 693
- References
- 45
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 14 · 2023: 16 · 2022: 18 · 2021: 29 · 2020: 17 · 2019: 26 · 2018: 30 · 2017: 22 · 2016: 28 · 2015: 29 · 2014: 38 · 2013: 48 · 2012: 55
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institute of General Medical Sciences (GM08720, T32GM008720)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001903)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- droplet microfluidics, single-turnover kinetics, ribonuclease A, enzyme kinetics, chaotic advection, rapid mixing, PDMS microfluidic device, fluorescence imaging
- MeSH terms
- Biocompatible Materials, Kinetics, Microchemistry, Ribonuclease, Pancreatic, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.