The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Quantitative Real-Time Measurements of DNA Hybridization with Alkylated Nonoxidized Silicon Nanowires in Electrolyte Solution
Open accessAbstract
The quantitative, real-time detection of single-stranded oligonucleotides with silicon nanowires (SiNWs) in physiologically relevant electrolyte solution is demonstrated. Debye screening of the hybridization event is circumvented by utilizing electrostatically adsorbed primary DNA on an amine-terminated NW surface. Two surface functionalization chemistries are compared: an amine-terminated siloxane monolayer on the native SiO2 surface of the SiNW, and an amine-terminated alkyl monolayer grown directly on a hydrogen-terminated SiNW surface. The SiNWs without the native oxide exhibit improved solution-gated field-effect transistor characteristics and a significantly enhanced sensitivity to single-stranded DNA detection, with an accompanying 2 orders of magnitude improvement in the dynamic range of sensing. A model for the detection of analyte by SiNW sensors is developed and utilized to extract DNA-binding kinetic parameters. Those values are directly compared with values obtained by the standard method of surface plasmon resonance (SPR) and demonstrated to be similar. The nanowires, however, are characterized by higher detection sensitivity. The implication is that SiNWs can be utilized to quantitate the solution-phase concentration of biomolecules at low concentrations. This work also demonstrates the importance of surface chemistry for optimizing biomolecular sensing with silicon nanowires.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Elsevier eBooks · doi:10.1016/c2011-0-05119-0 · Cited by 8,968
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
A Laser Ablation Method for the Synthesis of Crystalline Semiconductor Nanowires
Morales, A. M., & Lieber, C. M. (1998) · Science · doi:10.1126/science.279.5348.208 · Cited by 4,383
Systems biology: a brief overview
Kitano, H. (2002) · Science · doi:10.1126/science.1069492 · Cited by 4,265
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Microscopic structure of theSiO2/Si interface
Himpsel, F. J., McFeely, F. R., Taleb-Ibrahimi, A., Yarmoff, J. A., & Hollinger, G. (1988) · Physical Review B · doi:10.1103/physrevb.38.6084 · Cited by 1,814
A genomic regulatory network for development
Davidson, E. H., Rast, J. P., Oliveri, P., Ransick, A., Calestani, C., Yuh, C.-H., Minokawa, T., Amore, G., Hinman, V., Arenas-Mena, C., et al. (2002) · Science · doi:10.1126/science.1069883 · Cited by 1,567
Cited by
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Highly ordered nanowire arrays on plastic substrates for ultrasensitive flexible chemical sensors
McAlpine, M. C., Ahmad, H., Wang, D., & Heath, J. R. (2007) · Nature Materials · doi:10.1038/nmat1891 · Cited by 959
Self-citationImportance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Supramolecular self-assemblies as functional nanomaterials
Busseron, E., Ruff, Y., Moulin, E., & Giuseppone, N. (2013) · Nanoscale · doi:10.1039/c3nr02176a · Cited by 701
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Zhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Label-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Synthesis and applications of one-dimensional semiconductors
Barth, S., Hernandez-Ramirez, F., Holmes, J. D., & Romano-Rodriguez, A. (2010) · Progress in Materials Science · doi:10.1016/j.pmatsci.2010.02.001 · Cited by 496
An Optofluidic Nanoplasmonic Biosensor for Direct Detection of Live Viruses from Biological Media
Yanik, A. A., Huang, M., Kamohara, O., Artar, A., Geisbert, T. W., Connor, J. H., & Altug, H. (2010) · Nano Letters · doi:10.1021/nl103025u · Cited by 454
Xu, S., Zhan, J., Man, B., Jiang, S., Yue, W., Gao, S., Guo, C., Liu, H., Li, Z., Wang, J., et al. (2017) · Nature Communications · doi:10.1038/ncomms14902 · Cited by 437
Knopfmacher, O., Hammock, M. L., Appleton, A. L., Schwartz, G., Mei, J., Lei, T., Pei, J., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms3954 · Cited by 415
Kelley, S. O., Mirkin, C. A., Walt, D. R., Ismagilov, R. F., Toner, M., & Sargent, E. H. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.261 · Cited by 398
Polymer-Functionalized Nanodiamond Platforms as Vehicles for Gene Delivery
Zhang, X.-Q., Chen, M., Lam, R., Xu, X., Osawa, E., & Ho, D. (2009) · ACS Nano · doi:10.1021/nn900865g · Cited by 395
Ramgir, N. S., Yang, Y., & Zacharias, M. (2010) · Small · doi:10.1002/smll.201000972 · Cited by 383
Duan, X., Li, Y., Rajan, N. K., Routenberg, D. A., Modis, Y., & Reed, M. A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.82 · Cited by 366
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Heath, J. R., & Davis, M. E. (2008) · Annual Review of Medicine · doi:10.1146/annurev.med.59.061506.185523 · Cited by 354
Self-citationHeath, J. R. (2009) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-082908-145401 · Cited by 318
Self-citationDesign Considerations of Silicon Nanowire Biosensors
Nair, P. R., & Alam, M. A. (2007) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2007.909059 · Cited by 316
Microfluidic sample preparation: cell lysis and nucleic acid purification
Kim, J., Johnson, M., Hill, P., & Gale, B. K. (2009) · Integrative Biology · doi:10.1039/b905844c · Cited by 282
DNA Sensing by Silicon Nanowire: Charge Layer Distance Dependence
Zhang, G.-J., Zhang, G., Chua, J. H., Chee, R.-E., Wong, E. H., Agarwal, A., Buddharaju, K. D., Singh, N., Gao, Z., & Balasubramanian, N. (2008) · Nano Letters · doi:10.1021/nl072991l · Cited by 278
Nanowire Chemical/Biological Sensors: Status and a Roadmap for the Future
Fennell, J. F., Liu, S. F., Azzarelli, J. M., Weis, J. G., Rochat, S., Mirica, K. A., Ravnsbæk, J. B., & Swager, T. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201505308 · Cited by 274
Bailey, R. C., Kwong, G. A., Radu, C. G., Witte, O. N., & Heath, J. R. (2007) · Journal of the American Chemical Society · doi:10.1021/ja065930i · Cited by 272
Self-citationSilicon nanowire biosensor and its applications in disease diagnostics: A review
Zhang, G.-J., & Ning, Y. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.08.035 · Cited by 268
Chua, J. H., Chee, R.-E., Agarwal, A., Wong, S. M., & Zhang, G.-J. (2009) · Analytical Chemistry · doi:10.1021/ac901157x · Cited by 266
Label-free direct detection of MiRNAs with silicon nanowire biosensors
Zhang, G.-J., Chua, J. H., Chee, R.-E., Agarwal, A., & Wong, S. M. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.12.035 · Cited by 265
Silicon nanowire biosensor for highly sensitive and rapid detection of Dengue virus
Zhang, G.-J., Zhang, L., Huang, M. J., Luo, Z. H. H., Tay, G. K. I., Lim, E.-J. A., Kang, T. G., & Chen, Y. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.02.021 · Cited by 258
Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity
Li, J., Zhang, Y., To, S., You, L., & Sun, Y. (2011) · ACS Nano · doi:10.1021/nn202182p · Cited by 138
Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering
Shoorideh, K., & Chui, C. O. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2214221 · Cited by 65
Metadata
- Authors
- Bunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-12-01
- Volume
- 128
- Issue
- 50
- Pages
- 16323-16331
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2018553797
- Cited by
- 480
- References
- 47
- FWCI
- 22.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.