The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Conjugated Polymer Dots for Multiphoton Fluorescence Imaging
Open accessAbstract
We report on the two-photon excited fluorescence of conjugated polymer dots (CPdots). As a new class of two-photon fluorescent probes, CPdots exhibit two-photon action cross sections as high as 2.0 × 10 5 GM, to our knowledge, the largest reported thus far for a nanoparticle. The cross section values are 3−4 orders of magnitude higher than those of conventional fluorescent dyes and an order of magnitude higher than those of inorganic quantum dots. Single particle fluorescence imaging was achieved using relatively low laser power.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Electroluminescence in conjugated polymers
Friend, R. H., Gymer, R. W., Holmes, A. B., Burroughes, J. H., Marks, R. N., Taliani, C., Bradley, D. D. C., Santos, D. A. D., Brédas, J. L., Lögdlund, M., et al. (1999) · Nature · doi:10.1038/16393 · Cited by 5,977
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Water-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
Design of Organic Molecules with Large Two-Photon Absorption Cross Sections
Albota, M., Beljonne, D., Brédas, J.-L., Ehrlich, J. E., Fu, J.-Y., Heikal, A. A., Hess, S. E., Kogej, T., Levin, M. D., Marder, S. R., et al. (1998) · Science · doi:10.1126/science.281.5383.1653 · Cited by 2,245
Xu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198
Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165
Two-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
In vitro and in vivo two-photon luminescence imaging of single gold nanorods
Wang, H., Huff, T. B., Zweifel, D. A., He, W., Low, P. S., Wei, A., & Cheng, J.-X. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504892102 · Cited by 950
Rumi, M., Ehrlich, J. E., Heikal, A. A., Perry, J. W., Barlow, S., Hu, Z., McCord-Maughon, D., Parker, T. C., Röckel, H., Thayumanavan, S., et al. (2000) · Journal of the American Chemical Society · doi:10.1021/ja994497s · Cited by 858
Cited by
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
Polymer-encapsulated organic nanoparticles for fluorescence and photoacoustic imaging
Li, K., & Liu, B. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00014e · Cited by 987
Conjugated polymer nanoparticles
Tuncel, D., & Demir, H. V. (2010) · Nanoscale · doi:10.1039/b9nr00374f · Cited by 428
Constitutional Isomerization Enables Bright NIR‐II AIEgen for Brain‐Inflammation Imaging
Liu, S., Chen, C., Li, Y., Zhang, H., Liu, J., Wang, R., Wong, S. T. H., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908125 · Cited by 267
Two‐Photon Fluorescent Probes for Bioimaging
Yao, S., & Belfield, K. D. (2012) · European Journal of Organic Chemistry · doi:10.1002/ejoc.201200281 · Cited by 261
Zhang, Z., Fang, X., Liu, Z., Liu, H., Chen, D., He, S., Zheng, J., Yang, B., Qin, W., Zhang, X., et al. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201914397 · Cited by 242
Self-citationNear-Infrared Fluorescent Dye-Doped Semiconducting Polymer Dots
Jin, Y., Ye, F., Zeigler, M., Wu, C., & Chiu, D. T. (2011) · ACS Nano · doi:10.1021/nn103304m · Cited by 211
Self-citationLi, T., Yang, D., Zhai, L., Wang, S., Zhao, B., Fu, N., Wang, L., Tao, Y., & Huang, W. (2017) · Advanced Science · doi:10.1002/advs.201600166 · Cited by 138
Wang, S., Liu, J., Feng, G., Ng, L. G., & Liu, B. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808365 · Cited by 110
Semiconducting polymer dots with bright narrow-band emission at 800 nm for biological applications
Chen, D., Wu, I.-C., Liu, Z., Tang, Y., Chen, H., Yu, J., Wu, C., & Chiu, D. T. (2017) · Chemical Science · doi:10.1039/c7sc00441a · Cited by 78
Self-citationLv, Y., Liu, P., Ding, H., Wu, Y., Yan, Y., Liu, H., Wang, X., Huang, F., Zhao, Y., & Tian, Z. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b05150 · Cited by 56
Metadata
- Authors
- Wu, C., Szymanski, C., Cain, Z., & McNeill, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-01
- Volume
- 129
- Issue
- 43
- Pages
- 12904-12905
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2102719766
- Cited by
- 323
- References
- 19
- FWCI
- 11.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.